1.Association of the joint effect of body fat levels and dyslipidemia with cardiovascular structural changes among children
ZHANG Qiyue, ZHAO Min, WANG Mingming, XI Bo
Chinese Journal of School Health 2026;47(4):480-485
Objective:
To investigate the association of the joint effect of body fat levels and dyslipidemia with cardiovascular structural abnormalities in children, so as to provide a scientific reference for the early prevention of cardiovascular damage.
Methods:
Based on the data from the second follow up (October 2021 to January 2022) of the Huantai Children Cardiovascular Health Follow up Cohort, 1 308 children with complete data were included. The fat mass percentage (FMP), fat mass index (FMI), subcutaneous fat mass (SFM) and visceral fat mass (VFM), left ventricular mass index (LVMI), relative wall thickness (RWT), thickening of carotid intima-media thickening (cIMT) , left ventricular hypertrophy (LVH) and left ventricular geometric remodeling (LVG), triglyceride (TG), total cholesterol (TC) ,high density lipoprotein cholesterol (HDL-C) and low density lipoprotein cholesterol (LDL-C) were obtained. Multivariable Logistic regression model was used to analyze the associations of FMP, FMI, SFM and VFM with thickening of cIMT, LVH and LVG. The joint effects of these body fat indicators and dyslipidemia on the aforementioned cardiovascular outcomes were further explored. Restricted cubic spline model was used to examine the dose response relationships between body fat levels and cardiovascular structural abnormalities.
Results:
Elevated body fat levels were significantly associated with an increased risk of cardiovascular structural abnormalities, exhibiting J shaped dose response relationships (all P <0.05). Compared with the group with normal body fat and normolipidemia, the risks of thickening of cIMT, LVH, and LVG in the group with elevated FMP combined with dyslipidemia were higher[ OR (95% CI )=11.70 (6.49-21.27), 5.53 (2.97-10.17), 2.33 (1.30-4.05)]; in the group with elevated FMI combined with dyslipidemia, the corresponding risks were higher[ OR (95% CI )= 11.68 (6.43-21.38), 6.98 (3.73-12.92), 2.65 (1.50-4.61)]; in the group with elevated SFM combined with dyslipidemia, the corresponding risks were higher[ OR (95% CI )=10.55 (5.83-19.24), 5.11 (2.71-9.45), 1.99 (1.11- 3.46 )]; and in the group with elevated VFM combined with dyslipidemia, the corresponding risks were higher[ OR (95% CI )=12.44 (6.76-23.14), 6.17 ( 3.31 -11.38), 2.30 (1.30-3.99)] (all P <0.05). Sex stratified analyses showed that the risk of thickening of cIMT in the combined exposure group of all four body fat indicators and dyslipidemia was significantly higher in girls than in boys (all P <0.01).
Conclusions
Elevated body fat levels and dyslipidemia have a combined effect in children, collectively increasing the risk of cardiovascular structural abnormalities. Prevention of cardiovascular damage in children should focus on both adiposity management and blood lipid regulation.
2.Dose response relationship between sleep duration and depressive symptoms risk in children and adolescents
DAI Chaolan, ZHAO Min, WANG Mingming, XI Bo
Chinese Journal of School Health 2026;47(1):80-84
Objective:
To investigate the association between sleep duration and depressive symptoms in children and adolescents, so as to provide scientific evidence for promoting mental health and preventing depression among relevant populations.
Methods:
A total of 2 192 children and adolescents aged 10-17 years with complete data from the 2018 China Family Panel Studies Database were included. Eight item Center for Epidemiologic Studies Depressive Scale(CES-D8) was used to assess participants depressive levels, and sleep duration was assessed via questionnaire. Multivariate Logistic regression model was used to analyze the association between different sleep duration categories and depressive symptom occurrence among children and adolescents. A restricted cubic spline(RCS) model analyzed the dose response relationship between sleep duration and the risk of depressive symptoms occurrence and segmented Logistic regression models to identify dose response effects.
Results:
Among the surveyed children and adolescents, 524(23.91%) exhibited depressive symptoms. Compared to those with sufficient sleep, children aged 10-12 years had a higher risk of depressive symptoms on average per day( OR =1.66, 95% CI =1.19-2.33) and during weekdays( OR =1.76, 95% CI =1.26-2.46), as well as in adolescents aged 13-17 years on a daily basis( OR =1.40,95% CI =1.06-1.85) and during weekdays( OR = 1.48,95% CI =1.12-1.95), and excessive sleep in adolescents on rest days was also significantly associated with higher risk of depressive symptoms( OR =1.65,95% CI =1.11-2.43)(all P <0.05). RCS analysis results indicate that children s sleep duration exhibits a linear negative correlation with the risk of depressive symptoms(all P nonlinear >0.05), while adolescents sleep duration showed a U shaped association with depressive symptoms(all P nonlinear <0.05) on a daily basis, during weekdays and weekends, with potential threshold effects at 10.00, 9.88, and 9.60 hours, respectively.
Conclusions
Sleep duration among children and adolescents is associated with depressive symptoms, with notable age related differeneces. It is recommended to develop targeted age specific interventions to reduce the risk of depressive symptoms in children and adolescents.
3.Transcranial Focused Ultrasound Stimulation of the Primary Somatosensory Cortex Evokes Hand Tactile Perception: The Effect of Sonication Duration
Xu-Xu CHEN ; Huan-Jun XI ; Zhen LIANG ; Bo WANG ; Xu-Dong ZHAO
Progress in Biochemistry and Biophysics 2026;53(7):1942-1952
ObjectiveTranscranial focused ultrasound (tFUS) has emerged as a promising noninvasive neuromodulation technique capable of modulating neural activity with high spatial specificity. However, whether tFUS stimulation of the primary somatosensory cortex (S1) can reliably evoke conscious tactile perception without external peripheral sensory input remains unclear. Therefore, this study examined the feasibility of inducing hand-related tactile perception through targeted S1 stimulation and further investigated how sonication duration (SD), a key temporal parameter, influences the consistency of this perceptual response. The findings may provide empirical evidence for optimizing tFUS parameters in human somatosensory modulation. MethodsForty-eight healthy adults participated in the study and were assigned to two experiments. Experiment 1 included 24 participants and was designed to preliminarily examine whether S1-targeted tFUS could evoke hand-related tactile sensations. This experiment comprised two sub-experiments, Experiment 1a and Experiment 1b, with 12 participants in each. Specifically, Experiment 1a used a randomized active stimulation protocol targeting the bilateral S1 to assess the initial feasibility of inducing contralateral tactile perception, whereas Experiment 1b employed an alternating hemispheric design incorporating both active and sham stimulation to verify the specificity of the tFUS-induced sensations. Experiment 2 enrolled another 24 participants and used a real-sham dual-probe design to control for spatial tactile cues that might arise from probe-scalp contact. Five SD levels, including 200, 400, 600, 800, and 1 000 ms, were systematically tested to evaluate how stimulation duration influenced the behavioral response. The primary behavioral outcome was the perceptual consistency rate, quantified according to the accuracy of contralateral tactile localization. ResultsIn Experiment 1, 91.7% of participants reported reliable hand-related tactile sensations during active tFUS stimulation, including numbness, tingling, or similar sensory experiences. Contralateral localization accuracy under active stimulation was significantly higher than the0.50 chance level (P<0.05). In contrast, localization performance under sham stimulation did not differ from chance, suggesting that the observed tactile responses were mainly induced by active S1-targeted tFUS stimulation rather than nonspecific stimulation cues. In Experiment 2, perceptual consistency rates significantly exceeded the chance level under the 400 and 1 000 ms SD conditions(P<0.05), whereas no significant effect was observed at 200, 600, or 800 ms. Pairwise comparisons further showed that the 400 and 1 000 ms conditions produced significantly higher perceptual consistency rates than the 200 ms condition (P<0.05). ConclusiontFUS stimulation of S1 can elicit distinct hand-related tactile sensations without peripheral sensory input, demonstrating the feasibility of using targeted cortical ultrasound stimulation to induce conscious somatosensory perception. The reliability of this perceptual effect was modulated by sonication duration, indicating that temporal stimulation parameters play an important role in shaping both the occurrence and consistency of behavioral responses. Among the tested conditions, 400 ms appeared to provide a favorable temporal window for generating stable tactile perception, whereas excessively short stimulation may be insufficient to produce consistent responses. These findings highlight the sensitivity of somatosensory networks to ultrasonic modulation and provide useful parameter guidance for the application of tFUS in noninvasive sensory enhancement and cortical functional mapping.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Thermal Ablation of Pulmonary Nodules by Electromagnetic Navigation Bronchoscopy Combined With Real-Time CT-Based 3D Fusion Navigation:Report of One Case.
Yuan XU ; Qun LIU ; Chao GUO ; Yi-Bo WANG ; Xiao-Fang WU ; Chen-Xi MA ; Gui-Ge WANG ; Qian-Shu LIU ; Nai-Xin LIANG ; Shan-Qing LI
Acta Academiae Medicinae Sinicae 2025;47(1):137-141
A nodule in the right middle lobe of the lung was treated by a combination of cone-beam CT,three-dimensional registration for fusion imaging,and electromagnetic navigation bronchoscopy-guided thermal ablation.The procedure lasted for 90 min,with no significant bleeding observed under the bronchoscope.The total radiation dose during the operation was 384 mGy.The patient recovered well postoperatively,with only a small amount of blood in the sputum and no pneumothorax or other complications.A follow-up chest CT on the first day post operation showed that the ablation area completely covered the lesion,and the patient was discharged successfully.
Humans
;
Bronchoscopy/methods*
;
Catheter Ablation/methods*
;
Cone-Beam Computed Tomography
;
Electromagnetic Phenomena
;
Imaging, Three-Dimensional
;
Lung Neoplasms/diagnostic imaging*
;
Tomography, X-Ray Computed
6.A Comparative Analysis of Subtyping Methodologies on Cross-sectional sMRI Data.
Shirui ZHANG ; Baitong ZHANG ; Kun ZHAO ; Zhuangzhuang LI ; Pan WANG ; Dawei WANG ; Chengyuan SONG ; Jie LU ; Zengqiang ZHANG ; Hongxiang YAO ; Tong HAN ; Chunshui YU ; Bo ZHOU ; Ying HAN ; Xi ZHANG ; Pindong CHEN ; Yong LIU
Neuroscience Bulletin 2025;41(9):1689-1695
7.Effects of Hot Night Exposure on Human Semen Quality: A Multicenter Population-Based Study.
Ting Ting DAI ; Ting XU ; Qi Ling WANG ; Hao Bo NI ; Chun Ying SONG ; Yu Shan LI ; Fu Ping LI ; Tian Qing MENG ; Hui Qiang SHENG ; Ling Xi WANG ; Xiao Yan CAI ; Li Na XIAO ; Xiao Lin YU ; Qing Hui ZENG ; Pi GUO ; Xin Zong ZHANG
Biomedical and Environmental Sciences 2025;38(2):178-193
OBJECTIVE:
To explore and quantify the association of hot night exposure during the sperm development period (0-90 lag days) with semen quality.
METHODS:
A total of 6,640 male sperm donors from 6 human sperm banks in China during 2014-2020 were recruited in this multicenter study. Two indices (i.e., hot night excess [HNE] and hot night duration [HND]) were used to estimate the heat intensity and duration during nighttime. Linear mixed models were used to examine the association between hot nights and semen quality parameters.
RESULTS:
The exposure-response relationship revealed that HNE and HND during 0-90 days before semen collection had a significantly inverse association with sperm motility. Specifically, a 1 °C increase in HNE was associated with decreased sperm progressive motility of 0.0090 (95% confidence interval [ CI]: -0.0147, -0.0033) and decreased total motility of 0.0094 (95% CI: -0.0160, -0.0029). HND was significantly associated with reduced sperm progressive motility and total motility of 0.0021 (95% CI: -0.0040, -0.0003) and 0.0023 (95% CI: -0.0043, -0.0002), respectively. Consistent results were observed at different temperature thresholds on hot nights.
CONCLUSION
Our findings highlight the need to mitigate nocturnal heat exposure during spermatogenesis to maintain optimal semen quality.
Humans
;
Male
;
Semen Analysis
;
Adult
;
Sperm Motility
;
Hot Temperature/adverse effects*
;
China
;
Middle Aged
;
Spermatozoa/physiology*
;
Young Adult
8.NFKBIE: Novel Biomarkers for Diagnosis, Prognosis, and Immunity in Colorectal Cancer: Insights from Pan-cancer Analysis.
Chen Yang HOU ; Peng WANG ; Feng Xu YAN ; Yan Yan BO ; Zhen Peng ZHU ; Xi Ran WANG ; Shan LIU ; Dan Dan XU ; Jia Jia XIAO ; Jun XUE ; Fei GUO ; Qing Xue MENG ; Ren Sen RAN ; Wei Zheng LIANG
Biomedical and Environmental Sciences 2025;38(10):1320-1325
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Efficacy and safety of high-power,short-duration radiofrequency catheter ablation for persistent atrial fibrillation
Guang-an LIU ; Wang-long WU ; Lin-xiao ZHOU ; Jing CUI ; Bo SHAO ; Ruo-xi ZHANG ; Feng LIU
Chinese Journal of Interventional Cardiology 2025;33(5):266-271
Objective To evaluate the efficacy and safety of high-power,short-duration radiofrequency catheter ablation for the treatment of persistent atrial fibrillation.Methods This retrospective study included 392 patients diagnosed with persistent atrial fibrillation who underwent catheter radiofrequency ablation at Suzhou Kowloon Hospital,Shanghai Jiao Tong University School of Medicine,from January 2019 to December 2023.Of these,256 patients were treated with high-power,short-duration ablation,and 136 patients with low-power,long-duration ablation.The following parameters were compared:radiofrequency ablation time,total procedure time,single-circle pulmonary vein isolation rate,immediate procedural success rate,number of ablation points,and perioperative complications(including pericardial tamponade,pseudoaneurysm,arteriovenous fistula,stroke,etc.).Follow-up assessments were conducted at 3,6,and 12 months post-surgery to evaluate the 12-month sinus rhythm maintenance rate.Results The ablation time in the high-power group was significantly shorter than that in the low-power group[(14.6±2.3)min vs.(30.3±4.2)min,P<0.001],as was the total procedure time[(113.8±24.8)min vs.(128.5±26.7)min,P=0.001].There were no significant differences between the two groups in terms of pulmonary vein isolation rate(97.7%vs.94.9%,P=0.823),number of ablation points[(71.2±8.0)vs.(74.3±14.3),P=0.168],or perioperative complications(3.1%vs.4.4%,P=0.571).Regarding the maintenance rate of sinus rhythm at 12 months post-operation,the high-power group showed a higher rate than the low-power group,but no statistically significant difference was observed(82.8%vs.79.4%,P=0.399).Conclusions High-power,short-duration radiofrequency catheter ablation can improve procedural efficiency in the treatment of persistent atrial fibrillation.Its efficacy and safety are similar to those of the low-power,long-duration technique.


Result Analysis
Print
Save
E-mail