1.Impact of single-port laparoscopic approach on scar assessment by patients and observers: a multicenter retrospective study
Sung Uk BAE ; Kyeong Eui KIM ; Chang-Woo KIM ; Ji-Hoon KIM ; Woon Kyung JEONG ; Yoon-Suk LEE ; Seong Kyu BAEK ; Suk-Hwan LEE ; Jun-Gi KIM
Annals of Coloproctology 2025;41(2):154-161
Purpose:
This study aimed to compare the wound cosmesis of a single-incision approach on scar assessment after laparoscopic surgery for colon cancer.
Methods:
This study included 32 patients undergoing single-port laparoscopic surgery (SPLS) and 61 patients undergoing multiport laparoscopic surgery (MPLS) for colon cancer at 3 tertiary referral hospitals between September 2011 and December 2019. We modified and applied the Korean version of the Patient and Observer Scar Assessment Scale (POSAS) to assess cosmetic outcomes. To assess the interobserver reliability using intraclass correlation coefficient values for the Observer Scar Assessment Scale (OSAS), the surgeons evaluated 5 images of postoperative scars.
Results:
No significant differences were observed in the time before the return of normal bowel function, time to sips of water and soft diet initiation, length of in-hospital stay, and postoperative complication rate. The SPLS group had a shorter total incision length than the MPLS group. The POSAS favored the SPLS approach, revealing significant differences in the Patient Scar Assessment Scale (PSAS), OSAS, and overall scores. The SPLS approach was an independent factor influencing the POSAS, PSAS, and OSAS scores. Eleven colorectal surgeons had a significantly substantial intraclass coefficient.
Conclusion
The cosmetic outcomes of SPLS as assessed by the patients and surgeons were superior to those of MPLS in colon cancer. Reducing the number of ports is an independent factor affecting scar assessment by patients and observers.
2.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
3.Persistent influence of past obesity on current adiponectin levels and mortality in patients with type 2 diabetes
Min-Ji KIM ; Sung-Woo KIM ; Bitna HA ; Hyang Sook KIM ; So-Hee KWON ; Jonghwa JIN ; Yeon-Kyung CHOI ; Keun-Gyu PARK ; Jung Guk KIM ; In-Kyu LEE ; Jae-Han JEON
The Korean Journal of Internal Medicine 2025;40(2):299-309
Background/Aims:
Adiponectin, a hormone primarily produced by adipocytes, typically shows an inverse relationship with body mass index (BMI). However, some studies have reported a positive correlation between the two. Thus, this study aimed to examine the relationship between adiponectin level and BMI in diabetic patients, focusing on the impact of past obesity on current adiponectin levels.
Methods:
We conducted an observational study analyzing data from 323 diabetic patients at Kyungpook National University Hospital. Based on past and current BMIs, participants were categorized into never-obese (nn, n = 106), previously obese (on, n = 43), and persistently obese (oo, n = 73) groups based on a BMI threshold of 25 kg/m2. Adiponectin level and BMI were key variables. Kaplan–Meier analysis assessed their impact on all-cause mortality up to August 2023, with survival differences based on adiponectin quartiles and follow-up starting from patient enrollment (2010–2015).
Results:
The analysis revealed a significant inverse correlation between adiponectin level and past maximum BMI. The on group exhibited approximately 10% lower adiponectin levels compared to the nn group. This association remained significant after adjusting for current BMI, age, and sex, highlighting the lasting influence of previous obesity on adiponectin levels. Furthermore, survival analysis indicated that patients in the lowest adiponectin quartile had reduced survival, with a statistically significant trend (p = 0.062).
Conclusions
Findings of this study suggest that lower adiponectin levels, potentially reflecting past obesity, are associated with decreased survival in diabetic patients, underscoring a critical role of adiponectin in long-term health outcomes.
4.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
5.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
6.Pre-Treatment Perceived Social Support Is Associated With Chemotherapy-Induced Peripheral Neuropathy in Patients With Breast Cancer: A Longitudinal Study
Joon Sung SHIN ; Sanghyup JUNG ; Geun Hui WON ; Sun Hyung LEE ; Jaehyun KIM ; Saim JUNG ; Chan-Woo YEOM ; Kwang-Min LEE ; Kyung-Lak SON ; Jang-il KIM ; Sook Young JEON ; Han-Byoel LEE ; Bong-Jin HAHM
Psychiatry Investigation 2025;22(4):424-434
Objective:
Previous studies have reported an association between cancer-related symptoms and perceived social support (PSS). The objective of this study was to analyze whether Chemotherapy-Induced Peripheral Neuropathy (CIPN), a prevalent side effect of chemotherapy, varies according to PSS level using a validated tool for CIPN at prospective follow-up.
Methods:
A total of 39 breast cancer patients were evaluated for PSS using the Multidimensional Scale of Perceived Social Support (MSPSS) prior to chemotherapy and were subsequently grouped into one of two categories for each subscale: low-to-moderate PSS and high PSS. CIPN was prospectively evaluated using the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire-Chemotherapy-Induced Peripheral Neuropathy 20 (CIPN20) at five time points. A linear mixed-effects model with square root transformation was employed to investigate whether the CIPN20 scales varied by PSS level and time point.
Results:
Statistical analysis of the MSPSS total scale and subscales revealed a significant effect of the friends subscale group and time point on the CIPN20 sensory scale. The sensory scale score of CIPN20 was found to be lower in participants with high PSS from friends in comparison to those with low-to-moderate PSS at 1 month post-chemotherapy (p=0.010).
Conclusion
This is the first study to prospectively follow the long-term effect of pre-treatment PSS from friends on CIPN. Further studies based on larger samples are required to analyze the effects of PSS on the pathophysiology of CIPN.
7.Persistent influence of past obesity on current adiponectin levels and mortality in patients with type 2 diabetes
Min-Ji KIM ; Sung-Woo KIM ; Bitna HA ; Hyang Sook KIM ; So-Hee KWON ; Jonghwa JIN ; Yeon-Kyung CHOI ; Keun-Gyu PARK ; Jung Guk KIM ; In-Kyu LEE ; Jae-Han JEON
The Korean Journal of Internal Medicine 2025;40(2):299-309
Background/Aims:
Adiponectin, a hormone primarily produced by adipocytes, typically shows an inverse relationship with body mass index (BMI). However, some studies have reported a positive correlation between the two. Thus, this study aimed to examine the relationship between adiponectin level and BMI in diabetic patients, focusing on the impact of past obesity on current adiponectin levels.
Methods:
We conducted an observational study analyzing data from 323 diabetic patients at Kyungpook National University Hospital. Based on past and current BMIs, participants were categorized into never-obese (nn, n = 106), previously obese (on, n = 43), and persistently obese (oo, n = 73) groups based on a BMI threshold of 25 kg/m2. Adiponectin level and BMI were key variables. Kaplan–Meier analysis assessed their impact on all-cause mortality up to August 2023, with survival differences based on adiponectin quartiles and follow-up starting from patient enrollment (2010–2015).
Results:
The analysis revealed a significant inverse correlation between adiponectin level and past maximum BMI. The on group exhibited approximately 10% lower adiponectin levels compared to the nn group. This association remained significant after adjusting for current BMI, age, and sex, highlighting the lasting influence of previous obesity on adiponectin levels. Furthermore, survival analysis indicated that patients in the lowest adiponectin quartile had reduced survival, with a statistically significant trend (p = 0.062).
Conclusions
Findings of this study suggest that lower adiponectin levels, potentially reflecting past obesity, are associated with decreased survival in diabetic patients, underscoring a critical role of adiponectin in long-term health outcomes.
8.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
9.Outcomes of Deferring Percutaneous Coronary Intervention Without Physiologic Assessment for Intermediate Coronary Lesions
Jihoon KIM ; Seong-Hoon LIM ; Joo-Yong HAHN ; Jin-Ok JEONG ; Yong Hwan PARK ; Woo Jung CHUN ; Ju Hyeon OH ; Dae Kyoung CHO ; Yu Jeong CHOI ; Eul-Soon IM ; Kyung-Heon WON ; Sung Yun LEE ; Sang-Wook KIM ; Ki Hong CHOI ; Joo Myung LEE ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Seung-Hyuk CHOI ; Hyeon-Cheol GWON
Korean Circulation Journal 2025;55(3):185-195
Background and Objectives:
Outcomes of deferring percutaneous coronary intervention (PCI) without invasive physiologic assessment for intermediate coronary lesions is uncertain.We sought to compare long-term outcomes between medical treatment and PCI of intermediate lesions without invasive physiologic assessment.
Methods:
A total of 899 patients with intermediate coronary lesions between 50% and 70% diameter-stenosis were randomized to the conservative group (n=449) or the aggressive group (n=450). For intermediate lesions, PCI was performed in the aggressive group, but was deferred in the conservative group. The primary endpoint was major adverse cardiac events (MACE, a composite of all-cause death, myocardial infarction [MI], or ischemia-driven any revascularization) at 3 years.
Results:
The number of treated lesions per patient was 0.8±0.9 in the conservative group and 1.7±0.9 in the aggressive group (p=0.001). At 3 years, the conservative group had a significantly higher incidence of MACE than the aggressive group (13.8% vs. 9.3%; hazard ratio [HR], 1.49; 95% confidence interval [CI], 1.00–2.21; p=0.049), mainly driven by revascularization of target intermediate lesion (6.5% vs. 1.1%; HR, 5.69; 95% CI, 2.20–14.73;p<0.001). Between 1 and 3 years after the index procedure, compared to the aggressive group, the conservative group had significantly higher incidence of cardiac death or MI (3.2% vs.0.7%; HR, 4.34; 95% CI, 1.24–15.22; p=0.022) and ischemia-driven any revascularization.
Conclusions
For intermediate lesions, medical therapy alone, guided only by angiography, was associated with a higher risk of MACE at 3 years compared with performing PCI, mainly due to increased revascularization.
10.Age Estimation Using Attrition and Pulp Cavity Size of the Mandibular First Molar in Korean Population
Hee-Won KIM ; Hye-Mi JEON ; Kyung-Hee KIM ; Hye-Min JU ; Soo-Min OK ; Sung-Hee JEONG ; Yong-Woo AHN
Korean Journal of Legal Medicine 2025;49(1):1-6
In forensic science, age estimation is essential for identifying both living and deceased individuals. Teeth and jawbones serve as reliable indicators due to their gradual age-related changes and resistance to environmental factors. Among the various methods, attrition and pulp cavity size are commonly used to estimate adult age. This study aimed to enhance the accuracy of age estimation in Korean adults by combining measurements of tooth attrition and pulp cavity size obtained from panoramic radiographs of mandibular first molars. We evaluated 118 patients (62 male, 56 female) who visited Pusan National University Dental Hospital between 2010 and 2024. Radiographs and clinical photographs were analyzed for grade C teeth with exposed dentin using Takei’s method, and the pulp chamber height ratio (PCHR) and width ratio (PCWR) were measured using Jeon’s method. Intraobserver reliability was high (intraclass correlation coefficient>0.6), with no significant sex-based differences in PCHR and PCWR. Both ratios negatively correlated with age, with PCWR showing a stronger correlation, particularly in females (r=–0.606). This study derived an improved age estimation formula with R² values ranging from 0.540 to 0.546 when both PCHR and PCWR were combined. Despite the limitations of this study, such as its small sample size and reliance on panoramic radiographs, the findings suggest that combining tooth wear and pulp cavity size offers a more robust tool for age estimation in clinical and forensic settings.

Result Analysis
Print
Save
E-mail