1.Robot-assisted ureteral reconstruction for managing kidney transplant patients with ureteric complications
Dongho SHIN ; San KANG ; Seung Ah RHEW ; Chang Eil YOON ; Hyong Woo MOON ; Yong Hyun PARK ; Hyuk Jin CHO
Investigative and Clinical Urology 2025;66(1):18-26
Purpose:
To evaluate the feasibility of robot-assisted ureteral reconstruction as a minimally invasive alternative to open surgery for managing ureteric complications in transplanted kidneys.
Materials and Methods:
From January 2020 to December 2023, robot-assisted ureteral reconstruction was performed on fifteen kidney transplant patients with vesicoureteral reflux (VUR) or ureteral stricture who had previously failed endoscopic treatments.
Results:
Twelve females and three males, with a mean age of 48.6±6.6 years, were included in the study. Nine patients (60.0%) underwent surgery due to VUR (grade III or higher) of the transplanted kidney, and six patients (40.0%) had transplanted ureteral strictures. Postoperative voiding cystourethrogram (VCUG) was performed at 3.2±1.6 months. Seven patients (77.8%) became VUR-free, while two patients (22.2%) had VUR regression from grade IV to I. All six patients who underwent reconstruction due to anastomosis site stricture became stenosis-free without the need for an indwelling ureteral catheter. In cases where the ureter was too short for reimplantation, a Boari flap or end-to-end anastomosis with the native ureter was performed. The mean hospital stay was 5.9±4.5 days. The urethral catheter was removed after 15.1±5.4 days, and the ureteral catheter was removed after 4.9±1.5 weeks. The mean follow-up period was 23.9±6.8 months, with no additional interventions required after surgery. No complications above Clavien-Dindo grade I were recorded.
Conclusions
Robotic ureteral reconstruction is technically feasible and offers an effective, minimally invasive treatment for ureteric complications in kidney transplant patients, serving as an alternative to open surgery.
2.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
3.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
4.Intralesional Triamcinolone Acetonide Injection as a Treatment for Granulomatous Tissue on Tracheocutaneous Stoma
Min Woo KIM ; Myung Ho JIN ; Jong Kwan KIM ; Dong Sik CHANG
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(2):62-66
Background and Objectives:
The aim of this study was to confirm the effect of intralesional triamcinolone acetonide injections (TRIAM) to treat granulomatous tissue surrounding the tracheostomy stoma.Subjects and Method We reviewed and documented the medical charts of 20 patients who were administered with TRIAM to treat granulomatous tissue surrounding the tracheostomy stoma from January 2018 to June 2019 were. The surface area of the granulomatous tissue was measured using Image J. The differences between the area of the granulomatous tissue after conventional treatment and after TRIAM on the same patient were compared.
Results:
A total of 20 patients consisting of 12 males and 8 females were included, with the patients’ average age being 60.0±14.3 years. The initial surface area of granulation tissue was 1.266±0.449 cm2, and 1.243±0.432 cm2 after conventional treatment, showing no statistically significant difference in the tissue area (p=0.143). The pre-injection surface area of granulation tissue was 1.243±0.432 cm2, and the area on the 7th day after the third injection was 0.477±0.217 cm2, showing a significant difference (p<0.001).
Conclusion
Compared to the conventional treatment, the surface area of granulomatous tissue surrounding the tracheostomy stoma significantly decreased after being treating with TRIAM. This finding suggests the effectiveness of TRIAM as a treatment of granulomatous tissue surrounding the tracheostomy stoma without complications such as bleeding.
6.Eosinophilic Cholangitis Diagnosed in a Patient with Abnormal Liver Enzymes: A Case Report
Sung Hoon CHANG ; Jun Yeol KIM ; Yong Soo SONG ; Tae Seung LEE ; Jin Ho CHOI ; Woo Hyun PAIK ; Sang Hyub LEE ; Ji Kon RYU ; In Rae CHO
Korean Journal of Pancreas and Biliary Tract 2025;30(1):19-25
It is difficult to determine a cause of bile duct stricture and dilatation. Eosinophilic cholangitis, a rare benign condition, may be one cause of bile duct stricture and dilatation. It can be evaluated using various methods of histopathology, radiographs, endoscopy, and hematologic findings. Treatment generally involves steroid therapy which can lead to improvement. This case report will discuss eosinophilic cholangitis, emphasizing that while it can easily be overlooked but should be considered in differential diagnoses.
7.Intralesional Triamcinolone Acetonide Injection as a Treatment for Granulomatous Tissue on Tracheocutaneous Stoma
Min Woo KIM ; Myung Ho JIN ; Jong Kwan KIM ; Dong Sik CHANG
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(2):62-66
Background and Objectives:
The aim of this study was to confirm the effect of intralesional triamcinolone acetonide injections (TRIAM) to treat granulomatous tissue surrounding the tracheostomy stoma.Subjects and Method We reviewed and documented the medical charts of 20 patients who were administered with TRIAM to treat granulomatous tissue surrounding the tracheostomy stoma from January 2018 to June 2019 were. The surface area of the granulomatous tissue was measured using Image J. The differences between the area of the granulomatous tissue after conventional treatment and after TRIAM on the same patient were compared.
Results:
A total of 20 patients consisting of 12 males and 8 females were included, with the patients’ average age being 60.0±14.3 years. The initial surface area of granulation tissue was 1.266±0.449 cm2, and 1.243±0.432 cm2 after conventional treatment, showing no statistically significant difference in the tissue area (p=0.143). The pre-injection surface area of granulation tissue was 1.243±0.432 cm2, and the area on the 7th day after the third injection was 0.477±0.217 cm2, showing a significant difference (p<0.001).
Conclusion
Compared to the conventional treatment, the surface area of granulomatous tissue surrounding the tracheostomy stoma significantly decreased after being treating with TRIAM. This finding suggests the effectiveness of TRIAM as a treatment of granulomatous tissue surrounding the tracheostomy stoma without complications such as bleeding.
9.Eosinophilic Cholangitis Diagnosed in a Patient with Abnormal Liver Enzymes: A Case Report
Sung Hoon CHANG ; Jun Yeol KIM ; Yong Soo SONG ; Tae Seung LEE ; Jin Ho CHOI ; Woo Hyun PAIK ; Sang Hyub LEE ; Ji Kon RYU ; In Rae CHO
Korean Journal of Pancreas and Biliary Tract 2025;30(1):19-25
It is difficult to determine a cause of bile duct stricture and dilatation. Eosinophilic cholangitis, a rare benign condition, may be one cause of bile duct stricture and dilatation. It can be evaluated using various methods of histopathology, radiographs, endoscopy, and hematologic findings. Treatment generally involves steroid therapy which can lead to improvement. This case report will discuss eosinophilic cholangitis, emphasizing that while it can easily be overlooked but should be considered in differential diagnoses.
10.Comparison of Finasteride and Dutasteride on Risk of Prostate Cancer in Patients with Benign Prostatic Hyperplasia: A Pooled Analysis of 15Real-world Databases
Dae Yul YANG ; Won-Woo SEO ; Rae Woong PARK ; Sang Youl RHEE ; Jae Myung CHA ; Yoon Soo HAH ; Chang Won JEONG ; Kyung-Jin KIM ; Hyeon-Jong YANG ; Do Kyung KIM ; Ji Yong HA
The World Journal of Men's Health 2025;43(1):188-196
Purpose:
Finasteride and dutasteride are used to treat benign prostatic hyperplasia (BPH) and reduce the risk of developing prostate cancer. Finasteride blocks only the type 2 form of 5-alpha-reductase, whereas dutasteride blocks both type 1 and 2 forms of the enzyme. Previous studies suggest the possibility that dutasteride may be superior to finasteride in preventing prostate cancer. We directly compared the effects of finasteride and dutasteride on the risk of prostate cancer in patients with BPH using a pooled analysis of 15 real-world databases.
Materials and Methods:
We conducted a multicenter, cohort study of new-users of finasteride and dutasteride. We include patients who were prescribed 5 mg finasteride or dutasteride for the first time to treat BPH and had at least 180 days of prescription. We excluded patients with a history of prostate cancer or a prostate-specific antigen level ≥ 4 ng/mL before the study drug prescription. Cox regression analysis was performed to examine the hazard ratio (HR) for prostate cancer after propensity score (PS) matching.
Results:
A total of 8,284 patients of new-users of finasteride and 8,670 patients of new-users of dutasteride were included across the 15 databases. In the overall population, compared to dutasteride, finasteride was associated with a lower risk of prostate cancer in both on-treatment and intent-to-treat time-at-risk periods. After 1:1 PS matching, 4,897 patients using finasteride and 4,897 patients using dutasteride were enrolled in the present study. No significant differences were observed for risk of prostate cancer between finasteride and dutasteride both on-treatment (HR=0.66, 95% confidence interval [CI]: 0.44–1.00; p=0.051) and intent-to-treat time-at-risk periods (HR=0.87, 95% CI: 0.67–1.14; p=0.310).
Conclusions
Using real-world databases, the present study demonstrated that dutasteride was not associated with a lower risk of prostate cancer than finasteride in patients with BPH.

Result Analysis
Print
Save