1.Wrist arthroscopic Wafer surgery combined with triangular fibrocartilage complex insertion point reconstruction in treatment of Palmer type ⅡC combined with type ⅠB ulnar impingement syndrome.
Yong LI ; Mingming MA ; Xiaojun RUAN ; Yongbin FU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):59-63
OBJECTIVE:
To investigate the effectivess of arthroscopic Wafer surgery combined with triangular fibrocartilage complex (TFCC) insertion point reconstruction in the treatment of Palmer type ⅡC combined with typeⅠB ulnar impingement syndrome.
METHODS:
The clinical data of 14 patients with Parlmer type ⅡC combined with type ⅠB ulnar impingement syndrome who met the selection criteria between July 2021 and April 2024 were retrospectively analyzed. There were 7 males and 7 females with an average age of 43 years ranging from 16 to 59 years. The causes of injury were fall in 8 cases and sprain in 6 cases. The time from injury to operation ranged from 1 to 6 months, with an average of 2.3 months. Distal radioulnar joint instability was found in all cases. Arthroscopic Wafer surgery combined with TFCC insertion point reconstruction was used. The effectiveness was evaluated by comparing the wrist flexion-dorsiflexion range of motion, wrist ulnar deviation-radial deflection range of motion, forearm pronation-supination range of motion, visual analogue scale (VAS) score, and modified Mayo wrist score before and after operation.
RESULTS:
All patients were followed up 6-12 months, with an average of 9.1 months. The positive variation of ulna was (3.2±0.7) mm before operation, and the negative variation of ulna was (2.2±0.6) mm after operation. There was a significant difference in ulna variation between pre- and post-operation ( t=23.851, P<0.001). The pain symptoms and forearm rotation function of the patients after operation significantly improved. At last follow-up, the wrist flexion-dorsiflexion range of motion, wrist ulnar deviation-radial deflection range of motion, forearm pronation-supination range of motion, VAS score, and modified Mayo wrist score significantly improved when compared with those before operation ( P<0.05).
CONCLUSION
Arthroscopic Wafer surgery combined with TFCC insertion point reconstruction can effectively relieve wrist pain, enhance the stability of the distal radioulnar joint, and restore the function of the wrist in patients with Palmer type ⅡC combined with type ⅠB ulnar impingement syndrome.
Humans
;
Male
;
Adult
;
Arthroscopy/methods*
;
Female
;
Triangular Fibrocartilage/surgery*
;
Middle Aged
;
Range of Motion, Articular
;
Retrospective Studies
;
Wrist Joint/physiopathology*
;
Adolescent
;
Young Adult
;
Ulna/surgery*
;
Treatment Outcome
;
Wrist Injuries/surgery*
;
Plastic Surgery Procedures/methods*
;
Joint Instability/surgery*
2.Effectiveness analysis of tension band-assisted fixation for volar marginal fractures of distal radius.
Abulimiti MIREADELI ; Wanming QU ; Tianbo ZHU ; Daoxin ZHANG ; Xiaokang ZHU ; Xinzhi LI ; Wenyao CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):662-667
OBJECTIVE:
To investigate the surgical technique and effectiveness of tension band-assisted plate fixation combined with external fixator for volar marginal fractures of the distal radius.
METHODS:
A retrospective analysis was performed on the clinical data of 12 patients with volar marginal fractures of the distal radius treated by Kirschner wire tension band-assisted anatomical plate fixation combined with external fixator between October 2018 and July 2023. The cohort included 9 males and 3 females, aged from 20 to 52 years (mean, 35.5 years). The injury causes included traffic accidents in 6 cases, falls from height in 3 cases, and fall in 3 cases. According to AO/Orthopaedic Trauma Association (AO/OTA), there were 1 case of type B2, 4 cases of type B3, 2 cases of type C1, 3 cases of type C2, and 2 cases of type C3. According to Fernandez classification, there were 2 cases of type Ⅲ, 5 cases of type Ⅳ, and 5 cases of type Ⅴ. Associated injuries included radiocarpal joint dislocation or subluxation in 7 cases and median nerve injury in 2 cases. The time from injury to operation was 2-7 days (mean, 3.2 days). Postoperatively, functional outcomes were evaluated using the modified Mayo wrist score and the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire. Grip strength was measured as the ratio to the unaffected side, and wrist range of motion (ROM) including dorsiflexion, palmar flexion, ulnar deviation, and radial deviation was assessed.
RESULTS:
All procedures were successfully completed, with an operation time of 55-110 minutes (mean, 65 minutes). All patients were followed up 6-36 months (mean, 13.7 months). Surgical incisions healed by first intention, without complications such as vascular-nerve injury or infection. Bony union and articular congruency were attained in all patients, with a healing time of 3-5 months (mean, 3.8 months). During follow-up, 1 case of Kirschner wire migration occurred with no instances of infections, radiocarpal dislocations, internal fixation failures, or extensor pollicis longus tendon ruptures. At last follow-up, the modified Mayo wrist score ranged from 65 to 92 (mean, 80.8), the DASH score ranged from 7 to 15 (mean, 11.6), the grip strength was 65%-90% (mean, 78.2%) of the unaffected side; and wrist ROM was palmar flexion 60°-85° (mean, 77.4°), dorsiflexion 55°-80° (mean, 74.8°), radial deviation 10°-25° (mean, 18.8°), and ulnar deviation 15°-30° (mean, 24.5°).
CONCLUSION
Kirschner wire tension band-assisted anatomical plate fixation combined with external fixator for volar marginal fractures of the distal radius is a simple method with reliable fixation, which can achieve satisfactory effectiveness.
Humans
;
Male
;
Adult
;
Female
;
Radius Fractures/diagnostic imaging*
;
Retrospective Studies
;
Middle Aged
;
Bone Plates
;
Bone Wires
;
External Fixators
;
Young Adult
;
Fracture Fixation, Internal/instrumentation*
;
Treatment Outcome
;
Range of Motion, Articular
;
Hand Strength
;
Wrist Injuries/surgery*
3.Three-dimentional printed personalized guide plate-assisted wrist arthroscopic repair of Palmer type ⅠB triangular fibrocartilage complex injury.
Jin LI ; Zhaoming ZHANG ; Lilian ZHAO ; Lilei HE ; Changbing WANG ; Yanjin LI ; Ting XU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1409-1413
OBJECTIVE:
To investigate the effectiveness of three-dimentional (3D) printed personalized guide plate-assisted wrist arthroscopic repair for Palmer type ⅠB triangular fibrocartilage complex (TFCC) injury.
METHODS:
A retrospective analysis was conducted on the clinical data of 20 patients with Palmer type ⅠB TFCC injuries admitted between January 2023 and March 2024 who met the selection criteria. Among them, 13 were male and 7 were female; ages ranged from 23 to 35 years, with a mean age of 30.3 years. All patients had a history of trauma, 12 cases involved falls and 8 cases involved sprains. All patients demonstrated a positive "piano key sign". MRI revealed deep ulnar-side tears of the TFCC. Conservative treatment for 6 weeks yielded poor or no clinical improvement. The interval from injury to surgery ranged from 2 to 9 months, with a mean of 5.0 months. Patients underwent wrist arthroscopic repair assisted by 3D printed personalized guide plate. Functional recovery was assessed preoperatively and postoperatively using the visual analogue scale (VAS) score for pain, modified Mayo wrist score, and range of motion (ROM) measurements for wrist flexion-extension, ulnar-radial deviation, and pronation-supination. At last follow-up, MRI was performed to evaluate the healing of TFCC.
RESULTS:
All 20 patients underwent successful surgery without complications such as vascular or nerve injury, fracture, incisional infection, or joint stiffness. All patients were followed up 9-18 months (mean, 12.4 months). At last follow-up, patients demonstrated significant improvements in VAS scores, modified Mayo wrist scores, wrist flexion-extension ROM, ulnar-radial deviation ROM, and pronation-supination ROM compared to preoperative levels ( P<0.05). MRI at last follow-up showed preserved TFCC continuity, excellent healing, and secure fixation.
CONCLUSION
3D-printed personalized guide plate significantly improve outcomes in wrist arthroscopic TFCC repair for Palmer type ⅠB injuries. They enable high-quality suturing, facilitate anatomical reconstruction, and markedly enhance wrist function.
Humans
;
Arthroscopy/methods*
;
Male
;
Adult
;
Triangular Fibrocartilage/diagnostic imaging*
;
Female
;
Retrospective Studies
;
Printing, Three-Dimensional
;
Wrist Injuries/diagnostic imaging*
;
Young Adult
;
Bone Plates
;
Treatment Outcome
;
Wrist Joint/surgery*
;
Magnetic Resonance Imaging
;
Range of Motion, Articular
4.Treatment of acute non-displaced scaphoid fracture of wrist with syringe needle-guided percutaneous cannulated headless hollow compression screw internal fixation.
China Journal of Orthopaedics and Traumatology 2023;36(2):161-164
OBJECTIVE:
To investigate the clinical efficacy of needle-guided percutaneous cannulated compression screw fixation in the treatment of acute non-displaced scaphoid fracture of wrist.
METHODS:
The clinic data of twenty-eight patients with acute non-displaced scaphoid fracture from January 2014 to January 2019 were analyzed retrospectively. According to the intraoperative method of placement of cannulated screw, they were divided into Guide group(16 patients)and Conventional group(12 patients). There were 13 males and 3 females in Guide group, aged from 20 to 60 years old with an average of(31.42±9.71)years old;5 patients were classified as type A2, 3 patients were classified as type B1 and 8 patients were classified as type B2 according to Herbert classification;they were treated with percutaneous cannulated compression screw fixation under the guidance of needle. There were 11 males and 1 female in Conventional group, aged from 23 to 61 years old with an average of(30.51±7.52)years old;5 patients were classified as type A2, 2 patients were classified as type B1 and 5 patients were classified as type B2 according to Herbert classification;they were treated with conventional percutaneous cannulated compression screw fixation. The operation time, screw angle relative to the longitudinal axis of the scaphoid and wrist function score were assessed and compared between the two groups.
RESULTS:
A total of 28 patients were followed up from 20 to 45 months with an average of (33.00±8.72) months. None of patients had intraoperative complication and incision infection. These patients returned to work gradually 2 weeks after operation, and all fractures healed within 12 weeks. The operation time in the Guide group was significantly less than that in the Conventinal group(P<0.05). Screw angle relative to the longitudinal axis of the scaphoid in the Guide group was significantly smaller than that in the Conventional group(P<0.05). There was no significant difference in Mayo wrist function scores at the last follow-up between the two groups(P>0.05). During the follow-up period, none of the 28 patients showed internal fixation displacement, arthritis, scaphoid necrosis and other complications.
CONCLUSION
In the treatment of acute non-displaced scaphoid fractures, the operation time of needle-guided percutaneous cannulated headless compression screw fixation is significantly shorter than that of conventional percutaneous screw fixation, and the screw axis is easier to be parallel to the longitudinal axis of the scaphoid.
Male
;
Humans
;
Female
;
Young Adult
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Scaphoid Bone/surgery*
;
Wrist
;
Retrospective Studies
;
Syringes
;
Wrist Injuries/surgery*
;
Fracture Fixation, Internal/methods*
;
Bone Screws
;
Treatment Outcome
5.Arthroscopic treatment of scaphoid fracture nonunion with bone graft and Kirschner wire combined with screw fixation.
Yong LI ; Yongbin FU ; Mingming MA ; Siwei MEI
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(11):1386-1389
OBJECTIVE:
To explore the effectiveness of arthroscopic treatment of scaphoid fracture nonunion with bone graft and Kirschner wire combined with screw fixation.
METHODS:
The clinical data of 14 patients with scaphoid fracture nonunion who met the selection criteria between February 2021 and September 2022 were retrospectively analyzed. There were 13 males and 1 female with an average age of 32 years ranging from 17 to 54 years. The time from injury to operation ranged from 6 to 15 months, with an average of 9.6 months. According to the Slade-Geissler classification of scaphoid fracture nonunion, there were 3 cases of grade Ⅲ, 8 cases of grade Ⅳ, and 3 cases of grade Ⅴ. The preoperative visual analogue scale (VAS) score was 5.9±1.0, and the modified Mayo wrist score was 53.2±9.1. There were 2 cases of scaphoid nonunion advanced collapse, both of which were stage Ⅰ. All patients were treated with arthroscopic bone graft and Kirschner wire combined with screw fixation, and the fracture healing was observed by X-ray film monthly after operation, and the effectiveness was evaluated by VAS score and modified Mayo wrist score before and after operation.
RESULTS:
All patients were followed up 6-14 months, with an average of 8.4 months. All fractures healed in 4-8 months, with an average of 6.3 months. The postoperative pain symptoms and wrist function of the patients significantly improved when compared with those before operation, and the VAS score at last follow-up was 2.4±1.3, and the modified Mayo wrist score was 87.1±6.7, which were significantly different from those before operation ( t=12.851, P<0.001; t=-14.410, P<0.001). According to the modified Mayo wrist evaluation, 9 cases were excellent, 3 cases were good, and 2 cases were fair.
CONCLUSION
Arthroscopic bone graft and Kirschner wire combined with screw fixation is an effective surgical method for the treatment of scaphoid fracture nonunion.
Male
;
Humans
;
Female
;
Adult
;
Fractures, Bone/surgery*
;
Bone Wires
;
Scaphoid Bone/injuries*
;
Retrospective Studies
;
Fracture Fixation, Internal/methods*
;
Fractures, Ununited/surgery*
;
Wrist Injuries/surgery*
;
Bone Screws
;
Hand Injuries
;
Treatment Outcome
6.Free Flow-through Anterolateral Thigh Flaps for Wrist High-tension Electrical Burns: A Retrospective Case Series.
Cheng WANG ; Yu Ming SHEN ; Feng Jun QIN ; Xiao Hua HU
Biomedical and Environmental Sciences 2020;33(7):510-517
Objective:
The objective of this report was to demonstrate the clinical application of free flow-through anterolateral thigh flaps for the treatment of high-tension electrical wrist burns.
Methods:
We collected the data of 8 patients with high-tension electrical wrist burns admitted to Beijing Jishuitan Hospital from January 2014 to December 2018. The clinical and pathological data were extracted from electronic hospital medical records. We obtained follow-up information through clinic visits.
Results:
The injury sites for all 8 patients were the wrists, specifically 5 right and 3 left wrists, all of which were on the flexor side. Five patients had ulnar artery embolism necrosis and patency, with injury to the radial artery. Two patients had ulnar and radial arterial embolization and necrosis. The last patient had ulnar arterial embolization and necrosis with a normal radial artery. After debridement, the wound area ranged from 12 cm × 9 cm to 25 cm × 16 cm. The diagnoses for the eight patients were type II to type III high-tension electrical wrist burns. Free flow-through anterolateral thigh flaps (combined with great saphenous vein transplantation if necessary) were used to repair the wounds. The prognosis for all patients was good after six months to one year of follow-up.
Conclusion
Treating wrist types II and III high-tension electrical burns is still challenging in clinical practice. The use of free flow-through anterolateral thigh flaps (combined with great saphenous vein transplantation if necessary) to repair the wound and to restore the blood supply for the hand at the same time is a good choice for treating severe wrist electrical burns.
Adult
;
Beijing
;
Burns, Electric
;
surgery
;
Humans
;
Male
;
Retrospective Studies
;
Surgical Flaps
;
statistics & numerical data
;
Thigh
;
Wound Healing
;
Wrist Injuries
;
surgery
;
Young Adult
7.Comparison of Ultrasound-Guided Axillary Brachial Plexus Block Techniques: Perineural Injection versus Single or Double Perivascular Infiltration.
Sooyoung CHO ; Youn Jin KIM ; Hee Jung BAIK ; Jong Hak KIM ; Jae Hee WOO
Yonsei Medical Journal 2015;56(3):838-844
PURPOSE: We compared three methods of ultrasound-guided axillary brachial plexus block, which were single, and double perivascular (PV) infiltration techniques, and a perineural (PN) injection technique. MATERIALS AND METHODS: 78 patients of American Society of Anesthesiologists physical status I-II undergoing surgery of the forearm, wrist, or hand were randomly allocated to three groups. 2% lidocaine with epinephrine 5 microg/mL was used. The PN group (n=26) received injections at the median, ulnar, and radial nerve with 8 mL for each nerve. The PV1 group (n=26) received a single injection of 24 mL at 12-o'clock position of the axillary artery. The PV2 group (n=26) received two injections of 12 mL each at 12-o'clock and 6-o'clock position. For all groups, musculocutaneous nerve was blocked separately. RESULTS: The PN group (391.2+/-171.6 sec) had the longest anesthetic procedure duration than PV1 (192.8+/-59.0 sec) and PV2 (211.4+/-58.6 sec). There were no differences in onset time. The average induction time was longer in PN group (673.4+/-149.6 sec) than PV1 (557.6+/-194.9 sec) and PV2 (561.5+/-129.8 sec). There were no differences in the success rate (89.7% vs. 86.2% vs. 89.7%). CONCLUSION: The PV injection technique consisting of a single injection in 12-o'clock position above the axillary artery in addition to a musculocutaneous nerve block is equally effective and less time consuming than the PN technique. Therefore, the PV technique is an alternative method that may be used in busy clinics or for difficult cases.
Adult
;
Anesthetics, Local/*administration & dosage/adverse effects
;
Brachial Plexus/*drug effects/*ultrasonography
;
Brachial Plexus Block/adverse effects/*methods
;
Female
;
Forearm/surgery
;
Hand/surgery
;
Humans
;
Injections
;
Male
;
Middle Aged
;
Peripheral Nerves/ultrasonography
;
Prospective Studies
;
Single-Blind Method
;
Treatment Outcome
;
*Ultrasonography, Interventional
;
Upper Extremity/innervation/*surgery
;
Vascular System Injuries/etiology
;
Wrist/surgery
8.Case-control study on T-shaped locking internal fixation and external fixation for the treatment of dorsal Barton's fracture.
Huan-qing CHEN ; Xi-le WEN ; Yang-ming LI ; Cong-you WEN
China Journal of Orthopaedics and Traumatology 2015;28(6):517-520
OBJECTIVETo compare clinical effect of T-shaped locking internal fixation and external fixation in treating dorsal Barton's fracture,and investigate selective strategy of internal fixation.
METHODSFrom January 2008 to January 2013, 100 patients with dorsal Barton's fracture were randomly divided into two groups. In treatment group, there were 30 males and 20 females with an average age of (33.8±3.6) years old;30 cases were type B, 20 cases were type C;and treated with T-shaped locking internal fixation. In control group, there were 32 male and 18 females with an average age of (32.9±3.4) years old; 29 cases were type B, 21 cases were type C; and treated with external fixation. Volar tilt, ulnar deviation and radial height at 3 months after operation were detected and compared between two groups. Mechara functional evaluation were used to evaluate postoperative clinical effects. Clinical cure time, postoperative complications,joint mobility and function score were recorded and compared between two groups.
RESULTSIn treatment group,volar tilt was (11.9±2.7)°, ulnar deviation was (20.8+ 2.9)°,and radial height was (10.9±1.8) mm; while volar tilt was (9.1±1.6)°, ulnar deviation was (17.1±2.9)°, and radial height was (8.1±1.5) mm in control group. Treatment group was better than control group in volar tilt, ulnar deviation and radial height. Clinical cure time in treatment group was(12.0±2.3) weeks, shorter than control group (18.0±4.1) weeks. The incidence of complications in treatment group was lower than control group. According to Mehara functional evaluation,20 cases got excellent results, 25 good, 3 moderate and 2 poor in treatment group; 16 cases got excellent results, 14 good, 10 moderate and 10 poor in control group. Treatment group was better than control group in clinical effects.
CONCLUSIONT-shaped locking internal fixation with postoperative functional exercise for the treatment of dorsal Barton's fracture fits for biomechanics demands,and has advantages of stable fixation,rapid recovery, less complications and good functional recovery, it has better clinical effects.
Adult ; Bone Plates ; Case-Control Studies ; Female ; Fracture Fixation ; instrumentation ; Fracture Fixation, Internal ; instrumentation ; Humans ; Male ; Radius Fractures ; surgery ; Wrist Injuries ; surgery
9.Application of bone flap pedicled on retrograde branch of radial artery for treatment of old scaphoid bone fractures of type AO-B.
China Journal of Orthopaedics and Traumatology 2015;28(5):426-428
OBJECTIVETo investigate application of the bone flap pedicled on the retrograde branch of radial artery for treatment of old scaphoid bone fractures of type AO-B.
METHODSFrom October 2007 to October 2011,41 patients with old scaphoid bone fractures of type AO-B were treated by transplantation of the bone flap pedicled on the retrograde branch of radial artery including 26 males and 15 females with an average of (27.3±4.5) years old ranging from 16 to 43 years old. The courses before operation ranged from 6 to 22 months with an average of 11 months. All fractures belonged to the type B of AO classification, that is old wrist fracture of scaphoid bone. All patients' wrist function (pain, function, motion, grip strength) were evaluated by Cooney's modifiedwrist scoring system before and 6 months after operation,and the conditions of bone healing were observed during the follow-up time.
RESULTSAmong them, 36 patients were followed up from 4 to 15 months with an average of 8.3 months. The wounds were healed well without other complications as infection appearing. X-rays or CT confirmed that all fractures were healed completely. The Cooney wrist score was improved from preoperative 53.61±13.97 to postoperative 81.81±8.71 (P<0.01).
CONCLUSIONThe operation of transplantation of the bone flap pedicled on the retrograde branch of radial artery is an effective method to treat old scaphoid bone fractures,which is scientific and has curative effects, and valuable for clinical application.
Adolescent ; Adult ; Female ; Fractures, Bone ; surgery ; Humans ; Male ; Radial Artery ; injuries ; surgery ; Scaphoid Bone ; blood supply ; injuries ; surgery ; Surgical Flaps ; Wrist Injuries ; surgery ; Young Adult
10.Clinical Characteristic and Psychiatric Features of Self-Inflicted Wrist Laceration: A Single Institute Retrospective Study.
Hee Eun CHO ; Si Gyun ROH ; Nae Ho LEE ; Kyung Moo YANG
Journal of the Korean Society for Surgery of the Hand 2015;20(1):1-7
PURPOSE: Self-inflicted wrist laceration is a common injury in the department of hand surgery. The aim of this study was to investigate the clinical characteristics and psychiatric features of self-inflicted wrist laceration using categorization according to wound severity. METHODS: We reviewed 71 patients from 2002 through 2012. All of the patients were grouped into four groups. Data regarding the following characteristics were collected: age, gender, size, structure involved, instruments used, history of previous self-inflicted injury, comorbidities in psychiatric and presentation of follow-up outpatient appointment to the department of plastic surgery and psychiatry. RESULTS: In these patients, approximately 64% of patients were female. About 80% of patients cut their wrist using a knife. And in grade 3-4 injury, percentage of glass injury was relatively high (22%), compared with other grades (3%). Unlike previous studies, patients in grade 3-4 tended to cut their wrist repeatedly. Focusing on psychiatric problems, approximately one quarter of patients had a previous history of self-infliction. In all patient groups, mood disorder was the most common disorder in patients who had a previous psychiatric disorder. But after operation, more than two thirds of patients had not visited department of psychiatry again. CONCLUSION: We identified some other differences among their characteristics. All patients in group also should be evaluated and surgically treated properly. A multidisciplinary approach is required for patients with wrist laceration due to self-injury in comparison to those with laceration due to other causes. Because many of them have previous self-injury experiences and psychiatric disease.
Comorbidity
;
Female
;
Follow-Up Studies
;
Glass
;
Hand
;
Humans
;
Lacerations*
;
Mood Disorders
;
Outpatients
;
Retrospective Studies*
;
Self Mutilation
;
Suicide
;
Surgery, Plastic
;
Wounds and Injuries
;
Wrist*

Result Analysis
Print
Save