1.Carpal Tunnel Syndrome Caused by Idiopathic Tumoral Calcinosis: A Case Report
Joong Hyuk KIM ; Hyeon Gyu LIM ; Jae Hyoung KIM ; Shin Woo NAM ; Il-Tae JANG ; Eui-Jin CHO
The Nerve 2025;11(1):15-20
Carpal tunnel syndrome (CTS) is a common form of hand mononeuropathy that is typi-cally caused by median nerve compression. Although it is often idiopathic, CTS can also result from various conditions, including space-occupying lesions. Tumoral calcinosis, a rare condition characterized by periarticular deposition of calcified masses, is an un-common cause of secondary CTS. We present a case of a 78-year-old woman with idio-pathic tumoral calcinosis that caused secondary CTS. Despite conservative treatments, her symptoms persisted, and diagnostic imaging, including radiographs, computed to-mography, and magnetic resonance imaging, revealed a calcified mass in the carpal tun-nel. A surgical intervention involving carpal tunnel release and excisional biopsy con-firmed the diagnosis of tumoral calcinosis. Postoperatively, the patient showed complete resolution of symptoms, with no recurrence on follow-up radiographs. This case high-lights the importance of considering space-occupying lesions, such as tumoral calcinosis, as a rare but treatable cause of secondary CTS.
2.Comparison between Suture-Button Technique with Syndesmotic Repair and Screw Fixation Technique for Complete Ankle Syndesmotic Injury: Biomechanical Cadaveric Study
Hong Seop LEE ; Sung Hwan KIM ; Ki Won YOUNG ; Woo Jong KIM ; Dong-Il CHEON ; Sung Hun WON ; Sang Heon LEE ; Seung Jin CHOI ; Young Koo LEE
Clinics in Orthopedic Surgery 2025;17(2):324-330
Background:
The tibiofibular syndesmosis is essential for preserving the stability of the ankle. Acute syndesmotic injuries with evident or latent instability usually warrant surgical interventions. This cadaveric study examines and compares biomechanical characteristics between the following treatments for syndesmosis injuries: suture-button fixation plus syndesmotic repair and screw fixation.
Methods:
The lower extremities of 10 cadavers disarticulated at the knee joints were used, yielding 20 feet. Ten feet underwent surgery using the suture-button fixation with syndesmotic repair, while the remaining 10 feet underwent surgery using screw fixation. Before surgical treatment of syndesmosis injuries, each cadaveric lower limb underwent preliminary physiological cyclic loading, which was followed by a series of postfixation cyclic loading tests after the surgical procedure.
Results:
Our principal finding is that suture-button fixation with syndesmotic repair provided torsional strength comparable to that of screw fixation. The mean failure torque did not differ between the 2 groups, but the rotational stiffness was significantly lower in the suture-button fixation/augmentation group.
Conclusions
Suture-button fixation/augmentation facilitates flexible (physiological) syndesmosis movement and may be a useful alternative treatment for ankle syndesmosis injury.
3.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
4.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
5.Clinical Practice Guidelines for Dementia: Recommendations for Cholinesterase Inhibitors and Memantine
Yeshin KIM ; Dong Woo KANG ; Geon Ha KIM ; Ko Woon KIM ; Hee-Jin KIM ; Seunghee NA ; Kee Hyung PARK ; Young Ho PARK ; Gihwan BYEON ; Jeewon SUH ; Joon Hyun SHIN ; YongSoo SHIM ; YoungSoon YANG ; Yoo Hyun UM ; Seong-il OH ; Sheng-Min WANG ; Bora YOON ; Sun Min LEE ; Juyoun LEE ; Jin San LEE ; Jae-Sung LIM ; Young Hee JUNG ; Juhee CHIN ; Hyemin JANG ; Miyoung CHOI ; Yun Jeong HONG ; Hak Young RHEE ; Jae-Won JANG ;
Dementia and Neurocognitive Disorders 2025;24(1):1-23
Background:
and Purpose: This clinical practice guideline provides evidence-based recommendations for treatment of dementia, focusing on cholinesterase inhibitors and N-methyl-D-aspartate (NMDA) receptor antagonists for Alzheimer’s disease (AD) and other types of dementia.
Methods:
Using the Population, Intervention, Comparison, Outcomes (PICO) framework, we developed key clinical questions and conducted systematic literature reviews. A multidisciplinary panel of experts, organized by the Korean Dementia Association, evaluated randomized controlled trials and observational studies. Recommendations were graded for evidence quality and strength using Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) methodology.
Results:
Three main recommendations are presented: (1) For AD, cholinesterase inhibitors (donepezil, rivastigmine, galantamine) are strongly recommended for improving cognition and daily function based on moderate evidence; (2) Cholinesterase inhibitors are conditionally recommended for vascular dementia and Parkinson’s disease dementia, with a strong recommendation for Lewy body dementia; (3) For moderate to severe AD, NMDA receptor antagonist (memantine) is strongly recommended, demonstrating significant cognitive and functional improvements. Both drug classes showed favorable safety profiles with manageable side effects.
Conclusions
This guideline offers standardized, evidence-based pharmacologic recommendations for dementia management, with specific guidance on cholinesterase inhibitors and NMDA receptor antagonists. It aims to support clinical decision-making and improve patient outcomes in dementia care. Further updates will address emerging treatments, including amyloid-targeting therapies, to reflect advances in dementia management.
6.Advanced technique of biportal endoscopic transforaminal lumbar interbody fusion for revision surgery: a technical note
Young-Il KO ; Jin Young LEE ; Hun-Chul KIM ; Hyeon Guk CHO ; Jeong Woo PARK ; Sang-Ho HAN
Asian Spine Journal 2025;19(2):267-274
The application area of biportal endoscopic spine surgery (BESS) is gradually expanding. Compared with conventional fusion surgery, transforaminal interbody fusion (TLIF) using BESS (BESS-TLIF) has the advantages of less bleeding, minimal postoperative pain, and faster recovery. This technical note highlights its application in managing complex conditions such as scar tissue adhesion, altered anatomy, and implant removal, common in reoperations. The method focuses on precise dissection, endoscopic visualization, and careful tissue handling to ensure effective decompression and stabilization. Three representative cases, including reoperations for recurrent disc herniation, adjacent segment disease (ASD) following prior fusion, and ASD with nonunion of the prior fusion site requiring fusion extension, were described. All three cases exhibited clinical improvement following surgery. BESS is an effective and safe method for spinal revision surgery not only in simple decompression surgery but also in cases that required fusion surgery. As BESS is advancing, its role in complex spinal surgeries is expected to expand, potentially setting new standards in minimally invasive spine surgery.
7.Changing Gadolinium-Based Contrast Agents to Prevent Recurrent Acute Adverse Drug Reactions: 6-Year Cohort Study Using Propensity Score Matching
Min Woo HAN ; Chong Hyun SUH ; Pyeong Hwa KIM ; Seonok KIM ; Ah Young KIM ; Kyung-Hyun DO ; Jeong Hyun LEE ; Dong-Il GWON ; Ah Young JUNG ; Choong Wook LEE
Korean Journal of Radiology 2025;26(2):204-204
8.F‑18 FDG PET/CT Clinical Service Trends in Korea from 2018 to 2022:A National Surveillance Study
Jaesun YOON ; Heejin KIM ; Do Hyun WOO ; Seung Yeop CHAE ; Ji Heui LEE ; Inki LEE ; Ilhan LIM ; Byung Il KIM ; Chang Woon CHOI ; Byung Hyung BYUN
Nuclear Medicine and Molecular Imaging 2025;59(2):117-124
Objectives:
To assess the trends and disparities in the utilization of F-18 fluorodeoxyglucose positron emission tomography/ computed tomography (FDG PET/CT) in Korea between 2018 and 2022, with a focus on disease classification, patient demographics, and regional distribution.
Methods:
This national surveillance retrospective study uses data from the Health Insurance Review and Assessment Service (HIRA) database, which includes all FDG PET/CT examinations conducted in Korea from 2018 to 2022. Disease classifications, cancer types, age groups, gender, and geographic regions were analyzed using descriptive statistics. Utilization rates per 100,000 population were calculated for regional comparisons.
Results:
FDG PET/CT utilization increased by 25.4%, from 174,885 examinations in 2018 to 219,377 in 2022. Older age groups (60 years and above) accounted for the majority of examinations, with males undergoing more examinations than females. Oncology remained the primary indication, with lung, colorectal, and non-Hodgkin lymphoma leading in examination numbers. The number of examinations performed on patients aged 60 and above increased at a higher rate compared to those under 60. Significant geographic disparities were found, with Seoul reporting the highest utilization rate (1,114.3 examinations per 100,000 population), while Gyeongbuk exhibited much lower rate (26.2 examinations per 100,000 population).
Conclusions
This study highlights the growing utilization of FDG PET/CT in Korea, particularly among older adults, with significant gender differences in cancer types. The findings also reveal disparities in FDG PET/CT utilization across regions, indicating varying access to advanced imaging technology.
9.Pre-Treatment Perceived Social Support Is Associated With Chemotherapy-Induced Peripheral Neuropathy in Patients With Breast Cancer: A Longitudinal Study
Joon Sung SHIN ; Sanghyup JUNG ; Geun Hui WON ; Sun Hyung LEE ; Jaehyun KIM ; Saim JUNG ; Chan-Woo YEOM ; Kwang-Min LEE ; Kyung-Lak SON ; Jang-il KIM ; Sook Young JEON ; Han-Byoel LEE ; Bong-Jin HAHM
Psychiatry Investigation 2025;22(4):424-434
Objective:
Previous studies have reported an association between cancer-related symptoms and perceived social support (PSS). The objective of this study was to analyze whether Chemotherapy-Induced Peripheral Neuropathy (CIPN), a prevalent side effect of chemotherapy, varies according to PSS level using a validated tool for CIPN at prospective follow-up.
Methods:
A total of 39 breast cancer patients were evaluated for PSS using the Multidimensional Scale of Perceived Social Support (MSPSS) prior to chemotherapy and were subsequently grouped into one of two categories for each subscale: low-to-moderate PSS and high PSS. CIPN was prospectively evaluated using the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire-Chemotherapy-Induced Peripheral Neuropathy 20 (CIPN20) at five time points. A linear mixed-effects model with square root transformation was employed to investigate whether the CIPN20 scales varied by PSS level and time point.
Results:
Statistical analysis of the MSPSS total scale and subscales revealed a significant effect of the friends subscale group and time point on the CIPN20 sensory scale. The sensory scale score of CIPN20 was found to be lower in participants with high PSS from friends in comparison to those with low-to-moderate PSS at 1 month post-chemotherapy (p=0.010).
Conclusion
This is the first study to prospectively follow the long-term effect of pre-treatment PSS from friends on CIPN. Further studies based on larger samples are required to analyze the effects of PSS on the pathophysiology of CIPN.
10.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

Result Analysis
Print
Save
E-mail