1.Poster Fusion Cage combined with xenogeneic bone graft augmentation for bone defect management in distal radius fractures.
Yi GAO ; Xiaomeng REN ; Chuyang ZENG ; Longbo DU ; Meng LI ; Rui MA ; Wei ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):655-661
OBJECTIVE:
To evaluate the effectiveness of Poster Fusion Cage combined with xenogeneic bone graft augmentation for bone defect management in distal radius fractures.
METHODS:
A retrospective analysis was conducted on 20 patients with bone defects complicating distal radius fractures who met the selection criteria and were treated between June 2022 and June 2024. The cohort comprised 2 males and 18 females, aged 54-87 years (mean, 63.3 years). Etiologies included falls in 17 cases, traffic accidents in 2 cases, and crush injury in 1 case. According to AO classification, there were 5 cases of type A, 8 cases of type B, and 7 cases of type C. The interval from injury to operation ranged from 2 to 10 days (mean, 5.8 days). All patients underwent volar plate fixation augmented with Poster Fusion Cage and demineralized xenogeneic bone matrix grafting. The operation time, intraoperative blood loss, fracture healing time, and postoperative complications were recorded. Radiographic parameters, including radial height, volar tilt, and ulnar deviation, were measured on standardized X-ray films obtained immediately postoperatively and at last follow-up, and whether secondary reduction loss occurred was judged. At last follow-up, wrist range of motion (extension, flexion, radial deviation, ulnar deviation, pronation, and supination) and grip strength (expressed as a percentage of the contralateral side) were measured. Wrist function was assessed using the Disabilities of the Arm, Shoulder, and Hand (DASH) score and Patient-Rated Wrist Evaluation (PRWE) score.
RESULTS:
The operation time was 70-200 minutes (mean, 116.4 minutes), and the intraoperative blood loss was 10-80 mL (mean, 36.5 mL). All surgical incisions healed by first intention, with no neurovascular complications documented. All patients were followed up 9-12 months (mean, 11.6 months). All fractures healed normally, with a healing time of 8-14 weeks (mean, 9.95 weeks). No significant difference was observed in radial height, volar tilt, or ulnar deviation between immediate postoperatively and last follow-up ( P>0.05). All fractures achieved satisfactory reduction, with no secondary loss of reduction or implant failure occurring during follow-up. At last follow-up, the range of motion of the affected wrist joint was 60°-65° (mean, 62.5°) in extension, 67°-75° (mean, 71.1°) in flexion, 18°-23° (mean, 20.4°) in radial deviation, 28°-33° (mean, 30.1°) in ulnar deviation, 69°-80° (mean, 74.7°) in pronation, and 69°-82° (mean, 75.6°) in supination. Grip strength recovered to 75%-85% (mean, 80%) of the contralateral side. Functional scores showed a DASH score of 5-15 (mean, 9.4) and PRWE score of 8.0-12.5 (mean, 10.2).
CONCLUSION
The combination of Poster Fusion Cage and xenogeneic bone graft augmentation provides a safe and effective treatment for bone defects in distal radius fractures.
Retrospective Studies
;
Humans
;
Male
;
Female
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Treatment Outcome
;
Wrist Fractures/surgery*
;
Heterografts
;
Transplantation, Heterologous/methods*
;
Bone Transplantation/methods*
;
Operative Time
;
Blood Loss, Surgical
;
Radius/surgery*
;
Fracture Healing
;
Time Factors
;
Postoperative Complications/etiology*
;
Range of Motion, Articular
;
Follow-Up Studies
;
Internal Fixators
;
Fracture Fixation, Internal/methods*
;
Combined Modality Therapy
2.Effectiveness analysis of tension band-assisted fixation for volar marginal fractures of distal radius.
Abulimiti MIREADELI ; Wanming QU ; Tianbo ZHU ; Daoxin ZHANG ; Xiaokang ZHU ; Xinzhi LI ; Wenyao CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):662-667
OBJECTIVE:
To investigate the surgical technique and effectiveness of tension band-assisted plate fixation combined with external fixator for volar marginal fractures of the distal radius.
METHODS:
A retrospective analysis was performed on the clinical data of 12 patients with volar marginal fractures of the distal radius treated by Kirschner wire tension band-assisted anatomical plate fixation combined with external fixator between October 2018 and July 2023. The cohort included 9 males and 3 females, aged from 20 to 52 years (mean, 35.5 years). The injury causes included traffic accidents in 6 cases, falls from height in 3 cases, and fall in 3 cases. According to AO/Orthopaedic Trauma Association (AO/OTA), there were 1 case of type B2, 4 cases of type B3, 2 cases of type C1, 3 cases of type C2, and 2 cases of type C3. According to Fernandez classification, there were 2 cases of type Ⅲ, 5 cases of type Ⅳ, and 5 cases of type Ⅴ. Associated injuries included radiocarpal joint dislocation or subluxation in 7 cases and median nerve injury in 2 cases. The time from injury to operation was 2-7 days (mean, 3.2 days). Postoperatively, functional outcomes were evaluated using the modified Mayo wrist score and the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire. Grip strength was measured as the ratio to the unaffected side, and wrist range of motion (ROM) including dorsiflexion, palmar flexion, ulnar deviation, and radial deviation was assessed.
RESULTS:
All procedures were successfully completed, with an operation time of 55-110 minutes (mean, 65 minutes). All patients were followed up 6-36 months (mean, 13.7 months). Surgical incisions healed by first intention, without complications such as vascular-nerve injury or infection. Bony union and articular congruency were attained in all patients, with a healing time of 3-5 months (mean, 3.8 months). During follow-up, 1 case of Kirschner wire migration occurred with no instances of infections, radiocarpal dislocations, internal fixation failures, or extensor pollicis longus tendon ruptures. At last follow-up, the modified Mayo wrist score ranged from 65 to 92 (mean, 80.8), the DASH score ranged from 7 to 15 (mean, 11.6), the grip strength was 65%-90% (mean, 78.2%) of the unaffected side; and wrist ROM was palmar flexion 60°-85° (mean, 77.4°), dorsiflexion 55°-80° (mean, 74.8°), radial deviation 10°-25° (mean, 18.8°), and ulnar deviation 15°-30° (mean, 24.5°).
CONCLUSION
Kirschner wire tension band-assisted anatomical plate fixation combined with external fixator for volar marginal fractures of the distal radius is a simple method with reliable fixation, which can achieve satisfactory effectiveness.
Humans
;
Male
;
Adult
;
Female
;
Radius Fractures/diagnostic imaging*
;
Retrospective Studies
;
Middle Aged
;
Bone Plates
;
Bone Wires
;
External Fixators
;
Young Adult
;
Fracture Fixation, Internal/instrumentation*
;
Treatment Outcome
;
Range of Motion, Articular
;
Hand Strength
;
Wrist Injuries/surgery*
3.Short-term clinical efficacy of unilateral external fixator combined with percutaneous Kirschner wire fixation in the treatment of type C1 distal radius fractures in elderly patients.
Run-Bin SHEN ; Guo-Liang LI ; Xiao-Ping LIU ; Kang CHEN ; Guang-Pu HAN ; Jian-Yong ZHAO
China Journal of Orthopaedics and Traumatology 2025;38(1):25-30
OBJECTIVE:
To investigate the short-term clinical effect of closed reduction single arm external fixator combined with percutaneous needle fixation in the treatment of C1 distal radius fracture in elderly patients.
METHODS:
Between December 2022 and December 2023, a total of 60 elderly patients diagnosed with type C1 distal radius fractures were treated, comprising 9 males and 51 females. The age ranged from 65 to 84 years old, with an average of (72.69±8.14) years old. Among them, there were 18 cases on the left side and 42 cases on the right side. There were 55 cases of falling injury and 5 cases of traffic accident injury. According to the different surgical methods, the patients were divided into observation group and control group, with 30 cases in each group. The control group underwent manual reduction and unilateral external fixator fixation, consisting of 4 males and 26 females. The mean age was (72.54±8.67) years old. The body mass index (BMI) was (20.61±2.17) kg·m-2. There were 10 cases on the left side and 20 cases on the right side. Among them, there were 27 cases of falling injury and 3 cases of traffic accident injury. The observation group was treated with manual reduction and unilateral external fixator combined with percutaneous Kirschner wire fixation, including 5 males and 25 females. The mean age was (72.76±7.23) years old. BMI (20.82±2.03) kg·m-2. The left side was involved in 8 cases and the right side in 22 cases. There were 28 cases of falling injury and 2 cases of traffic accident injury. The changes in radial height, ulnar declination, palmar inclination angle parameters and patient-rated wrist evaluation (PRWE) were assessed on X-ray films before surgery, 2 days after surgery, and 12 weeks after surgery between the two groups.
RESULTS:
All surgical procedures were successfully completed in both groups without any significant complications. All patients were followed up for a duration from 12 to 20 weeks with an average of(14.50±2.78) weeks. The two groups exhibited significant differences in radial height, palmar inclination angle, and ulnar deviation angle at 2 days and 12 weeks post-operation (P<0.05). However, there was no statistically significant difference observed in radial height, palmar inclination, and ulnar deviation between the two groups at 2 days after the operation (P>0.05). There were significant differences in radial height, palmar inclination angle, and ulnar deviation between the two groups at 12 weeks after operation (P<0.05). At 2 days and 12 weeks after the operation, there were significant differences in PRWE scores of the two groups compared with preoperative scores(P<0.05). At 2 days after the operation, there was no significant difference in PRWE score between the two groups (P>0.05). The PRWE score showed a significant difference between the two groups at 12 weeks post-operation(P<0.05).
CONCLUSION
The combination of closed reduction and unilateral external fixator, along with percutaneous pin fixation provides move stable fixation for type C1 distal radius fractures. Gradual removal of external fixator further facilitatse the recovery of wrist joint function.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
External Fixators
;
Aged
;
Aged, 80 and over
;
Bone Wires
;
Fracture Fixation/instrumentation*
;
Wrist Fractures
4.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures
5.Meta-analysis of the efficacy of plate fixation and external fixator fixation in the treatment of AO-C type distal radius fractures.
Guang-Yao LI ; Yong-Zhong CHENG ; Huan LIU ; Jun-Jie JIANG ; Yong-Yao LI ; Yang CHEN ; Yu-Xiang YAO
China Journal of Orthopaedics and Traumatology 2025;38(1):66-80
OBJECTIVE:
Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.
METHODS:
PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database. The database will be established until June 30, 2023. The included studies were extracted according to the Cochrane Handbook (Version 6.3, 2022) for information extraction and literature quality evaluation. RevMan 5.4 was used to evaluate the risk of Publication bias, test heterogeneity and Perform Meta-analysis. The outcome indicators were:imaging anatomy indicators (volar inclination angle, ulnar deviation angle, radial height), wrist joint mobility (flexion, extension, rotation, ulnar deviation), complication rate, and comparison of surgical treatments (operative blood loss, operation time, hospitalization time, fracture healing time) and wrist joint function scores and related scales.
RESULTS:
(1) A total of 28 studies were included, with a total of 2 192 patients, including 1 096 cases in the plate internal fixation group and 1 096 cases in the external fixation group.(2) Meta analysis results showed:the surgical treatment situation of the external fixation group:surgical blood loss MD=-37.93, 95%CI(-48.54, -27.31), P<0.000 01;operation time MD=-31.58, 95%CI(-48.96, -14.20), P<0.000 4;hospitalization time MD=-4.58, 95%CI(-5.44, -3.71), P<0.000 01;the fracture healing time MD=-0.88, 95%CI(-1.35, -0.41), P<0.000 2, which were significantly better than that of the plate internal fixation group(P<0.05).(3) The two groups:palmar inclination angle MD=-0.17, 95%CI(-0.95, 0.61), P=0.68;ulnar declination MD=0.22, 95%CI(-0.73, 1.17), P=0.65, radial height MD=-0.24, 95%CI(-1.15, 0.67), P=0.60;flexion and extension MD=-5.63, 95%CI(-11.85, 0.58), P=0.08;rotation MD=-5.80, 95%CI(-12.77, 1.17), P=0.10, radioulnar deviation MD=-2.86, 95%CI(-10.87, 5.15), P=0.48;complication rate RR=0.96, 95%CI(0.63, 1.46), P=0.83;Gartland-Werley clinical wrist score MD=0.13, 95%CI(-0.80, 1.06), P=0.78;excellent and good rate of Gartland-Werley wrist clinical score RR=0.93, 95%CI(0.87, 1.01), P=0.08;excellent and good rate of Cooney wrist score RR=0.99, 95%CI(0.62, 1.59), P=0.98;wrist DASH score MD=-4.67, 95%CI(-14.96, 5.62), P=0.37;the differences were not significant (P>0.05).
CONCLUSION
Compared with internal fixation with plate, external fixation can significantly reduce the amount of surgical bleeding, shorten the operation time, hospitalization time and fracture healing time, and its imaging anatomical indicators, wrist mobility, and complications can be significantly reduced in treating AO-C distal radius fractures. Rates and wrist function scores were equivalent.
Humans
;
External Fixators
;
Bone Plates
;
Radius Fractures/surgery*
;
Fracture Fixation/methods*
;
Fracture Fixation, Internal
;
Wrist Fractures
6.Clinical application of special fluoroscopy method in the treatment of distal radius fractures with volar locking plate.
Rong ZHANG ; He-Ming NIU ; Tao GUO ; Ping-Feng XIE ; Jia-Ming WU ; Jia-Bing XIE ; Lin WANG
China Journal of Orthopaedics and Traumatology 2023;36(2):128-132
OBJECTIVE:
The relationship between the distal screws and the wrist articular surface was assessed by the additional lateral oblique fluoroscopic view during the operation, and the dorsal tangential view of the wrist was used to observe whether the distal screw penetrated the dorsal cortex, so as to evaluate the clinical efficacy of the volar locking plate in the treatment of distal radius fractures.
METHODS:
From January 2020 to June 2021, 45 cases of fresh distal radius fractures were treated using the volar Henry's approach, including 20 males and 25 females, aged from 32 to 75 years old with an average of (52.4±8.1) years old. During the operation, they were divided into 2 groups according to the different intraoperative fluoroscopic views:the control group of 20 cases, treated with standard anteroposterior and lateral fluoroscopic view;25 cases in the observation group, additional lateral oblique fluoroscopic view and dorsal tangential view of the wrist were taken. The wrist joint function score and postoperative complications were evaluated at 6 weeks, 3 and 6 months after operation between two groups.
RESULTS:
All 45 patients were followed up and the duration ranged from 6 to 14 months, with an average of (10.8±1.7) months, all patients achieved bone union and the incision healed well. The incidence of postoperative complications in the observation group was lower than that in the control group, and the difference was statistically significant (P<0.05). In terms of Gartland-Werley score of wrist joint function, the score of wrist function in the observation group was (4.58±1.31) at 6 weeks, (2.98±0.63) at 3 months and (1.95±0.65) at 6 months post-operatively, which were better than those in the control group (6.32±1.96) at 6 weeks, (3.63±0.76) at 3 months and (2.43±0.73) at 6 months. The difference was statistically significant (P<0.05). In the observation group, 7/25 cases(28%) were found to have screw penetration during the operation by additional lateral oblique and dorsal tangential radiograph fluoroscopic views of wrist.
CONCLUSION
The addition of lateral oblique and dorsal tangential during the operation could improve the accuracy of distal screw placement, reduce postoperative complications, and achieve early functional exercise.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Wrist Fractures
;
Radius Fractures/surgery*
;
Fracture Fixation, Internal/methods*
;
Fluoroscopy/methods*
;
Bone Plates
;
Postoperative Complications
7.Treatment of acute non-displaced scaphoid fracture of wrist with syringe needle-guided percutaneous cannulated headless hollow compression screw internal fixation.
China Journal of Orthopaedics and Traumatology 2023;36(2):161-164
OBJECTIVE:
To investigate the clinical efficacy of needle-guided percutaneous cannulated compression screw fixation in the treatment of acute non-displaced scaphoid fracture of wrist.
METHODS:
The clinic data of twenty-eight patients with acute non-displaced scaphoid fracture from January 2014 to January 2019 were analyzed retrospectively. According to the intraoperative method of placement of cannulated screw, they were divided into Guide group(16 patients)and Conventional group(12 patients). There were 13 males and 3 females in Guide group, aged from 20 to 60 years old with an average of(31.42±9.71)years old;5 patients were classified as type A2, 3 patients were classified as type B1 and 8 patients were classified as type B2 according to Herbert classification;they were treated with percutaneous cannulated compression screw fixation under the guidance of needle. There were 11 males and 1 female in Conventional group, aged from 23 to 61 years old with an average of(30.51±7.52)years old;5 patients were classified as type A2, 2 patients were classified as type B1 and 5 patients were classified as type B2 according to Herbert classification;they were treated with conventional percutaneous cannulated compression screw fixation. The operation time, screw angle relative to the longitudinal axis of the scaphoid and wrist function score were assessed and compared between the two groups.
RESULTS:
A total of 28 patients were followed up from 20 to 45 months with an average of (33.00±8.72) months. None of patients had intraoperative complication and incision infection. These patients returned to work gradually 2 weeks after operation, and all fractures healed within 12 weeks. The operation time in the Guide group was significantly less than that in the Conventinal group(P<0.05). Screw angle relative to the longitudinal axis of the scaphoid in the Guide group was significantly smaller than that in the Conventional group(P<0.05). There was no significant difference in Mayo wrist function scores at the last follow-up between the two groups(P>0.05). During the follow-up period, none of the 28 patients showed internal fixation displacement, arthritis, scaphoid necrosis and other complications.
CONCLUSION
In the treatment of acute non-displaced scaphoid fractures, the operation time of needle-guided percutaneous cannulated headless compression screw fixation is significantly shorter than that of conventional percutaneous screw fixation, and the screw axis is easier to be parallel to the longitudinal axis of the scaphoid.
Male
;
Humans
;
Female
;
Young Adult
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Scaphoid Bone/surgery*
;
Wrist
;
Retrospective Studies
;
Syringes
;
Wrist Injuries/surgery*
;
Fracture Fixation, Internal/methods*
;
Bone Screws
;
Treatment Outcome
8.Analysis of the effectiveness of sequential plate internal fixation in correction of Madelung deformity after ulnar osteotomy and shortening.
Wei WANG ; Xiaowen DENG ; Wenbo LI ; Miaomiao YANG ; Yaqiang ZHANG ; Peisheng SHI ; Weiwei SHEN ; Rui LIU ; Jie SHI ; Chuangbing LI ; Yun XUE ; Qiuming GAO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):810-814
OBJECTIVE:
To investigate the effectiveness of sequential plate internal fixation in the correction of Madelung deformity after ulnar osteotomy and shortening.
METHODS:
The clinical data of 13 patients with Madelung deformity admitted between September 2015 and July 2021 were retrospectively analyzed. There were 5 males and 8 females with an average age of 18.3 years ranging from 17 to 23 years. The disease duration ranged from 12 to 24 months, with an average of 17 months. Three cases had a clear history of trauma. All patients had external radial deviation deformity and limited movement of the ulnar deviation, and the ulnar impact pain was significant during ulnar deviation movement; 9 patients had limited wrist joint supination movement, and the supination movement was normal. In the first stage, ulnar osteotomy and shortening combined with external fixator were used to correct wrist deformity in 13 patients. After operation, bone transfer was performed 6 times per day, with adjustments made every 4 hours, which was 1 mm per day. After the osteotomy was in place, the ulnar plate internal fixation was performed to reconstruct the ulnar stability in the second stage. The Cooney wrist joint score was used to assess the pain, function, range of motion, flexion and extension range of motion, and grip strength of the wrist joint before operation and before the removal of internal fixator. The subjective feeling and appearance satisfaction of patients were recorded.
RESULTS:
After the second-stage operation, all the 13 patients were followed up 10-22 months, with an average of 15 months. The deformity of wrist joint disappeared after operation, and the flexion, extension, and ulnar deviation were basically normal. There was no complication such as ulnar impingement sign, nonunion or infection. Wrist function, pain, and range of motion were significantly improved after operation, except for 1 patient who had no significant improvement in rotation and pain. The ulnar internal fixator was removed at 10-18 months after the second-stage operation. The scores of pain, function, range of motion, flexion and extension range of motion, and grip strength in the Cooney wrist score before removal of internal fixator significantly improved when compared with those before operation ( P<0.05). Subjective and appearance satisfaction of patients were excellent in 9 cases, good in 3 cases, and fair in 1 case.
CONCLUSION
Ulnar osteotomy and shortening with sequential plate internal fixation for correction of Madelung deformity, with mild postoperative pain, can effectively avoid bone nonunion, improve wrist joint function, and have significant effectiveness.
Male
;
Female
;
Humans
;
Adolescent
;
Retrospective Studies
;
Ulna/surgery*
;
Osteochondrodysplasias
;
Radius Fractures/surgery*
;
Wrist Joint/surgery*
;
Osteotomy
;
Range of Motion, Articular
;
Treatment Outcome
9.Clinical analysis of distal radius core decompression for chronic wrist pain.
Jixin WU ; Jiayu SUN ; Xin LIU ; Jie SONG ; Shaonan HU ; Liang CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):815-820
OBJECTIVE:
To investigate the effectiveness of distal radius core decompression in the treatment of chronic wrist pain caused by various etiologies.
METHODS:
A retrospective analysis was performed for the clinical data of 10 patients with chronic wrist pain treated with distal radial core decompression between January 2018 and December 2021. There were 6 males and 4 females with an average age of 37.4 years (range, 21-55 years). The disease duration ranged from 7 to 72 months, with an average of 26.5 months. Preoperative MRI examination showed that 10 cases had bone marrow edema at the distal radius on the affected side, and 8 cases had bone marrow edema in the carpal bones such as scaphoid and lunate bone. Among them, 3 patients had a history of wrist fracture, and 2 patients had Kienböck diseases (1 case each in stage ⅡB and stage ⅢA). Three cases were combined with triangular fibrocartilage complex (TFCC) type 1A injury. Two cases were combined with osteoarthritis, 1 of them was complicated with severe traumatic arthritis, the wrist arthroscopy showed that the TFCC was completely lost and could not be repaired, and the cartilage of the lunate bone and the ulnar head were severely worn.Visual analogue scale (VAS) score was used to evaluate the relief of wrist pain before operation, at 6 months after operation, and at last follow-up, and the range of motion of the affected wrist in dorsiflexion, palmar flexion, ulnar deviation, and radial deviation was measured. The degree of bone marrow edema was evaluated according to T1WI, T2WI, and STIR sequences of MRI.
RESULTS:
All the patients were followed up 12-22 months, with an average of 16.4 months. Except for 1 patient who experienced persistent wrist joint pain and limited mobility after operation, the remaining 9 patients showed significant improvement in pain symptoms and wrist joint mobility. The VAS score and range of motion of wrist dorsiflexion, palmar flexion, ulnar deviation, and radial deviation at 6 months after operation and at last follow-up were significantly improved when compared with those before operation, the VAS score and the range of motion of wrist ulnar deviation and radial deviation at last follow-up were further improved when compared with those at 6 months after operation, all showing significant differences ( P<0.05). There was no significant difference in wrist dorsiflexion and palmar flexion between at 6 months after operation and at last follow-up ( P>0.05). Bone marrow edema was improved in 6 patients on MRI at 6 months after operation, and was also improved in other patients at last follow-up.
CONCLUSION
For chronic wrist pain caused by a variety of causes, distal radius core decompression can directly reduce the pressure of the medullary cavity of the distal radius, improve the blood supply of the corresponding distal structure, significantly alleviate chronic wrist pain, and provide an option for clinical treatment.
Male
;
Female
;
Humans
;
Adult
;
Radius/surgery*
;
Wrist
;
Retrospective Studies
;
Radius Fractures/surgery*
;
Wrist Joint/surgery*
;
Scaphoid Bone/surgery*
;
Pain
;
Arthralgia/complications*
;
Arthroscopy
;
Decompression
;
Range of Motion, Articular
;
Treatment Outcome
10.Double-column Die-punch fractures of distal radius treated with butterfly plate fixation via Henry approach.
Hai-Bo XIA ; Jun LAN ; Li-Qing JIANG ; Hua-Fei YANG ; Xiao-Hui NIU
China Journal of Orthopaedics and Traumatology 2023;36(4):376-380
OBJECTIVE:
To explore clinical effect of open reduction and internal fixation with Henry's approach butterfly plate in treating double-column Die-punch fractures of distal radius.
METHODS:
From January 2018 to June 2021, 26 patients with double-column Die-column distal radius were treated with open reduction and internal fixation through Henry's surgical approach and using distal radius volar column plate(butterfly plate), including 14 males and 12 females, aged from 20 to 75 years old with an average age of (44.2±3.4) years old. Postopertaive complications were observed, Gartland-Werley score at 12 months after opertaion was used to evaluate wrist joint function.
RESULTS:
All 26 patients were followed up from 10 to 18 months with an average of(13.4±0.8) months. All fractures were obtained fracture union, the time ranged from 8.5 to 15.8 weeks with an average of (11.4±0.5) weeks. All incisions healed at stageⅠwithout infection, nerve injury and internal fixation failure occurred. Postoperative Gartland-Werley score at 12 months was (3.65±0.36), and 16 patients got excellent result, 8 good and 2 moderate.
CONCLUSION
Open reduction and internal fixation with butterfly plate for the treatment of double-column Die-punch fractures of the distal radius through volar Henry approach could obtain satisfactory clinical outcomes.
Adult
;
Aged
;
Animals
;
Female
;
Humans
;
Male
;
Middle Aged
;
Young Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
Radius/surgery*
;
Radius Fractures/surgery*
;
Range of Motion, Articular
;
Treatment Outcome
;
Wrist Joint

Result Analysis
Print
Save
E-mail