1.Real-Time Assessment of Black Carbon Peaks Among Workers Exposed to Diesel Engine Exhaust Emissions
Ju-Hyun PARK ; Sangjun CHOI ; Kyung Ehi ZOH ; Seung Won KIM ; Dong-Hee KOH ; Won KIM ; Dong-Uk PARK
Safety and Health at Work 2026;17(1):142-150
Background:
Workers are commonly exposed to diesel engine exhaust (DEE) from diesel-powered engines and vehicles (DEVs), which contain harmful particulates such as black carbon (BC). This study aimed to characterize the peak BC exposures of workers operating or working near DEVs.
Methods:
BC levels were recorded every minute from workers driving or working near DEVs using a portable aethalometer and were categorized by job type and activity. Peak BC levels were characterized using the occupational exposure limits for DEE (measured as elemental carbon) of 10 μg/m 3 and 50 μg/ m3 as cut-off values.
Results:
Forklift operators, garbage collectors, and machine operators showed peak BC exposure levels surpassing 20 μg/m 3 , with average levels above 10 μg/m 3 . Despite their short exposure durations (<1 hour), these peaks contributed significantly (>60%) to the daily average BC exposure. The daily contribution rate of peak exposures above 10 μg/m 3 to the average daily BC exposure often exceeded 50%. The ratio of peak levels above 10 μg/m 3 and 50 μg/m 3 to the arithmetic mean was negatively correlated with exposure duration, the proportion of exposure duration, and the daily contribution of peak levels.
Conclusion
Drivers of diesel-engine vehicles often experienced significant spikes in BC exposure, highlighting the need for real-time monitoring, which is recommended as a best-practice approach to identify and mitigate short-term peak exposures.
2.A survey of anesthesiologists aged 60 years and older in Korea: current status, challenges, and future strategies
Won Uk KOH ; Shamin Ara SULTANA ; Jong Ho KIM ; So Young LIM ; Sang woo KIM ; Sung Mi HWANG ; Youngsuk KWON ; Jae Jun LEE ; Hong Seuk YANG
Anesthesia and Pain Medicine 2025;20(1):86-97
Background:
As the global population ages, medical professionals are also aging. This study investigates the status of Korean anesthesiologists over the age of 60.
Methods:
Anesthesiologists aged 60 and older, residing and working in Korea, were invited to participate in this study via e-mail from February to March 2021 and by mail from June to August 2021. The survey consisted of 40 questions covering 10 topics, including health status, residence, work style, and economic status. Depending on the type of question, answers were ranked on a scale of 1, 2, and 3, with the most preferred response being selected.
Results:
A total of 63 responses were received, resulting in a response rate of 26.5%. Among the respondents, 56 were currently practicing as anesthesiologists and reported satisfaction with their clinical practice and life status. On average, they treated 24 patients per day without experiencing significant discomfort or inconvenience in their roles as senior physicians. Twenty-four respondents acknowledged physical discomfort related to aging, and nine expressed cautions regarding age-related changes. Fifty-two respondents indicated that reeducation for advanced medical practice as anesthesiologists was necessary.
Conclusions
Senior anesthesiologists in Korea are primarily working in secondary and tertiary hospitals and are satisfied with their current life status. A comprehensive evaluation of reeducation programs for advanced clinical practice and retirement strategies for senior anesthesiologists is needed to address the growing number of aging physicians in the workforce.
3.Feasibility and accuracy of pediatric core temperature measurement using an esophageal probe inserted through the gastric lumen of a second-generation supraglottic airway device: a prospective observational study
Yeon-Ju KIM ; Eundong LEE ; Jaedo LEE ; Hyungtae KIM ; Won Uk KOH ; Young-Jin RO ; Ha-Jung KIM
Anesthesia and Pain Medicine 2024;19(Suppl 1):S105-S112
Background:
Accurate core temperature measurement in children is crucial; however, measuring esophageal temperature (TE) using a supraglottic airway device (SAD) can be challenging. Second-generation SADs, which have a gastric channel, can measure TE, and reduce gastric air volume. This study aimed to compare TE, measured using a probe inserted through the SAD gastric channel, with tympanic membrane (TTM) and forehead (TZHF) temperatures, measured using a zero-heat-flux cutaneous thermometer, with rectal temperature (TR).
Methods:
Temperature was recorded at 10-min intervals from 10 min after probe insertion until completion of surgery. We performed an equivalence test to evaluate whether the TE, TTM, and TZHF were equivalent to TR, with a margin of 0.3°C. Additionally, intraclass correlation coefficients (ICC) were calculated to assess the reliability of TE and TR at each time point.
Results:
We included 41 patients in the final analysis. In all patients, the esophageal probe was successfully inserted through the gastric channel of the SAD. When assessing agreement with TR as a reference, TE demonstrated equivalent results at all time points (P < 0.001 at 0, 10, 20, 30, and 40-min intervals and P = 0.018 at the 50-min interval), except at the completion of surgery (P = 0.697). TE also demonstrated good reliability with TR as a reference throughout the surgery (ICC > 0.75).
Conclusions
In children with SAD insertion, TE can be accurately and feasibly measured through the SAD’s gastric channel, making it suitable for routine application.
4.Feasibility and accuracy of pediatric core temperature measurement using an esophageal probe inserted through the gastric lumen of a second-generation supraglottic airway device: a prospective observational study
Yeon-Ju KIM ; Eundong LEE ; Jaedo LEE ; Hyungtae KIM ; Won Uk KOH ; Young-Jin RO ; Ha-Jung KIM
Anesthesia and Pain Medicine 2024;19(Suppl 1):S105-S112
Background:
Accurate core temperature measurement in children is crucial; however, measuring esophageal temperature (TE) using a supraglottic airway device (SAD) can be challenging. Second-generation SADs, which have a gastric channel, can measure TE, and reduce gastric air volume. This study aimed to compare TE, measured using a probe inserted through the SAD gastric channel, with tympanic membrane (TTM) and forehead (TZHF) temperatures, measured using a zero-heat-flux cutaneous thermometer, with rectal temperature (TR).
Methods:
Temperature was recorded at 10-min intervals from 10 min after probe insertion until completion of surgery. We performed an equivalence test to evaluate whether the TE, TTM, and TZHF were equivalent to TR, with a margin of 0.3°C. Additionally, intraclass correlation coefficients (ICC) were calculated to assess the reliability of TE and TR at each time point.
Results:
We included 41 patients in the final analysis. In all patients, the esophageal probe was successfully inserted through the gastric channel of the SAD. When assessing agreement with TR as a reference, TE demonstrated equivalent results at all time points (P < 0.001 at 0, 10, 20, 30, and 40-min intervals and P = 0.018 at the 50-min interval), except at the completion of surgery (P = 0.697). TE also demonstrated good reliability with TR as a reference throughout the surgery (ICC > 0.75).
Conclusions
In children with SAD insertion, TE can be accurately and feasibly measured through the SAD’s gastric channel, making it suitable for routine application.
5.Feasibility and accuracy of pediatric core temperature measurement using an esophageal probe inserted through the gastric lumen of a second-generation supraglottic airway device: a prospective observational study
Yeon-Ju KIM ; Eundong LEE ; Jaedo LEE ; Hyungtae KIM ; Won Uk KOH ; Young-Jin RO ; Ha-Jung KIM
Anesthesia and Pain Medicine 2024;19(Suppl 1):S105-S112
Background:
Accurate core temperature measurement in children is crucial; however, measuring esophageal temperature (TE) using a supraglottic airway device (SAD) can be challenging. Second-generation SADs, which have a gastric channel, can measure TE, and reduce gastric air volume. This study aimed to compare TE, measured using a probe inserted through the SAD gastric channel, with tympanic membrane (TTM) and forehead (TZHF) temperatures, measured using a zero-heat-flux cutaneous thermometer, with rectal temperature (TR).
Methods:
Temperature was recorded at 10-min intervals from 10 min after probe insertion until completion of surgery. We performed an equivalence test to evaluate whether the TE, TTM, and TZHF were equivalent to TR, with a margin of 0.3°C. Additionally, intraclass correlation coefficients (ICC) were calculated to assess the reliability of TE and TR at each time point.
Results:
We included 41 patients in the final analysis. In all patients, the esophageal probe was successfully inserted through the gastric channel of the SAD. When assessing agreement with TR as a reference, TE demonstrated equivalent results at all time points (P < 0.001 at 0, 10, 20, 30, and 40-min intervals and P = 0.018 at the 50-min interval), except at the completion of surgery (P = 0.697). TE also demonstrated good reliability with TR as a reference throughout the surgery (ICC > 0.75).
Conclusions
In children with SAD insertion, TE can be accurately and feasibly measured through the SAD’s gastric channel, making it suitable for routine application.
6.Evaluating the Validity and Reliability of the Korean Version of the Scales for Outcomes in Parkinson’s Disease–Cognition
Jinse PARK ; Eungseok OH ; Seong-Beom KOH ; In-Uk SONG ; Tae-Beom AHN ; Sang Jin KIM ; Sang-Myung CHEON ; Yoon-Joong KIM ; Jin Whan CHO ; Hyeo-Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong-Min KIM ; Han-Joon KIM ; Young-Hee SUNG ; Do Young KWON ; Jae-Hyeok LEE ; Jee-Young LEE ; Ji Seon KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi-Jung KIM ; Jinyoung YOUN ; Hui-Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum-Yil KWON ; Su-Yun LEE ; Younsoo KIM ; Hee-Tae KIM ; Joong-Seok KIM ; Ji-Young KIM
Journal of Movement Disorders 2024;17(3):328-332
Objective:
The Scales for Outcomes in Parkinson’s Disease–Cognition (SCOPA-Cog) was developed to assess cognition in patients with Parkinson’s disease (PD). In this study, we aimed to evaluate the validity and reliability of the Korean version of the SCOPACog (K-SCOPA-Cog).
Methods:
We enrolled 129 PD patients with movement disorders from 31 clinics in South Korea. The original version of the SCOPA-Cog was translated into Korean using the translation-retranslation method. The test–retest method with an intraclass correlation coefficient (ICC) and Cronbach’s alpha coefficient were used to assess reliability. Spearman’s rank correlation analysis with the Montreal Cognitive Assessment-Korean version (MOCA-K) and the Korean Mini-Mental State Examination (K-MMSE) were used to assess concurrent validity.
Results:
The Cronbach’s alpha coefficient was 0.797, and the ICC was 0.887. Spearman’s rank correlation analysis revealed a significant correlation with the K-MMSE and MOCA-K scores (r = 0.546 and r = 0.683, respectively).
Conclusion
Our results demonstrate that the K-SCOPA-Cog has good reliability and validity.
7.Feasibility and accuracy of pediatric core temperature measurement using an esophageal probe inserted through the gastric lumen of a second-generation supraglottic airway device: a prospective observational study
Yeon-Ju KIM ; Eundong LEE ; Jaedo LEE ; Hyungtae KIM ; Won Uk KOH ; Young-Jin RO ; Ha-Jung KIM
Anesthesia and Pain Medicine 2024;19(Suppl 1):S105-S112
Background:
Accurate core temperature measurement in children is crucial; however, measuring esophageal temperature (TE) using a supraglottic airway device (SAD) can be challenging. Second-generation SADs, which have a gastric channel, can measure TE, and reduce gastric air volume. This study aimed to compare TE, measured using a probe inserted through the SAD gastric channel, with tympanic membrane (TTM) and forehead (TZHF) temperatures, measured using a zero-heat-flux cutaneous thermometer, with rectal temperature (TR).
Methods:
Temperature was recorded at 10-min intervals from 10 min after probe insertion until completion of surgery. We performed an equivalence test to evaluate whether the TE, TTM, and TZHF were equivalent to TR, with a margin of 0.3°C. Additionally, intraclass correlation coefficients (ICC) were calculated to assess the reliability of TE and TR at each time point.
Results:
We included 41 patients in the final analysis. In all patients, the esophageal probe was successfully inserted through the gastric channel of the SAD. When assessing agreement with TR as a reference, TE demonstrated equivalent results at all time points (P < 0.001 at 0, 10, 20, 30, and 40-min intervals and P = 0.018 at the 50-min interval), except at the completion of surgery (P = 0.697). TE also demonstrated good reliability with TR as a reference throughout the surgery (ICC > 0.75).
Conclusions
In children with SAD insertion, TE can be accurately and feasibly measured through the SAD’s gastric channel, making it suitable for routine application.
8.Feasibility and accuracy of pediatric core temperature measurement using an esophageal probe inserted through the gastric lumen of a second-generation supraglottic airway device: a prospective observational study
Yeon-Ju KIM ; Eundong LEE ; Jaedo LEE ; Hyungtae KIM ; Won Uk KOH ; Young-Jin RO ; Ha-Jung KIM
Anesthesia and Pain Medicine 2024;19(Suppl 1):S105-S112
Background:
Accurate core temperature measurement in children is crucial; however, measuring esophageal temperature (TE) using a supraglottic airway device (SAD) can be challenging. Second-generation SADs, which have a gastric channel, can measure TE, and reduce gastric air volume. This study aimed to compare TE, measured using a probe inserted through the SAD gastric channel, with tympanic membrane (TTM) and forehead (TZHF) temperatures, measured using a zero-heat-flux cutaneous thermometer, with rectal temperature (TR).
Methods:
Temperature was recorded at 10-min intervals from 10 min after probe insertion until completion of surgery. We performed an equivalence test to evaluate whether the TE, TTM, and TZHF were equivalent to TR, with a margin of 0.3°C. Additionally, intraclass correlation coefficients (ICC) were calculated to assess the reliability of TE and TR at each time point.
Results:
We included 41 patients in the final analysis. In all patients, the esophageal probe was successfully inserted through the gastric channel of the SAD. When assessing agreement with TR as a reference, TE demonstrated equivalent results at all time points (P < 0.001 at 0, 10, 20, 30, and 40-min intervals and P = 0.018 at the 50-min interval), except at the completion of surgery (P = 0.697). TE also demonstrated good reliability with TR as a reference throughout the surgery (ICC > 0.75).
Conclusions
In children with SAD insertion, TE can be accurately and feasibly measured through the SAD’s gastric channel, making it suitable for routine application.
9.Comparison of preemptive and preventive intravenous acetaminophen on opioid consumption in pediatrics undergoing posterior spinal fusion surgery: a randomized controlled trial
Yeon Ju KIM ; Ha-Jung KIM ; Sehee KIM ; Hyungtae KIM ; Choon Sung LEE ; Chang Ju HWANG ; Jae Hwan CHO ; Young-Jin RO ; Won Uk KOH
Korean Journal of Anesthesiology 2024;77(3):326-334
Background:
Posterior spinal fusion (PSF), commonly used for adolescent idiopathic scoliosis (AIS), causes severe postoperative pain. Intravenous (IV) administration of acetaminophen has shown promise for opioid-sparing analgesia; however, its analgesic effect and optimal timing for its standard use remain unclear. Our study aimed to evaluate the analgesic effect and optimal timing of IV acetaminophen administration in pediatric and adolescent patients undergoing PSF and requiring adequate pain control.
Methods:
This prospective, randomized, triple-blind trial was conducted in patients aged 11–20 undergoing PSF. Participants were randomized into three groups: the preemptive group (received IV acetaminophen 15 mg/kg after anesthetic induction/before surgical incision), the preventive group (received IV acetaminophen 15 mg/kg at the end of surgery/before skin closure), and the placebo group. The primary outcome was cumulative opioid consumption during the first 24 h postoperatively.
Results:
Among the 99 enrolled patients, the mean ± standard deviation (SD) amount of opioid consumption during the postoperative 24 h was 60.66 ± 23.84, 52.23 ± 22.43, and 66.70 ± 23.01 mg in the preemptive, preventive, and placebo groups, respectively (overall P = 0.043). A post hoc analysis revealed that the preventive group had significantly lower opioid consumption than the placebo group (P = 0.013). However, no significant differences between the groups were observed for the secondary outcomes.
Conclusions
The preventive administration of scheduled IV acetaminophen reduces cumulative opioid consumption without increasing the incidence of drug-induced adverse events in pediatric and adolescent patients undergoing PSF.
10.Evaluation of Temporal Trends of Lead Exposure in Korean Workers Using Workplace Monitoring Data
Dong-Hee KOH ; Sangjun CHOI ; Ju-Hyun PARK ; Sang-Gil LEE ; Hwan-Cheol KIM ; Inah KIM ; Jong-Uk WON ; Dae Sung LIM ; Hoekyeong SEO ; Dong-Uk PARK
Journal of Korean Medical Science 2023;38(34):e271-
Background:
Lead, which is widely used in various industrial settings, is a major health hazard for manufacturing workers. Therefore, control of lead exposure has been implemented in an effort to prevent lead-related health problems. In this study, our aim was to evaluate temporal trends in occupational lead exposure in Korean lead workers using data from monitoring of workplace exposure.
Methods:
A nationwide work environment monitoring database, data from a work environment monitoring institution, and data extracted from a review paper were utilized. Different versions of standard industrial classification codes were aligned with the 10th Korean Standard Industrial Classification, which is generally consistent with the 4th revision of the International Standard Industrial Classification. The multiple data sources were combined and temporal trends over the period from 1994–2021 were estimated. In addition, separate estimation of temporal trends in the storage battery manufacturing industry over the period from 1987–2021 was also performed.
Results:
A total of 444,296 personal airborne lead measurements were used for the estimation process. The temporal trends in occupational exposure to lead declined by −6% annually over the study period. In particular, levels of lead exposure in the storage battery manufacturing industry showed a steeper decline of −12% annually.
Conclusions
Findings of our study showed that occupational exposure to lead declined over the period from 1994 to 2021 in Korea. However, adverse effects of exposure to lead on health should be regarded with caution. The results will be useful in conduct of epidemiological studies examining lead-related effects on health.

Result Analysis
Print
Save
E-mail