1.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
2.Study on Acupoint Selection Law of Acupuncture and Moxibustion for Treating Postherpetic Neuralgia Based on R Language Data Mining Technology
Yulin WANG ; Leixin LI ; Tiansong YANG ; Jia LIU ; Chunsheng LIN ; Wanying PENG ; Jian ZHAO ; Dapeng BAO ; Wenpeng WU ; Shentian SUN ; Yang CAO ; Di WANG
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(2):39-44
Objective To analyze the acupoint selection law of acupuncture and moxibustion for postherpetic neuralgia(PHN)with R language data mining technology.Methods The clinical research literature on acupuncture and moxibustion treatment of PHN included in CNKI,Wanfang Data,VIP and CBM from January 1,2010 to July 1,2023 was retrieved,and the database was established by Excel 2016.R language was used to statistically analyze the frequency of acupoint usage,meridians,locations,specific acupoints,etc.Through association rule analysis and clustering analysis,the characteristics and law of acupoint selection for acupuncture and moxibustion treatment of PHN were obtained.Results A total of 198 articles were included,including 83 acupoints,with a total frequency of 714 times.The high-frequency acupoints include Ashi acupoint,Jiaji acupoint and Yanglingquan.The commonly used meridians were gallbladder meridian,spleen meridian and large intestine meridiam.The acupoints were mostly in the upper and lower limbs,with the Wushu acupoints,Yuan acupoints and Xiahe acupoints being the most common.The core acupoint was Ashi acupoint,Jiaji acupoint,Hegu,Quchi,and 9 sets of association rules and 5 effective clusters were obtained.Conclusion The most commonly used acupoints for acupuncture and moxibustion treatment of PHN are Ashi acupoint,Jiaji acupoint,Hegu and Quchi,which mainly follow the principle of combining local acupoint selection with distal acupoint selection.
3.Sterilization effect verification of 3D-printed polylactic acid guide plate for orthopedic surgery
Yanqiong LI ; Aiwei YIN ; Naihan CHEN ; Xinghui HU ; Haotian LUO ; Wenpeng ZHAO ; Gang WANG
Chinese Journal of Nosocomiology 2025;35(20):3173-3176
OBJECTIVE To investigate the effects of different sterilization methods on 3D-printed polylactic acid(PLA)guide plates for orthopedic surgery,and to analyze their physical properties,microbial contamination,structural performance and bio compatibility after sterilization.METHODS PLA guide plates for orthopedic surgery were prepared with 3D printing technology and divided into a blank group,a hydrogen peroxide plasma steriliza-tion group,an ethylene oxide sterilization group and a pressure steam sterilization group.Before and after sterili-zation,the changes in volume and weight of the surgical guide plates were measured,microbial detection was con-ducted,structural changes were observed with a laser scanning confocal microscope,and cell co-culture was con-ducted to evaluate biocompatibility,thereby the effects of different sterilization methods were assessed.RESULTS The three sterilization methods had no significant effect on the volume and weight of PLA surgical guide plates.Microbial detection showed that all three sterilization methods were effective in killing bacteria,and bacte-rial cultures were negative.Laser confocal scanning microscopy revealed that sterilization treatment caused certain changes to the microstructure of the surgical guide plates,but high-temperature sterilization had a more pro-nounced effect on the deformation of the guide plate edges.Cell co-culture results indicated that the surgical guide plates treated with the three sterilization methods exhibited acceptable cytotoxicity and had little effect on cell pro-liferation.CONCLUSIONS All three sterilization methods cause microstructural changes to the surgical guide plate.Among them,pressure steam sterilization significantly deforms the structure of the guide plate,directly af-fecting its precise positioning of mutual spatial distances,angular relationships and orientation during surgery.Al-though hydrogen peroxide plasma sterilization does not cause significant deformation,ethylene oxide sterilization has the least impact on material properties and structural stability while ensuring the sterilization effect of PLA surgical guide plates.
4.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
5.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
6.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
7.Low-dose interleukin-2 effectively treats patients with psoriasis by regulating Th17/Treg imbalance and cytokine abnormality in peripheral blood
Wenpeng ZHAO ; Yan LIU ; Zusha QIAO
Chinese Journal of Rheumatology 2025;29(9):741-749
Objective:To explore the therapeutic effect of low-dose interleukin-2 (LdIL-2) on psoriasis and the regulatory role of peripheral blood Th17/Treg imbalance and cytokine disorder.Methods:45 psoriasis patients and 40 healthy individuals were collected from January 2021 to December 2022 in the Second Hospital of Shanxi Medical University. All patients were given with MTX (7.5 mg/week) for 12 weeks, followed by LdIL-2 (50×10 5 U/d×2 weeks×3 courses) until the 24 th week. PASI and ACR20 were collected at the 0, 12th and 24th weeks. Th17, Treg cell, IL-17 and IL-10 were detected. Statistical analysis included t-test, generalized estimating equations, Wilcoxon analysis, Chi-Square Test, Pearson linear correlation analysis, Spearman rank correlation analysis, etc. Results:①The number of patients who reached PASI50/75 in the 24 th week(31,10) was significantly higher than in the 12th week (14, 1), and the differences were statistically significant ( χ2=15.059, P<0.001; χ2=7.111, P=0.004). ②Compared the 0 week with the 24th week, Th17 cell was decreased [1.520%(0.985%, 2.005%) vs. 0.830%(0.675%, 1.125%), H=25.493, P<0.001], Treg cell was increased [3.010%(2.255%, 3.615%) vs.5.190%(4.605%, 6.030%), H=152.106, P<0.001], Th17/Treg ratio also was decreased [0.547(0.348, 0.712) vs. 0.170(0.105, 0.225), H=47.025, P<0.001], and the differences were statistically significant. ③Compared the 0 week with the 24th week, IL-17 was decreased [(19.7±8.7)pg/ml vs. (14.20±6.0)pg/ml, F=21.814, P<0.001], IL-10 was increased [(2.01±0.97)pg/ml vs. (2.62±0.92)pg/ml, F=11.230, P=0.004], IL-17/IL-10 ratio also was decreased [10.644(5.925, 14.705) vs. 5.410(3.455, 7.180), H=16.647, P<0.001], and the differences were statistically significant. ④The correlation analysis showed that PASI were significantly positively correlated with Th17 cells( r=0.598, P<0.001), Th17/Treg( r=0.772, P<0.001), IL-17( r=0.500, P<0.001) and IL-17/IL-10( r=0.776, P<0.001), and significantly negatively correlated with Treg cells( r=-0.822, P<0.001) and IL-10( r=-0.715, P<0.001). Conclusion:LdIL-2 can effectively reverse Th17/Treg imbalance and cytokine disorder in psoriasis patients, significantly alleviate the condition, and has good safety.
8.Sterilization effect verification of 3D-printed polylactic acid guide plate for orthopedic surgery
Yanqiong LI ; Aiwei YIN ; Naihan CHEN ; Xinghui HU ; Haotian LUO ; Wenpeng ZHAO ; Gang WANG
Chinese Journal of Nosocomiology 2025;35(20):3173-3176
OBJECTIVE To investigate the effects of different sterilization methods on 3D-printed polylactic acid(PLA)guide plates for orthopedic surgery,and to analyze their physical properties,microbial contamination,structural performance and bio compatibility after sterilization.METHODS PLA guide plates for orthopedic surgery were prepared with 3D printing technology and divided into a blank group,a hydrogen peroxide plasma steriliza-tion group,an ethylene oxide sterilization group and a pressure steam sterilization group.Before and after sterili-zation,the changes in volume and weight of the surgical guide plates were measured,microbial detection was con-ducted,structural changes were observed with a laser scanning confocal microscope,and cell co-culture was con-ducted to evaluate biocompatibility,thereby the effects of different sterilization methods were assessed.RESULTS The three sterilization methods had no significant effect on the volume and weight of PLA surgical guide plates.Microbial detection showed that all three sterilization methods were effective in killing bacteria,and bacte-rial cultures were negative.Laser confocal scanning microscopy revealed that sterilization treatment caused certain changes to the microstructure of the surgical guide plates,but high-temperature sterilization had a more pro-nounced effect on the deformation of the guide plate edges.Cell co-culture results indicated that the surgical guide plates treated with the three sterilization methods exhibited acceptable cytotoxicity and had little effect on cell pro-liferation.CONCLUSIONS All three sterilization methods cause microstructural changes to the surgical guide plate.Among them,pressure steam sterilization significantly deforms the structure of the guide plate,directly af-fecting its precise positioning of mutual spatial distances,angular relationships and orientation during surgery.Al-though hydrogen peroxide plasma sterilization does not cause significant deformation,ethylene oxide sterilization has the least impact on material properties and structural stability while ensuring the sterilization effect of PLA surgical guide plates.
9.Study on Acupoint Selection Law of Acupuncture and Moxibustion for Treating Postherpetic Neuralgia Based on R Language Data Mining Technology
Yulin WANG ; Leixin LI ; Tiansong YANG ; Jia LIU ; Chunsheng LIN ; Wanying PENG ; Jian ZHAO ; Dapeng BAO ; Wenpeng WU ; Shentian SUN ; Yang CAO ; Di WANG
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(2):39-44
Objective To analyze the acupoint selection law of acupuncture and moxibustion for postherpetic neuralgia(PHN)with R language data mining technology.Methods The clinical research literature on acupuncture and moxibustion treatment of PHN included in CNKI,Wanfang Data,VIP and CBM from January 1,2010 to July 1,2023 was retrieved,and the database was established by Excel 2016.R language was used to statistically analyze the frequency of acupoint usage,meridians,locations,specific acupoints,etc.Through association rule analysis and clustering analysis,the characteristics and law of acupoint selection for acupuncture and moxibustion treatment of PHN were obtained.Results A total of 198 articles were included,including 83 acupoints,with a total frequency of 714 times.The high-frequency acupoints include Ashi acupoint,Jiaji acupoint and Yanglingquan.The commonly used meridians were gallbladder meridian,spleen meridian and large intestine meridiam.The acupoints were mostly in the upper and lower limbs,with the Wushu acupoints,Yuan acupoints and Xiahe acupoints being the most common.The core acupoint was Ashi acupoint,Jiaji acupoint,Hegu,Quchi,and 9 sets of association rules and 5 effective clusters were obtained.Conclusion The most commonly used acupoints for acupuncture and moxibustion treatment of PHN are Ashi acupoint,Jiaji acupoint,Hegu and Quchi,which mainly follow the principle of combining local acupoint selection with distal acupoint selection.
10.Low-dose interleukin-2 effectively treats patients with psoriasis by regulating Th17/Treg imbalance and cytokine abnormality in peripheral blood
Wenpeng ZHAO ; Yan LIU ; Zusha QIAO
Chinese Journal of Rheumatology 2025;29(9):741-749
Objective:To explore the therapeutic effect of low-dose interleukin-2 (LdIL-2) on psoriasis and the regulatory role of peripheral blood Th17/Treg imbalance and cytokine disorder.Methods:45 psoriasis patients and 40 healthy individuals were collected from January 2021 to December 2022 in the Second Hospital of Shanxi Medical University. All patients were given with MTX (7.5 mg/week) for 12 weeks, followed by LdIL-2 (50×10 5 U/d×2 weeks×3 courses) until the 24 th week. PASI and ACR20 were collected at the 0, 12th and 24th weeks. Th17, Treg cell, IL-17 and IL-10 were detected. Statistical analysis included t-test, generalized estimating equations, Wilcoxon analysis, Chi-Square Test, Pearson linear correlation analysis, Spearman rank correlation analysis, etc. Results:①The number of patients who reached PASI50/75 in the 24 th week(31,10) was significantly higher than in the 12th week (14, 1), and the differences were statistically significant ( χ2=15.059, P<0.001; χ2=7.111, P=0.004). ②Compared the 0 week with the 24th week, Th17 cell was decreased [1.520%(0.985%, 2.005%) vs. 0.830%(0.675%, 1.125%), H=25.493, P<0.001], Treg cell was increased [3.010%(2.255%, 3.615%) vs.5.190%(4.605%, 6.030%), H=152.106, P<0.001], Th17/Treg ratio also was decreased [0.547(0.348, 0.712) vs. 0.170(0.105, 0.225), H=47.025, P<0.001], and the differences were statistically significant. ③Compared the 0 week with the 24th week, IL-17 was decreased [(19.7±8.7)pg/ml vs. (14.20±6.0)pg/ml, F=21.814, P<0.001], IL-10 was increased [(2.01±0.97)pg/ml vs. (2.62±0.92)pg/ml, F=11.230, P=0.004], IL-17/IL-10 ratio also was decreased [10.644(5.925, 14.705) vs. 5.410(3.455, 7.180), H=16.647, P<0.001], and the differences were statistically significant. ④The correlation analysis showed that PASI were significantly positively correlated with Th17 cells( r=0.598, P<0.001), Th17/Treg( r=0.772, P<0.001), IL-17( r=0.500, P<0.001) and IL-17/IL-10( r=0.776, P<0.001), and significantly negatively correlated with Treg cells( r=-0.822, P<0.001) and IL-10( r=-0.715, P<0.001). Conclusion:LdIL-2 can effectively reverse Th17/Treg imbalance and cytokine disorder in psoriasis patients, significantly alleviate the condition, and has good safety.

Result Analysis
Print
Save
E-mail