1.Primary Cutaneous CD30+ Lymphoproliferative Disorders in South Korea: A Nationwide, Multi-Center, Retrospective, Clinical, and Prognostic Study
Woo Jin LEE ; Sook Jung YUN ; Joon Min JUNG ; Joo Yeon KO ; Kwang Ho KIM ; Dong Hyun KIM ; Myung Hwa KIM ; You Chan KIM ; Jung Eun KIM ; Chan-Ho NA ; Je-Ho MUN ; Jong Bin PARK ; Ji-Hye PARK ; Hai-Jin PARK ; Dong Hoon SHIN ; Jeonghyun SHIN ; Sang Ho OH ; Seok-Kweon YUN ; Dongyoun LEE ; Seok-Jong LEE ; Seung Ho LEE ; Young Bok LEE ; Soyun CHO ; Sooyeon CHOI ; Jae Eun CHOI ; Mi Woo LEE ; On behalf of The Korean Society of Dermatopathology
Annals of Dermatology 2025;37(2):75-85
Background:
Primary cutaneous CD30+ lymphoproliferative disorders (pcCD30-LPDs) are a diseases with various clinical and prognostic characteristics.
Objective:
Increasing our knowledge of the clinical characteristics of pcCD30-LPDs and identifying potential prognostic variables in an Asian population.
Methods:
Clinicopathological features and survival data of pcCD30-LPD cases obtained from 22 hospitals in South Korea were examined.
Results:
A total of 413 cases of pcCD30-LPDs (lymphomatoid papulosis [LYP], n=237; primary cutaneous anaplastic large cell lymphoma [C-ALCL], n=176) were included. Ninety percent of LYP patients and roughly 50% of C-ALCL patients presented with multiple skin lesions. Both LYP and C-ALCL affected the lower limbs most frequently. Multiplicity and advanced T stage of LYP lesions were associated with a chronic course longer than 6 months. Clinical morphology with patch lesions and elevated serum lactate dehydrogenase were significantly associated with LPDs during follow-up in LYP patients. Extracutaneous involvement of C-ALCL occurred in 13.2% of patients. Lesions larger than 5 cm and increased serum lactate dehydrogenase were associated with a poor prognosis in C-ALCL. The survival of patients with C-ALCL was unaffected by the anatomical locations of skin lesions or other pathological factors.
Conclusion
The multiplicity or size of skin lesions was associated with a chronic course of LYP and survival among patients with C-ALCL.
2.A Novel Fibrinogen Assay Using Recombinant Batroxobin and Carboxymethyl Chitosan:Carboxymethyl Chitosan Stimulates the Enzymatic Activity of Recombinant Batroxobin
Jung-Ah KIM ; Eunhye KO ; Yongje WOO ; Young-Doug SOHN ; Jong-Tak KIM ; Jaewoo SONG ; Rojin PARK
Annals of Laboratory Medicine 2025;45(5):484-492
Background:
The Clauss assay is widely used to quantify blood fibrinogen levels in clinical laboratories. However, by relying on thrombin as the main reagent, the Clauss assay is susceptible to interference from thrombin inhibitors, such as heparin or direct thrombin inhibitors. Here, we developed an innovative fibrinogen assay utilizing both recombinant batroxobin (rBat) and carboxymethyl chitosan (CMCS).
Methods:
Various biopolymers were tested to identify a suitable candidate that could enhance rBat-induced fibrin clot formation. Chromogenic substrate hydrolysis and sodium dodecyl sulfate-polyacrylamide gel electrophoresis analysis showed that CMCS potentiated rBat activity. Consequently, we formulated a novel fibrinogen assay reagent, ANYFIB.C, comprising rBat and CMCS. We compared ANYFIB.C fibrinogen with an established reagent (HemosIL fibrinogen-C) with 96 clinical samples using an ACL-TOP 700 coagulation analyzer. We also evaluated the interfering effects of thrombin inhibitors on fibrinogen measurements.
Results:
CMCS significantly enhanced the enzymatic activity of rBat and dose-dependently reduced plasma clotting times. ANYFIB.C fibrinogen levels were comparable with those of HemosIL fibrinogen-C, with the 95% confidence intervals of the Passing–Bablok regres-sion intercept and slope being −7.4797 to 6.0185 and 0.9581 to 1.0116, respectively. Nosignificant interference was observed with heparin concentrations up to 10 U/mL or dabigatran concentrations up to 600 µg/L in the ANYFIB.C fibrinogen assays. In contrast, the HemosIL fibrinogen-C reagent demonstrated inhibitory interference at dabigatran concentrations as low as 150 µg/L.
Conclusions
Our results suggest that ANYFIB.C (a mixture of CMCS and rBat) can be used to measure blood fibrinogen levels effectively and protect from thrombin inhibitor interference.
3.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
4.Clinical Exome-Based Redefinition and Reclassification of Retinitis Pigmentosa
Hyo Song PARK ; Kyung KIM ; Dongwook LEE ; Jong-Young LEE ; Jeong Nam CHOI ; Jin Ha KIM ; Jung Woo HAN ; Tae Kwann PARK
Journal of Korean Medical Science 2025;40(16):e54-
Background:
Because of the low prevalence of inherited retinal diseases, reports on the distribution of retinitis pigmentosa (RP)-related genes in Korean patients are scarce. The aim of this study was to determine the mutation spectrum and allele frequency and observe the final diagnoses in a Korean cohort clinically diagnosed with RP.
Methods:
We used whole-exome sequencing (WES) to analyze a Korean cohort of 100 unrelated patients clinically diagnosed with RP. The possible pathogenicity of each variant was assessed based on the guidelines of the American College of Medical Genetics and Genomics and Association for Molecular Pathology, in-silico prediction tools, known clinical phenotypes, and inheritance patterns.
Results:
Definite causative genes were detected in 60/100 patients (60.0%). Of these 60 cases, USH2A was the most common causative gene (14/60, 23.3%), followed by EYS (13/60, 21.7%) and RP1 (6/60, 10.0%). The clinical diagnosis was redefined in 9 of the 60 probands (15.0%) with causative genes after WES. Five of the 60 patients (8.3%) carried a causative variant in CHM, and the clinical diagnosis was redefined as choroideremia. Leber congenital amaurosis was diagnosed in 2/60 probands (3.3%), and RDH12 and RPGRIP1 were the causative genes in each patient. One patient (1/60, 1.7%) was diagnosed with Bietti’s crystalline dystrophy, with CYP4V2 identified as the causative gene. In another patient (1/60, 1.7%), ABCA4 variants were detected with clinical findings suggestive of cone-rod dystrophy.
Conclusion
This study reports the mutational spectrum of a cohort of Korean patients with a clinical diagnosis of RP who were referred for genetic testing. This study adds valuable data regarding the frequency of genes as well as their relation to the age of symptom onset and relation to other inherited retinal degenerations.
5.A Study on the Healthcare Workforce and Care for Acute Stroke: Results From the Survey of Hospitals Included in the National Acute Stroke Quality Assessment Program
Jong Young LEE ; Jun Kyeong KO ; Hak Cheol KO ; Hae-Won KOO ; Hyon-Jo KWON ; Dae-Won KIM ; Kangmin KIM ; Myeong Jin KIM ; Hoon KIM ; Keun Young PARK ; Kuhyun YANG ; Jae Sang OH ; Won Ki YOON ; Dong Hoon LEE ; Ho Jun YI ; Heui Seung LEE ; Jong-Kook RHIM ; Dong-Kyu JANG ; Youngjin JUNG ; Sang Woo HA ; Seung Hun SHEEN
Journal of Korean Medical Science 2025;40(16):e44-
Background:
With growing elderly populations, management of patients with acute stroke is increasingly important. In South Korea, the Acute Stroke Quality Assessment Program (ASQAP) has contributed to improving the quality of stroke care and practice behavior in healthcare institutions. While the mortality of hemorrhagic stroke remains high, there are only a few assessment indices associated with hemorrhagic stroke. Considering the need to develop assessment indices to improve the actual quality of care in the field of acute stroke treatment, this study aims to investigate the current status of human resources and practices related to the treatment of patients with acute stroke through a nationwide survey.
Methods:
For the healthcare institutions included in the Ninth ASQAP of the Health Insurance Review and Assessment Service (HIRA), data from January 2022 to December 2022 were collected through a survey on the current status and practice of healthcare providers related to the treatment of patients with acute stroke. The questionnaire consisted of 19 items, including six items on healthcare providers involved in stroke care and 10 items on the care of patients with acute stroke.
Results:
In the treatment of patients with hemorrhagic stroke among patients with acute stroke, neurosurgeons were the most common providers. The contribution of neurosurgeons in the treatment of ischemic stroke has also been found to be equivalent to that of neurologists. However, a number of institutions were found to be devoid of healthcare providers who perform definitive treatments, such as intra-arterial thrombectomy for patients with ischemic stroke or cerebral aneurysm clipping for subarachnoid hemorrhage. The intensity of the workload of healthcare providers involved in the care of patients with acute stroke, especially those involved in definitive treatment, was also found to be quite high.
Conclusion
Currently, there are almost no assessment indices specific to hemorrhagic stroke in the ASQAP for acute stroke. Furthermore, it does not reflect the reality of the healthcare providers and practices that provide definitive treatment for acute stroke. The findings of this study suggest the need for the development of appropriate assessment indices that reflect the realities of acute stroke care.
6.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
7.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
8.Clinical Exome-Based Redefinition and Reclassification of Retinitis Pigmentosa
Hyo Song PARK ; Kyung KIM ; Dongwook LEE ; Jong-Young LEE ; Jeong Nam CHOI ; Jin Ha KIM ; Jung Woo HAN ; Tae Kwann PARK
Journal of Korean Medical Science 2025;40(16):e54-
Background:
Because of the low prevalence of inherited retinal diseases, reports on the distribution of retinitis pigmentosa (RP)-related genes in Korean patients are scarce. The aim of this study was to determine the mutation spectrum and allele frequency and observe the final diagnoses in a Korean cohort clinically diagnosed with RP.
Methods:
We used whole-exome sequencing (WES) to analyze a Korean cohort of 100 unrelated patients clinically diagnosed with RP. The possible pathogenicity of each variant was assessed based on the guidelines of the American College of Medical Genetics and Genomics and Association for Molecular Pathology, in-silico prediction tools, known clinical phenotypes, and inheritance patterns.
Results:
Definite causative genes were detected in 60/100 patients (60.0%). Of these 60 cases, USH2A was the most common causative gene (14/60, 23.3%), followed by EYS (13/60, 21.7%) and RP1 (6/60, 10.0%). The clinical diagnosis was redefined in 9 of the 60 probands (15.0%) with causative genes after WES. Five of the 60 patients (8.3%) carried a causative variant in CHM, and the clinical diagnosis was redefined as choroideremia. Leber congenital amaurosis was diagnosed in 2/60 probands (3.3%), and RDH12 and RPGRIP1 were the causative genes in each patient. One patient (1/60, 1.7%) was diagnosed with Bietti’s crystalline dystrophy, with CYP4V2 identified as the causative gene. In another patient (1/60, 1.7%), ABCA4 variants were detected with clinical findings suggestive of cone-rod dystrophy.
Conclusion
This study reports the mutational spectrum of a cohort of Korean patients with a clinical diagnosis of RP who were referred for genetic testing. This study adds valuable data regarding the frequency of genes as well as their relation to the age of symptom onset and relation to other inherited retinal degenerations.
9.A Study on the Healthcare Workforce and Care for Acute Stroke: Results From the Survey of Hospitals Included in the National Acute Stroke Quality Assessment Program
Jong Young LEE ; Jun Kyeong KO ; Hak Cheol KO ; Hae-Won KOO ; Hyon-Jo KWON ; Dae-Won KIM ; Kangmin KIM ; Myeong Jin KIM ; Hoon KIM ; Keun Young PARK ; Kuhyun YANG ; Jae Sang OH ; Won Ki YOON ; Dong Hoon LEE ; Ho Jun YI ; Heui Seung LEE ; Jong-Kook RHIM ; Dong-Kyu JANG ; Youngjin JUNG ; Sang Woo HA ; Seung Hun SHEEN
Journal of Korean Medical Science 2025;40(16):e44-
Background:
With growing elderly populations, management of patients with acute stroke is increasingly important. In South Korea, the Acute Stroke Quality Assessment Program (ASQAP) has contributed to improving the quality of stroke care and practice behavior in healthcare institutions. While the mortality of hemorrhagic stroke remains high, there are only a few assessment indices associated with hemorrhagic stroke. Considering the need to develop assessment indices to improve the actual quality of care in the field of acute stroke treatment, this study aims to investigate the current status of human resources and practices related to the treatment of patients with acute stroke through a nationwide survey.
Methods:
For the healthcare institutions included in the Ninth ASQAP of the Health Insurance Review and Assessment Service (HIRA), data from January 2022 to December 2022 were collected through a survey on the current status and practice of healthcare providers related to the treatment of patients with acute stroke. The questionnaire consisted of 19 items, including six items on healthcare providers involved in stroke care and 10 items on the care of patients with acute stroke.
Results:
In the treatment of patients with hemorrhagic stroke among patients with acute stroke, neurosurgeons were the most common providers. The contribution of neurosurgeons in the treatment of ischemic stroke has also been found to be equivalent to that of neurologists. However, a number of institutions were found to be devoid of healthcare providers who perform definitive treatments, such as intra-arterial thrombectomy for patients with ischemic stroke or cerebral aneurysm clipping for subarachnoid hemorrhage. The intensity of the workload of healthcare providers involved in the care of patients with acute stroke, especially those involved in definitive treatment, was also found to be quite high.
Conclusion
Currently, there are almost no assessment indices specific to hemorrhagic stroke in the ASQAP for acute stroke. Furthermore, it does not reflect the reality of the healthcare providers and practices that provide definitive treatment for acute stroke. The findings of this study suggest the need for the development of appropriate assessment indices that reflect the realities of acute stroke care.
10.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.

Result Analysis
Print
Save
E-mail