1.Research Progress on the Prevention and Treatment of Intestinal Ischemia-reperfusion Injury with Traditional Chinese Medicine
Ke WU ; Zhengyu ZHANG ; Qiulin WANG ; Mengnan LIU ; Wei REN ; Wubin GUO
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(7):1801-1814
Ischemic bowel disease(IBD)is a prevalent intestinal vascular disease that poses a serious threat to patients' lives and health.Tthe key pathological process of ischemic bowel disease is intestinal ischemia-reperfusion(II/R)injury.If not diagnosed and treated in a timely manner,it can lead to life-threatening conditions such as peritonitis,intestinal gangrene perforation,and multiple organ dysfunction.Current treatments primarily focus on symptomatic and surgical interventions,lacking targeted pharmacological therapies.A substantial body of research has found that traditional Chinese medicine(TCM)exhibits a protective effect against II/R injury.This review systematically elaborated on the mechanisms by which various TCM bioactive components,including Astragaloside IV,Ginsenosides,Salvianolic acids,and Tetramethylpyrazine,as well as compound formulations such as Shenqi injection,Taoren Chengqi decoction,and Sini decoction ameliorate II/R injury.These findings provide novel research perspectives for developing TCM-based therapeutics for IBD.
2.Skin contact of cobalt and its compounds in workers of hard metal tool manufacturing enterprises
Wubin LIU ; Fangda PENG ; Chunmin ZHANG ; Yina YANG ; Chunguang DING
Journal of Environmental and Occupational Medicine 2025;42(3):349-353
Background China is the world's largest producer and consumer of cobalt. Skin exposure to excess cobalt can cause symptoms such as contact dermatitis. At present, there are few studies on skin contact of cobalt and its compounds. Objective To investigate the skin contact characteristics of cobalt and its compounds. Methods A cross-sectional study was conducted in February 2024 involving 70 workers from a hard metal tool manufacturing company and the workers were divided into four groups according to their job positions: powder mixing, sintering, automatic pressing, and grinding processing. General demographic information was collected through questionnaires. Workplace air samples were collected using personal samplers, and cobalt concentrations in workplace air were measured by inductively coupled plasma optical emission spectrometry (ICP-OES). Skin samples were collected from the workers' foreheads using cotton swabs, and urine samples were collected within 30 min after the end of their shift. Urine specific gravity was measured immediately after collection, and disqualified samples were discarded. Cobalt concentrations in the swab extracts and urine were determined by inductively coupled plasma mass spectrometry (ICP-MS). Statistical analysis was performed using Kruskal-Wallis test for multiple group comparisons, Mann-WhitneyU test for pairwise comparisons, Chi-square test for categorical variables, and Spearman's rank correlation analysis to examine the correlations among air, dermal, and urinary cobalt levels. Results The 8 h time-weighted average (TWA) cobalt concentration was (2.30±2.15) μg·m−3 (
3.Research Progress on the Prevention and Treatment of Intestinal Ischemia-reperfusion Injury with Traditional Chinese Medicine
Ke WU ; Zhengyu ZHANG ; Qiulin WANG ; Mengnan LIU ; Wei REN ; Wubin GUO
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(7):1801-1814
Ischemic bowel disease(IBD)is a prevalent intestinal vascular disease that poses a serious threat to patients' lives and health.Tthe key pathological process of ischemic bowel disease is intestinal ischemia-reperfusion(II/R)injury.If not diagnosed and treated in a timely manner,it can lead to life-threatening conditions such as peritonitis,intestinal gangrene perforation,and multiple organ dysfunction.Current treatments primarily focus on symptomatic and surgical interventions,lacking targeted pharmacological therapies.A substantial body of research has found that traditional Chinese medicine(TCM)exhibits a protective effect against II/R injury.This review systematically elaborated on the mechanisms by which various TCM bioactive components,including Astragaloside IV,Ginsenosides,Salvianolic acids,and Tetramethylpyrazine,as well as compound formulations such as Shenqi injection,Taoren Chengqi decoction,and Sini decoction ameliorate II/R injury.These findings provide novel research perspectives for developing TCM-based therapeutics for IBD.
4.Determination of 27 volatile organic compounds in exhaled breath by thermal desorption-gas chromatography-mass spectrometry
Rui GAO ; Fangda PENG ; Yazhen HE ; Jie FENG ; Wubin LIU ; Lijia YU ; Qingsong CHEN ; Chunguang DING
Journal of Environmental and Occupational Medicine 2024;41(1):96-102
Background Volatile organic compounds (VOCs) in exhaled breath are closely associated with respiratory diseases and are linked to various metabolic reactions in the human body. A quantitative analytical method can provide technical support for studying VOCs related to various diseases. Objective To establish a thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) method for the determination of 27 VOCs in exhaled breath. Methods VOCs in exhaled breath were collected using a Bio-VOC sampler and enriched with Tenax TA thermal desorption tubes before TD-GC-MS analysis. Standards were collected using thermal desorption tubes and optimized for thermal desorption conditions as well as chromatographic and mass spectrometric conditions: The separation of the 27 VOCs was achieved by an optimized temperature program, the improvement of sensitivity by optimizing quantitative ions, and the increase of VOCs desorption efficiency by optimizing thermal desorption time and temperature. Limit of detection, limit of quantification, accuracy, precision, and stability of the proposed method were investigated by spiking with a blank gas bag, and exhaled breath samples from 20 healthy individuals were collected for an application study of the proposed method. Results The thermal desorption temperature was 280 ℃, and desorption time was 6 min. A VF-624ms chromatographic column was selected for the separation of target substances. The initial temperature of heating program was 35 ℃, maintained for 1 min, and then increased to 100 ℃ at a heating rate of 3 ℃·min−1 for 1 min, followed by increasing to 210 ℃ at a heating rate of 28 ℃·min−1 for 5 min. A quantitative analysis was conducted with a single ion monitoring (SIM) mode. Under these conditions, the 27 VOCs showed good linear relationships in their respective concentration ranges and the correlation coefficients were higher than 0.9990. The limits of detection of the method were in the range of 0.01-0.13 nmol·mol−1, the limits of quantification were in the range of 0.02-0.44 nmol·mol−1, and the spiked recoveries were in the range of 80.1%-120.5%, with intra-batch and inter-batch precision ≤ 18.8% and 17.9% respectively. All substances can be stored at room temperature (23-28 °C) for 7 d and at 4 °C for 14 d. The proposed method was applied to exhaled breath samples from 20 subjects with detection rates≥ 80% (except for trans-2-pentene and decane) and a concentration range of 0.00-465.50 nmol·mol−1. Conclusion The established TD-GC-MS method for quantification of VOCs in exhaled breath is characterized by high sensitivity and good accuracy, and is suitable for quantitative determination of VOCs in exhaled breath, which can provide technical support for the study of exhaled breath VOCs.
5.Anticancer Mechanism of Hesperidin and Its Derivatives: A Review
Xiurong TIAN ; Hao WANG ; Penglong YU ; Shimeng LYU ; Yonghua LI ; Xianglin JIANG ; Qin YANG ; Wubin LYU ; Xia LIU ; Yuexiang MA
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(13):259-270
This article reviews relevant literature on the prevention and treatment of cancer with hesperidin published in the past 10 years by searching electronic databases such as China National Knowledge Infrastructure(CNKI), Wanfang, and PubMed, and summarizes the research progress on the anticancer mechanism of hesperidin. Hesperidin has a wide range of pharmacological effects, including anti-inflammatory, antioxidant, antibacterial, antiviral, anticancer, immune-regulatory, anti-radiation, neuroprotective and cardiovascular protective properties and so on. Its anticancer mechanisms mainly include inhibiting cancer cell proliferation, promoting apoptosis, reducing angiogenesis, inhibiting invasion and migration of cancer cells, regulating immunity and autophagy, and exerting antioxidant and anti-inflammatory effects. As a broad-spectrum anticancer drug, hesperidin manifests chemo-preventive and therapeutic effects across various cancers, contingent upon its multifaceted anticancer mechanisms. Furthermore, this article summarizes the synergistic effects of hesperidin in combination with cisplatin, doxorubicin, cyclophosphamide and paclitaxel. It elucidates that hesperidin can enhance the cytotoxicity of these anticancer drugs against cancer cells while mitigating drug resistance and adverse side effects. Nonetheless, the clinical use is somewhat constrained due to its poor water solubility and limited bioavailability. Therefore, this article also outlines the current strategies for enhancing hesperidin's bioavailability, including structural modification, combination with other chemical substances, and utilization of nano drug carriers.The discovery of derivatives of hesperidin not only preserves the anticancer efficacy of hesperidin, but also effectively overcomes the shortcomings of poor water solubility and low bioavailability of hesperidin, effectively predicting the good application prospects of hesperidin and its derivatives.
6.Determination of Perchloroethylene in blood by headspace gas chromatography-mass spectrometry
Jie FENG ; Wubin LIU ; Yan LI ; Chunguang DING
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(1):42-46
Objective:To establish a method for determination of Perchloroethylene (PCE) in blood by headspace gas chromatography-mass spectrometry (HS/GC-MS) .Methods:From Dctober to December 2021, A total of 3 mL blood samples were taken into a 10 mL headspace bottle, after heated at 60 ℃ for 30 mins, PCE in the top air was separated by VF-WAXms capillary column and detected by GC-MS. The retention time and external standard method were used for qualitative and quantitative analysis of PCE in samples, respectively.Results:There was good linear relationship in the range of 5.09-200.17 μg/L. The linear correlation coefficient was 0.9993.The detection limit was 0.21 μg/L and the lower limit of quantitation was 0.70 μg/L. The recovery rates of samples with different concentrations were 95.3%-103.8%. The intra-batch relative standard deviations ( RSD) were 3.2%-4.6%, and inter-batch RSD was 4.0%-6.1%. The samples can be stored at 4 ℃ for three days and at -20 ℃ for seven days. Conclusion:This method is proved to be simple, practical and highly sensitive, which is suitable for the determination of PCE in blood.
7.Determination of Perchloroethylene in blood by headspace gas chromatography-mass spectrometry
Jie FENG ; Wubin LIU ; Yan LI ; Chunguang DING
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(1):42-46
Objective:To establish a method for determination of Perchloroethylene (PCE) in blood by headspace gas chromatography-mass spectrometry (HS/GC-MS) .Methods:From Dctober to December 2021, A total of 3 mL blood samples were taken into a 10 mL headspace bottle, after heated at 60 ℃ for 30 mins, PCE in the top air was separated by VF-WAXms capillary column and detected by GC-MS. The retention time and external standard method were used for qualitative and quantitative analysis of PCE in samples, respectively.Results:There was good linear relationship in the range of 5.09-200.17 μg/L. The linear correlation coefficient was 0.9993.The detection limit was 0.21 μg/L and the lower limit of quantitation was 0.70 μg/L. The recovery rates of samples with different concentrations were 95.3%-103.8%. The intra-batch relative standard deviations ( RSD) were 3.2%-4.6%, and inter-batch RSD was 4.0%-6.1%. The samples can be stored at 4 ℃ for three days and at -20 ℃ for seven days. Conclusion:This method is proved to be simple, practical and highly sensitive, which is suitable for the determination of PCE in blood.
8.Evaluation of the determination of hydrogen sulfide in the air of workplace by the detection tube method
Jing DAI ; Wubin LIU ; Chen WANG ; Haifeng DENG ; Huifang YAN ; Chunguang DING
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(9):676-680
Objective:To evaluate the accuracy and applicability of detection tube method for quantitative detection of hydrogen sulfide in workplace air.Methods:In September 2021, the lower limit of quantification, accuracy, precision, environmental factors, interfering gases and other performance indicators of the method for determining hydrogen sulfide in the air of workplace were verified by the detection tube, and the results were compared with those of GB 11742-89 "Standard method for hygienic examination of hydrogen sulfide in air of residential areas-methylene blue spectrophotometric method" to evaluate the application effect of the detection tube method for quantitative detection of hydrogen sulfide in workplace air.Results:There was no significant difference in the results of 2.83 mg/m 3, 4.25 mg/m 3 and 17.00 mg/m 3 hydrogen sulfide concentration between the two methods ( P>0.05) , but there was significant difference in the results of 8.50 mg/m 3 concentration ( P<0.05) . The lower limit of quantification of hydrogen sulfide in workplace air was 2.83 mg/m 3, the accuracy was 96.0%-111.0%, and the precision was 0.70%-6.64%. Under the condition of 4 ℃, the measured results decreased by 3.39%-13.10%. When the humidity was 50%-80%, the relative error of the average measured value was -1.67%-4.44%. Interference gases that may exist in the workplace (including carbon dioxide, carbon monoxide, mercaptans, nitrogen oxides, sulfur dioxide, etc.) did not interfere with the results of the test tube. Conclusion:The accuracy and precision of the detection tube method meet the detection requirements. The method is simple, rapid and easy to be popularized, and can be used for the rapid detection of hydrogen sulfide gas concentration in the workplace.
9.Evaluation of the determination of hydrogen sulfide in the air of workplace by the detection tube method
Jing DAI ; Wubin LIU ; Chen WANG ; Haifeng DENG ; Huifang YAN ; Chunguang DING
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(9):676-680
Objective:To evaluate the accuracy and applicability of detection tube method for quantitative detection of hydrogen sulfide in workplace air.Methods:In September 2021, the lower limit of quantification, accuracy, precision, environmental factors, interfering gases and other performance indicators of the method for determining hydrogen sulfide in the air of workplace were verified by the detection tube, and the results were compared with those of GB 11742-89 "Standard method for hygienic examination of hydrogen sulfide in air of residential areas-methylene blue spectrophotometric method" to evaluate the application effect of the detection tube method for quantitative detection of hydrogen sulfide in workplace air.Results:There was no significant difference in the results of 2.83 mg/m 3, 4.25 mg/m 3 and 17.00 mg/m 3 hydrogen sulfide concentration between the two methods ( P>0.05) , but there was significant difference in the results of 8.50 mg/m 3 concentration ( P<0.05) . The lower limit of quantification of hydrogen sulfide in workplace air was 2.83 mg/m 3, the accuracy was 96.0%-111.0%, and the precision was 0.70%-6.64%. Under the condition of 4 ℃, the measured results decreased by 3.39%-13.10%. When the humidity was 50%-80%, the relative error of the average measured value was -1.67%-4.44%. Interference gases that may exist in the workplace (including carbon dioxide, carbon monoxide, mercaptans, nitrogen oxides, sulfur dioxide, etc.) did not interfere with the results of the test tube. Conclusion:The accuracy and precision of the detection tube method meet the detection requirements. The method is simple, rapid and easy to be popularized, and can be used for the rapid detection of hydrogen sulfide gas concentration in the workplace.
10.Combined G-banded karyotyping and multiplex ligation-dependent probe amplification for the detection of chromosomal abnormalities in fetuses with congenital heart defects.
Yang LIU ; Jiansheng XIE ; Qian GENG ; Zhiyong XU ; Weiqin WU ; Fuwei LUO ; Suli LI ; Qin WANG ; Wubin CHEN ; Hongxi TAN ; Hu ZHANG
Chinese Journal of Medical Genetics 2017;34(1):1-5
OBJECTIVETo assess the value of G-banded karyotyping in combination with multiplex ligation-dependent probe amplification (MLPA) as a tool for the detection of chromosomal abnormalities in fetuses with congenital heart defects.
METHODSThe combined method was used to analyze 104 fetuses with heart malformations identified by ultrasonography. Abnormal findings were confirmed with chromosomal microarray analysis (CMA).
RESULTSNineteen (18%) fetuses were found to harbor chromosomal aberrations by G-banded karyotyping and MLPA. For 93 cases, CMA has detected abnormalities in 14 cases including 10 pathogenic copy number variations (CNVs) and 4 CNVs of uncertain significance (VOUS). MLPA was able to detect all of the pathogenic CNVs and 1 VOUS CNV.
CONCLUSIONCombined use of G-banded karyotyping and MLPA is a rapid, low-cost and effective method to detect chromosomal abnormalities in fetuses with various heart malformations.
Chromosome Aberrations ; Chromosome Banding ; Chromosome Disorders ; diagnosis ; genetics ; DNA Copy Number Variations ; Female ; Fetal Diseases ; diagnosis ; genetics ; Genetic Testing ; methods ; Heart Defects, Congenital ; diagnosis ; genetics ; Humans ; Karyotyping ; methods ; Multiplex Polymerase Chain Reaction ; methods ; Pregnancy ; Prenatal Diagnosis ; methods ; Reproducibility of Results ; Sensitivity and Specificity

Result Analysis
Print
Save
E-mail