1.Testing the reliability and validity of the Korean version of the Pittsburgh Sleep Quality Index using Fitbit devices: a cross-sectional analysis
Si-Yeon LEE ; Ja-Eun CHOI ; Ji-Won LEE ; Yaeji LEE ; Jae-Min PARK ; Kyung-Won HONG
Korean Journal of Family Medicine 2025;46(1):42-47
Background:
Sleep disorders and insomnia are prevalent worldwide, with negative health outcomes. The Pittsburgh Sleep Quality Index (PSQI) is a widely used self-report assessment tool for evaluating sleep quality, comprising seven subdomains. The Korean version of the PSQI (PSQI-K) has been tested for reliability and validity in small sample sizes but lacks large-scale validation using objective measures.
Methods:
This study was conducted with 268 Korean adults attending health check programs. Participants completed the PSQI-K questionnaire and wore Fitbit devices (Fitbit Inc., USA) to ascertain sleep parameters. Reliability was analyzed using the Cronbach’s α coefficient, and construct validity was determined through factor analysis. Criteria validity was assessed by correlating their index scores with Fitbit sleep parameters. We identified the optimal cutoff for detecting sleep disorders.
Results:
The Cronbach’s α coefficient was 0.61, indicating adequate internal consistency. Factor analysis revealed three factors, explaining 48.2% of sleep quality variance. The index scores were negatively correlated with Fitbit sleep efficiency, total sleep time, and number of awakenings (P<0.05). The optimal cutoff point for identifying sleep disorder groups was ≥6.
Conclusion
The PSQI-K demonstrated good reliability and validity when correlated with Fitbit sleep parameters, offering a practical screening tool for identifying sleep disorders among Korean adults. Cutoff scores can help identify patients for sleep interventions. However, further large-scale studies are required to validate these findings.
2.Testing the reliability and validity of the Korean version of the Pittsburgh Sleep Quality Index using Fitbit devices: a cross-sectional analysis
Si-Yeon LEE ; Ja-Eun CHOI ; Ji-Won LEE ; Yaeji LEE ; Jae-Min PARK ; Kyung-Won HONG
Korean Journal of Family Medicine 2025;46(1):42-47
Background:
Sleep disorders and insomnia are prevalent worldwide, with negative health outcomes. The Pittsburgh Sleep Quality Index (PSQI) is a widely used self-report assessment tool for evaluating sleep quality, comprising seven subdomains. The Korean version of the PSQI (PSQI-K) has been tested for reliability and validity in small sample sizes but lacks large-scale validation using objective measures.
Methods:
This study was conducted with 268 Korean adults attending health check programs. Participants completed the PSQI-K questionnaire and wore Fitbit devices (Fitbit Inc., USA) to ascertain sleep parameters. Reliability was analyzed using the Cronbach’s α coefficient, and construct validity was determined through factor analysis. Criteria validity was assessed by correlating their index scores with Fitbit sleep parameters. We identified the optimal cutoff for detecting sleep disorders.
Results:
The Cronbach’s α coefficient was 0.61, indicating adequate internal consistency. Factor analysis revealed three factors, explaining 48.2% of sleep quality variance. The index scores were negatively correlated with Fitbit sleep efficiency, total sleep time, and number of awakenings (P<0.05). The optimal cutoff point for identifying sleep disorder groups was ≥6.
Conclusion
The PSQI-K demonstrated good reliability and validity when correlated with Fitbit sleep parameters, offering a practical screening tool for identifying sleep disorders among Korean adults. Cutoff scores can help identify patients for sleep interventions. However, further large-scale studies are required to validate these findings.
3.Testing the reliability and validity of the Korean version of the Pittsburgh Sleep Quality Index using Fitbit devices: a cross-sectional analysis
Si-Yeon LEE ; Ja-Eun CHOI ; Ji-Won LEE ; Yaeji LEE ; Jae-Min PARK ; Kyung-Won HONG
Korean Journal of Family Medicine 2025;46(1):42-47
Background:
Sleep disorders and insomnia are prevalent worldwide, with negative health outcomes. The Pittsburgh Sleep Quality Index (PSQI) is a widely used self-report assessment tool for evaluating sleep quality, comprising seven subdomains. The Korean version of the PSQI (PSQI-K) has been tested for reliability and validity in small sample sizes but lacks large-scale validation using objective measures.
Methods:
This study was conducted with 268 Korean adults attending health check programs. Participants completed the PSQI-K questionnaire and wore Fitbit devices (Fitbit Inc., USA) to ascertain sleep parameters. Reliability was analyzed using the Cronbach’s α coefficient, and construct validity was determined through factor analysis. Criteria validity was assessed by correlating their index scores with Fitbit sleep parameters. We identified the optimal cutoff for detecting sleep disorders.
Results:
The Cronbach’s α coefficient was 0.61, indicating adequate internal consistency. Factor analysis revealed three factors, explaining 48.2% of sleep quality variance. The index scores were negatively correlated with Fitbit sleep efficiency, total sleep time, and number of awakenings (P<0.05). The optimal cutoff point for identifying sleep disorder groups was ≥6.
Conclusion
The PSQI-K demonstrated good reliability and validity when correlated with Fitbit sleep parameters, offering a practical screening tool for identifying sleep disorders among Korean adults. Cutoff scores can help identify patients for sleep interventions. However, further large-scale studies are required to validate these findings.
4.Testing the reliability and validity of the Korean version of the Pittsburgh Sleep Quality Index using Fitbit devices: a cross-sectional analysis
Si-Yeon LEE ; Ja-Eun CHOI ; Ji-Won LEE ; Yaeji LEE ; Jae-Min PARK ; Kyung-Won HONG
Korean Journal of Family Medicine 2025;46(1):42-47
Background:
Sleep disorders and insomnia are prevalent worldwide, with negative health outcomes. The Pittsburgh Sleep Quality Index (PSQI) is a widely used self-report assessment tool for evaluating sleep quality, comprising seven subdomains. The Korean version of the PSQI (PSQI-K) has been tested for reliability and validity in small sample sizes but lacks large-scale validation using objective measures.
Methods:
This study was conducted with 268 Korean adults attending health check programs. Participants completed the PSQI-K questionnaire and wore Fitbit devices (Fitbit Inc., USA) to ascertain sleep parameters. Reliability was analyzed using the Cronbach’s α coefficient, and construct validity was determined through factor analysis. Criteria validity was assessed by correlating their index scores with Fitbit sleep parameters. We identified the optimal cutoff for detecting sleep disorders.
Results:
The Cronbach’s α coefficient was 0.61, indicating adequate internal consistency. Factor analysis revealed three factors, explaining 48.2% of sleep quality variance. The index scores were negatively correlated with Fitbit sleep efficiency, total sleep time, and number of awakenings (P<0.05). The optimal cutoff point for identifying sleep disorder groups was ≥6.
Conclusion
The PSQI-K demonstrated good reliability and validity when correlated with Fitbit sleep parameters, offering a practical screening tool for identifying sleep disorders among Korean adults. Cutoff scores can help identify patients for sleep interventions. However, further large-scale studies are required to validate these findings.
5.Outcomes of bilateral axillo-breast approach robotic parathyroidectomy versus open parathyroidectomy for primary hyperparathyroidism: a single-institution retrospective study
Jae Bong CHOI ; Jee-Hye CHOI ; Yoon KONG ; Ja Kyung LEE ; Woochul KIM ; Hyeong Won YU ; Su-jin KIM ; Young Jun CHAI ; June Young CHOI ; Kyu Eun LEE
Annals of Surgical Treatment and Research 2024;106(4):203-210
Purpose:
Bilateral axillo-breast approach robotic parathyroidectomy (BABA-RP) aims to remove overactive or enlarged parathyroid glands with no visible neck collar incision. In this study, we compared the safety and surgical outcomes of BABA-RP vs. those of an open surgery group to ascertain whether BABA-RP is a safe and feasible surgical approach for patients with primary hyperparathyroidism (pHPT).
Methods:
This single-institution retrospective cohort study included 74 patients with primary HPT who underwent open parathyroidectomy (n = 37) or BABA-RP (n = 37) at our institution between November 2014 and March 2023. Patient demographics, biochemical cure rates, operative time, blood loss rates, and complication rates were examined and compared.
Results:
The patients in the BABA-RP group were younger and had a longer mean operative time. Regarding complication events, 2 patients in the open surgery group and 1 patient in the BABA-RP group had transient hypoparathyroidism. All 74 patients achieved biochemical cure at <6 months, regardless of the approach used. Two patients in the BABA-RP group and 1 patient in the open surgery group had carcinoma on surgical pathology. All 3 patients with parathyroid carcinoma remained recurrence-free at 1-year follow-up.
Conclusion
Compared with the open procedure, BABA-RP is a safe and feasible procedure that provides an excellent biochemical cure rate for patients with pHPT and has superior cosmetic benefits with equivalent surgical outcomes.
6.Effect of thyroid-stimulating hormone suppression on quality of life in thyroid lobectomy patients: interim analysis of a multicenter, randomized controlled trial in low- to intermediate-risk thyroid cancer patients (MASTER study)
Ja Kyung LEE ; Eu Jeong KU ; Su-jin KIM ; Woochul KIM ; Jae Won CHO ; Kyong Yeun JUNG ; Hyeong Won YU ; Yea Eun KANG ; Mijin KIM ; Hee Kyung KIM ; Junsun RYU ; June Young CHOI ;
Annals of Surgical Treatment and Research 2024;106(1):19-30
Purpose:
Current clinical practices favor less or no thyroid-stimulating hormone (TSH) suppression for low- to intermediate-risk thyroid cancer patients who receive thyroid lobectomy. The association of TSH suppression on healthrelated quality of life (HR-QoL) in patients after thyroid lobectomy is not well studied. This study aimed to evaluate the effect of TSH suppression on patient HR-QoL after thyroid lobectomy.
Methods:
This study included patients enrolled in an ongoing, multicenter, randomized controlled study investigating the effects of TSH suppression. Patients were randomized to either the low-TSH group (TSH target range, 0.3–1.99 μIU/ mL) or the high-TSH group (TSH target range, 2.0–7.99 μIU/mL). The HR-QoL, hyperthyroidism symptom, and depression symptom questionnaires performed preoperatively and 2 weeks and 3 months postoperatively were evaluated.
Results:
Total of 669 patients (low-TSH group, 340; high-TSH group, 329) were included. Although total HR-QoL score changes were not different between the 2 groups, the high-TSH group had a significantly higher score in the physical domain at postoperative 3 months (P = 0.046). The 2 groups did not have significant differences in hyperthyroidism and depression scores.
Conclusion
In the short-term postoperative period, the physical HR-QoL scores in thyroid lobectomy patients were better when they did not receive TSH suppression. This study suggests the importance of considering HR-QoL when setting TSH suppression targets in thyroid lobectomy patients.
7.Anti-inflammatory Activity and Modulation of Endoplasmic Reticulum Stress by the Hexane Fraction from the Roots of Peucedanum insolens Kitag
Jin-Ik KIM ; Yong-Won CHOI ; Nandintsetseg NARANTUYA ; In-Young LEE ; Ji-An KANG ; Sik-Jae CHO ; Ja-Young MOON
Natural Product Sciences 2024;30(3):167-174
In this study, the anti-inflammatory activity and ER stress modulation of the hexane fraction from Peucedanum insolens Kitag. root was investigated. The anti-inflammatory activity was evaluated by measuring nitric oxide inhibition and analyzing iNOS and COX-2 expression in LPS-treated RAW 264.7 macrophages using Western blot. The hexane fraction’s effect on ER stress was assessed by monitoring ATF6α transcriptional activity in the stable recombinant HLR-GV-hATF6α (333) cell line. Additionally, the expression levels of ER stress-related proteins, including eIF2α, p-eIF2α, GRP78, and CHOP, were analyzed by western blot in HeLa cells. Our results demonstrated that the hexane fraction strongly inhibited nitric oxide production and the expression of iNOS and COX-2 in LPS-treated RAW 264.7 cells. It also significantly reduced ATF6α transcriptional activation induced by thapsigargin or tunicamycin. In HeLa cells, the hexane fraction inhibited the expression of ER stress-related proteins GRP78 and CHOP induced by thapsigargin. Although the hexane fraction alone did not affect GRP78, CHOP and eIF2α levels, it enhanced eIF2α phosphorylation in a concentrationdependent manner. Co-treatment with the hexane extract and thapsigargin prevented both CHOP and GRP78 expressions and eIF2α phosphorylation. Taken together, our results suggest that the anti-inflammatory potency of the hexane-fraction of P. insolens might be related to its potential to modulate ER stress. To find out more detailed integrated actions of the hexanefraction of P. insolens against ER stress-induced inflammation signalling and to identify bioactive compound(s) associated with ERSR-related inflammation, further studies are required using a single cell type, such as RAW 264.7 or HeLa cells.
8.Comparison between Nivolumab and Regorafenib as Second-line Systemic Therapies after Sorafenib Failure in Patients with Hepatocellular Carcinoma
Hong Jun LEE ; Jae Seung LEE ; Hyesung SO ; Ja Kyung YOON ; Jin-Young CHOI ; Hye Won LEE ; Beom Kyung KIM ; Seung Up KIM ; Jun Yong PARK ; Sang Hoon AHN ; Do Young KIM
Yonsei Medical Journal 2024;65(7):371-379
Purpose:
Nivolumab and regorafenib are second-line therapies for patients with advanced hepatocellular carcinoma (HCC). We aimed to compare the effectiveness of nivolumab and regorafenib.
Materials and Methods:
We retrospectively reviewed patients with HCC treated with nivolumab or regorafenib after sorafenib failure. Progression-free survival (PFS) and overall survival (OS) were analyzed. An inverse probability of treatment weighting using the propensity score (PS) was performed to reduce treatment selection bias.
Results:
Among the 189 patients recruited, 137 and 52 patients received regorafenib and nivolumab after sorafenib failure, respectively. Nivolumab users showed higher Child-Pugh B patients (42.3% vs. 24.1%) and shorter median sorafenib maintenance (2.2 months vs. 3.5 months) compared to regorafenib users. Nivolumab users showed shorter median OS (4.2 months vs. 7.4 months, p=0.045) than regorafenib users and similar median PFS (1.8 months vs. 2.7 months, p=0.070). However, the median overall and PFS did not differ between the two treatment groups after the 1:1 PS matching (log-rank p=0.810 and 0.810, respectively) and after the stabilized inverse probability of treatment weighting (log-rank p=0.445 and 0.878, respectively). In addition, covariate-adjusted Cox regression analyses showed that overall and PFS did not significantly differ between nivolumab and regorafenib users after 1:1 PS matching and stabilized inverse probability of treatment weighting (all p>0.05).
Conclusion
Clinical outcomes of patients treated with nivolumab and regorafenib after sorafenib treatment failure did not differ significantly.
9.Efficacy and safety of losartan in childhood immunoglobulin A nephropathy: a prospective multicenter study
Hyesun HYUN ; Yo Han AHN ; Eujin PARK ; Hyun Jin CHOI ; Kyoung Hee HAN ; Jung Won LEE ; Su Young KIM ; Eun Mi YANG ; Jin Soon SUH ; Jae Il SHIN ; Min Hyun CHO ; Ja Wook KOO ; Kee Hyuck KIM ; Hye Won PARK ; Il Soo HA ; Hae Il CHEONG ; Hee Gyung KANG ; Seong Heon KIM
Childhood Kidney Diseases 2023;27(2):97-104
Purpose:
Angiotensin-converting enzyme inhibitors and angiotensin II receptor blockers (ARBs) are frequently employed to counteract the detrimental effects of proteinuria on glomerular diseases. However, the effects of ARBs remain poorly examined in pediatric patients with immunoglobulin A (IgA) nephropathy. Herein, we evaluated the efficacy and safety of losartan, an ARB, in pediatric IgA nephropathy with proteinuria.
Methods:
This prospective, single-arm, multicenter study included children with IgA nephropathy exhibiting proteinuria. Changes in proteinuria, blood pressure, and kidney function were prospectively evaluated before and 4 and 24 weeks after losartan administration. The primary endpoint was the difference in proteinuria between baseline and 24 weeks.
Results:
In total, 29 patients were enrolled and received losartan treatment. The full analysis set included 28 patients who received losartan at least once and had pre- and post-urinary protein to creatinine ratio measurements (n=28). The per-protocol analysis group included 22 patients who completed all scheduled visits without any serious violations during the study period. In both groups, the mean log (urine protein to creatinine ratio) value decreased significantly at 6 months. After 24 weeks, the urinary protein to creatinine ratio decreased by more than 50% in approximately 40% of the patients. The glomerular filtration rate was not significantly altered during the observation period.
Conclusions
Losartan decreased proteinuria without decreasing kidney function in patients with IgA nephropathy over 24 weeks. Losartan could be safely employed to reduce proteinuria in this patient population. ClinicalTrials.gov trial registration (NCT0223277)

Result Analysis
Print
Save
E-mail