1.Wrist arthroscopic Wafer surgery combined with triangular fibrocartilage complex insertion point reconstruction in treatment of Palmer type ⅡC combined with type ⅠB ulnar impingement syndrome.
Yong LI ; Mingming MA ; Xiaojun RUAN ; Yongbin FU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):59-63
OBJECTIVE:
To investigate the effectivess of arthroscopic Wafer surgery combined with triangular fibrocartilage complex (TFCC) insertion point reconstruction in the treatment of Palmer type ⅡC combined with typeⅠB ulnar impingement syndrome.
METHODS:
The clinical data of 14 patients with Parlmer type ⅡC combined with type ⅠB ulnar impingement syndrome who met the selection criteria between July 2021 and April 2024 were retrospectively analyzed. There were 7 males and 7 females with an average age of 43 years ranging from 16 to 59 years. The causes of injury were fall in 8 cases and sprain in 6 cases. The time from injury to operation ranged from 1 to 6 months, with an average of 2.3 months. Distal radioulnar joint instability was found in all cases. Arthroscopic Wafer surgery combined with TFCC insertion point reconstruction was used. The effectiveness was evaluated by comparing the wrist flexion-dorsiflexion range of motion, wrist ulnar deviation-radial deflection range of motion, forearm pronation-supination range of motion, visual analogue scale (VAS) score, and modified Mayo wrist score before and after operation.
RESULTS:
All patients were followed up 6-12 months, with an average of 9.1 months. The positive variation of ulna was (3.2±0.7) mm before operation, and the negative variation of ulna was (2.2±0.6) mm after operation. There was a significant difference in ulna variation between pre- and post-operation ( t=23.851, P<0.001). The pain symptoms and forearm rotation function of the patients after operation significantly improved. At last follow-up, the wrist flexion-dorsiflexion range of motion, wrist ulnar deviation-radial deflection range of motion, forearm pronation-supination range of motion, VAS score, and modified Mayo wrist score significantly improved when compared with those before operation ( P<0.05).
CONCLUSION
Arthroscopic Wafer surgery combined with TFCC insertion point reconstruction can effectively relieve wrist pain, enhance the stability of the distal radioulnar joint, and restore the function of the wrist in patients with Palmer type ⅡC combined with type ⅠB ulnar impingement syndrome.
Humans
;
Male
;
Adult
;
Arthroscopy/methods*
;
Female
;
Triangular Fibrocartilage/surgery*
;
Middle Aged
;
Range of Motion, Articular
;
Retrospective Studies
;
Wrist Joint/physiopathology*
;
Adolescent
;
Young Adult
;
Ulna/surgery*
;
Treatment Outcome
;
Wrist Injuries/surgery*
;
Plastic Surgery Procedures/methods*
;
Joint Instability/surgery*
2.Clinical observation of free palmaris longus tendon graft reconstruction in treatment of gouty tophus erosion lesions in flexor tendon of wrist and hand.
Guozhong WANG ; Chao LU ; Zhigang QU ; Yuejuan ZHANG ; Benjun BI ; Fei GAO ; Zhao ZHANG ; Yuehai PAN ; Enxia ZHU ; Heng HUANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):278-283
OBJECTIVE:
To investigate the effectiveness of free palmaris longus tendon graft reconstruction in the treatment of gouty tophus erosion lesions in flexor tendon of wrist and hand.
METHODS:
A retrospective analysis was conducted on 8 patients with gouty tophus erosion lesions in flexor tendon of wrist and hand who underwent free palmaris longus tendon graft reconstruction between June 2017 and December 2023. All patients were male, aged 22-65 years, with an average of 45.9 years. The duration of gout history ranged from 2 to 18 years, with an average of 8.8 years. The duration from the discovery of gouty tophus to operation ranged from 12 to 26 months, with an average of 17.6 months. The gouty tophus eroded the flexor pollicis longus tendon in 4 cases, with Verdan flexor tendon zones being Ⅰ-Ⅱ in 1 case and Ⅳ-Ⅴ in 3 cases. The flexor digitorum profundus tendons were affected in 2 cases for the index finger, 1 for the middle finger, and 1 for the ring finger, all located in zone Ⅳ-Ⅴ. The long axis of the gouty tophus ranged from 2.3 to 4.5 cm, with an average of 3.4 cm. All 8 patients presented with limited finger flexion and extension. Among them, 4 cases were accompanied by median nerve compression symptoms, and 1 case had associated bone and joint destruction in the hand. The total active motion (TAM) of the affected finger was (81.3±30.2)° before operation according to the hand function evaluation criteria for tendon repair by the Chinese Society of Hand Surgery of the Chinese Medical Association, and the functional evaluation was poor. The harvested palmaris longus tendon intraoperatively was 7-9 cm in length.
RESULTS:
Surgical incisions in all 8 patients healed by first intention, with no infections, graft non-union, or significant adhesion complications. All patients were followed up 8-25 months, with an average of 14.8 months. Numbness symptoms resolved in all 4 patients who presented with median nerve compression symptoms. Patients did not experience wrist pain or other discomfort, and function was not compromised. At last follow-up, according to the hand function evaluation criteria for tendon repair by the Chinese Society of Hand Surgery of the Chinese Medical Association, the TAM of 8 patients was (197.5±55.8)°, which significantly improved when compared with that before operation ( t=11.638, P<0.001); the hand function of 1 patient with gouty tophus in zone Ⅰ-Ⅱ flexor pollicis longus tendon was good, and the other 7 patients were excellent.
CONCLUSION
Free palmaris longus tendon graft reconstruction demonstrates good effectiveness in treating gouty tophus erosion lesions in flexor tendon of wrist and hand.
Humans
;
Middle Aged
;
Male
;
Adult
;
Tendons/surgery*
;
Retrospective Studies
;
Aged
;
Gout/complications*
;
Wrist/surgery*
;
Plastic Surgery Procedures/methods*
;
Hand/surgery*
;
Treatment Outcome
;
Young Adult
3.Poster Fusion Cage combined with xenogeneic bone graft augmentation for bone defect management in distal radius fractures.
Yi GAO ; Xiaomeng REN ; Chuyang ZENG ; Longbo DU ; Meng LI ; Rui MA ; Wei ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):655-661
OBJECTIVE:
To evaluate the effectiveness of Poster Fusion Cage combined with xenogeneic bone graft augmentation for bone defect management in distal radius fractures.
METHODS:
A retrospective analysis was conducted on 20 patients with bone defects complicating distal radius fractures who met the selection criteria and were treated between June 2022 and June 2024. The cohort comprised 2 males and 18 females, aged 54-87 years (mean, 63.3 years). Etiologies included falls in 17 cases, traffic accidents in 2 cases, and crush injury in 1 case. According to AO classification, there were 5 cases of type A, 8 cases of type B, and 7 cases of type C. The interval from injury to operation ranged from 2 to 10 days (mean, 5.8 days). All patients underwent volar plate fixation augmented with Poster Fusion Cage and demineralized xenogeneic bone matrix grafting. The operation time, intraoperative blood loss, fracture healing time, and postoperative complications were recorded. Radiographic parameters, including radial height, volar tilt, and ulnar deviation, were measured on standardized X-ray films obtained immediately postoperatively and at last follow-up, and whether secondary reduction loss occurred was judged. At last follow-up, wrist range of motion (extension, flexion, radial deviation, ulnar deviation, pronation, and supination) and grip strength (expressed as a percentage of the contralateral side) were measured. Wrist function was assessed using the Disabilities of the Arm, Shoulder, and Hand (DASH) score and Patient-Rated Wrist Evaluation (PRWE) score.
RESULTS:
The operation time was 70-200 minutes (mean, 116.4 minutes), and the intraoperative blood loss was 10-80 mL (mean, 36.5 mL). All surgical incisions healed by first intention, with no neurovascular complications documented. All patients were followed up 9-12 months (mean, 11.6 months). All fractures healed normally, with a healing time of 8-14 weeks (mean, 9.95 weeks). No significant difference was observed in radial height, volar tilt, or ulnar deviation between immediate postoperatively and last follow-up ( P>0.05). All fractures achieved satisfactory reduction, with no secondary loss of reduction or implant failure occurring during follow-up. At last follow-up, the range of motion of the affected wrist joint was 60°-65° (mean, 62.5°) in extension, 67°-75° (mean, 71.1°) in flexion, 18°-23° (mean, 20.4°) in radial deviation, 28°-33° (mean, 30.1°) in ulnar deviation, 69°-80° (mean, 74.7°) in pronation, and 69°-82° (mean, 75.6°) in supination. Grip strength recovered to 75%-85% (mean, 80%) of the contralateral side. Functional scores showed a DASH score of 5-15 (mean, 9.4) and PRWE score of 8.0-12.5 (mean, 10.2).
CONCLUSION
The combination of Poster Fusion Cage and xenogeneic bone graft augmentation provides a safe and effective treatment for bone defects in distal radius fractures.
Retrospective Studies
;
Humans
;
Male
;
Female
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Treatment Outcome
;
Wrist Fractures/surgery*
;
Heterografts
;
Transplantation, Heterologous/methods*
;
Bone Transplantation/methods*
;
Operative Time
;
Blood Loss, Surgical
;
Radius/surgery*
;
Fracture Healing
;
Time Factors
;
Postoperative Complications/etiology*
;
Range of Motion, Articular
;
Follow-Up Studies
;
Internal Fixators
;
Fracture Fixation, Internal/methods*
;
Combined Modality Therapy
4.Effectiveness analysis of tension band-assisted fixation for volar marginal fractures of distal radius.
Abulimiti MIREADELI ; Wanming QU ; Tianbo ZHU ; Daoxin ZHANG ; Xiaokang ZHU ; Xinzhi LI ; Wenyao CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):662-667
OBJECTIVE:
To investigate the surgical technique and effectiveness of tension band-assisted plate fixation combined with external fixator for volar marginal fractures of the distal radius.
METHODS:
A retrospective analysis was performed on the clinical data of 12 patients with volar marginal fractures of the distal radius treated by Kirschner wire tension band-assisted anatomical plate fixation combined with external fixator between October 2018 and July 2023. The cohort included 9 males and 3 females, aged from 20 to 52 years (mean, 35.5 years). The injury causes included traffic accidents in 6 cases, falls from height in 3 cases, and fall in 3 cases. According to AO/Orthopaedic Trauma Association (AO/OTA), there were 1 case of type B2, 4 cases of type B3, 2 cases of type C1, 3 cases of type C2, and 2 cases of type C3. According to Fernandez classification, there were 2 cases of type Ⅲ, 5 cases of type Ⅳ, and 5 cases of type Ⅴ. Associated injuries included radiocarpal joint dislocation or subluxation in 7 cases and median nerve injury in 2 cases. The time from injury to operation was 2-7 days (mean, 3.2 days). Postoperatively, functional outcomes were evaluated using the modified Mayo wrist score and the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire. Grip strength was measured as the ratio to the unaffected side, and wrist range of motion (ROM) including dorsiflexion, palmar flexion, ulnar deviation, and radial deviation was assessed.
RESULTS:
All procedures were successfully completed, with an operation time of 55-110 minutes (mean, 65 minutes). All patients were followed up 6-36 months (mean, 13.7 months). Surgical incisions healed by first intention, without complications such as vascular-nerve injury or infection. Bony union and articular congruency were attained in all patients, with a healing time of 3-5 months (mean, 3.8 months). During follow-up, 1 case of Kirschner wire migration occurred with no instances of infections, radiocarpal dislocations, internal fixation failures, or extensor pollicis longus tendon ruptures. At last follow-up, the modified Mayo wrist score ranged from 65 to 92 (mean, 80.8), the DASH score ranged from 7 to 15 (mean, 11.6), the grip strength was 65%-90% (mean, 78.2%) of the unaffected side; and wrist ROM was palmar flexion 60°-85° (mean, 77.4°), dorsiflexion 55°-80° (mean, 74.8°), radial deviation 10°-25° (mean, 18.8°), and ulnar deviation 15°-30° (mean, 24.5°).
CONCLUSION
Kirschner wire tension band-assisted anatomical plate fixation combined with external fixator for volar marginal fractures of the distal radius is a simple method with reliable fixation, which can achieve satisfactory effectiveness.
Humans
;
Male
;
Adult
;
Female
;
Radius Fractures/diagnostic imaging*
;
Retrospective Studies
;
Middle Aged
;
Bone Plates
;
Bone Wires
;
External Fixators
;
Young Adult
;
Fracture Fixation, Internal/instrumentation*
;
Treatment Outcome
;
Range of Motion, Articular
;
Hand Strength
;
Wrist Injuries/surgery*
5.Three-dimentional printed personalized guide plate-assisted wrist arthroscopic repair of Palmer type ⅠB triangular fibrocartilage complex injury.
Jin LI ; Zhaoming ZHANG ; Lilian ZHAO ; Lilei HE ; Changbing WANG ; Yanjin LI ; Ting XU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1409-1413
OBJECTIVE:
To investigate the effectiveness of three-dimentional (3D) printed personalized guide plate-assisted wrist arthroscopic repair for Palmer type ⅠB triangular fibrocartilage complex (TFCC) injury.
METHODS:
A retrospective analysis was conducted on the clinical data of 20 patients with Palmer type ⅠB TFCC injuries admitted between January 2023 and March 2024 who met the selection criteria. Among them, 13 were male and 7 were female; ages ranged from 23 to 35 years, with a mean age of 30.3 years. All patients had a history of trauma, 12 cases involved falls and 8 cases involved sprains. All patients demonstrated a positive "piano key sign". MRI revealed deep ulnar-side tears of the TFCC. Conservative treatment for 6 weeks yielded poor or no clinical improvement. The interval from injury to surgery ranged from 2 to 9 months, with a mean of 5.0 months. Patients underwent wrist arthroscopic repair assisted by 3D printed personalized guide plate. Functional recovery was assessed preoperatively and postoperatively using the visual analogue scale (VAS) score for pain, modified Mayo wrist score, and range of motion (ROM) measurements for wrist flexion-extension, ulnar-radial deviation, and pronation-supination. At last follow-up, MRI was performed to evaluate the healing of TFCC.
RESULTS:
All 20 patients underwent successful surgery without complications such as vascular or nerve injury, fracture, incisional infection, or joint stiffness. All patients were followed up 9-18 months (mean, 12.4 months). At last follow-up, patients demonstrated significant improvements in VAS scores, modified Mayo wrist scores, wrist flexion-extension ROM, ulnar-radial deviation ROM, and pronation-supination ROM compared to preoperative levels ( P<0.05). MRI at last follow-up showed preserved TFCC continuity, excellent healing, and secure fixation.
CONCLUSION
3D-printed personalized guide plate significantly improve outcomes in wrist arthroscopic TFCC repair for Palmer type ⅠB injuries. They enable high-quality suturing, facilitate anatomical reconstruction, and markedly enhance wrist function.
Humans
;
Arthroscopy/methods*
;
Male
;
Adult
;
Triangular Fibrocartilage/diagnostic imaging*
;
Female
;
Retrospective Studies
;
Printing, Three-Dimensional
;
Wrist Injuries/diagnostic imaging*
;
Young Adult
;
Bone Plates
;
Treatment Outcome
;
Wrist Joint/surgery*
;
Magnetic Resonance Imaging
;
Range of Motion, Articular
6.Short-term clinical efficacy of unilateral external fixator combined with percutaneous Kirschner wire fixation in the treatment of type C1 distal radius fractures in elderly patients.
Run-Bin SHEN ; Guo-Liang LI ; Xiao-Ping LIU ; Kang CHEN ; Guang-Pu HAN ; Jian-Yong ZHAO
China Journal of Orthopaedics and Traumatology 2025;38(1):25-30
OBJECTIVE:
To investigate the short-term clinical effect of closed reduction single arm external fixator combined with percutaneous needle fixation in the treatment of C1 distal radius fracture in elderly patients.
METHODS:
Between December 2022 and December 2023, a total of 60 elderly patients diagnosed with type C1 distal radius fractures were treated, comprising 9 males and 51 females. The age ranged from 65 to 84 years old, with an average of (72.69±8.14) years old. Among them, there were 18 cases on the left side and 42 cases on the right side. There were 55 cases of falling injury and 5 cases of traffic accident injury. According to the different surgical methods, the patients were divided into observation group and control group, with 30 cases in each group. The control group underwent manual reduction and unilateral external fixator fixation, consisting of 4 males and 26 females. The mean age was (72.54±8.67) years old. The body mass index (BMI) was (20.61±2.17) kg·m-2. There were 10 cases on the left side and 20 cases on the right side. Among them, there were 27 cases of falling injury and 3 cases of traffic accident injury. The observation group was treated with manual reduction and unilateral external fixator combined with percutaneous Kirschner wire fixation, including 5 males and 25 females. The mean age was (72.76±7.23) years old. BMI (20.82±2.03) kg·m-2. The left side was involved in 8 cases and the right side in 22 cases. There were 28 cases of falling injury and 2 cases of traffic accident injury. The changes in radial height, ulnar declination, palmar inclination angle parameters and patient-rated wrist evaluation (PRWE) were assessed on X-ray films before surgery, 2 days after surgery, and 12 weeks after surgery between the two groups.
RESULTS:
All surgical procedures were successfully completed in both groups without any significant complications. All patients were followed up for a duration from 12 to 20 weeks with an average of(14.50±2.78) weeks. The two groups exhibited significant differences in radial height, palmar inclination angle, and ulnar deviation angle at 2 days and 12 weeks post-operation (P<0.05). However, there was no statistically significant difference observed in radial height, palmar inclination, and ulnar deviation between the two groups at 2 days after the operation (P>0.05). There were significant differences in radial height, palmar inclination angle, and ulnar deviation between the two groups at 12 weeks after operation (P<0.05). At 2 days and 12 weeks after the operation, there were significant differences in PRWE scores of the two groups compared with preoperative scores(P<0.05). At 2 days after the operation, there was no significant difference in PRWE score between the two groups (P>0.05). The PRWE score showed a significant difference between the two groups at 12 weeks post-operation(P<0.05).
CONCLUSION
The combination of closed reduction and unilateral external fixator, along with percutaneous pin fixation provides move stable fixation for type C1 distal radius fractures. Gradual removal of external fixator further facilitatse the recovery of wrist joint function.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
External Fixators
;
Aged
;
Aged, 80 and over
;
Bone Wires
;
Fracture Fixation/instrumentation*
;
Wrist Fractures
7.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures
8.Meta-analysis of the efficacy of plate fixation and external fixator fixation in the treatment of AO-C type distal radius fractures.
Guang-Yao LI ; Yong-Zhong CHENG ; Huan LIU ; Jun-Jie JIANG ; Yong-Yao LI ; Yang CHEN ; Yu-Xiang YAO
China Journal of Orthopaedics and Traumatology 2025;38(1):66-80
OBJECTIVE:
Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.
METHODS:
PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database. The database will be established until June 30, 2023. The included studies were extracted according to the Cochrane Handbook (Version 6.3, 2022) for information extraction and literature quality evaluation. RevMan 5.4 was used to evaluate the risk of Publication bias, test heterogeneity and Perform Meta-analysis. The outcome indicators were:imaging anatomy indicators (volar inclination angle, ulnar deviation angle, radial height), wrist joint mobility (flexion, extension, rotation, ulnar deviation), complication rate, and comparison of surgical treatments (operative blood loss, operation time, hospitalization time, fracture healing time) and wrist joint function scores and related scales.
RESULTS:
(1) A total of 28 studies were included, with a total of 2 192 patients, including 1 096 cases in the plate internal fixation group and 1 096 cases in the external fixation group.(2) Meta analysis results showed:the surgical treatment situation of the external fixation group:surgical blood loss MD=-37.93, 95%CI(-48.54, -27.31), P<0.000 01;operation time MD=-31.58, 95%CI(-48.96, -14.20), P<0.000 4;hospitalization time MD=-4.58, 95%CI(-5.44, -3.71), P<0.000 01;the fracture healing time MD=-0.88, 95%CI(-1.35, -0.41), P<0.000 2, which were significantly better than that of the plate internal fixation group(P<0.05).(3) The two groups:palmar inclination angle MD=-0.17, 95%CI(-0.95, 0.61), P=0.68;ulnar declination MD=0.22, 95%CI(-0.73, 1.17), P=0.65, radial height MD=-0.24, 95%CI(-1.15, 0.67), P=0.60;flexion and extension MD=-5.63, 95%CI(-11.85, 0.58), P=0.08;rotation MD=-5.80, 95%CI(-12.77, 1.17), P=0.10, radioulnar deviation MD=-2.86, 95%CI(-10.87, 5.15), P=0.48;complication rate RR=0.96, 95%CI(0.63, 1.46), P=0.83;Gartland-Werley clinical wrist score MD=0.13, 95%CI(-0.80, 1.06), P=0.78;excellent and good rate of Gartland-Werley wrist clinical score RR=0.93, 95%CI(0.87, 1.01), P=0.08;excellent and good rate of Cooney wrist score RR=0.99, 95%CI(0.62, 1.59), P=0.98;wrist DASH score MD=-4.67, 95%CI(-14.96, 5.62), P=0.37;the differences were not significant (P>0.05).
CONCLUSION
Compared with internal fixation with plate, external fixation can significantly reduce the amount of surgical bleeding, shorten the operation time, hospitalization time and fracture healing time, and its imaging anatomical indicators, wrist mobility, and complications can be significantly reduced in treating AO-C distal radius fractures. Rates and wrist function scores were equivalent.
Humans
;
External Fixators
;
Bone Plates
;
Radius Fractures/surgery*
;
Fracture Fixation/methods*
;
Fracture Fixation, Internal
;
Wrist Fractures
9.Application of custom-made joint prostheses in wrist.
Xiaodi ZOU ; Yanzhao DONG ; Changxing WANG ; Hui LU
Journal of Zhejiang University. Science. B 2025;26(2):200-202
The wrist joint is a highly mobile functional joint. Wrist conditions including traumatic and degenerative arthritis, rheumatoid arthritis, and giant cell tumors of the distal radius, cause significant pain and mobility impairment. In joint surgery, the decision to use joint prostheses to reconstruct joint function is greatly influenced by the characteristics of the prosthesis (Mok et al., 2016). However, traditional implants have limitations such as shape mismatch, inadequate implant-bone interface strength which causes loosening, and poor bone ingrowth (Zhang et al., 2014).
Humans
;
Joint Prosthesis
;
Wrist Joint/surgery*
;
Prosthesis Design
;
Arthroplasty, Replacement
;
Arthritis, Rheumatoid/surgery*
10.Arthroscopic treatment of scaphoid fracture nonunion with bone graft and Kirschner wire combined with screw fixation.
Yong LI ; Yongbin FU ; Mingming MA ; Siwei MEI
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(11):1386-1389
OBJECTIVE:
To explore the effectiveness of arthroscopic treatment of scaphoid fracture nonunion with bone graft and Kirschner wire combined with screw fixation.
METHODS:
The clinical data of 14 patients with scaphoid fracture nonunion who met the selection criteria between February 2021 and September 2022 were retrospectively analyzed. There were 13 males and 1 female with an average age of 32 years ranging from 17 to 54 years. The time from injury to operation ranged from 6 to 15 months, with an average of 9.6 months. According to the Slade-Geissler classification of scaphoid fracture nonunion, there were 3 cases of grade Ⅲ, 8 cases of grade Ⅳ, and 3 cases of grade Ⅴ. The preoperative visual analogue scale (VAS) score was 5.9±1.0, and the modified Mayo wrist score was 53.2±9.1. There were 2 cases of scaphoid nonunion advanced collapse, both of which were stage Ⅰ. All patients were treated with arthroscopic bone graft and Kirschner wire combined with screw fixation, and the fracture healing was observed by X-ray film monthly after operation, and the effectiveness was evaluated by VAS score and modified Mayo wrist score before and after operation.
RESULTS:
All patients were followed up 6-14 months, with an average of 8.4 months. All fractures healed in 4-8 months, with an average of 6.3 months. The postoperative pain symptoms and wrist function of the patients significantly improved when compared with those before operation, and the VAS score at last follow-up was 2.4±1.3, and the modified Mayo wrist score was 87.1±6.7, which were significantly different from those before operation ( t=12.851, P<0.001; t=-14.410, P<0.001). According to the modified Mayo wrist evaluation, 9 cases were excellent, 3 cases were good, and 2 cases were fair.
CONCLUSION
Arthroscopic bone graft and Kirschner wire combined with screw fixation is an effective surgical method for the treatment of scaphoid fracture nonunion.
Male
;
Humans
;
Female
;
Adult
;
Fractures, Bone/surgery*
;
Bone Wires
;
Scaphoid Bone/injuries*
;
Retrospective Studies
;
Fracture Fixation, Internal/methods*
;
Fractures, Ununited/surgery*
;
Wrist Injuries/surgery*
;
Bone Screws
;
Hand Injuries
;
Treatment Outcome

Result Analysis
Print
Save
E-mail