1.Fabrication of sharp disordered vs.rounded ordered titanium surface micro-and nano-structures and e-valuation of their osteogenic capacity
Weiwei GUO ; Fuwei LIU ; Xu HE ; Jianye SONG ; Zuge YANG ; Wenhao YANG ; Yuncan MA ; Yun-peng LI ; Kun WANG
Journal of Practical Stomatology 2025;41(3):336-343
Objective:Micro-and nanostructures with sharp disordered and rounded ordered features were fabricated on titanium surfaces,respectively,and their osteogenic potential was evaluated both in vitro and in vivo.Methods:Sharp disordered titanium surfaces(SLA-Ti)and rounded ordered titanium surfaces(Laser-Ti)were prepared using sandblast acid etching and high-repeti-tion-rate femtosecond laser,respectively.Smooth titanium(Ti)was used as the control group,SLA-Ti and Laser-Ti were used as the experimental groups.Characterization was conducted using scanning electron microscopy coupled with hydrophilicity assess-ments.The adhesion,elongation,and osteogenic differentiation capabilities of osteoblasts in vitro were evaluated through cell mor-phology observations,cytoskeletal fluorescence staining,cell viability assays,and PCR experiments.Osteogenic potential in vivo of rabbits was assessed through Micro CT scans and histological staining(HE and Masson).Results:The surface of Laser-Ti exhibits a rounded,ordered,multi-scale micro-and nano-morphology with the best hydrophilicity(P<0.01).In vitro,it promotes cell adhe-sion,extension,and osteogenic differentiation,while in vivo,it enhances bone regeneration around the implants.Overall,a trend of Laser-Ti>SLA-Ti>Ti is observed,with a higher bone volume fraction(BV/TV)(P<0.05),greater trabecular thickness(Tb.Th)(P<0.05),an increased number of trabeculae(Tb.N)(P<0.05),and a larger area of bone around the implants(P<0.05).Conclusion:The rounded ordered micro-and nano-structures fabricated using high-repetition-rate fem-tosecond laser demonstrate enhanced osteoinductive capac-ity both in vitro and in vivo.
2.Fabrication of sharp disordered vs.rounded ordered titanium surface micro-and nano-structures and e-valuation of their osteogenic capacity
Weiwei GUO ; Fuwei LIU ; Xu HE ; Jianye SONG ; Zuge YANG ; Wenhao YANG ; Yuncan MA ; Yun-peng LI ; Kun WANG
Journal of Practical Stomatology 2025;41(3):336-343
Objective:Micro-and nanostructures with sharp disordered and rounded ordered features were fabricated on titanium surfaces,respectively,and their osteogenic potential was evaluated both in vitro and in vivo.Methods:Sharp disordered titanium surfaces(SLA-Ti)and rounded ordered titanium surfaces(Laser-Ti)were prepared using sandblast acid etching and high-repeti-tion-rate femtosecond laser,respectively.Smooth titanium(Ti)was used as the control group,SLA-Ti and Laser-Ti were used as the experimental groups.Characterization was conducted using scanning electron microscopy coupled with hydrophilicity assess-ments.The adhesion,elongation,and osteogenic differentiation capabilities of osteoblasts in vitro were evaluated through cell mor-phology observations,cytoskeletal fluorescence staining,cell viability assays,and PCR experiments.Osteogenic potential in vivo of rabbits was assessed through Micro CT scans and histological staining(HE and Masson).Results:The surface of Laser-Ti exhibits a rounded,ordered,multi-scale micro-and nano-morphology with the best hydrophilicity(P<0.01).In vitro,it promotes cell adhe-sion,extension,and osteogenic differentiation,while in vivo,it enhances bone regeneration around the implants.Overall,a trend of Laser-Ti>SLA-Ti>Ti is observed,with a higher bone volume fraction(BV/TV)(P<0.05),greater trabecular thickness(Tb.Th)(P<0.05),an increased number of trabeculae(Tb.N)(P<0.05),and a larger area of bone around the implants(P<0.05).Conclusion:The rounded ordered micro-and nano-structures fabricated using high-repetition-rate fem-tosecond laser demonstrate enhanced osteoinductive capac-ity both in vitro and in vivo.
3.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
4.Progress on early screening and recognition of fragile X syndrome
Wenhao LI ; Lingling WU ; Chao SONG
International Journal of Pediatrics 2024;51(3):159-163
Fragile X syndrome(FXS)is one of the most common single-gene disorders that cause intellectual disability and autism spectrum disorders. It is characterized by a complex phenotype and clinical heterogeneity,which poses challenges for early diagnosis. The number of potential FXS patients is large,and many of them face the dilemma of under-diagnosis or even misdiagnosis. This paper provides an overview of current screening and early identification methods and models for FXS,encompassing population-based screening approaches as well as individual clinical phenotype-based identification strategies. These finding 's offer valuable support for clinical practice,mass screening and disease management. Furthermore,advancements in genetic engineering and artificial intelligence technology hold promise to revolutionize FXS screening and early identification.
5.Effects of carbamazepine on BDNF expression in trigeminal ganglia and serum in rats with trigeminal neuralgia
Yufeng SONG ; Min ZHOU ; Jiawen XIONG ; Ruoyu HUANG ; Wenhao SHEN ; Ting ZHAN ; Yuting XIE ; Yun GAO ; Wei XIONG
Journal of Central South University(Medical Sciences) 2024;49(1):11-20
Objective:Trigeminal neuralgia(TN)is a severe chronic neuropathic pain that mainly affects the distribution area of the trigeminal nerve with limited treating efficacy.There are numerous treatments for TN,but currently the main clinical approach is to suppress pain by carbamazepine(CBZ).Brain-derived neurotrophic factor(BDNF)is closely related to chronic pain.This study aims to determine the effects of CBZ treatment on BDNF expression in both the trigeminal ganglion(TG)and serum of TN via a chronic constriction injury of the infraorbital nerve(ION-CCI)rat model. Methods:The ION-CCI models were established in male Sprague-Dawley rats and were randomly divided into a sham group,a TN group,a TN+low-dose CBZ treatment group(TN+20 mg/kg CBZ group),a TN+medium-dose CBZ treatment group(TN+40 mg/kg CBZ group),and a TN+high-dose CBZ treatment group(TN+80 mg/kg CBZ group).The mechanical pain threshold in each group of rats was measured regularly before and after surgery.The expressions of BDNF and tyrosine kinase receptor B(TrkB)mRNA in TGs of rats in different groups were determined by real-time PCR,and the expression of BDNF protein on neurons in TGs was observed by immunofluorescence.Western Blotting was used to detect the protein expression of BDNF,TrkB,extracellular regulated protein kinases(ERK),and phospho-extracellular regulated protein kinases(p-ERK)in TGs of rats in different groups.The expression of BDNF in the serum of rats in different groups was detected by enzyme-linked immunosorbent assay(ELISA). Results:The results of mechanical pain sensitivity showed that there was no significant difference in the mechanical pain threshold in the right facial sensory area of the experimental rats in each group before surgery(all P>0.05).From the 3rd day after operation,the mechanical pain threshold of rats in the TN group was significantly lower than that in the sham group(all P<0.01),and the mechanical pain threshold of rats in the TN+80 mg/kg CBZ group,the TN+40 mg/kg CBZ group,and the TN+20 CBZ mg/kg group was higher than that in the TN group(all P<0.05).The BDNF and TrkB mRNA and protein expressions in TGs of rats in the TN group were higher than those in the sham group(all P<0.05),and those in the TN+80 mg/kg CBZ group,the TN+40 mg/kg CBZ group,and the TN+20 mg/kg CBZ group were lower than the TN group(all P<0.05).The p-ERK levels in TG of rats in the TN+80 mg/kg CBZ group,the TN+40 mg/kg CBZ group,and the TN+20 mg/kg CBZ group were significantly decreased compared with the TN group(all P<0.05).The BDNF and neuron-specific nuclear protein(NeuN)were mainly co-expressed in neuron of TGs in the TN group and they were significantly higher than those in the sham group(all P<0.05).The co-labeled expressions of BDNF and NeuN in TGs of the TN+ 80 mg/kg CBZ group,the TN+40 mg/kg CBZ group,and the TN+20 mg/kg CBZ group were lower than those in the TN group(all P<0.05).The results of ELISA showed that the level of BDNF in the serum of the TN group was significantly higher than that in the sham group(P<0.05).The levels of BDNF in the TN+80 mg/kg CBZ group,the TN+40 mg/kg CBZ group,and the TN+20 mg/kg CBZ group were lower than those in the TN group(all P<0.05).Spearman correlation analysis showed that the BDNF level in serum was negatively correlated with mechanical pain threshold(r=-0.650,P<0.01). Conclusion:CBZ treatment can inhibit the expression of BDNF and TrkB in the TGs of TN rats,reduce the level of BDNF in serum of TN rats and the phosphorylation of ERK signaling pathway,so as to inhibit TN.The serum level of BDNF can be considered as an indicator for the diagnosis and prognosis of TN.
6.Value of synthetic MRI in the differential diagnosis of parotid gland tumors
Zanxia ZHANG ; Shujian LI ; Yong ZHANG ; Weijian WANG ; Manli SONG ; Wenhao WANG ; Baohong WEN ; Jingliang CHENG
Journal of Practical Radiology 2024;40(3):361-364
Objective To investigate the application value of quantitative relaxation parameters based on synthetic MRI technology in the differential diagnosis of parotid gland tumors.Methods Conventional MRI and synthetic MRI data of 59 patients with patho-logically confirmed parotid gland tumors were analyzed retrospectively.T1,T2,and proton density(PD)values of the tumor were extracted from T1,T2 and PD mapping.The differences in quantitative relaxation parameters of pleomorphic adenomas,Warthin tumors,and malignant tumors were further compared.Diagnostic performance of each quantitative relaxation parameter was assessed and com-pared via receiver operating characteristic(ROC)curve and DeLong test.Results T2 value was significantly higher in pleomorphic adenomas than that in malignant tumors(P<0.05).The T1,T2,and PD values of pleomorphic adenomas and malignant tumors were significantly higher than those of Warthin tumors(P<0.05).The area under the curve(AUC)of the T2 value in differentia-ting pleomorphic adenomas from malignant tumors was 0.794.The AUC for T1 value(0.939)in differentiating Warthin tumors from malignant tumors was significantly higher than that of T2(0.873,P=0.341)and PD(0.927,P=0.891)values,without sta-tistically significant difference.The AUC for T2 value(0.968)in differentiating pleomorphic adenomas from Warthin tumors was significantly higher than that of T1(0.931,P=0.360)and PD(0.876,P=0.120)values,without statistically significant difference.Conclusion Quantitative relaxation parameters based on synthetic MRI technology may contribute to differentiating pleomorphic adenomas,Warthin tumors,and malignant tumors of the parotid gland.
7.The Correlation between Tooth Brushing Frequency and Blood Indicators in Adolescents: A Cross-sectional Observational Study
Xu ZHANG ; Hanze DU ; Wenhao ZHAI ; Shuaihua SONG ; Xiaoyuan GUO ; Linlin WEN ; Lei HUANG ; Shi CHEN ; Daowei LI ; Hui PAN
Medical Journal of Peking Union Medical College Hospital 2024;15(4):960-967
To analyze the effects of tooth brushing frequency on blood indicators among adolescents and to preliminarily explore the effects of tooth brushing frequency on general health. Using convenience sampling method, the study included the students of class 2021 of Jining No. 7 Middle School and student athletes from the Jining Sports Training Center. Univariate and multivariate linear regression analyses were used to investigate the correlation between tooth brushing frequency and blood indicators such as eosinophil percentage (EOS%), eosinophil count (EOS#), basophil percentage (BAS%), basophil count (BAS#), superoxide dismutase (SOD), insulin-like growth factor 1 (IGF-1) and uric acid (UA). A total of 305 students were included (167 from Jining No. 7 Middle School, 138 from Jining Sports Training Centre), with 192 (62.95%) males and 113 (37.05%) females. They were divided into three groups based on daily teeth brushing frequency: ≤1 time (40.33%, 123/305), 2 times (53.77%, 164/305), and ≥3 times (5.90%, 18/305).Univariate linear regression analysis showed that brushing twice daily was negatively correlated with EOS%, EOS#, BAS%, and BAS#(all The adolescent tooth brushing frequency correlates with several blood indicators affecting general health, suggesting that there may be a potential association between oral health and general health.
8.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
9.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
10.A review of research advances in virtual reality-based interventions for children with autism
Yu FANG ; Wenhao LIN ; Xiaohua SUN ; Yuan ZHAO ; Liying DONG ; Haidong SONG
Chinese Mental Health Journal 2024;38(5):394-399
This paper analyzes the literature on virtual reality(VR)technology interventions for autistic children published from 2014 to 2022.It shows that different VR systems in these studies have improved different symptoms of autism,and points out the feasibility of VR technology interventions for autistic children.

Result Analysis
Print
Save
E-mail