1.Study on the improvement effects of Compound qinbai granules on ulcerative colitis in rats and its mechanism
Shouyan HE ; Wenpeng LUO ; Liao PAN ; Jinyin XIAO ; Zhenquan WANG
China Pharmacy 2025;36(6):686-691
OBJECTIVE To investigate the improvement effects of Compound qinbai granules on ulcerative colitis (UC) in rats and its mechanism based on short-chain fatty acid (SCFA) and their targets G protein-coupled receptor (GPR). METHODS Male SD rats were randomly divided into normal group (12 rats) and model group (30 rats); the model group was given 5% dextran sulfate sodium solution to induce the UC model. Model rats were divided into the model group, positive control group [Mesalazine enteric-coated tablets 270 mg/(kg·d)] and Compound qinbai granules group [2.52 g/(kg·d)], with 9 rats in each group. Rats in each group were orally administered with normal saline or corresponding medication twice a day, for three consecutive weeks. During intragastric administration, the general conditions of rats in each group were observed, and the disease activity index (DAI) scores were assessed after the last administration. Serum levels of pro-inflammatory cytokines (tumor necrosis factor-α, interleukin-6) and anti-inflammatory cytokines (transforming growth factor-β1, interleukin-10) were measured. Pathological changes in their colonic tissues were observed and scored. Additionally, the content of SCFA (acetic acid, propionic acid and butyric acid) in their feces as well as the protein and mRNA expressions of GPR41, GPR43 and GPR109A in colonic tissues were detected. RESULTS Compared with the normal group, rats in the model group exhibited lethargy and obvious blood in their feces; the colonic tissue structure was severely damaged, with pathological changes such as notable glandular loss, edema, and inflammatory cell infiltration visible; the serum levels of pro- inflammatory cytokines, DAI score and colonic pathology score were significantly increased, while the levels of anti-inflammatory cytokines, SCFA content, and protein and mRNA expressions of GPR41, GPR43 and GPR109A were significantly decreased or down-regulated (P<0.01). Compared with the model group, the general condition and pathological changes of colonic tissue in each administration group showed improvement, with significant reversal observed in the aforementioned quantitative indicators (P<0.05 or P<0.01). CONCLUSIONS Compound qinbai granules can alleviate intestinal inflammation and intestinal mucosal damage in UC rats. These effects may be related to its ability to restore intestinal SCFA levels and the expression of their target GPR.
2.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
3.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
4.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
5.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
6.Functional and aesthetic evaluation of external fixator lengthening through plantar approach for fourth brachymetatarsia.
Jiadong ZHANG ; Ning ZHANG ; Zheng HUANG ; Yang WANG ; Wenpeng XU ; Yong HU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(8):1020-1024
OBJECTIVE:
To evaluate the functional and aesthetic evaluation of external fixator lengthening through plantar approach for fourth brachymetatarsia.
METHODS:
A retrospective analysis was conducted on 20 patients (23 feet) with fourth brachymetatarsia who met the selection criteria between January 2016 and January 2024, including 3 males and 17 females, with 8 left, 9 right, and 3 bilateral cases. The mean age was 24.7 years (range, 14-51 years). The preoperative metatarsal shortening length was (13.8±3.2) mm. The preoperative American Orthopaedic Foot and Ankle Society (AOFAS) forefoot score was 79.5±3.9, the visual analogue scale (VAS) score of appearance satisfaction was 1.7±0.8, and the appearance index (AI) score was 13.6±0.9. All patients underwent external fixator lengthening through plantar approach. The lengthening length of metatarsal bone, lengthening ratio, healing time, and healing index were recorded. Functional outcomes were assessed using the AOFAS forefoot score, VAS score of appearance satisfaction, and quality-of-life impact with AI questionnaire.
RESULTS:
All 20 patients were followed up 14-55 months with an average of 36.3 months. During the follow-up, complications occurred in 4 cases (17.4%), including 2 cases of metatarsophalangeal joint stiffness, which had no significant effect on the function and appearance. Delayed union of osteotomy occurred in 1 case (healed at 12 weeks after operation). Pin loosening occurred in 1 case and recovered after outpatient reinforcement. No complications related to plantar scar occurred. At last follow-up, the lengthening length of metatarsal bone was (13.9±3.1) mm, and the lengthening ratio was 25.8%±5.6%. All cases achieved bony union, with a mean healing time of (64.3±12.5) days and a healing index of (46.9±4.8) d/cm. At last follow-up, AOFAS score was 98.9±2.1, the VAS score of appearance satisfaction was 9.3±0.7, and the AI score was 0.6±0.8, which significantly improved when compared with those before operation ( t=27.398, P<0.001; t=32.994, P<0.001; t=56.135, P<0.001).
CONCLUSION
External fixator lengthening through plantar approach is a safe and effective technique for fourth brachymetatarsia, achieving satisfactory functional and aesthetic outcomes.
Humans
;
Male
;
Female
;
Adult
;
External Fixators
;
Retrospective Studies
;
Bone Lengthening/instrumentation*
;
Middle Aged
;
Metatarsal Bones/abnormalities*
;
Adolescent
;
Young Adult
;
Treatment Outcome
;
Patient Satisfaction
;
Esthetics
;
Osteotomy/methods*
;
Foot Deformities, Congenital/surgery*
7.Application of lipidomics in the study of traditional Chinese medicine.
Yang YANG ; Guangyi YANG ; Wenpeng ZHANG ; Lingyi XIN ; Jing ZHU ; Hangtian WANG ; Baodong FENG ; Renyan LIU ; Shuya ZHANG ; Yuanwu CUI ; Qinhua CHEN ; Dean GUO
Journal of Pharmaceutical Analysis 2025;15(2):101083-101083
Lipidomics is an emerging discipline that systematically studies the various types, functions, and metabolic pathways of lipids within living organisms. This field compares changes in diseases or drug impact, identifying biomarkers and molecular mechanisms present in lipid metabolic networks across different physiological or pathological states. Through employing analytical chemistry within the realm of lipidomics, researchers analyze traditional Chinese medicine (TCM). This analysis aids in uncovering potential mechanisms for treating diverse physiopathological conditions, assessing drug efficacy, understanding mechanisms of action and toxicity, and generating innovative ideas for disease prevention and treatment. This manuscript assesses recent literature, summarizing existing lipidomics technologies and their applications in TCM research. It delineates the efficacy, mechanisms, and toxicity research related to lipidomics in Chinese medicine. Additionally, it explores the utilization of lipidomics in quality control research for Chinese medicine, aiming to expand the application of lipidomics within this field. Ultimately, this initiative seeks to foster the integration of traditional medicine theory with modern science and technology, promoting an organic fusion between the two domains.
8.Application of lipidomics in the study of traditional Chinese medicine
Yang YANG ; Guangyi YANG ; Wenpeng ZHANG ; Lingyi XIN ; Jing ZHU ; Hangtian WANG ; Baodong FENG ; Renyan LIU ; Shuya ZHANG ; Yuanwu CUI ; Qinhua CHEN ; Dean GUO
Journal of Pharmaceutical Analysis 2025;15(2):304-316
Lipidomics is an emerging discipline that systematically studies the various types,functions,and metabolic pathways of lipids within living organisms.This field compares changes in diseases or drug impact,identifying biomarkers and molecular mechanisms present in lipid metabolic networks across different physiological or pathological states.Through employing analytical chemistry within the realm of lipidomics,researchers analyze traditional Chinese medicine(TCM).This analysis aids in uncovering potential mechanisms for treating diverse physiopathological conditions,assessing drug efficacy,un-derstanding mechanisms of action and toxicity,and generating innovative ideas for disease prevention and treatment.This manuscript assesses recent literature,summarizing existing lipidomics technologies and their applications in TCM research.It delineates the efficacy,mechanisms,and toxicity research related to lipidomics in Chinese medicine.Additionally,it explores the utilization of lipidomics in quality control research for Chinese medicine,aiming to expand the application of lipidomics within this field.Ultimately,this initiative seeks to foster the integration of traditional medicine theory with modern science and technology,promoting an organic fusion between the two domains.
9.Effects of Shengxue Tongbian Granules on Colonic Myoelectric and Ca2+/CaM/MLCK Signaling Pathway in Rats with Slow Transit Constipation of Blood-deficiency and Intestinal Dryness Syndrome
Wenpeng LUO ; Zhenquan WANG ; Jiamin ZHOU ; Limin XIAO ; Junwen WANG
Chinese Journal of Information on Traditional Chinese Medicine 2024;31(2):97-103
Objective To observe the effects of Shengxue Tongbian Granules on colonic myoelectricity and Ca2+/CaM/MLCK signaling pathway in rats with slow transit constipation(STC)of blood deficiency and intestinal dryness syndrome;To explore its mechanism for the treatment of STC.Methods The STC model of blood deficiency and intestinal dryness syndrome was established by intragastric administration of loperamide combined with tail bloodletting.The rats were divided into control group,model group,mosapride citrate group and Shengxue Tongbian Granules group,with 8 rats in each group.The administration group was given corresponding drugs by gavage for 14 days.The general condition of rats before and after treatment was observed,the fecal water content was detected,the slow wave frequency,amplitude,and coefficient of variation of colonic electromyography were detected using a biological function experimental system,and intestinal propulsion rate was detected.HE staining was used to observe the pathological changes of colon tissue,the concentration of Ca2+ in colonic smooth muscle cells was detected by colorimetry,the expression of Cx43,calmodulin(CaM),myosin light chain kinase(MLCK)and p-MLC20 in smooth muscle tissue were detected by Western blot.Results Compared with the control group,the body mass,fecal water content and intestinal propulsion rate of rats in the model group decreased(P<0.01),the slow wave frequency of colonic electromyography slowed down,the coefficient of variation of frequency increased(P<0.01),and the amplitude and coefficient of variation of slow wave increased(P<0.01);colonic mucosal structure was damaged,with visible inflammatory changes and significant erosion,and the concentration of Ca2+ and the expressions of Cx43,CaM,MLCK,p-MLC20 proteins in colonic smooth muscle cells were significantly decreased(P<0.01).Compared with the model group,the body mass,fecal water content and intestinal propulsion rate of the rats in the mosapride citrate group and the Shengxue Tongbian Granules group significantly increased(P<0.05,P<0.01),the slow wave frequency of colonic electromyography increased and the coefficient of variation of frequency decreased(P<0.01),and the slow wave amplitude and amplitude variation coefficient decreased(P<0.05,P<0.01);the colonic mucosal structure was relatively intact,the erosion situation was improved,and the Ca2+ concentration,Cx43,CaM,MLCK and p-MLC20 protein expressions in colonic smooth muscle cells significantly increased(P<0.01).Conclusion Shengxue Tongbian Granules can improve defecation symptoms and promote colonic motility in STC rats with blood deficiency and intestinal dryness syndrome,which may be related to regulating colonic myoelectric rhythm and activating Ca2+/CaM/MLCK signaling pathway.
10.The value of spectral CT combined with metal artifact reduction algorithms in improving the CT image quality for patients with 125I seeds implantation in the chest and abdomen
Yuhan ZHOU ; Limin LEI ; Zhihao WANG ; Wenpeng HUANG ; Weimeng CAO ; Shushan DONG ; Meng WANG ; Zhigang ZHOU
Chinese Journal of Radiology 2024;58(2):172-179
Objective:To investigate the value of the virtual monoenergetic image (VMI) obtained by a new dual-layer detector spectral CT combined with metal artifact reduction algorithms(O-MAR) in reduction of different types of artifacts caused by 125I seeds implantation and in improvement of the post-operative CT image quality. Methods:This was a cross-sectional study. Thirty-five patients who underwent dual-layer detector spectral CT scanning of the chest and abdomen after 125I seeds implantation were retrospectively included at the First Affiliated Hospital of Zhengzhou University from March to September 2022. The spectral data were collected and reconstructed into conventional CT image (CI), VMI image (50-150 keV, 20 keV/level), CI+O-MAR image, and VMI+O-MAR image (50-150 keV, 20 keV/level). The artifacts′ removal effects and image quality improvement in each group were evaluated. Two slices with the strongest artifacts were selected for analysis for each patient, resulting in a total of 70 slices. Objective indicators including artifact index (AI), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of soft tissue regions affected by artifacts were measured and calculated. Subjective indicators including the overcorrected artifacts and new artifacts, the different forms of artifacts, the diagnosis of artifacts, and the image quality were assessed. One-way analysis of variance was used for comparisons among multiple groups. Paired t test was used to compare the quantitative indicators between the combined O-MAR group and the non-O-MAR group. Kappa statistics was used to evaluate the consistency between observers. Results:In high/low-density artifacts (ROI H/L), the AI values in all groups showed decrease with increasing VMI keV. In artifact-affected tissue (ROI T), SNR of the CI/VMI (70-150 keV)+O-MAR group were significantly higher than those of the CI/VMI group ( P<0.05), CNR of the CI/VMI(50-150 keV)+O-MAR group were significantly higher than those of the CI/VMI group ( P<0.05). Both overcorrection and new artifacts mainly presented in VMI 50 keV and VMI 70 keV groups; Compared with VMI (50-70 keV) group, significantly less numbers of overcorrection and new artifacts were found in VMI (50-70 keV)+O-MAR group ( P<0.05); regarding the comparison of artifact types, with the VMI keV increasing, the number of a-type banded artifacts gradually decreased on images with high-density artifacts, reaching a minimum of 3 in the VMI 150 keV+O-MAR group; while the number of e-type artifacts with little or no artifacts increased, with the highest number of 23 in the VMI 150 keV+O-MAR group. The total number of high-density artifacts in each type decreased with increasing VMI keV. As VMI keV increased, the diagnostic and image quality scores of high-density artifacts in each group were significantly higher than those of low-density artifacts in the VMI+O-MAR group ( P<0.05). Conclusions:VMI combined with O-MAR can significantly improve the objective and subjective image quality of follow-up CT imaging after 125I seed implantation, enhancing lesion visibility and diagnostic confidence. Additionally, VMI+O-MAR showed more pronounced correction effect on high-density artifacts.

Result Analysis
Print
Save
E-mail