1.Comparative efficacy of O-arm navigation-assisted and conventional posterior cervical expansive open-door laminoplasty via the intermuscular approach in the treatment of cervical spinal cord injury without fracture-dislocation
Zhe SHAO ; Wentao JIANG ; Kai SU ; Rundong GUO ; Long WANG ; Yili LI ; Xiaoteng LI ; Qiangqiang PAN ; Wei MEI ; Qingde WANG
Chinese Journal of Trauma 2025;41(3):259-266
Objective:To compare the efficacy of O-arm navigation-assisted and conventional posterior cervical expansive open-door laminoplasty (CEOL) via the intermuscular approach in the treatment of cervical spinal cord injury without fracture-dislocation (CSCIWFD).Methods:A prospective cohort study was conducted to analyze the clinical data of 60 CSCIWFD patients who were admitted to Zhengzhou Orthopedic Hospital from May 2021 to May 2023, with compression at C3-C6. Patients were randomly divided into two groups: 30 patients underwent O-arm navigation-assisted intermuscular approach CEOL (navigation-assisted group) and 30 patients underwent conventional intermuscular approach CEOL (conventional surgery group). Surgical duration, intraoperative blood loss, postoperative drainage volume, and total surgical blood loss were compared between the two groups. At 2 weeks postoperatively, CT scan was performed to evaluate the accuracy of hinge or open-door position preparation of the surgical segments. Visual analogue scale (VAS) for neck and shoulder pain and Japanese Orthopedic Association (JOA) scores were compared between the two groups preoperatively, at 2 weeks, 6 months postoperatively, and at the last follow-up. Complication rates were also evaluated.Results:A total of 60 patients with CSCIWFD were included, comprising 35 males and 25 females, aged 35-77 years [(50.9±8.6)years]. All the patients were followed up for 12-24 months [(16.9±3.1)months]. The surgical duration and intraoperative blood loss were (121.6±17.9)minutes and (144.7±44.2)ml in the navigation-assisted group, shorter or less than (132.3±14.6)minutes and (178.7±48.7)ml in the conventional surgery group ( P<0.05). There were no statistically significant differences in postoperative drainage volume and total surgical blood loss between the two groups ( P>0.05). CT scan reviewed at 2 weeks postoperatively revealed that the accuracy rate of hinge and open-door position preparation of the surgical segments in the navigation-assisted group was 99.2% (119/120), significantly higher than 86.7% (104/120) in the conventional surgery group ( P<0.01). Before operation and at 2 weeks, 6 months postoperatively, and at the last follow-up, the VAS scores for neck and shoulder pain and JOA scores in the navigation-assisted group were 5.0(4.0, 7.0)points and (8.7±2.8)points, 3.0(2.0, 4.0)points and (10.2±2.5)points, 2.0(1.0, 2.0)points and (1 3.0±1.8)points, and 1.0(1.0, 2.0)points and (13.9±1.5)points respectively, while in the conventional surgery group, the VAS scores and JOA scores were 5.5(5.0, 6.3)points and (8.8±2.6)points, 4.0(3.0, 4.0)points and (10.4±2.5)points, 2.0(1.0, 3.0)points and (12.9±2.2)points, and 2.0(1.0, 2.0)points and (13.8±2.0)points ( P>0.05). Both groups showed improvement in neck and shoulder VAS scores and JOA scores at 2 weeks, 6 months postoperatively, and at the last follow-up, compared to preoperative scores ( P<0.05); further improvement was observed at 6 months postoperatively and at the last follow-up compared to that at 2 weeks postoperatively ( P<0.05). There were no significant differences between neck and shoulder VAS scores or JOA scores at 6 months postoperatively and at the last follow-up ( P>0.05). In the navigation-assisted group, 2 patients had axial neck-shoulder pain postoperatively, with a complication rate of 7% (2/30); while in the conventional surgery group, 7 patients had axial neck-shoulder pain and one patient developed cerebrospinal fluid leakage and low-pressure headache, with a complication rate of 27% (8/30) ( P<0.05). Conclusion:Compared to the conventional intermuscular approach, O-arm navigation-assisted intermuscular approach CEOL for CSCIWFD reduces surgical duration and intraoperative blood loss, improves the accuracy of hinge and open-door position preparation, and lowers complication rates.
2.The Construction of Disease-Specific Reference Models and the Impact on Health Decision-Making
Jie PAN ; Wentao ZHU ; Haijing GUAN
Chinese Health Economics 2025;44(3):9-14
As a tool for evaluating the value of drugs,Economic Evaluation(EE)models are playing an increasingly important role in healthcare and reimbursement decision-making in China.However,the lack of transparency and the uncertainty surrounding the results of these EE models have significantly hindered the translation of research evidence into policy decisions.Constructing a disease reference model provides a critical approach to address these challenges.First,starting from the concept of disease reference model,it compares its differences with traditional economics evaluation models and analyzes the key steps involved in their construc-tion;secondly,it takes advanced lung cancer,diabetes mellitus,and osteoporosis as typical cases to illustrate the main features and the current development of disease reference models;and it finally analyzes the advantages and challenges of the development of disease reference models in China.By systematically reviewing the methods and applications of disease reference models,it con-tributes to the exploration of future directions for economic evaluation models and promotes the high-quality development and deci-sion-making translation of pharmacoeconomics in China.
3.Analysis of the therapeutic effect of asymmetric T 1 pedicle osteotomy in the treatment of stiff cervical thoracic lateral kyphosis deformity
Zhenhui ZHANG ; Qiangqiang PAN ; Long WANG ; Wentao JIANG ; Kai SU ; Peilin LIU ; Wei MEI ; Qingde WANG
Chinese Journal of Surgery 2025;63(5):406-412
Objective:To analyze the clinical efficacy of asymmetric T 1 transpedicular wedge resection Smith-Petersen osteotomy (T 1 SPO) in the treatment of stiff cervical thoracic lateral kyphosis deformity. Methods:This is a retrospective case series study. The clinical data of nine patients with stiff cervical thoracic kyphosis who underwent asymmetric T 1 SPO corrective treatment from June 2012 to October 2022 were collected. There were 7 males and 2 females, aged 45 to 68 years. The surgery time, intraoperative blood loss, and complications were recorded. The chin brow vertical angle (CBVA), cervical thoracic kyphosis Cobb angle, cervical thoracic scoliosis Cobb angle, and cervical thoracic sagittal axis (C 2-T 1 sagittal vertical axis, SVA) before surgery, after surgery, and at the last follow-up were measured and the correction rates were calculate. Results:All 9 patients successfully completed the surgery. The operation time ranged from 245 to 320 minutes, and the intraoperative blood loss was 1 400 to 2 200 ml. All patients were followed up for 24 to 48 months. The preoperative CBVA was 93.7° to 112.0°, which improved to 25.2° to 31.7° at the last follow-up, with an correction rate of 73.4%. The preoperative cervicothoracic kyphosis Cobb angle was -57.0° to -16.6°, which improved to 10.3° to 18.5° at the last follow-up, with an correction rate of 166.7%. The preoperative scoliosis Cobb angle was 13.0° to 16.5°, which improved to 2.2° to 3.8° at the last follow-up, with an correction rate of 84.9%. The preoperative SVA was 7.8 to 12.5 cm, which improved to 4.5 to 6.8 cm at the last follow-up, with an correction rate of 42.3%. One patient experienced numbness and weakness in the left hand after surgery, which recovered after 3 months. One patient had poor healing of the surgical incision, which healed after symptomatic treatment. During the follow-up, the coronal and sagittal balance of all patients was maintained, and no other neurological complications occurred. There were no cases of screw loosening, broken screws, or broken rods, or other internal fixation failures.Conclusion:The application of asymmetric T 1 SPO technique in the treatment of stiff cervical thoracic lateral kyphosis deformity can achieve relatively satisfactory correction effects.
4.The Construction of Disease-Specific Reference Models and the Impact on Health Decision-Making
Jie PAN ; Wentao ZHU ; Haijing GUAN
Chinese Health Economics 2025;44(3):9-14
As a tool for evaluating the value of drugs,Economic Evaluation(EE)models are playing an increasingly important role in healthcare and reimbursement decision-making in China.However,the lack of transparency and the uncertainty surrounding the results of these EE models have significantly hindered the translation of research evidence into policy decisions.Constructing a disease reference model provides a critical approach to address these challenges.First,starting from the concept of disease reference model,it compares its differences with traditional economics evaluation models and analyzes the key steps involved in their construc-tion;secondly,it takes advanced lung cancer,diabetes mellitus,and osteoporosis as typical cases to illustrate the main features and the current development of disease reference models;and it finally analyzes the advantages and challenges of the development of disease reference models in China.By systematically reviewing the methods and applications of disease reference models,it con-tributes to the exploration of future directions for economic evaluation models and promotes the high-quality development and deci-sion-making translation of pharmacoeconomics in China.
5.Preparation and performance evaluation of large diameter artificial vessels modified with polydopamine/gelatin/earthworm active protein
Xin FENG ; Xinyu PAN ; Xuewei ZHANG ; Xiao LIU ; Ziwei ZHAO ; Yicheng LI ; Tuo YANG ; Wentao LI ; Liang ZHAO ; Wenbin LI
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(5):284-294
Objective:To investigate a novel coating technology for artificial blood vessel pipelines, conducting preliminary tests on the mechanical stability, hemocompatibility, and biocompatibility of the coating.Methods:The polyester braided artificial blood vessels produced by Terumo Corporation were subjected to three different experimental treatments and divided into three groups. Model group: The uncoated artificial blood vessels were thoroughly cleaned and freeze-dried. Experimental group: The artificial blood vessels were first immersed in a dopamine solution to form a polydopamine(PDA) coating on their surface, and then further immersed in an earthworm active protein/gelatin(EWAP/GT) solution to create PDA/GT/EWAP-modified artificial blood vessels. Collagen group: The untreated polyester woven artificial blood vessels served as the control. The study detailed the characterization, porosity, water permeability, degradation rate, blood compatibility, and cytotoxicity of the PDA/GT/EWAP-coated artificial blood vessels. Additionally, a 2-week in vivo study was conducted to evaluate the biocompatibility of the PDA/GT/EWAP-coated artificial blood vessels implanted subcutaneously in SD rats.Results:The PDA/GT/EWAP-coated artificial vascular grafts were successfully fabricated. The artificial blood vessels in the PDA/GT/EWAP group exhibited a porosityof(50.53±1.10)%, with water permeability showing a gradual decreasing trend over time. The overall in vitro degradation rate at 4 weeks was(1.83±0.08)%, and the PDA/GT/EWAP group demonstrated favorable mechanical stability. The activated partial thromboplastin time(APTT) of the PDA/GT/EWAP group was(26.30±0.46)s, the thrombin time(TT) was(18.83±0.49)s, the hemolysis rate was(2.15±0.09)%, and the plasma recalcification time(PRT) was(191.00±10.54)s, indicating excellent blood compatibility and anticoagulant properties. MTT assay evaluation of the PDA/GT/EWAP group revealed no significant cytotoxicity. After subcutaneous implantation of vascular samples in rats for 2 weeks, analysis of blood immune parameters and hematoxylin-eosin(HE) staining of the artificial vascular samples showed that the immune response in the PDA/GT/EWAP group exhibited no significant difference compared to the collagen group and was superior to the model group. Conclusion.Conclusion:The PDA/GT/EWAP composite-coated artificial blood vessel demonstrates excellent mechanical properties, good hemocompatibility, biocompatibility, and low cytotoxicity. It also shows remarkable stability. This research offers a new approach for domestic technological breakthroughs in related fields.
6.Comparative efficacy of O-arm navigation-assisted and conventional posterior cervical expansive open-door laminoplasty via the intermuscular approach in the treatment of cervical spinal cord injury without fracture-dislocation
Zhe SHAO ; Wentao JIANG ; Kai SU ; Rundong GUO ; Long WANG ; Yili LI ; Xiaoteng LI ; Qiangqiang PAN ; Wei MEI ; Qingde WANG
Chinese Journal of Trauma 2025;41(3):259-266
Objective:To compare the efficacy of O-arm navigation-assisted and conventional posterior cervical expansive open-door laminoplasty (CEOL) via the intermuscular approach in the treatment of cervical spinal cord injury without fracture-dislocation (CSCIWFD).Methods:A prospective cohort study was conducted to analyze the clinical data of 60 CSCIWFD patients who were admitted to Zhengzhou Orthopedic Hospital from May 2021 to May 2023, with compression at C3-C6. Patients were randomly divided into two groups: 30 patients underwent O-arm navigation-assisted intermuscular approach CEOL (navigation-assisted group) and 30 patients underwent conventional intermuscular approach CEOL (conventional surgery group). Surgical duration, intraoperative blood loss, postoperative drainage volume, and total surgical blood loss were compared between the two groups. At 2 weeks postoperatively, CT scan was performed to evaluate the accuracy of hinge or open-door position preparation of the surgical segments. Visual analogue scale (VAS) for neck and shoulder pain and Japanese Orthopedic Association (JOA) scores were compared between the two groups preoperatively, at 2 weeks, 6 months postoperatively, and at the last follow-up. Complication rates were also evaluated.Results:A total of 60 patients with CSCIWFD were included, comprising 35 males and 25 females, aged 35-77 years [(50.9±8.6)years]. All the patients were followed up for 12-24 months [(16.9±3.1)months]. The surgical duration and intraoperative blood loss were (121.6±17.9)minutes and (144.7±44.2)ml in the navigation-assisted group, shorter or less than (132.3±14.6)minutes and (178.7±48.7)ml in the conventional surgery group ( P<0.05). There were no statistically significant differences in postoperative drainage volume and total surgical blood loss between the two groups ( P>0.05). CT scan reviewed at 2 weeks postoperatively revealed that the accuracy rate of hinge and open-door position preparation of the surgical segments in the navigation-assisted group was 99.2% (119/120), significantly higher than 86.7% (104/120) in the conventional surgery group ( P<0.01). Before operation and at 2 weeks, 6 months postoperatively, and at the last follow-up, the VAS scores for neck and shoulder pain and JOA scores in the navigation-assisted group were 5.0(4.0, 7.0)points and (8.7±2.8)points, 3.0(2.0, 4.0)points and (10.2±2.5)points, 2.0(1.0, 2.0)points and (1 3.0±1.8)points, and 1.0(1.0, 2.0)points and (13.9±1.5)points respectively, while in the conventional surgery group, the VAS scores and JOA scores were 5.5(5.0, 6.3)points and (8.8±2.6)points, 4.0(3.0, 4.0)points and (10.4±2.5)points, 2.0(1.0, 3.0)points and (12.9±2.2)points, and 2.0(1.0, 2.0)points and (13.8±2.0)points ( P>0.05). Both groups showed improvement in neck and shoulder VAS scores and JOA scores at 2 weeks, 6 months postoperatively, and at the last follow-up, compared to preoperative scores ( P<0.05); further improvement was observed at 6 months postoperatively and at the last follow-up compared to that at 2 weeks postoperatively ( P<0.05). There were no significant differences between neck and shoulder VAS scores or JOA scores at 6 months postoperatively and at the last follow-up ( P>0.05). In the navigation-assisted group, 2 patients had axial neck-shoulder pain postoperatively, with a complication rate of 7% (2/30); while in the conventional surgery group, 7 patients had axial neck-shoulder pain and one patient developed cerebrospinal fluid leakage and low-pressure headache, with a complication rate of 27% (8/30) ( P<0.05). Conclusion:Compared to the conventional intermuscular approach, O-arm navigation-assisted intermuscular approach CEOL for CSCIWFD reduces surgical duration and intraoperative blood loss, improves the accuracy of hinge and open-door position preparation, and lowers complication rates.
7.Effect of diving decompression on platelets:research progress
Wentao MENG ; Yaping PAN ; Wanwan CAI ; Long QING
Academic Journal of Naval Medical University 2025;46(11):1482-1486
Improper diving decompression can desaturate inert gases to form bubbles in the body and may lead to decompression sickness.In the process of decompression sickness,bubbles can directly or indirectly induce changes in platelet activation and coagulation.These abnormal changes play an important role in the rapid onset and continuous injury of decompression sickness.By systematically reviewing the relevant literatures,this article summarizes the effects of diving decompression on platelets,discusses the advantages and disadvantages of current prevention and treatment strategies,and outlines future research directions on the relationship between diving decompression and platelets.
8.A 30-year review and outlook on esophageal acid and pressure measurement
Yong JIANG ; Wentao FANG ; Zhigang LI ; Wenhu CHEN ; Wenhu PAN ; Yanfang ZHENG ; Hong ZHANG ; Yuchen SU ; Jie ZHANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(06):766-770
The Department of Thoracic Surgery of Shanghai Chest Hospital has performed esophageal function testing for over 30 years, being the only department of its kind in China with this capability. The pressure testing and 24-hour pH/impedance monitoring of the esophagus is of great help to assist in the diagnosis and treatment of benign and malignant esophageal diseases related to it. Thanks to the esophageal function test, in addition to the routine various endoscopic anti-reflux procedures, our hospital has taken the lead in China in recent years to carry out a series of clinical and research work for benign esophageal diseases, such as the development of magnetic ring, double nedoscopic combination and new anti-reflux endoscopic techniques. In recent years, we have carried out high-resolution esophageal manometry and 24-hour pH/impedance monitoring for patients with interstitial pneumonia and pulmonary fibrosis suspected to be caused by gastroesophageal acid reflux. We can better assess the correlation between gastroesophageal reflux and pulmonary fibrosis, and to provide the different clinical treatments and even surgical interventions. The Bravo capsule is used more often in the United States, and it has obvious advantages over traditional approach for acid measurement. We strongly call for the collaboration between industry and academic institutions in this field, and the development of our own related products with independent intellectual property rights.
9.Comparative efficacy of O-arm navigation versus C-arm guidance for anterior internal fixation in the management of Anderson-D′Alonzo type II odontoid fractures
Wentao JIANG ; Zhe SHAO ; Kai SU ; Long WANG ; Peilin LIU ; Liangbing GUO ; Qiangqiang PAN ; Qingde WANG
Chinese Journal of Trauma 2025;41(6):557-564
Objective:To compare the efficacy of O-arm navigation versus C-arm guidance for anterior internal fixation in the management of Anderson-D′Alonzo type II odontoid fractures.Methods:A retrospective cohort study was conducted to analyze the clinical data of 58 patients with Anderson-D′Alonzo type II odontoid fractures admitted to Zhengzhou Orthopedic Hospital between January 2017 and September 2024, including 35 males and 23 females, aged 18-57 years [(39.3±9.0)years]. Anderson-D′Alonzo type II fractures were further classified as type IIA in 25 patients and type IIB in 33. Twenty-seven patients underwent O-arm assisted anterior internal fixation (O-arm navigation group), while 31 received C-arm guided anterior internal fixation (C-arm guidance group). The two groups were compared in terms of the operative duration, intraoperative blood loss, success rate for one-time guidewire placement, and intraoperative radiation exposure (anteroposterior and lateral views). At 3 days postoperatively, screw placement accuracy was evaluated via CT in both groups. Additionally, neck disability index (NDI) and visual analogue scale (VAS) scores were assessed preoperatively, at 1 week, 3 months postoperatively, and at the last follow-up. Bone union time and complication rate were also analyzed.Results:All the patients were followed up for 6-20 months [(13.1±3.4)months]. The O-arm navigation group exhibited significantly shorter operative duration [(91.1± 8.9)minutes] and less intraoperative blood loss [(38.9±8.2)ml], compared with (103.3±14.5)minutes and (47.3±9.1)ml in the C-arm guidance group ( P<0.01). The success rate for one-time guidewire placement was 100% (27/27) in the O-arm navigation group, significantly higher than 52% (16/31) in the C-arm guidance group ( P<0.01). Intraoperative radiation exposure for patients in the O-arm navigation group was lower in both anteroposterior view [(11 612.6±1 603.6)μSv] and lateral views [(29 738.2±6 602.5)μSv], compared with (40 638.0±9 431.9)μSv and (47 152.0±11 759.3)μSv in the C-arm guidance group ( P<0.01). CT scans at 3 days postoperatively revealed a 100% (27/27) screw placement accuracy in the O-arm navigation group, compared with 65% (20/31) in the C-arm guidance group ( P<0.01). Before operation, at 1 weeks and 3 months postoperatively, and at the last follow-up, NDI scores were (48.4±7.8)%, (21.0±3.1)%, (14.4±2.4)%, and (13.9±2.3)% in the O-arm navigation group, while they were (47.4±7.6)%, (20.9±3.2)%, (14.1±2.0)%, and (13.8±1.4)% in the C-arm guidance group ( P>0.05); VAS scores were 6.0(6.0, 7.0)points, 4.0(3.0, 4.0)points, 2.0(1.0, 2.0)points, and 2.0(1.0, 2.0)points in the O-arm navigation group, while they were 7.0(6.0, 7.0)points, 4.0(3.0, 5.0)points, 2.0(1.0, 3.0)points, and 2.0(2.0, 2.0)points in the C-arm guidance group ( P>0.05). The NDI and VAS scores in both groups were significantly improved at 1 weeks and 3 months postoperatively, and at the last follow-up compared to those preoperatively ( P<0.05), and were furtherly improved at 3 months postoperatively and at the last follow-up compared to those at 1 weeks postoperatively ( P<0.05), with no significant differences between those at 3 months postoperatively and at the last follow-up ( P>0.05). No significant difference was found in bone union time between the two groups ( P>0.05). The complication rate in the O-arm navigation group was 4% (1/27), lower than 29% (9/31) in the C-arm guidance group ( P<0.05). Conclusions:Compared with C-arm guidance, O-arm assisted anterior internal fixation for Anderson-D′Alonzo type II odontoid fractures can reduce operative duration and intraoperative blood loss, improve the success rate for one-time guidewire placement and screw accuracy, and decrease radiation exposure and complication rate.
10.Comparative efficacy of whole-process visualization system-assisted pedicle screw internal fixation and free-hand pedicle screw internal fixation in the treatment of thoracolumbar burst fracture without neurologic symptoms
Wentao JIANG ; Wei MEI ; Qiangqiang PAN ; Zhe SHAO ; Peilin LIU ; Zhenhui ZHANG ; Kai SU ; Yongsheng KANG ; Qingde WANG
Chinese Journal of Trauma 2025;41(2):157-163
Objective:To compare the efficacy of whole-process visualization system-assisted pedicle screw internal fixation and free-hand pedicle screw internal fixation in the treatment of thoracolumbar burst fracture (TLBF) without neurologic symptoms.Methods:A retrospective cohort study was conducted to analyze the clinical data of 64 patients with TLBF without neurologic symptoms admitted to Zhengzhou Orthopedic Hospital from December 2020 to October 2022, including 41 males and 23 females, aged 23-52 years [(42.1±6.6)years]. The injured vertebrae involved T 11 in 26 patients, T 12 in 17, L 1 in 12, and L 2 in 9. The Wiltse approach was used in all the patients, 31 of whom were treated with pedicle screw internal fixation assisted by the whole-process visualization system (visualization system-assisted screw placement group) and 33 of whom were treated with free-hand pedicle screw internal fixation (free-hand screw placement group). The two groups were compared in terms of operation time, single screw placement time, intraoperative blood loss, intraoperative total radiation dose and total length of hospital stay. The accuracy of pedicle screw placement and penetration rate of the pedicle cortex were evaluated in the two groups. The Cobb angle and lumbar visual analogue scale (VAS) before surgery, at 1 week, 3 months after surgery and at the last follow-up were compared between the two groups. The incidence of postoperative complications was also investigated. Results:All the patients were followed up for 10-33 months [(17.5±4.8)months]. The operation time was (106.9±11.8)minutes in the visualization system-assisted screw placement group, shorter than (121.3±11.4)minutes in the free-hand screw placement group ( P<0.01). The single screw placement time was (9.1±1.0)minutes in the visualization system-assisted screw placement group, shorter than (11.7±1.5)minutes in the free-hand screw placement group ( P<0.01). The total radiation dose was (10.4±2.4)mGy in the visualization system-assisted screw placement group, lower than (51.8±7.2)mGy in the screw placement group ( P<0.01). There was no significant difference in intraoperative blood loss or total length of hospital stay between the two groups ( P>0.05). The accuracy of pedicle screw placement was 96.6% (197/204) in the visualization system-assisted screw placement group, significantly higher than 89.3% (191/214) in the free-hand screw placement group ( P<0.01). Both groups showed significant improvements in Cobb angle and VAS scores at 1 week, 3 months after surgery, and at the last follow-up ( P<0.05). There were no significant differences in Cobb angle or VAS scores between the two groups at each time point ( P>0.05). In the visualization system-assisted screw placement group, one patient had incision infection at 4 days after operation, which was cured with antibiotics. One patient in the free-hand screw placement group developed the symptoms of nerve root irritation at 2 days after surgery, which disappeared at 7 days after revision. There was no significant difference in the incidence of complications between the two groups ( P>0.05). During the follow-up, no patients had broken screws, loosening of internal fixation, or loss of correction in either group. Conclusions:Compared with free-hand pedicle screw internal fixation, the whole-process visualization system-assisted pedicle screw internal fixation in the treatment of TLBF without neurologic symptoms can shorten the time of operation and screw placement, reduce the radiation dose, and improve the accuracy of pedicle screw placement, suggesting that it is a safer and more effective auxiliary method for pedicle screw placement.

Result Analysis
Print
Save
E-mail