1.Investigation and health risk assessment of microbial contamination of indoor air in public places in Xi'an City
Dong LIU ; Fan GAO ; Feng ZHANG ; Ping LIU ; Ling CHANG
Journal of Public Health and Preventive Medicine 2026;37(1):78-82
Objective To investigate the microbial contamination and its influencing factors of indoor air in public places in Xi'an City, to assess the health risk of employees, and to provide a scientific basis for improving the indoor environment of public places. Methods Total bacterial count and total fungal count in indoor air were monitored in hotels/inns, shopping malls/supermarkets, gyms, and waiting rooms in Xi'an from 2023 to 2024. The health risk assessment of employees was evaluated according to the Chinese Population Exposure Parameters Manual (Adult Volume). Results Overall, the standard-exceeding rate of total bacterial count in Xi'an was 3.85%, and the median values of total bacterial count and total fungal count were 350 CFU/m3 and 300 CFU/m3, respectively. The results of the generalized linear model showed that high indoor temperature and PM10 levels were associated with increased indoor bacterial concentrations (β>0, P<0.05), while high daily passenger flow, and high indoor relative humidity and PM10 levels were associated with increased indoor fungal concentrations (β>0, P<0.05). The multivariate logistic regression showed that high levels of indoor bacterial and fungal concentrations were risk factors for respiratory discomfort among employees. The hazard quotient (HQ) values for all types of public places were less than 1, indicating that the health risk of microbial aerosol exposures for employees was relatively low. Conclusion The indoor microbial pollution in public places in Xi'an is relatively mild, but countermeasures still need to be taken to reduce indoor air microbial contamination.
2.Connection quality and influencing factors of Shaanxi psychological assistance hotline operators based on conversations involving suicide intentions
Huadong JIANG ; Zhen FAN ; Yatong NING ; Jingxuan WU ; Lei ZHANG ; Pin ZHANG ; Yanli SU
Journal of Public Health and Preventive Medicine 2026;37(2):180-184
Objective To explore the factors affecting the quality of psychological assistance hotline connections in Shaanxi Province, and to provide a basis for optimizing services. Methods A total of 149 calls with suicidal tendencies were included from January to March 2022, and data were collected by 31 trained assessors through standardized questionnaires (general information, suicide risk, emotional intensity, and wiring characteristics). Results The results showed that 56.38% of the callers were female, with age groups concentrated between ≤ 18 years old (29.53%) and 19-34 years old (43.62%). The call duration was mainly between 31 and 45 minutes (50.34%). Operators conducted a suicide risk assessment on the callers, with 38.9% having a comprehensive assessment, 38.9% having an incomplete assessment, and 22.1% having no assessment. The main mental disorders of the callers were depression (48.32%), anxiety (15.44%), and bipolar disorder (14.77%), with 25.50% having comorbidities of ≥ 2 disorders. Emotional scores were as follows: depression (4.11 ± 0.76), sadness (3.97 ± 1.03), and despair (3.78 ± 1.05). There were significant differences in depression, anger, despair, and sadness among the callers with different levels of danger (t=4.79, 3.35, 15.79, 4.24, all P<0.05). Women had higher levels of fear than men (t=3.10, P<0.01). The longer the call duration, the higher the level of despair (t=5.66, P<0.01). Multiple regression analysis showed that incomplete suicide risk assessment by operators (B=-2.36), general procedures for operators' connections (B=5.44), and technical factors (B=2.01) significantly affected the quality of psychological assistance hotlines (all P<0.05). Conclusion Callers with suicidal tendencies generally have serious mental and psychological problems and prominent negative emotions. Strengthening the suicide risk assessment ability of operators and standardizing processes and service attitudes are key to improving the quality of psychological assistance hotlines.
3.Expert consensus on the application of artificial intelligence in lung cancer screening, diagnosis, and treatment (2026 edition)
Wenzhao ZHONG ; Haibo WANG ; Yi HU ; Hao ZHANG ; Jigang DAI ; Junqiang FAN ; Guibin QIAO ; Fan YANG ; Jian HU ; Fengwei TAN ; Xuening YANG ; Qiang PU ; Zihao CHEN ; Hongxia TIAN ; Lunxu LIU ; Hecheng LI ; Xiaolong YAN ; Zongyang YU ; Zhenbin QIU ; Yihua SUN ; Jing HU ; Yuhang SHI ; Zhifei GUO ; Peng ZHANG ; Kezhong CHEN ; Shugeng GAO ; Yilong WU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(06):848-856
With the continuous deepening of the concept of precision diagnosis and treatment for lung cancer, how to achieve higher efficiency and accuracy in the screening, diagnosis, and treatment pathways in clinical practice has become an important issue that urgently needs to be overcome. The current clinical difficulty lies in the fact that despite continuous advancements in imaging and molecular diagnostic technologies, there are still limitations in manual efficiency and subjective experience when it comes to massive data analysis and multi-scale feature extraction. Artificial intelligence (AI), especially algorithm systems based on deep learning, is an innovative technology capable of deeply empowering medical big data. This method utilizes algorithms such as convolutional neural networks, combined with radiomics, pathomics, and multi-modal data fusion analysis, demonstrating immense potential in early precise detection and benign-malignant differentiation of pulmonary nodules, digital pathological subtype recognition and non-invasive prediction of driver genes, precise 3D surgical planning and automatic delineation of radiotherapy target volumes, as well as dynamic risk warning during follow-up. This innovative technology provides a brand-new solution for realizing intelligent and individualized lung cancer diagnosis and treatment models. This consensus, based on the latest evidence from evidence-based medicine and combined with the development trends in the AI field and real-world clinical needs, was ultimately formed by gathering the consensus opinions of multidisciplinary experts in radiology, pathology, thoracic surgery, and other fields. The main content covers the application specifications of AI in the three core scenarios of lung cancer screening, diagnosis, and treatment, the technical standards for data collection and algorithm validation, as well as the ethical and regulatory challenges faced at the current stage. It aims to clarify the applicable boundaries of AI as a clinical auxiliary decision support tool, providing scientific guidance and standardized exploration directions for peers currently engaged in or planning to carry out AI-assisted clinical diagnosis, treatment, and translation of lung cancer.
4.Study on the consistency and diagnostic efficacy of kidney clear cell likelihood score v2.0 using high and low field intensity MRI
Xi LONG ; Xiumei DU ; Yingsi YANG ; Weixiong FAN ; Tianhui ZHANG
Journal of Practical Radiology 2025;41(9):1512-1516
Objective To investigate the consistency and diagnostic efficacy of 1.5T and 3.0T MRI in the kidney clear cell likeli-hood score(ccLS)v2.0.Methods A retrospective collection was conducted on the data of 176 pathologically confirmed small renal mass(SRM).Two radiologists independently scored the MRI images using the ccLS v2.0.The Kappa test was used to assess inter-observer consistency,and receiver operating characteristic(ROC)curves were plotted to analyze the diagnostic efficacy.The area under the curve(AUC),sensitivity,specificity,positive predictive value(PPV),and negative predictive value(NP V)were calculated.Results The inter-observer consistency for ccLS v2.0 score was good for 1.5T MRI and excellent for 3.0T MRI(Kappa values were 0.754 and 0.836,respectively).On 1.5T MRI examination,a ccLS≥4 points was identified as the optimal threshold,with AUC of 0.935 and 0.923 for the two radiologists,sensitivities of 92.45%and 88.68%,and specificities of 88.00%and 92.00%,respec-tively.For 3.0T MRI examination,using the same threshold,the AUC were 0.933 and 0.901,with sensitivities of 91.43%and 90.00%,and specificities of 78.57%and 78.57%for both radiologists.Conclusion The ccLS v2.0 demonstrates good consistency across high and low field intensity MRI,and a threshold of ccLS≥4 pionts provides high diagnostic efficacy for clear cell renal cell carcinoma(ccRCC).
5.Effects of Congrong San on neuronal apoptosis and Bax/Bcl-2/Caspase3 signaling pathway in a rat model of Alzheimer's disease
Yuan-qin CAI ; Yang XIANG ; Qing-hua LONG ; Xi WANG ; Jing-fan ZHANG ; Chu-hua ZENG
Chinese Traditional Patent Medicine 2025;47(4):1122-1128
AIM To investigate the effects of Congrong San on neuronal apoptosis and the Bax/Bcl-2/Caspase3 signaling pathway in a rat model of Alzheimer's disease(AD).METHODS A total of 60 2-month-old SD male rats were randomly divided into the blank group,the model group,the memantine hydrochloride group(0.025 g/kg)and low-dose,medium-dose and high-dose Congrong San groups(4.62,9.24,18.48 g/kg).All groups except the control group received stereotactic intracerebral injection of Aβ1-42 to establish AD models.Following the successful modeling,each group received its corresponding intragastric administration once daily for 28 consecutive days.After the administration,the rats had their learning and memory ability detected by the morris water maze test;their hippocampal neuronal morphology observed with HE and Nissl staining;their hippocampal neuronal apoptosis observed with TUNEL staining;and their hippocampal expressions of amyloid precursor protein(APP),β-site APP-cleaving enzyme 1(BACE1),and apoptosis-related proteins Bax,Bcl-2 and Caspase3 detected with Western blot assay.RESULTS Compared with the model group,the groups intervened with medium-dose and high-dose Congrong San exhibited improved learning and memory performance,alleviated hippocampal neuronal damage,increased Nissl body count(P<0.01),reduced hippocampal apoptosis rate(P<0.05,P<0.01),decreased protein expressions of APP,BACE1,Bax and cleaved-Caspase3/Caspase3 ratio(P<0.05,P<0.01),and elevated Bcl-2 expression(P<0.01).CONCLUSION Congrong San mitigates cognitive impairment,hippocampal neuronal damage,and apoptosis in AD rats,probably through inhibition of the Bax/Bcl-2/Caspase3 signaling pathway activation.
6.Research on coagulation effect of cold atmospheric plasma jet device and its mechanism of action
Yan LI ; Hong-ye ZHENG ; Ao-xi XU ; Ya-jun ZHAO ; Shan-shan JIN ; Xu ZHANG ; Yu-fan WEI ; Yi-heng ZHANG ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(6):20-27
Objective To investigate the coagulation effect of a cold atmospheric plasma(CAP)jet device with helium as the working gas and to study its coagulation mechanism preliminarily.Methods A CAP jet device treatment group,a helium airflow treatment group,a hot air treatment group(60℃)and a natural coagulation group were formed according to the treatment modes of the blood samples,with 10 μL of blood samples involved in each group,in order to validate the coagulation effect of the CAP jet device in vitro;the coagulation mechanism of the CAP jet device was explored by its application to the treatment of anticoagulated whole blood,platelet-rich plasma and platelet-depleted plasma;the coagulation effect of the CAP jet device in vivo was verified with a mouse liver punctate hemorrhage model and a rabbit mesenteric hemorrhage model.Results The CAP jet device can significantly accelerate the coagulation of anticoagulated blood droplets,and the coagulation time of anticoagulated blood droplets in the CAP jet device-treated group was shortened from 28 min in the natural coagulation group to(23±1.56)s,with the difference statistically significant(P<0.05),and the CAP jet device treatment group gained advantages significantly over the helium airflow treatment group(P<0.05)and the hot air(60℃)treatment group(P<0.05)in coagulation-promoting effect;the procoagulant effect of the CAP jet device rose with the increase of platelet content in blood droplets,and the coagulation effect of platelet-rich blood droplets was significantly better than that of whole blood(P<0.05),while no coagulation was observed in platelet-poor droplets.The CAP jet device could rapidly stop hemostasis of punctate hemorrhage in mouse liver and mesenteric hemorrhage in rabbits without delayed hemorrhage occurring within 10 min,and no obvious structural abnormality of the liver and thermal damage of the tissue were found microscopically.Conclusion The CAP jet device plays procoagulant and hemostatic effects in vivo and in vitro,and its effect is not dependent on temperature and airflow evaporation effects and is considered to be related to platelet activation,with low thermal damage to living tissue.[Chinese Medical Equipment Journal,2025,46(6):20-27]
7.Research on coagulation effect of cold atmospheric plasma jet device and its mechanism of action
Yan LI ; Hong-ye ZHENG ; Ao-xi XU ; Ya-jun ZHAO ; Shan-shan JIN ; Xu ZHANG ; Yu-fan WEI ; Yi-heng ZHANG ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(6):20-27
Objective To investigate the coagulation effect of a cold atmospheric plasma(CAP)jet device with helium as the working gas and to study its coagulation mechanism preliminarily.Methods A CAP jet device treatment group,a helium airflow treatment group,a hot air treatment group(60℃)and a natural coagulation group were formed according to the treatment modes of the blood samples,with 10 μL of blood samples involved in each group,in order to validate the coagulation effect of the CAP jet device in vitro;the coagulation mechanism of the CAP jet device was explored by its application to the treatment of anticoagulated whole blood,platelet-rich plasma and platelet-depleted plasma;the coagulation effect of the CAP jet device in vivo was verified with a mouse liver punctate hemorrhage model and a rabbit mesenteric hemorrhage model.Results The CAP jet device can significantly accelerate the coagulation of anticoagulated blood droplets,and the coagulation time of anticoagulated blood droplets in the CAP jet device-treated group was shortened from 28 min in the natural coagulation group to(23±1.56)s,with the difference statistically significant(P<0.05),and the CAP jet device treatment group gained advantages significantly over the helium airflow treatment group(P<0.05)and the hot air(60℃)treatment group(P<0.05)in coagulation-promoting effect;the procoagulant effect of the CAP jet device rose with the increase of platelet content in blood droplets,and the coagulation effect of platelet-rich blood droplets was significantly better than that of whole blood(P<0.05),while no coagulation was observed in platelet-poor droplets.The CAP jet device could rapidly stop hemostasis of punctate hemorrhage in mouse liver and mesenteric hemorrhage in rabbits without delayed hemorrhage occurring within 10 min,and no obvious structural abnormality of the liver and thermal damage of the tissue were found microscopically.Conclusion The CAP jet device plays procoagulant and hemostatic effects in vivo and in vitro,and its effect is not dependent on temperature and airflow evaporation effects and is considered to be related to platelet activation,with low thermal damage to living tissue.[Chinese Medical Equipment Journal,2025,46(6):20-27]
8.Study of debridement effects of multi shapes of plasma scalpels in explosion injury model
Hong-ye ZHENG ; Yu LI ; Zi-heng XU ; Yu-fan WEI ; Bo-ya ZHANG ; Yan LI ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(2):31-38
Objective To explore the debridement effects of 3 types of plasma scalpels for the animal model of explosion injury,and to compare them with the steel scalpel and high-frequency electrosurgical scalpel.Methods Firstly,blast wounds were constructed in the right inguinal regions of 9 Landrace pigs by high-pressure gas impact combined with preset metal shrapnel.Secondly,debridement was carried out in experimental groups with wide-,arrow-or needle-type plasma scalpel and in control groups with steel and high-frequency electrisurgical scalpel,with the operating temperature and debridement time recorded during the procedure and trauma specimens analyzed pathologically after the debridement;comparisons were performed among the five types of scalpels in terms of debridement effect,and among the four ones in terms of maximum operating temperature and depth of tissue thermal damage under electrocutaneous cutting and electrocoagulation modes with the steel scalpel excluded because it did not generate any heat.GraphPad Prism 9.5.1 software was used for statistical analysis.Results There were no significant differences in debridement effect found between the three plasma scalpels and the steel and high-frequency electrosurgical scalpels(P>0.05).The three types of plasma scalpels had the maximum operating temperature lower significantly than that of the high-frequency electrosurgical scalpel during debridement(P<0.05).Under electrosection and electrocoagulation modes the three plasma scalpels had the depths of tissue thermal damage statistically less than that by the high-frequency electrosurgical scalpel under electrosection and electrocoagulation modes(P<0.05).The depths of tissue thermal damage by the four scalpels under electrocoagulation mode were obviously greater than those under electrosection mode(P<0.05).Conclusion Multi shapes of plasma scalpels behave well in debridement with low operating temperature,little tissue thermal damage and high efficiency for wound protection and the same efficacy with the steel scalpel and high-frequency electrosur-gical scalpel.[Chinese Medical Equipment Journal,2025,46(2):31-38]
9.Study on the consistency and diagnostic efficacy of kidney clear cell likelihood score v2.0 using high and low field intensity MRI
Xi LONG ; Xiumei DU ; Yingsi YANG ; Weixiong FAN ; Tianhui ZHANG
Journal of Practical Radiology 2025;41(9):1512-1516
Objective To investigate the consistency and diagnostic efficacy of 1.5T and 3.0T MRI in the kidney clear cell likeli-hood score(ccLS)v2.0.Methods A retrospective collection was conducted on the data of 176 pathologically confirmed small renal mass(SRM).Two radiologists independently scored the MRI images using the ccLS v2.0.The Kappa test was used to assess inter-observer consistency,and receiver operating characteristic(ROC)curves were plotted to analyze the diagnostic efficacy.The area under the curve(AUC),sensitivity,specificity,positive predictive value(PPV),and negative predictive value(NP V)were calculated.Results The inter-observer consistency for ccLS v2.0 score was good for 1.5T MRI and excellent for 3.0T MRI(Kappa values were 0.754 and 0.836,respectively).On 1.5T MRI examination,a ccLS≥4 points was identified as the optimal threshold,with AUC of 0.935 and 0.923 for the two radiologists,sensitivities of 92.45%and 88.68%,and specificities of 88.00%and 92.00%,respec-tively.For 3.0T MRI examination,using the same threshold,the AUC were 0.933 and 0.901,with sensitivities of 91.43%and 90.00%,and specificities of 78.57%and 78.57%for both radiologists.Conclusion The ccLS v2.0 demonstrates good consistency across high and low field intensity MRI,and a threshold of ccLS≥4 pionts provides high diagnostic efficacy for clear cell renal cell carcinoma(ccRCC).
10.Predicting microsatellite instability status in endometrial cancer based on whole-tumor apparent diffusion coefficient histogram
Tianhui ZHANG ; Xiumei DU ; Qiuming WANG ; Yuhui ZHANG ; Xi LONG ; Yingsi YANG ; Weixiong FAN
Journal of Practical Radiology 2025;41(10):1694-1698
Objective To investigate the value of predicting microsatellite instability(MSI)status in endometrial cancer based on whole-tumor apparent diffusion coefficient(ADC)histogram.Methods The data of 131 endometrial cancer patients who underwent preoperative MRI examination and were confirmed by pathology were retrospectively analyzed.According to the pathological immu-nohistochemical results,they were divided into microsatellite stability(MSS)group(103 cases)and MSI group(28 cases).The whole-tumor volume of interest(VOI)was outlined using ITK-SNAP software,and ADC histogram analysis was performed using uAI Research Portal software.The t-test or Mann-Whitney U-test were used to compare the differences between the two groups,and multifactorial logistic regression analysis was used to screen independent predictors for the above parameters with differences.The area under the curve(AUC),sensitivity and specificity were calculated using the receiver operating characteristic(ROC)curve.Results The ADC histogram parameters that were statistically significant between groups were ADC10th,ADC90th,ADCmaximum,ADCmedian,ADCmean,ADCrange,ADCinterquartile range,ADCuniformity,ADCvariance,ADCenergy,ADCentropy,ADCtotal energy,ADCroot mean square,ADCmean absolute deviation,ADCrobust mean absolute deviation,all the above parameters were significantly smaller in the MSI group than in the MSS group.Further multifactorial logistic regression analysis results showed that ADCmedian[odds ratio(OR)=1.019,P=0.020]and ADCroot mean square(OR=0.977,P=0.005)were independent predictors of the MSI status in endometrial cancer.The results of ROC curve showed that the AUC of ADCmedian and ADCroot mean square for predicting MSI status were 0.699 and 0.731,respectively,and the AUC of combining the two parameters to predict MSI status was 0.760,with a sensitivity of 57.14%and a specificity of 86.41%.Conclusion The parameters of ADCmedian and ADCroot mean square based on whole-tumor ADC histogram can be used to predict the MSI status of endometrial cancer,and the combined use of these two parameters helps to improve the efficacy of predicting MSI.


Result Analysis
Print
Save
E-mail