1.Effect of Linaclotide combined with Simethicone and compound polyethylene glycol electrolyte on cleansing effect of bowel in patients with constipation
Jinwen LIAO ; Wenli SHEN ; Lan WU ; Wenxiu LONG ; Wei ZHAO ; Ming WANG ; Zhiqiang DU
China Journal of Endoscopy 2025;31(6):44-53
Objective To investigate the efficacy and safety of Linaclotide combined with Simethicone oil and compound polyethylene glycol electrolyte(PEG)for cleansing effect of bowel in patients with constipation.Methods A prospective randomized controlled trial was designed and implemented by single blind method.383 patients with constipation who underwent colonoscopy from April 2023 to August 2024 were enrolled and randomly divided into routine group(128 cases),experimental group A(128 cases)and experimental group B(127 cases).Routine group treated with 3 L PEG,experimental group A treated with 290 μg Linaclotide+2 L PEG and experimental group B treated with 290 μg Linaclotide+30 mL Simethicone+2 L PEG.Bowel preparation effect[Boston bowel preparation scale(BBPS)scores and foaming removal effect],lesion detection rate,first defecation interval,frequency of defecation,the success rate of cecal intubation,the insertion time of colonoscopy,the withdrawal time of colonoscopy,incidence of adverse reactions and willingness to repeat examination of the three groups were compared.Results No statistically significant differences were observed in the BBPS scores among the three groups(P>0.05);The foaming removal effect score in experimental group B was significantly lower than that in routine group and experimental group A,the difference was statistically significant(P<0.05);The total lesion detection rate and polyps detection rate of experimental group B were significantly higher than those of routine group and experimental group A,the differences were statistically significant(P<0.05).The first defecation interval of the routine group was significantly longer than that of experimental group A and experimental group B,the difference was statistically significant(P<0.05);The frequency of defecation was compared among the three groups,and the difference was no statistically significant(P>0.05).The success rate of cecal intubation in the three groups was 100.0%,and the insertion time of colonoscopy was similar,the differences were not statistically significant(P>0.05);The withdrawal time of colonoscopy in experimental group B was significantly shorter than that in routine group and experimental group A,the difference was statistically significant(P<0.05).The incidence of abdominal distension and total adverse reactions in the routine group were higher than those in experimental group A and experimental group B,the differences were statistically significant(P<0.05);The willingness to repeat examination rate of the routine group was significantly lower than that of experimental group A and experimental group B,the differences were statistically significant(P<0.05).Conclusion 290 μg Linaclotide combined with 30 mL Simethicone and 2 L PEG solution regimen has advantages in intestinal preparation for patients with constipation,and can achieve better intestinal cleaning effect than 3 L PEG solution and 290 μg linalopeptide+2 L PEG solution regimen,with higher safety and willingness to repeat examination.It can be recommended for bowel preparation for patients with constipation.
2.Comparison of two swept-source optical coherence tomography biometers for the measurement of ocular biological parameters in cataracts
Yifeng LI ; Wenli YANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Rui CUI ; Lin SHEN
Recent Advances in Ophthalmology 2025;45(6):481-485
Objective To compare the difference,agreement,and axial length measurement success rate between biometers ZW-30 and IOLMaser 700 based on swept-source optical coherence tomography for the measurement of ocular bi-ological parameters in patients with cataracts.Methods A total of 126 cataract patients(233 eyes)who were advised to undergo cataract surgery at the Department of Ophthalmology at Beijing Tongren Hospital,Capital Medical University from January to February 2024 were included in this study.Two biometers were used to measure the axial length(AL),mean keratometry(Km),anterior chamber depth(ACD),lens thickness(LT),central corneal thickness(CCT),and horizontal corneal diameter[namely,the white-to-white(WTW)distance].The axial measurement success rate of the two biometers and the difference and agreement between the parameters were calculated.Results The mean difference between ZW-30 and IOLMaster 700 was(-0.006±0.042)mm for AL,(-0.074±0.204)D for Km,(0.031±0.051)mm for ACD,(0.001±0.005)mm for CCT,and(-0.286±0.337)mm for WTW,and the differences were statistically significant(all P<0.05).The mean difference between ZW-30 and IOLMaster 700 was(0.008±0.215)mm for LT,and the difference was not statis-tically significant(t=0.579,P=0.563).The 95%limits of agreement range was between-0.011 mm and 0.000 mm for AL,between-0.474 D and 0.326 D for Km,between-0.010 mm and 0.012 mm for CCT,between-0.068 mm and 0.131 mm for ACD,between-0.116 mm and 0.159 mm for LT,and between-0.947 mm and 0.376 mm for WTW.The intra-class correlation coefficient of all measurements ranged from 0.790 to 1.000.The AL measurement success rate of IOLMaster 700 and ZW-30 was 95.3%and 95.7%,respectively.The latter had an AL measurement success rate of 98.7%after manually marking the position of the retinal identification line.Conclusion There were statistically significant differences between ZW-30 and IOLMaster 700 in the measurement of the AL,Km,ACD,and CCT,which,however,were not clinically significant.The agreement between both was good.ZW-30 had a higher AL measurement success rate,espe-cially for the manual identification function of eyes with opacified refractive media,which can further improve the AL meas-urement success rate and provide reference for clinical work.
3.Perceived stress and occupational burnout among hospital staff in Guangzhou tertiary hospitals
Wenli ZHOU ; Xiaoyi WU ; Yichen YE ; Liman WU ; Biyun CHEN ; Yi SHEN
Journal of Environmental and Occupational Medicine 2025;42(3):354-359
Background Staff in tertiary hospitals are a high-risk group for occupational burnout. Timely identification and precise intervention are crucial for improving healthcare service quality. However, comparative studies on perceived stress and occupational burnout among hospital staff in different positions are lacking. Objective To describe the status of perceived stress and occupational burnout among hospital staff in different positions and compare the differences, explore the relationship between perceived stress and occupational burnout, and identify the influencing factors of occupational burnout. Methods In May 2022,
4.Research on the equity of maternal health service utilization in Changning District, Shanghai
Ying HUANG ; Wenli FANG ; Fang BU ; Ye SHEN ; Ning QIAN ; Xuelin BAI ; Shuo YU ; Ji LIANG
Journal of Public Health and Preventive Medicine 2025;36(6):137-141
Objective To understand the equity and influencing factors of maternal health service utilization in Changning District, Shanghai. Methods A convenience sampling method was used to conduct a questionnaire survey among mothers of children aged 1 to 1.5 years old who received health services from the child health care clinics and EPI clinics of 10 community health service centers in Changning District, Shanghai from March to April 2022. Count data was expressed by frequency and percentage. Chi-square analysis, binomial logistic regression analysis, and multivariate logistic regression analysis were used to analyze fairness-related factors. Rate difference, rate ratio and concentration index were used to represent fairness. Results A total of 696 subjects were investigated, with an average age of (33.35±4.76) years. There were statistically significant differences in service utilization among women with different household registrations only in early pregnancy registration (χ2=11.026, P=0.001) and postpartum visits (χ2=4.989, P=0.026). Women with a career showed differently in folic acid supplement (χ2=6.247, P=0.012), early pregnancy registration (χ2=12.989, P=0.002), physical examination in 42 days postpartum (χ2=4.446, P=0.035) and postpartum contraception (χ2=4.061, P=0.044), and the differences were statistically significant. Women with different monthly family income had a statistically significant difference in pre-pregnancy examination (χ2=8.977, P=0.030) and postpartum visit (χ2=16.114, P=0.001). There was a statistically significant difference between women with maternity insurance or not in the early pregnancy registration (χ2=10.576, P=0.001) and physical examination in 42 days postpartum (χ2=8.166, P=0.004). The results of the multivariate analysis showed that occupation (OR=2.616, 95% CI: 1.142-5.990) and maternity insurance (OR=4.490, 95% CI: 1.992~10.120) affected the utilization of service in early pregnancy registration. The monthly household income (OR=0.278, 95% CI: 0.124-0.625) affected the utilization of services in postpartum visit. At the same time, the monthly household income (10,000-19,999: OR=0.286, 95% CI: 0.090-0.907; ≥30,000: OR=0.180, 95% CI: 0.041-0.801) also affected the utilization of service in physical examination in 42 days postpartum. Conclusion The equity of maternal health care service utilization overall is good in central area in Shanghai, but there is still room for improvement. It is necessary to strengthen community mobilization, propagandize maternal health services, and expand the coverage of maternity insurance to improve the equity of maternal health service utilization and provide equal access to maternity health services.
5.Safety and effectiveness of lecanemab in Chinese patients with early Alzheimer's disease: Evidence from a multidimensional real-world study.
Wenyan KANG ; Chao GAO ; Xiaoyan LI ; Xiaoxue WANG ; Huizhu ZHONG ; Qiao WEI ; Yonghua TANG ; Peijian HUANG ; Ruinan SHEN ; Lingyun CHEN ; Jing ZHANG ; Rong FANG ; Wei WEI ; Fengjuan ZHANG ; Gaiyan ZHOU ; Weihong YUAN ; Xi CHEN ; Zhao YANG ; Ying WU ; Wenli XU ; Shuo ZHU ; Liwen ZHANG ; Naying HE ; Weihuan FANG ; Miao ZHANG ; Yu ZHANG ; Huijun JU ; Yaya BAI ; Jun LIU
Chinese Medical Journal 2025;138(22):2907-2916
INTRODUCTION:
Lecanemab has shown promise in treating early Alzheimer's disease (AD), but its safety and efficacy in Chinese populations remain unexplored. This study aimed to evaluate the safety and 6-month clinical outcomes of lecanemab in Chinese patients with mild cognitive impairment (MCI) or mild AD.
METHODS:
In this single-arm, real-world study, participants with MCI due to AD or mild AD received biweekly intravenous lecanemab (10 mg/kg). The study was conducted at Hainan Branch, Ruijin Hospital Shanghai Jiao Tong University School of Medicine. Patient enrollment and baseline assessments commenced in November 2023. Safety assessments included monitoring for amyloid-related imaging abnormalities (ARIA) and other adverse events. Clinical and biomarker changes from baseline to 6 months were evaluated using cognitive scales (mini-mental state examination [MMSE], montreal cognitive assessment [MoCA], clinical dementia rating-sum of boxes [CDR-SB]), plasma biomarker analysis, and advanced neuroimaging.
RESULTS:
A total of 64 patients were enrolled in this ongoing real-world study. Safety analysis revealed predominantly mild adverse events, with infusion-related reactions (20.3%, 13/64) being the most common. Of these, 69.2% (9/13) occurred during the initial infusion and 84.6% (11/13) did not recur. ARIA-H (microhemorrhages/superficial siderosis) and ARIA-E (edema/effusion) were observed in 9.4% (6/64) and 3.1% (2/64) of participants, respectively, with only two symptomatic cases (one ARIA-E presenting with headache and one ARIA-H with visual disturbances). After 6 months of treatment, cognitive scores remained stable compared to baseline (MMSE: 22.33 ± 5.58 vs . 21.27 ± 4.30, P = 0.733; MoCA: 16.38 ± 6.67 vs . 15.90 ± 4.78, P = 0.785; CDR-SB: 2.30 ± 1.65 vs . 3.16 ± 1.72, P = 0.357), while significantly increasing plasma amyloid-β 42 (Aβ42) (+21.42%) and Aβ40 (+23.53%) levels compared to baseline.
CONCLUSIONS:
Lecanemab demonstrated a favorable safety profile in Chinese patients with early AD. Cognitive stability and biomarker changes over 6 months suggest potential efficacy, though high dropout rates and absence of a control group warrant cautious interpretation. These findings provide preliminary real-world evidence for lecanemab's use in China, supporting further investigation in larger controlled studies.
REGISTRATION
ClinicalTrials.gov , NCT07034222.
Humans
;
Alzheimer Disease/drug therapy*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Cognitive Dysfunction/drug therapy*
;
Aged, 80 and over
;
Amyloid beta-Peptides/metabolism*
;
Biomarkers
;
East Asian People
6.Analysis of anterior chamber and lens characteristics in age-related cataract patients with zonular weakness based on CASIA2
Lin SHEN ; Wenli YANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Qian LIU ; Chuanchuan WEI ; Rongyao ZHOU ; Yifan LI
Chinese Journal of Experimental Ophthalmology 2025;43(3):227-232
Objective:To analyze the biological parameters of the anterior segment of age-related cataracts patients with or without zonular weakness with the new generation of sweep-source anterior optical coherence tomography (OCT) device CASIA2 to provide a basis for the diagnosis of zonular weakness.Methods:A case-control study was conducted.A total of 158 cases (186 eyes) of patients with age-related cataracts having zonular weakness as a zonular weakness group, and 80 cases (80 eyes) of cataract with age-related cataracts without zonular weakness as a normal zonule group were enroll from June 2022 to June 2023 at Beijing Tongren Hospital.All patients underwent routine preoperative ophthalmological examination including slit lamp microsopy, IOLMaster 700, ocular B-ultrasound and OCT.The anterior chamber depth (ACD), anterior chamber volume (ACV), lens thickness (LT), lens vault (LV), anterior chamber angle opening distance at 750 μm (AOD750), lens decentration and tilt, radius of curvature of the anterior lens surface (RAL), and radius of curvature of the posterior lens surface (RPL) of patients were measured with CASIA2 and compared between the two groups.The relationship between zonular weakness and anterior chamber parameters and lens parameters was evaluated by logistic regression analysis.This study followed the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Beijing Tongren Hospital (No.TRECKY2018-049), and all enrolled patients signed the informed consent form.Results:In the zonular weakness group, ACD, ACV, RAL, and AOD750 were (2.34±0.56)mm, (85.05±40.19)mm 3, 7.52 (7.13, 8.08)mm, and 0.27 (0.07, 0.30)mm, respectively, which were smaller than (3.13±0.38)mm, (127.75±38.15)mm 3, 9.28(8.51, 9.76)mm, and 0.52 (0.31, 0.65)mm in the normal zonule group, with statistically significant differences (all P<0.05).LT and LV in the zonular weakness group were (5.14±0.45)mm and (1.22±0.53)mm, respectively, which were larger than (4.27±0.52)mm and (0.32±0.30)mm in the normal zonule group, and the differences were statistically significant (both P<0.05).Magnitude of lens decentration and tilt in the zonular weakness were 0.34 (0.13, 0.45)mm and 6.44 (3.67, 7.32)°, respectively, which were significantly larger than 0.19 (0.12, 0.25)mm and 4.88 (3.85, 5.65)° in the normal zonule group (both P<0.05).No obvious pattern was found in the direction of decentration and tilt.Logistic regression analysis showed that LV and lens decentration were risk factors of zonular weakness (odds ratios [ OR]=706.170, 335.339; both P<0.05), and RAL was a protective factor of zonular weakness ( OR=0.239, P<0.05). Conclusions:Age-related cataract patients with zonular weakness often present with a decrease in ACV due to increased anterior convexity of the lens.Decreased RAL, increased lens decentration and elevated LV are risk factors for zonular weakness.
7.Ultrasound imaging manifestations of idiopathic uveal effusion syndrome
Lin SHEN ; Zhijun SHEN ; Wenli YANG ; Hong WANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Qian LIU
Chinese Journal of Ocular Fundus Diseases 2025;41(5):381-385
Objective:To observe the ultrasonographic features of idiopathic uveal effusion syndrome (IUES).Methods:A retrospective controlled study. From January 2012 to December 2023, 13 patients with IUES (26 eyes) diagnosed by ophthalmology examination in Department of Ophthalmonogy of Beijing Tongren Hospital (IUES group) and 22 healthy people with 30 eyes (control group) were included in the study. Both eyes of all participants were examined by color Doppler ultrasound (CDU) and ultrasonic biomicroscopy (UBM). The thickness of the ocular wall at 300 μm on the temporal side of the optic disc was measured by CDU. UBM was used to measure the thickness of the nasal and temporal scleral processes. Corneal thickness (CT), anterior chamber depth (AD), lens thickness (LT) and axial length (AL) were measured by A-mode ultrasound. There were no significant differences in age ( t=0.842), sex component ratio ( χ2=0.540), eye difference ( χ2=0.108) and AL ( t=0.831) between IUES group and control group ( P>0.05). The CDU and UBM imaging features and biometrics of IUES affected eyes were observed. Independent sample t test was used for comparison between groups. Results:CDU examination results showed that in 26 eyes of IUES group, choroidal detachment occurred in 20 eyes (76.9%, 20/26), which showed arc-shaped band echo connected with peripheral and equatorial eye wall echo, with uniform low echo area below, and blood flow signal could be seen on the band echo. The echo thickened and decreased in 4 eyes (15.3%, 4/26). Nine eyes (33.3%, 9/26) were accompanied by retinal detachment, which showed that the posterior pole vitreous echo was connected to the optic disc echo, and the blood flow signal was seen on the ribbon echo. UBM results showed ciliary detachment in 22 eyes (84.7%, 22/26), showing a spongy thickening of the ciliary body with interlamellar echo separation and an echoless area between the sclera. Ciliary body echo thickened and decreased in 2 eyes (7.7%, 2/26). Shallow space between ciliary body and sclera was observed in 2 eyes (7.7%, 2/26). Compared with the control group, CT ( Z=2.054), LT ( Z=1.867), scleral thickness ( Z=2.536) and ocular wall thickness ( Z=2.094) were thickened in IUES group, and AD ( Z=1.888) were decreased, with statistical significance ( P<0.05). Conclusions:The CDU of IUES is characterized by a thickened echo of the ocular wall and a uniform low echo area under the detached choroid. UBM is characterized by a spongy thickening of the ciliary body echo with interlaminar echo separation.
8.Analysis of color Doppler flow imaging characteristics of vitreoretinal lymphoma
Ziyang WANG ; Wenli YANG ; Dongjun LI ; Wei CHEN ; Lin SHEN ; Yifeng LI ; Rui CUI ; Qian LIU ; Wenbin WEI
Chinese Journal of Ocular Fundus Diseases 2025;41(9):679-683
Objective:To observe the color Doppler flow imaging (CDFI) features of vitreoretinal lymphoma (VRL).Methods:Retrospective case series. From January 2022 to December 2024, 71 eyes of 42 patients diagnosed with VRL at the Eye Center of Beijing Tongren Hospital were enrolled. Among them, 17 were male and 25 female; 29 had bilateral and 13 unilateral involvement. Age ranged 17-78 years (median 59 years). Eleven cases had histopathologic confirmation and 31 were clinically diagnosed. All patients underwent CDFI and optical coherence tomography (OCT). CDFI findings were analyzed, noting the presence or absence of vitreous opacities (centrifugal distribution), posterior vitreous detachment (PVD), retinal detachment, and retinal elevated lesions. With Doppler overlay, blood flow within retinal lesions was assessed. The χ 2 test was used to compare the detection rates of retinal lesions by CDFI and OCT, while Cohen’s Kappa assessed agreement in identifying the depth of lymphoma cell infiltration. Results:Among 71 eyes, vitreous opacity occurred in 66 eyes (93.0%, 66/71), of which 40 eyes (60.6%, 40/66) showed centrifugal opacity. 58 eyes (81.7%, 58/71) had posterior vitreous detachment. Retinal detachment occurred in 7 eyes (9.9%, 7/71). Retinal occupying lesions occurred in 23 eyes (32.4%, 23/61), of which 15 eyes (65.2%, 15/23) showed blood flow signals on the surface of the lesions but no blood flow signals inside the lesions by CDFI, and OCT showed that tumor cells gathered under the retinal pigment epithelium. CDFI showed blood flow signals inside the lesions in 8 eyes (34.8%, 8/23), and OCT showed that tumor cells gathered between retinal neuroepithelial layers. The lesion detection rate of OCT (69.6%, 16/23) was significantly lower than that of CDFI (100.0%, 23/23) ( χ 2= 6.066, P=0.014). OCT and CDFI showed perfect agreement in determining the depth of tumor cell infiltration (Kappa=1.0). Conclusions:The ultrasonographic manifestations of VRL include vitreous opacity, PVD, and some retinal occupying lesions. Vitreous opacity often presents a characteristic centrifugal distribution. By observing whether there is blood flow signal in retinopathy using Doppler, the level of lymphoma cell infiltration can be suggested.
9.Analysis of anterior chamber and lens characteristics in age-related cataract patients with zonular weakness based on CASIA2
Lin SHEN ; Wenli YANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Qian LIU ; Chuanchuan WEI ; Rongyao ZHOU ; Yifan LI
Chinese Journal of Experimental Ophthalmology 2025;43(3):227-232
Objective:To analyze the biological parameters of the anterior segment of age-related cataracts patients with or without zonular weakness with the new generation of sweep-source anterior optical coherence tomography (OCT) device CASIA2 to provide a basis for the diagnosis of zonular weakness.Methods:A case-control study was conducted.A total of 158 cases (186 eyes) of patients with age-related cataracts having zonular weakness as a zonular weakness group, and 80 cases (80 eyes) of cataract with age-related cataracts without zonular weakness as a normal zonule group were enroll from June 2022 to June 2023 at Beijing Tongren Hospital.All patients underwent routine preoperative ophthalmological examination including slit lamp microsopy, IOLMaster 700, ocular B-ultrasound and OCT.The anterior chamber depth (ACD), anterior chamber volume (ACV), lens thickness (LT), lens vault (LV), anterior chamber angle opening distance at 750 μm (AOD750), lens decentration and tilt, radius of curvature of the anterior lens surface (RAL), and radius of curvature of the posterior lens surface (RPL) of patients were measured with CASIA2 and compared between the two groups.The relationship between zonular weakness and anterior chamber parameters and lens parameters was evaluated by logistic regression analysis.This study followed the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Beijing Tongren Hospital (No.TRECKY2018-049), and all enrolled patients signed the informed consent form.Results:In the zonular weakness group, ACD, ACV, RAL, and AOD750 were (2.34±0.56)mm, (85.05±40.19)mm 3, 7.52 (7.13, 8.08)mm, and 0.27 (0.07, 0.30)mm, respectively, which were smaller than (3.13±0.38)mm, (127.75±38.15)mm 3, 9.28(8.51, 9.76)mm, and 0.52 (0.31, 0.65)mm in the normal zonule group, with statistically significant differences (all P<0.05).LT and LV in the zonular weakness group were (5.14±0.45)mm and (1.22±0.53)mm, respectively, which were larger than (4.27±0.52)mm and (0.32±0.30)mm in the normal zonule group, and the differences were statistically significant (both P<0.05).Magnitude of lens decentration and tilt in the zonular weakness were 0.34 (0.13, 0.45)mm and 6.44 (3.67, 7.32)°, respectively, which were significantly larger than 0.19 (0.12, 0.25)mm and 4.88 (3.85, 5.65)° in the normal zonule group (both P<0.05).No obvious pattern was found in the direction of decentration and tilt.Logistic regression analysis showed that LV and lens decentration were risk factors of zonular weakness (odds ratios [ OR]=706.170, 335.339; both P<0.05), and RAL was a protective factor of zonular weakness ( OR=0.239, P<0.05). Conclusions:Age-related cataract patients with zonular weakness often present with a decrease in ACV due to increased anterior convexity of the lens.Decreased RAL, increased lens decentration and elevated LV are risk factors for zonular weakness.
10.Comparison of two swept-source optical coherence tomography biometers for the measurement of ocular biological parameters in cataracts
Yifeng LI ; Wenli YANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Rui CUI ; Lin SHEN
Recent Advances in Ophthalmology 2025;45(6):481-485
Objective To compare the difference,agreement,and axial length measurement success rate between biometers ZW-30 and IOLMaser 700 based on swept-source optical coherence tomography for the measurement of ocular bi-ological parameters in patients with cataracts.Methods A total of 126 cataract patients(233 eyes)who were advised to undergo cataract surgery at the Department of Ophthalmology at Beijing Tongren Hospital,Capital Medical University from January to February 2024 were included in this study.Two biometers were used to measure the axial length(AL),mean keratometry(Km),anterior chamber depth(ACD),lens thickness(LT),central corneal thickness(CCT),and horizontal corneal diameter[namely,the white-to-white(WTW)distance].The axial measurement success rate of the two biometers and the difference and agreement between the parameters were calculated.Results The mean difference between ZW-30 and IOLMaster 700 was(-0.006±0.042)mm for AL,(-0.074±0.204)D for Km,(0.031±0.051)mm for ACD,(0.001±0.005)mm for CCT,and(-0.286±0.337)mm for WTW,and the differences were statistically significant(all P<0.05).The mean difference between ZW-30 and IOLMaster 700 was(0.008±0.215)mm for LT,and the difference was not statis-tically significant(t=0.579,P=0.563).The 95%limits of agreement range was between-0.011 mm and 0.000 mm for AL,between-0.474 D and 0.326 D for Km,between-0.010 mm and 0.012 mm for CCT,between-0.068 mm and 0.131 mm for ACD,between-0.116 mm and 0.159 mm for LT,and between-0.947 mm and 0.376 mm for WTW.The intra-class correlation coefficient of all measurements ranged from 0.790 to 1.000.The AL measurement success rate of IOLMaster 700 and ZW-30 was 95.3%and 95.7%,respectively.The latter had an AL measurement success rate of 98.7%after manually marking the position of the retinal identification line.Conclusion There were statistically significant differences between ZW-30 and IOLMaster 700 in the measurement of the AL,Km,ACD,and CCT,which,however,were not clinically significant.The agreement between both was good.ZW-30 had a higher AL measurement success rate,espe-cially for the manual identification function of eyes with opacified refractive media,which can further improve the AL meas-urement success rate and provide reference for clinical work.


Result Analysis
Print
Save
E-mail