1.Wrist arthroscopic Wafer surgery combined with triangular fibrocartilage complex insertion point reconstruction in treatment of Palmer type ⅡC combined with type ⅠB ulnar impingement syndrome.
Yong LI ; Mingming MA ; Xiaojun RUAN ; Yongbin FU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):59-63
OBJECTIVE:
To investigate the effectivess of arthroscopic Wafer surgery combined with triangular fibrocartilage complex (TFCC) insertion point reconstruction in the treatment of Palmer type ⅡC combined with typeⅠB ulnar impingement syndrome.
METHODS:
The clinical data of 14 patients with Parlmer type ⅡC combined with type ⅠB ulnar impingement syndrome who met the selection criteria between July 2021 and April 2024 were retrospectively analyzed. There were 7 males and 7 females with an average age of 43 years ranging from 16 to 59 years. The causes of injury were fall in 8 cases and sprain in 6 cases. The time from injury to operation ranged from 1 to 6 months, with an average of 2.3 months. Distal radioulnar joint instability was found in all cases. Arthroscopic Wafer surgery combined with TFCC insertion point reconstruction was used. The effectiveness was evaluated by comparing the wrist flexion-dorsiflexion range of motion, wrist ulnar deviation-radial deflection range of motion, forearm pronation-supination range of motion, visual analogue scale (VAS) score, and modified Mayo wrist score before and after operation.
RESULTS:
All patients were followed up 6-12 months, with an average of 9.1 months. The positive variation of ulna was (3.2±0.7) mm before operation, and the negative variation of ulna was (2.2±0.6) mm after operation. There was a significant difference in ulna variation between pre- and post-operation ( t=23.851, P<0.001). The pain symptoms and forearm rotation function of the patients after operation significantly improved. At last follow-up, the wrist flexion-dorsiflexion range of motion, wrist ulnar deviation-radial deflection range of motion, forearm pronation-supination range of motion, VAS score, and modified Mayo wrist score significantly improved when compared with those before operation ( P<0.05).
CONCLUSION
Arthroscopic Wafer surgery combined with TFCC insertion point reconstruction can effectively relieve wrist pain, enhance the stability of the distal radioulnar joint, and restore the function of the wrist in patients with Palmer type ⅡC combined with type ⅠB ulnar impingement syndrome.
Humans
;
Male
;
Adult
;
Arthroscopy/methods*
;
Female
;
Triangular Fibrocartilage/surgery*
;
Middle Aged
;
Range of Motion, Articular
;
Retrospective Studies
;
Wrist Joint/physiopathology*
;
Adolescent
;
Young Adult
;
Ulna/surgery*
;
Treatment Outcome
;
Wrist Injuries/surgery*
;
Plastic Surgery Procedures/methods*
;
Joint Instability/surgery*
2.Treatment of rheumatoid arthritis of wrist using Ilizarov wrist joint distraction technique: a case report.
Bin WANG ; Guizu GAO ; Yongxin HUO ; Huanyou YANG ; Jiale JIANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):462-465
OBJECTIVE:
To report the clinical experience of using Ilizarov wrist joint distraction technique in the treatment of a case of rheumatoid arthritis of the wrist.
METHODS:
In January 2019, a 49-year-old female patient with rheumatoid arthritis of the left wrist, complicated by ulnar impaction syndrome, was admitted for treatment. Preoperatively, the active range of motion of the left wrist was as follows: extension 0°-flexion 0°, pronation 65°-supination 35°, and grip strength of 4.0 kg. The visual analogue scale (VAS) score was 9, and the Cooney wrist function score was 15, indicating poor function. As conservative treatment failed to achieve symptom relief, Ilizarov wrist joint distraction surgery was performed. Postoperatively, joint distraction was applied at 2 mm increments on postoperative days 2 and 7, in 4 separate sessions.
RESULTS:
Postoperative X-ray film examination at 7 days revealed a distraction of 3.6 mm in the affected wrist joint compared to the contralateral side. The external fixator was removed 2.5 months postoperatively. At 22 months postoperatively, X-ray film and MRI examinations revealed that the joint space of the left wrist had returned to near-normal, with significant reduction in joint effusion and synovial proliferation. The active range of motion of the left wrist improved to extension 15°- flexion 30°, pronation 90°-supination 90°, with a grip strength of 18.0 kg. The wrist pain VAS score decreased to 0, and the Cooney wrist function score improved to 90, indicating excellent function. At 50 months postoperatively, follow-up X-ray film, MRI, and functional assessments showed the results similar to those at 22 months.
CONCLUSION
Ilizarov wrist joint distraction may be a viable treatment option for rheumatoid arthritis of the wrist.
Humans
;
Female
;
Middle Aged
;
Wrist Joint/physiopathology*
;
Arthritis, Rheumatoid/physiopathology*
;
Range of Motion, Articular
;
Ilizarov Technique
;
Treatment Outcome
;
Osteogenesis, Distraction/methods*
3.Three-dimentional printed personalized guide plate-assisted wrist arthroscopic repair of Palmer type ⅠB triangular fibrocartilage complex injury.
Jin LI ; Zhaoming ZHANG ; Lilian ZHAO ; Lilei HE ; Changbing WANG ; Yanjin LI ; Ting XU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1409-1413
OBJECTIVE:
To investigate the effectiveness of three-dimentional (3D) printed personalized guide plate-assisted wrist arthroscopic repair for Palmer type ⅠB triangular fibrocartilage complex (TFCC) injury.
METHODS:
A retrospective analysis was conducted on the clinical data of 20 patients with Palmer type ⅠB TFCC injuries admitted between January 2023 and March 2024 who met the selection criteria. Among them, 13 were male and 7 were female; ages ranged from 23 to 35 years, with a mean age of 30.3 years. All patients had a history of trauma, 12 cases involved falls and 8 cases involved sprains. All patients demonstrated a positive "piano key sign". MRI revealed deep ulnar-side tears of the TFCC. Conservative treatment for 6 weeks yielded poor or no clinical improvement. The interval from injury to surgery ranged from 2 to 9 months, with a mean of 5.0 months. Patients underwent wrist arthroscopic repair assisted by 3D printed personalized guide plate. Functional recovery was assessed preoperatively and postoperatively using the visual analogue scale (VAS) score for pain, modified Mayo wrist score, and range of motion (ROM) measurements for wrist flexion-extension, ulnar-radial deviation, and pronation-supination. At last follow-up, MRI was performed to evaluate the healing of TFCC.
RESULTS:
All 20 patients underwent successful surgery without complications such as vascular or nerve injury, fracture, incisional infection, or joint stiffness. All patients were followed up 9-18 months (mean, 12.4 months). At last follow-up, patients demonstrated significant improvements in VAS scores, modified Mayo wrist scores, wrist flexion-extension ROM, ulnar-radial deviation ROM, and pronation-supination ROM compared to preoperative levels ( P<0.05). MRI at last follow-up showed preserved TFCC continuity, excellent healing, and secure fixation.
CONCLUSION
3D-printed personalized guide plate significantly improve outcomes in wrist arthroscopic TFCC repair for Palmer type ⅠB injuries. They enable high-quality suturing, facilitate anatomical reconstruction, and markedly enhance wrist function.
Humans
;
Arthroscopy/methods*
;
Male
;
Adult
;
Triangular Fibrocartilage/diagnostic imaging*
;
Female
;
Retrospective Studies
;
Printing, Three-Dimensional
;
Wrist Injuries/diagnostic imaging*
;
Young Adult
;
Bone Plates
;
Treatment Outcome
;
Wrist Joint/surgery*
;
Magnetic Resonance Imaging
;
Range of Motion, Articular
4.Application of custom-made joint prostheses in wrist.
Xiaodi ZOU ; Yanzhao DONG ; Changxing WANG ; Hui LU
Journal of Zhejiang University. Science. B 2025;26(2):200-202
The wrist joint is a highly mobile functional joint. Wrist conditions including traumatic and degenerative arthritis, rheumatoid arthritis, and giant cell tumors of the distal radius, cause significant pain and mobility impairment. In joint surgery, the decision to use joint prostheses to reconstruct joint function is greatly influenced by the characteristics of the prosthesis (Mok et al., 2016). However, traditional implants have limitations such as shape mismatch, inadequate implant-bone interface strength which causes loosening, and poor bone ingrowth (Zhang et al., 2014).
Humans
;
Joint Prosthesis
;
Wrist Joint/surgery*
;
Prosthesis Design
;
Arthroplasty, Replacement
;
Arthritis, Rheumatoid/surgery*
5.Effect of Wrist-Ankle Acupuncture on Postoperative Analgesia after Total Knee Arthroplasty.
Hai-Tao CAO ; Wan ZHANG ; Cheng LUO ; Hong-Bo ZHAO ; Jian-Ming LIU
Chinese journal of integrative medicine 2023;29(3):253-257
OBJECTIVE:
To evaluate the effect of wrist-ankle acupuncture (WAA) in pain and functional recovery after total knee arthroplasty (TKA).
METHODS:
From June to September 2020, 94 participants were included from the Second Hospital of Tangshan and randomly assigned to the WAA group (47 cases) and the sham WAA group (47 cases) by a random number table, receiving real or sham WAA treatment, respectively. The primary outcome measure involved the visual analogue scale (VAS) scores at rest and in motion. The secondary outcomes involved the range of motion (ROM) of the knee joints, straight-leg raising time, postoperative weight-bearing time, sufentanil consumption within 48 h of patient-controlled analgesia (PCA) pump, length of hospital stay, and postoperative complications.
RESULTS:
The VAS scores on the 3rd, 5th, and 7th postoperative days at rest and in motion was significantly lower in the WAA group than that of the sham WAA group (P<0.01). The ROM on the 1st, 2nd, and 3rd PODs was significantly higher in the WAA group than that of the sham WAA group (P<0.01). In comparison to the sham WAA group, the sufentanil consumption within 48 h of PCA pump was significantly less in the WAA group (156.3 ± 12.2 µg vs. 128.8 ± 9.8 µg, P<0.01). There was no significant difference in active straight-leg raising time, postoperative weight-bearing time, length of hospital stay, and postoperative complications between the two groups (P>0.05).
CONCLUSIONS
WAA could alleviate post-TKA pain, improve knee joint function, and reduce the sufentanil consumption within 48 h of PCA pump. WAA is a safe and effective treatment in the perioperative analgesic management for TKA.
Humans
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Ankle
;
Wrist
;
Sufentanil
;
Pain, Postoperative/therapy*
;
Acupuncture Therapy/adverse effects*
;
Analgesia
;
Knee Joint
6.Analysis of the effectiveness of sequential plate internal fixation in correction of Madelung deformity after ulnar osteotomy and shortening.
Wei WANG ; Xiaowen DENG ; Wenbo LI ; Miaomiao YANG ; Yaqiang ZHANG ; Peisheng SHI ; Weiwei SHEN ; Rui LIU ; Jie SHI ; Chuangbing LI ; Yun XUE ; Qiuming GAO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):810-814
OBJECTIVE:
To investigate the effectiveness of sequential plate internal fixation in the correction of Madelung deformity after ulnar osteotomy and shortening.
METHODS:
The clinical data of 13 patients with Madelung deformity admitted between September 2015 and July 2021 were retrospectively analyzed. There were 5 males and 8 females with an average age of 18.3 years ranging from 17 to 23 years. The disease duration ranged from 12 to 24 months, with an average of 17 months. Three cases had a clear history of trauma. All patients had external radial deviation deformity and limited movement of the ulnar deviation, and the ulnar impact pain was significant during ulnar deviation movement; 9 patients had limited wrist joint supination movement, and the supination movement was normal. In the first stage, ulnar osteotomy and shortening combined with external fixator were used to correct wrist deformity in 13 patients. After operation, bone transfer was performed 6 times per day, with adjustments made every 4 hours, which was 1 mm per day. After the osteotomy was in place, the ulnar plate internal fixation was performed to reconstruct the ulnar stability in the second stage. The Cooney wrist joint score was used to assess the pain, function, range of motion, flexion and extension range of motion, and grip strength of the wrist joint before operation and before the removal of internal fixator. The subjective feeling and appearance satisfaction of patients were recorded.
RESULTS:
After the second-stage operation, all the 13 patients were followed up 10-22 months, with an average of 15 months. The deformity of wrist joint disappeared after operation, and the flexion, extension, and ulnar deviation were basically normal. There was no complication such as ulnar impingement sign, nonunion or infection. Wrist function, pain, and range of motion were significantly improved after operation, except for 1 patient who had no significant improvement in rotation and pain. The ulnar internal fixator was removed at 10-18 months after the second-stage operation. The scores of pain, function, range of motion, flexion and extension range of motion, and grip strength in the Cooney wrist score before removal of internal fixator significantly improved when compared with those before operation ( P<0.05). Subjective and appearance satisfaction of patients were excellent in 9 cases, good in 3 cases, and fair in 1 case.
CONCLUSION
Ulnar osteotomy and shortening with sequential plate internal fixation for correction of Madelung deformity, with mild postoperative pain, can effectively avoid bone nonunion, improve wrist joint function, and have significant effectiveness.
Male
;
Female
;
Humans
;
Adolescent
;
Retrospective Studies
;
Ulna/surgery*
;
Osteochondrodysplasias
;
Radius Fractures/surgery*
;
Wrist Joint/surgery*
;
Osteotomy
;
Range of Motion, Articular
;
Treatment Outcome
7.Clinical analysis of distal radius core decompression for chronic wrist pain.
Jixin WU ; Jiayu SUN ; Xin LIU ; Jie SONG ; Shaonan HU ; Liang CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):815-820
OBJECTIVE:
To investigate the effectiveness of distal radius core decompression in the treatment of chronic wrist pain caused by various etiologies.
METHODS:
A retrospective analysis was performed for the clinical data of 10 patients with chronic wrist pain treated with distal radial core decompression between January 2018 and December 2021. There were 6 males and 4 females with an average age of 37.4 years (range, 21-55 years). The disease duration ranged from 7 to 72 months, with an average of 26.5 months. Preoperative MRI examination showed that 10 cases had bone marrow edema at the distal radius on the affected side, and 8 cases had bone marrow edema in the carpal bones such as scaphoid and lunate bone. Among them, 3 patients had a history of wrist fracture, and 2 patients had Kienböck diseases (1 case each in stage ⅡB and stage ⅢA). Three cases were combined with triangular fibrocartilage complex (TFCC) type 1A injury. Two cases were combined with osteoarthritis, 1 of them was complicated with severe traumatic arthritis, the wrist arthroscopy showed that the TFCC was completely lost and could not be repaired, and the cartilage of the lunate bone and the ulnar head were severely worn.Visual analogue scale (VAS) score was used to evaluate the relief of wrist pain before operation, at 6 months after operation, and at last follow-up, and the range of motion of the affected wrist in dorsiflexion, palmar flexion, ulnar deviation, and radial deviation was measured. The degree of bone marrow edema was evaluated according to T1WI, T2WI, and STIR sequences of MRI.
RESULTS:
All the patients were followed up 12-22 months, with an average of 16.4 months. Except for 1 patient who experienced persistent wrist joint pain and limited mobility after operation, the remaining 9 patients showed significant improvement in pain symptoms and wrist joint mobility. The VAS score and range of motion of wrist dorsiflexion, palmar flexion, ulnar deviation, and radial deviation at 6 months after operation and at last follow-up were significantly improved when compared with those before operation, the VAS score and the range of motion of wrist ulnar deviation and radial deviation at last follow-up were further improved when compared with those at 6 months after operation, all showing significant differences ( P<0.05). There was no significant difference in wrist dorsiflexion and palmar flexion between at 6 months after operation and at last follow-up ( P>0.05). Bone marrow edema was improved in 6 patients on MRI at 6 months after operation, and was also improved in other patients at last follow-up.
CONCLUSION
For chronic wrist pain caused by a variety of causes, distal radius core decompression can directly reduce the pressure of the medullary cavity of the distal radius, improve the blood supply of the corresponding distal structure, significantly alleviate chronic wrist pain, and provide an option for clinical treatment.
Male
;
Female
;
Humans
;
Adult
;
Radius/surgery*
;
Wrist
;
Retrospective Studies
;
Radius Fractures/surgery*
;
Wrist Joint/surgery*
;
Scaphoid Bone/surgery*
;
Pain
;
Arthralgia/complications*
;
Arthroscopy
;
Decompression
;
Range of Motion, Articular
;
Treatment Outcome
8.Three-dimensional finite element model construction and biomechanical analysis of customized titanium alloy lunate prosthesis.
Bin WANG ; Xingbo CAI ; Yue ZHANG ; Bihuan ZHANG ; Yongqing XU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):821-826
OBJECTIVE:
To design customized titanium alloy lunate prosthesis, construct three-dimensional finite element model of wrist joint before and after replacement by finite element analysis, and observe the biomechanical changes of wrist joint after replacement, providing biomechanical basis for clinical application of prosthesis.
METHODS:
One fresh frozen human forearm was collected, and the maximum range of motions in flexion, extension, ulnar deviation, and radialis deviation tested by cortex motion capture system were 48.42°, 38.04°, 35.68°, and 26.41°, respectively. The wrist joint data was obtained by CT scan and imported into Mimics21.0 software and Magics21.0 software to construct a wrist joint three-dimensional model and design customized titanium alloy lunate prosthesis. Then Geomagic Studio 2017 software and Solidworks 2017 software were used to construct the three-dimensional finite element models of a normal wrist joint (normal model) and a wrist joint with lunate prosthesis after replacement (replacement model). The stress distribution and deformation of the wrist joint before and after replacement were analyzed for flexion at and 15°, 30°, 48.42°, extension at 15°, 30°, and 38.04°, ulnar deviation at 10°, 20°, and 35.68°, and radial deviation at 5°, 15°, and 26.41° by the ANSYS 17.0 finite element analysis software. And the stress distribution of lunate bone and lunate prosthesis were also observed.
RESULTS:
The three-dimensional finite element models of wrist joint before and after replacement were successfully constructed. At different range of motion of flexion, extension, ulnar deviation, and radial deviation, there were some differences in the number of nodes and units in the grid models. In the four directions of flexion, extension, ulnar deviation, and radial deviation, the maximum deformation of wrist joint in normal model and replacement model occurred in the radial side, and the values increased gradually with the increase of the range of motion. The maximum stress of the wrist joint increased gradually with the increase of the range of motion, and at maximum range of motion, the stress was concentrated on the proximal radius, showing an overall trend of moving from the radial wrist to the proximal radius. The maximum stress of normal lunate bone increased gradually with the increase of range of motion in different directions, and the stress position also changed. The maximum stress of lunate prosthesis was concentrated on the ulnar side of the prosthesis, which increased gradually with the increase of the range of motion in flexion, and decreased gradually with the increase of the range of motion in extension, ulnar deviation, and radialis deviation. The stress on prosthesis increased significantly when compared with that on normal lunate bone.
CONCLUSION
The customized titanium alloy lunate prosthesis does not change the wrist joint load transfer mode, which provided data support for the clinical application of the prosthesis.
Humans
;
Lunate Bone/surgery*
;
Finite Element Analysis
;
Titanium
;
Wrist Joint/surgery*
;
Artificial Limbs
;
Range of Motion, Articular
;
Biomechanical Phenomena
9.Double-column Die-punch fractures of distal radius treated with butterfly plate fixation via Henry approach.
Hai-Bo XIA ; Jun LAN ; Li-Qing JIANG ; Hua-Fei YANG ; Xiao-Hui NIU
China Journal of Orthopaedics and Traumatology 2023;36(4):376-380
OBJECTIVE:
To explore clinical effect of open reduction and internal fixation with Henry's approach butterfly plate in treating double-column Die-punch fractures of distal radius.
METHODS:
From January 2018 to June 2021, 26 patients with double-column Die-column distal radius were treated with open reduction and internal fixation through Henry's surgical approach and using distal radius volar column plate(butterfly plate), including 14 males and 12 females, aged from 20 to 75 years old with an average age of (44.2±3.4) years old. Postopertaive complications were observed, Gartland-Werley score at 12 months after opertaion was used to evaluate wrist joint function.
RESULTS:
All 26 patients were followed up from 10 to 18 months with an average of(13.4±0.8) months. All fractures were obtained fracture union, the time ranged from 8.5 to 15.8 weeks with an average of (11.4±0.5) weeks. All incisions healed at stageⅠwithout infection, nerve injury and internal fixation failure occurred. Postoperative Gartland-Werley score at 12 months was (3.65±0.36), and 16 patients got excellent result, 8 good and 2 moderate.
CONCLUSION
Open reduction and internal fixation with butterfly plate for the treatment of double-column Die-punch fractures of the distal radius through volar Henry approach could obtain satisfactory clinical outcomes.
Adult
;
Aged
;
Animals
;
Female
;
Humans
;
Male
;
Middle Aged
;
Young Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
Radius/surgery*
;
Radius Fractures/surgery*
;
Range of Motion, Articular
;
Treatment Outcome
;
Wrist Joint
10.The analysis of the therapeutic effect for 10 cases of type C extreme distal radial fracture in micro needle plate internal fixation.
Bing LIU ; Xiang-Yu MA ; Chao YANG ; Da-Peng ZHOU
China Journal of Orthopaedics and Traumatology 2023;36(6):574-578
OBJECTIVE:
To analyze the clinical outcomes of mini-plate combined with wireforms in the treatment of Type C distal radial fractures with marginal articular fragments.
METHODS:
This retrospective study included a total of 10 cases, including 5 males and 5 females, with 6 cases involving the left side and 4 cases involving the right side, of Type C distal radial fractures with marginal articular fragments. The age of the patients ranged from 35 to 67 years old. All patients underwent surgical treatment utilizing mini-plate combined with wireforms for internal fixation.
RESULTS:
The follow-up period ranged from 6 to 18 months. Complete fracture healing was observed in all cases, with healing times ranging from 10 to 16 weeks. During the entire follow-up period, patients reported high levels of satisfaction with the treatment outcomes, and there were no incidences of incision infection, chronic wrist pain, or wrist traumatic arthritis. At the final follow-up assessment, the Mayo score for the wrist joint ranged from 85 to 95, with 7 cases rated as excellent and 3 cases as good.
CONCLUSION
Mini-plate combined with wireforms proves to be an effective fixation method for Type C distal radial fractures with marginal articular fragments. The early initiation of wrist joint exercises, strong fixation, maintenance of proper reduction, minimal complications, and high rates of excellent and good outcomes demonstrate the reliability and efficacy of this treatment approach.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Retrospective Studies
;
Reproducibility of Results
;
Radius Fractures/surgery*
;
Fracture Fixation, Internal/methods*
;
Treatment Outcome
;
Wrist Fractures
;
Wrist Joint
;
Bone Plates
;
Range of Motion, Articular

Result Analysis
Print
Save
E-mail