1.The short-term effect of using VISULYZE generated nomogram to assist SMILE for myopia and astigmatism correction
Yan ZHAO ; Wenjia CAO ; Di SHEN ; Jun CAI ; Xiaohuan MA ; Wei WEI
Recent Advances in Ophthalmology 2025;45(10):805-809
Objective To evaluate the short-term efficacy of the VISULYZE software generated nomogram in assis-ting small incision lenticule extraction(SMILE)for the correction of myopia and astigmatism.Methods Non-randomized controlled trial.Patients who underwent SMILE surgery with the original nomogram,assisted by the same surgeon at the Laser Myopia Treatment Center of Xi'an NO.1 Hospital between February 2023 and January 2024,were included.A total of 52 patients(102 eyes)of myopic astigmatism with 3-month postoperative follow-up were collected.VISULYZE software was then used to generate a new nomogram.Subsequently,a total of 40 patients(70 eyes)with myopic with-the-rule astigmatism and a preoperative cylinder of ≤2.00 D,who underwent SMILE assisted by the new nomogram at the same center between August and November 2024,were enrolled.Among them,50 eyes had a target refraction of plano and were assigned to the experimental group.In addition,from the database of patients who underwent SMILE assisted by the origi-nal nomogram,42 patients(70 eyes)with myopic with-the-rule astigmatism and a cylinder of ≤2.00 D were screened,of which 51 eyes had a target refraction of plano,and these were assigned to the control group.The postoperative visual and refractive outcomes of both groups were compared at 3 months.Astigmatism results were analyzed using Alpins vector analysis.Results At 3 months postoperatively,among eyes with a target refraction of plano,50 eyes(98.0%)in the control group and all 50 eyes(100.0%)in the experimental group achieved an uncorrected distance visual acuity(UDVA)of ≥ 20/20.No eye in either group experienced a loss of more than one line in corrected distance visual acuity(CDVA)compared with the preoperative level.At 3 months postoperatively,63 eyes(90.0%)in the control group and 66 eyes(94.3%)in the experimental group had a spherical equivalent(SE)within-0.50 to 0.50 D.The postoperative cylinder was significantly lower in the experimental group than in the control group(P<0.05).Vector analysis revealed that the ex-perimental group had smaller values for the difference vector,index of success,and absolute angle of error than the control group,with all differences being statistically significant(all P<0.05).At 3 months postoperatively,43 eyes(61.4%)in the control group and 57 eyes(81.4%)in the experimental group had an angle of error within-5° to 5°.Conclusion The use of the VISULYZE software generated nomogram can optimize SMILE surgery design,offering good efficacy,safety,and predictability,and improving the precision of SMILE surgery for correcting myopia and astigmatism.
2.The short-term effect of using VISULYZE generated nomogram to assist SMILE for myopia and astigmatism correction
Yan ZHAO ; Wenjia CAO ; Di SHEN ; Jun CAI ; Xiaohuan MA ; Wei WEI
Recent Advances in Ophthalmology 2025;45(10):805-809
Objective To evaluate the short-term efficacy of the VISULYZE software generated nomogram in assis-ting small incision lenticule extraction(SMILE)for the correction of myopia and astigmatism.Methods Non-randomized controlled trial.Patients who underwent SMILE surgery with the original nomogram,assisted by the same surgeon at the Laser Myopia Treatment Center of Xi'an NO.1 Hospital between February 2023 and January 2024,were included.A total of 52 patients(102 eyes)of myopic astigmatism with 3-month postoperative follow-up were collected.VISULYZE software was then used to generate a new nomogram.Subsequently,a total of 40 patients(70 eyes)with myopic with-the-rule astigmatism and a preoperative cylinder of ≤2.00 D,who underwent SMILE assisted by the new nomogram at the same center between August and November 2024,were enrolled.Among them,50 eyes had a target refraction of plano and were assigned to the experimental group.In addition,from the database of patients who underwent SMILE assisted by the origi-nal nomogram,42 patients(70 eyes)with myopic with-the-rule astigmatism and a cylinder of ≤2.00 D were screened,of which 51 eyes had a target refraction of plano,and these were assigned to the control group.The postoperative visual and refractive outcomes of both groups were compared at 3 months.Astigmatism results were analyzed using Alpins vector analysis.Results At 3 months postoperatively,among eyes with a target refraction of plano,50 eyes(98.0%)in the control group and all 50 eyes(100.0%)in the experimental group achieved an uncorrected distance visual acuity(UDVA)of ≥ 20/20.No eye in either group experienced a loss of more than one line in corrected distance visual acuity(CDVA)compared with the preoperative level.At 3 months postoperatively,63 eyes(90.0%)in the control group and 66 eyes(94.3%)in the experimental group had a spherical equivalent(SE)within-0.50 to 0.50 D.The postoperative cylinder was significantly lower in the experimental group than in the control group(P<0.05).Vector analysis revealed that the ex-perimental group had smaller values for the difference vector,index of success,and absolute angle of error than the control group,with all differences being statistically significant(all P<0.05).At 3 months postoperatively,43 eyes(61.4%)in the control group and 57 eyes(81.4%)in the experimental group had an angle of error within-5° to 5°.Conclusion The use of the VISULYZE software generated nomogram can optimize SMILE surgery design,offering good efficacy,safety,and predictability,and improving the precision of SMILE surgery for correcting myopia and astigmatism.
3.Application progress of multi-agent systems in pain management for cancer patients
Mengxin HE ; Wenjia WEI ; Defeng CHEN ; Wanlin PENG ; Bei LI ; Xuhui DONG ; Jiabao LI ; Yang YANG
Chinese Journal of Modern Nursing 2025;31(2):266-270
Cancer patients often experience worsening pain due to the limitations of traditional pharmacological treatments. This paper explores the innovative application of multi-agent systems in this field. As a key component of artificial intelligence, multi-agent systems assist healthcare providers in making intelligent decisions and interventions based on patients' conditions, and can collaborate with other smart devices to provide personalized care. This review discusses the concept of multi-agent systems, their application in pain management, and the potential challenges and countermeasures, aiming to provide guidance for the intelligent management of cancer patient pain.
4.Artificial intelligence in traditional Chinese medicine: from systems biological mechanism discovery, real-world clinical evidence inference to personalized clinical decision support.
Dengying YAN ; Qiguang ZHENG ; Kai CHANG ; Rui HUA ; Yiming LIU ; Jingyan XUE ; Zixin SHU ; Yunhui HU ; Pengcheng YANG ; Yu WEI ; Jidong LANG ; Haibin YU ; Xiaodong LI ; Runshun ZHANG ; Wenjia WANG ; Baoyan LIU ; Xuezhong ZHOU
Chinese Journal of Natural Medicines (English Ed.) 2025;23(11):1310-1328
Traditional Chinese medicine (TCM) represents a paradigmatic approach to personalized medicine, developed through the systematic accumulation and refinement of clinical empirical data over more than 2000 years, and now encompasses large-scale electronic medical records (EMR) and experimental molecular data. Artificial intelligence (AI) has demonstrated its utility in medicine through the development of various expert systems (e.g., MYCIN) since the 1970s. With the emergence of deep learning and large language models (LLMs), AI's potential in medicine shows considerable promise. Consequently, the integration of AI and TCM from both clinical and scientific perspectives presents a fundamental and promising research direction. This survey provides an insightful overview of TCM AI research, summarizing related research tasks from three perspectives: systems-level biological mechanism elucidation, real-world clinical evidence inference, and personalized clinical decision support. The review highlights representative AI methodologies alongside their applications in both TCM scientific inquiry and clinical practice. To critically assess the current state of the field, this work identifies major challenges and opportunities that constrain the development of robust research capabilities-particularly in the mechanistic understanding of TCM syndromes and herbal formulations, novel drug discovery, and the delivery of high-quality, patient-centered clinical care. The findings underscore that future advancements in AI-driven TCM research will rely on the development of high-quality, large-scale data repositories; the construction of comprehensive and domain-specific knowledge graphs (KGs); deeper insights into the biological mechanisms underpinning clinical efficacy; rigorous causal inference frameworks; and intelligent, personalized decision support systems.
Medicine, Chinese Traditional/methods*
;
Artificial Intelligence
;
Humans
;
Precision Medicine
;
Decision Support Systems, Clinical
5.Impact of digital fitting of orthokeratology on decentration and corneal aberration
Jun CAI ; Wenjia CAO ; Haoxi CHEN ; Jiaqian ZHANG ; Juanjuan WU ; Di SHEN ; Wei WEI
International Eye Science 2025;25(11):1893-1898
AIM: To investigate the decentration of the treatment zone(TZ)and the early impact on corneal higher-order aberrations(HOAs)induced by orthokeratology(OK)lenses fitted with digital corneal topography.METHODS: A retrospective longitudinal clinical study was conducted on 28 patients(28 right eyes)who were digitally fitted with OK lenses at the Laser Vision Center of Xi'an No.1 Hospital since 2023. Longitudinal measurements were taken at baseline, 1 wk, 1 and 3 mo post-treatment to assess changes in TZ diameter, decentration magnitude and direction. Furthermore, changes in corneal HOAs were observed, and correlations of decentration with each HOAs were also analyzed.RESULTS: The mean age of patients was 10.29±2.00 years, with 15 males and 13 females, and the average baseline spherical equivalent was -2.92±0.94 D. The average TZ diameters at 1 wk, 1, and 3 mo were 3.64±0.58, 3.83±0.57, and 3.69±0.55 mm, respectively, with no statistically significant differences between 1 wk and 3 mo. Horizontal decentration values were -0.43±0.28, -0.38±0.33, and -0.31±0.37 mm after wearing lenses for 1 wk, 1 and 3 mo, respectively, while vertical decentration values were -0.33±0.20, -0.33±0.23, and -0.36±0.23 mm across the same time points. The TZ consistently decentered inferotemporally, and changes in both horizontal and vertical decentration over time were not statistically significant(Fhorizontal=1.416, Phorizontal=0.252; Fvertical=0.126, Pvertical=0.882). Significant increases in total corneal HOAs, coma, and spherical aberration were observed at 5 mm optical zone post-wear(F=45.695, 33.401, and 45.091, all P<0.001). Vertical decentration at 1 wk and 1 mo was negatively correlated with total HOAs and coma(all P<0.05), while horizontal decentration at 3 mo showed a weak negative correlation with spherical aberration(P=0.037).CONCLUSION: Digitally-fitted OK lenses achieved stable TZ diameter by 1 wk post-wear, with minor inferotemporal decentration. Early post-wear corneal total HOAs, coma and sphercal aberration increased significantly, and vertical downward decentration was associated with elevated total HOAs and coma. However, correlations between decentration and HOAs weakened by 3 mo.
6.Evaluation of hemolysis quality of specimens by fully automated blood collection robot
Chong WANG ; Meixiu GU ; Jie ZHU ; Peiqi FANG ; Wenjia TANG ; Zizhong LIU ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Laboratory Medicine 2025;48(8):1080-1084
Objective:To compare the differences in specimen results between the intelligent robotic phlebotomy group and the manual venipuncture group, and to evaluate the clinical applicability of the autonomous blood collection system.Methods:From January 20 to October 28, 2022, 154 volunteers at Zhongshan Hospital, Fudan University underwent paired blood collections (robotic and manual) within 5 minutes. The collected samples were analyzed for: hemolysis index (HI), alanine transaminase (ALT), aspartate transaminase (AST), L-γ-glutamyltransferase (γ-GT), lactate dehydrogenase (LDH), urea nitrogen (UREA), creatinine (CRE), uric acid (UA), glucose (GLU), total cholesterol (TC), triglyceride (TG), natrium (Na), kalium (K), chlorine (Cl), creatine kinase (CK), CK-MB, CK-MM, and neuron-specific enolase (NSE). Statistical analyses used t-tests and Wilcoxon signed-rank tests.Results:The results of two different blood collection methods revealed that the HI values of 154 specimens in the intelligent robot blood collection group were all less than 20SI, while 7 specimens (4.54%) in the manual blood collection group had HI values exceeding 20SI; In the comparison of 17 biochemical and immunological markers, there were statistically significant differences between groups in 8 items including γ-GT[20.00(15.00, 37.75)U/L vs. 19.00 (14.00, 36.25)U/L, Z=2.497, P<0.05], LDH[165.5 (147.0, 183.0)U/L vs. 173.0 (155.0, 193.0)U/L, Z=8.629, P<0.05], TC[(5.002±0.856)mmol/L vs.(5.031±0.870) mmol/L, t=-3.006, P<0.05], K[4.1 (4.0, 4.3)mmol/L vs. 4.3 (4.1, 4.4)mmol/L, Z=5.592, P<0.05], CK[97.00 (73.00, 133.00)U/L vs. 99.00 (74.75, 136.25)U/L, Z=3.490, P<0.05], CK-MB[13 (11, 15)U/L vs. 14 (12, 16)U/L, Z=6.581, P<0.05], CK-MM[84.00 (60.00, 119.00)U/L vs. 83.50 (58.75, 118.00)U/L, Z=3.790, P<0.05], and NSE[10.600 (9.500, 11.700)ng/ml vs. 11.950 (10.475, 13.725)ng/ml, Z=8.151, P<0.05]. Conclusions:In the collection of serum samples, intelligent blood collection robots can achieve standardization and normalization of specimen collection volume and mixing in the pre-analysis stage. The hemolysis related indicators of the collected specimens are lower than those of the manual collection group, and can be used for the collection of clinical serological specimens.
7.Application progress of multi-agent systems in pain management for cancer patients
Mengxin HE ; Wenjia WEI ; Defeng CHEN ; Wanlin PENG ; Bei LI ; Xuhui DONG ; Jiabao LI ; Yang YANG
Chinese Journal of Modern Nursing 2025;31(2):266-270
Cancer patients often experience worsening pain due to the limitations of traditional pharmacological treatments. This paper explores the innovative application of multi-agent systems in this field. As a key component of artificial intelligence, multi-agent systems assist healthcare providers in making intelligent decisions and interventions based on patients' conditions, and can collaborate with other smart devices to provide personalized care. This review discusses the concept of multi-agent systems, their application in pain management, and the potential challenges and countermeasures, aiming to provide guidance for the intelligent management of cancer patient pain.
8.Evaluation of hemolysis quality of specimens by fully automated blood collection robot
Chong WANG ; Meixiu GU ; Jie ZHU ; Peiqi FANG ; Wenjia TANG ; Zizhong LIU ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Laboratory Medicine 2025;48(8):1080-1084
Objective:To compare the differences in specimen results between the intelligent robotic phlebotomy group and the manual venipuncture group, and to evaluate the clinical applicability of the autonomous blood collection system.Methods:From January 20 to October 28, 2022, 154 volunteers at Zhongshan Hospital, Fudan University underwent paired blood collections (robotic and manual) within 5 minutes. The collected samples were analyzed for: hemolysis index (HI), alanine transaminase (ALT), aspartate transaminase (AST), L-γ-glutamyltransferase (γ-GT), lactate dehydrogenase (LDH), urea nitrogen (UREA), creatinine (CRE), uric acid (UA), glucose (GLU), total cholesterol (TC), triglyceride (TG), natrium (Na), kalium (K), chlorine (Cl), creatine kinase (CK), CK-MB, CK-MM, and neuron-specific enolase (NSE). Statistical analyses used t-tests and Wilcoxon signed-rank tests.Results:The results of two different blood collection methods revealed that the HI values of 154 specimens in the intelligent robot blood collection group were all less than 20SI, while 7 specimens (4.54%) in the manual blood collection group had HI values exceeding 20SI; In the comparison of 17 biochemical and immunological markers, there were statistically significant differences between groups in 8 items including γ-GT[20.00(15.00, 37.75)U/L vs. 19.00 (14.00, 36.25)U/L, Z=2.497, P<0.05], LDH[165.5 (147.0, 183.0)U/L vs. 173.0 (155.0, 193.0)U/L, Z=8.629, P<0.05], TC[(5.002±0.856)mmol/L vs.(5.031±0.870) mmol/L, t=-3.006, P<0.05], K[4.1 (4.0, 4.3)mmol/L vs. 4.3 (4.1, 4.4)mmol/L, Z=5.592, P<0.05], CK[97.00 (73.00, 133.00)U/L vs. 99.00 (74.75, 136.25)U/L, Z=3.490, P<0.05], CK-MB[13 (11, 15)U/L vs. 14 (12, 16)U/L, Z=6.581, P<0.05], CK-MM[84.00 (60.00, 119.00)U/L vs. 83.50 (58.75, 118.00)U/L, Z=3.790, P<0.05], and NSE[10.600 (9.500, 11.700)ng/ml vs. 11.950 (10.475, 13.725)ng/ml, Z=8.151, P<0.05]. Conclusions:In the collection of serum samples, intelligent blood collection robots can achieve standardization and normalization of specimen collection volume and mixing in the pre-analysis stage. The hemolysis related indicators of the collected specimens are lower than those of the manual collection group, and can be used for the collection of clinical serological specimens.
9.Willingness and Factors Influencing the Dissemination of Health Knowledge among Healthcare Profession-als in Shanghai under the Background of"Breaking the Five-Only"
Dongsheng BIAN ; Fan ZHU ; Wei CHEN ; Wenjia TANG ; Guohong LI
Chinese Hospital Management 2024;44(1):42-46
Objective Under the background of"breaking the Five-Only"and the evaluation reform of healthcare professionals'titles,it analyzed the willingness of healthcare professionals in public hospitals to disseminate health knowledge and its incentives and constraints.Furthermore,it explored potential pathways to improve the willingness of healthcare professionals to popular science and disseminate health knowledge.Methods From November to Decem-ber 2022,a self-designed online questionnaire was used to survey healthcare professionals in four tertiary hospitals in Shanghai.The questionnaire included basic information of healthcare professionals,analysis of the current situa-tion and demands of healthcare professionals in health knowledge dissemination,willingness of healthcare profes-sionals to disseminate health knowledge and influencing factors.Results A total of 762 healthcare professionals partici-pated in this survey,79.9%(608/762)expressed willingness to promote the dissemination of health knowledge.A multiple-factor logistic regression analysis revealed that intermediate professional title,achieving personal value and so-cial responsibility,increasing patient resources,professional title promotion,science promotion-related awards,being included in performance appraisals,and difficulty in capturing science promotion skills were the influential factors affecting the dissemination of health knowledge among healthcare professionals(P<0.05).Conclusion The willing-ness of healthcare professionals to disseminate health knowledge was strong,and hospitals should motivate health-care professionals to disseminate health knowledge through building a long-term incentive mechanism,strengthening training in science popularization ability,and improving humanistic qualities.
10.Progress of peripheral defocus design framework eyeglasses in myopia control
Haoxi CHEN ; Di SHEN ; Jun CAI ; Xiyu SUN ; Wenjia CAO ; Mengchen LI ; Wei WEI
International Eye Science 2024;24(8):1275-1279
Myopia is becoming more and more common all over the world, and the incidence of myopia is gradually increasing. Many treatments have been used to prevent and control myopia, including optics, drugs, environment or behavior, but the results are different and lack standardization. At present, many experiments have proved that peripheral defocus technology has a certain effect on myopia control. Based on this technology, three kinds of framed eyeglass lenses with peripheral defocus design, namely defocus incorporated multiple segments(DIMS), highly aspherical lenslets(HAL)and cylindrical annular reactive elements(CARE), are commonly used in medical and optometry institutions in China. These lenses provide not only clear vision in the central area, but also a certain amount of myopic defocus in the periphery to control the progression of myopia. This paper aims to focus on the design principle and myopia prevention and control effect of the above three peripheral defocus lenses, and evaluate their effectiveness in clinical practice.

Result Analysis