1.Assessment of health exposure risks from preservatives in beverages sold near primary schools in Anshun
XU Lin, QU Guangsheng, DAI Qian, LU Shunhua, CAI Guixiang, ZHANG Jialin, WEI Gang
Chinese Journal of School Health 2026;47(1):129-133
Objective:
To quantitatively assess the health risk of preservatives from beverages around primary schools in Anshun City, and to provide scientific basis for precise food safety supervision.
Methods:
From December 2023 to July 2024, 602 beverage samples were randomly collected from within 100 meters of 19 primary schools in Anshun City. The content of benzoic acid, sorbic acid, and dehydroacetic acid was detected according to GB 5009 series standards. Combined with children s physiological parameters (body weight 30 kg, daily intake 0.15 L), the Hazard Quotient (HQ) and Hazard Index (HI) models were used to evaluate health risks.
Results:
The total detection rate of preservatives from beverages around primary schools was 63.0%, and the total over limit rate was 9.0%. The detection rate of preservatives in flavored beverages was the highest (72.6%), and the highest over limit rate of preservatives in special purpose beverages was the highest (17.2%). The single preservative HQ (benzoic acid up to 0.47 ) and mixed HI (up to 0.55) of all samples were below 1(safety threshold). However, the HQ value of benzoic acid in flavored beverages (0.47) was 2.9 times that of sorbic acid (0.16), contributing significantly to health risk. Sensitivity analysis showed that if the daily consumption increased to 0.3 L, the HI value of flavored beverages would rise to 1.11, exceeding the safety threshold. Enterprise scale analysis showed that the exceedance rate of special purpose beverages in large enterprises reached 30.0%, while micro enterprises, accounting for a dominant market share (52.2%), constituted the main source of children s daily exposure to their products.
Conclusions
The overall health risk of perservatives in beverages sold near primary schools in Anshun City is controllable, but there is a noticeable risk of gradient. The risk of children’s exposure to preservatives through beverage consumption should not be ignored.
2.Analysis of the impact of intraoperative RhE antigen-matched transfusion on early prognosis in liver transplant patients
Xiaochao YU ; Xinyuan GAO ; Fan HAI ; Chao YANG ; Xingyu HOU ; Yaping XING ; Hongqiang GAO ; Hongwei ZHANG ; Gang SU ; Ronghua XU
Chinese Journal of Blood Transfusion 2026;39(1):44-50
Objective: To investigate the impact of RhE antigen-matched transfusion during liver transplantation on early postoperative recovery and complications. Methods: In this retrospective cohort study, ninety-five patients undergoing liver transplantation at Kunming First People's Hospital between January 2022 and July 2025 were enrolled. Patients were divided into two groups: Group 1 (RhE-mismatched transfusion, n=57) and Group 2 (RhE-matched transfusion, n=38). The baseline data, complete blood counts, hepatic and renal function, coagulation parameters, and complication rates between the two groups were compared at postoperative days 1, 3, 5, 7, and 10. Survival analysis was performed using the Kaplan-Meier method. Results: The baseline characteristics were well-balanced and comparable between the two groups (all P>0.05). The early postoperative mortality rate in the mismatched group (31.58%, 18/57) was significantly higher than that in the matched group (10.53%, 4/38) (P=0.017). The incidence of postoperative hepatic encephalopathy was significantly higher in the mismatched group (50.88%, 29/57) than in the matched group (10.53%, 4/38) (P<0.001). The incidence of postoperative haemorrhage in the mismatched group (24.56%, 14/57) was higher than that in the matched group (5.26%, 2/38), with a statistically significant difference (P=0.014). The incidence of perioperative infection in the mismatched group (28.07%, 16/57) was higher than that in the matched group (10.53%, 4/38), with a statistically significant difference (P=0.04). Corresponding odds ratios (OR) and 95% confidence intervals indicated a lower risk of these adverse events in the matched group. On postoperative day 1, the change in activated partial thromboplastin time (-1.6, 20.5) in the mismatched group was greater than in the matched group (-0.2, 5.5). The change in international normalised ratio (-0.56, 1.22) in the mismatched group was greater than in the matched group (-0.18, 0.32), while the change in albumin (-4.0, 4.8) was smaller in the mismatched group than in the matched group (-2.5, 8.8). On postoperative day 5, the change in albumin (-0.41±7.83) in the mismatched group was smaller than in the matched group (2.68±4.53). At postoperative day 7, the change in albumin in the mismatched group (-0.61±7.38) was smaller than that in the matched group (2.51±5.85), while the change in D-dimer in the mismatched group (0.73, 7.4) was greater than that in the matched group (-1.6, 4.3). On postoperative day 10, the mismatched group exhibited significantly higher fibrinogen levels (-1.21, 1.78) than the matched group (-0.49, 0.97), and significantly longer prothrombin times (-11.3, -2.7) than the matched group (-6.2, -0.8) (all P<0.05). The matched group exhibited a mean overall survival (OS) of 32.803 months (95% CI:29.171-36.436 months), significantly exceeding the mismatched group's 28.996 months (95% CI:24.202-33.790 months). The log-rank test yielded statistically significant results (χ
=4.307, P=0.038). Conclusion: Implementing RhE blood group-matched transfusion during liver transplantation may help reduce early postoperative mortality and the incidence of major complication rates, promote faster recovery of coagulation and liver function, and thereby improve short-term patient outcomes.
3.Clinical analysis of assisted reproductive technology assisted pregnancy outcome in female patients with thyroid cancer after surgery
Xiang YAO ; Wenjuan XU ; Jianye WANG ; Qun GAO ; Gang ZHAO ; Ping ZHOU
Acta Universitatis Medicinalis Anhui 2026;61(1):151-155
ObjectiveTo evaluate the pregnancy outcomes of assisted reproductive technology (ART) in women with a history of thyroid cancer who retained fertility intentions after completing cancer treatment. MethodsA retrospective analysis was performed on 61 patients with a history of thyroid cancer who underwent in vitro fertilization/intracytoplasmic sperm microinjection and embryo transfer (IVF/ICSI-ET). These patients were included as the case group. A total of 122 non-cancer patients who received ART during the same period were selected as the control group using 1∶2 matching based on age and oocyte retrieval time. Baseline characteristics, outcomes of the first ART cycle, and cumulative pregnancy outcomes were compared between the two groups. ResultsThere was no significant difference in the basic data, the total amount of gonadotropin (Gn) and the days of use between the case group and the control group (P>0.05). However, the case group had significantly fewer retrieved oocytes, mature oocytes (MII), lower fertilization and cleavage rates, and fewer transferable and high-quality embryos, as well as fewer embryos transferred during the first cycle (P < 0.05). However, there was no significant difference in the rate of first embryo implantation and first clinical pregnancy between the two groups (P>0.05). In the analysis of cumulative outcomes, the two groups did not show statistically significant differences in the cumulative pregnancy rate, clinical pregnancy rate per transfer cycle, the number of oocyte retrieval cycles required per live birth, the number of embryo transfer cycles required per live birth, and the number of embryos used for each live birth (P>0.05). However, the cumulative live birth rate was significantly lower in the case group compared to the control group (P=0.005). ConclusionAfter treatment for thyroid cancer, when ART is used to help pregnant women, the pregnancy outcome is comparable to that of women without tumors. Individualized reproductive management and timely fertility preservation strategies are recommended to optimize reproductive outcomes in this population.
4.Effects of Shujin Jiannao Formula (舒筋健脑方) on Neural Repair and PI3K-Akt-mTOR Pathway of Brain Tissue in Cerebral Palsy Model Rats
Ruiqin YU ; Yanjun MO ; Houjun ZHANG ; Gang LIU ; Zhuoluo ZHOU ; Zechen RUAN ; Lin XU ; Xiaohong MU
Journal of Traditional Chinese Medicine 2025;66(10):1038-1045
ObjectiveTo explore the possible mechanisms of Shujin Jiannao Formula (舒筋健脑方) for cerebral palsy. MethodsThirty 7-day-old SD rats were randomly divided into normal group, model group, and Shujin Jiannao Formula group, with 10 rats in each group. The model group and Shujin Jiannao Formula group established a cerebral palsy model by the classic Rice-Vannucci method. After successful modeling, rats in Shujin Jiannao Formula group were given Shujin Jiannao Formula 16 g/(kg·d) by gavage, while the normal group and model group were given normal saline 10 ml/(kg·d) by gavage once a day. After one week of intervention, the rats' body weight was measured, and Zea-Longa scores, the righting reflex test, and the hindlimb suspension test were conducted for assessment; hematoxylin-eosin (HE) staining and Nissl staining were used to observe pathological changes in brain tissue, and the number of Nissl-positive neurons was counted; enzyme-linked immunosorbent assay (ELISA) was employed to measure levels of inflammatory cytokines in the brain tissue, specifically interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α); immunofluorescence was used to detect the expression levels of neurofilament protein 200 (NF200) and myelin basic protein (MBP) in brain tissue; Western Blot analysis was conducted to determine the protein levels of phosphoinositide 3-kinase (PI3K), protein kinase B (Akt/PKB/Rac), and mammalian target of rapamycin (mTOR) in brain tissue. ResultsCompared with the normal group, rats in the model group showed significantly higher Zea-Longa scores and lower scores in the hindlimb suspension test (P<0.01); pathological findings revealed loose structure in the cerebral cortex, hippocampal atrophy, and neuronal damage in brain tissue. Levels of IL-1β and TNF-α elevated, and the number of Nissl-stained positive neurons in the cortex and hippocampal CA1 region reduced, and immunofluorescence intensity of NF200 and MBP, as well as protein expression levels of PI3K and mTOR, significantly decreased (P<0.05 or P<0.01). Compared with the model group, rats in Shujin Jiannao Formula group showed decreased Zea-Longa scores and increased hindlimb suspension test scores (P<0.05); pathological damage in brain tissue alleviated, levels of IL-1β and TNF-α reduced, the number of Nissl-stained positive neurons in the cortex and hippocampal CA1 region increased, and the immunofluorescence intensity of NF200 and MBP, as well as the protein levels of PI3K and mTOR, significantly elevated (P<0.05 or P<0.01). There were no statistically significant differences among the groups in body weight, body-turning time, or AKT protein levels in brain tissue (P>0.05). ConclusionShujin Jiannao Formula can improve the neurological function of rats with cerebral palsy, exert neurorestorative effects, and its mechanism of action may be related to the reduction of inflammatory response in brain tissue and the activation of the PI3K/AKT/mTOR signaling pathway.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Improving the Certainty of Evidence in Animal Experiment Systematic Review/Meta-Analysis: An Empirical Study of the GRADE Method
Tengfei LI ; Qingyong ZHENG ; Jianguo XU ; Yiyi LI ; Yongjia ZHOU ; Caihua XU ; Mingyue ZHANG ; Jiexiang TIAN ; Gang WANG ; Jinhui TIAN
Laboratory Animal and Comparative Medicine 2025;45(1):101-111
Animal experiments are essential tools in biomedical research, serving as a bridge between basic research and clinical trials. Systematic reviews and meta-analyses (SRs/MAs) of animal experiments are crucial methods for integrating evidence from animal experiment, which can facilitate the translation of findings into clinical research, reduce translational risks, and promote resource integration in basic research. With the continuous development of the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) methodology, its application in SRs/MAs of animal experiments has gained increasing attention. This article first outlines the principles and specific applications of the GRADE methodology in SRs/MAs of animal experiments, including qualitative descriptive systematic reviews, meta-analyses, and network meta-analyses. It then deeply analyzes the misuse of the GRADE methodology in practice, including incorrect evidence grading, improper classification of evidence, misapplication in qualitative systematic reviews, inconsistencies between the documentation of the upgrading and downgrading process and results, and inappropriate use for making recommendations. Furthermore, this article comprehensively discusses the factors influencing the grading of evidence certainty in SRs/MAs of animal experiments, including the impact of bias risk, indirectness, inconsistency, imprecision, and publication bias on evidence downgrading, as well as the role of large effect sizes and cross-species consistency in evidence upgrading. Finally, in response to the issues discussed, improvement strategies are proposed, including further research and optimization of the GRADE methodology for SRs/MAs of animal experiments, the development of reporting guidelines tailored to the characteristics of SRs/MAs in animal experiment research, and enhanced professional training for researchers in the GRADE methodology. This article aims to improve the quality of evidence in SRs/MAs of animal experiments, strengthen their reliability in clinical decision-making, and promote the more efficient translation of findings from animal experiment research into clinical practice.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.


Result Analysis
Print
Save
E-mail