1.A review of research advances in virtual reality-based interventions for children with autism
Yu FANG ; Wenhao LIN ; Xiaohua SUN ; Yuan ZHAO ; Liying DONG ; Haidong SONG
Chinese Mental Health Journal 2024;38(5):394-399
This paper analyzes the literature on virtual reality(VR)technology interventions for autistic children published from 2014 to 2022.It shows that different VR systems in these studies have improved different symptoms of autism,and points out the feasibility of VR technology interventions for autistic children.
2.Relationship among sleep quality,perceived stress,ego depletion,and mindfulness in police officers
Chinese Mental Health Journal 2024;38(7):611-617
Objective:To explore the relationship between sleep quality and perceived stress and analyze the role of ego depletion and mindfulness in their relationship.Methods:Totally 326 police officers were selected and assessed with the Pittsburgh Sleep Quality Index(PSQI),Chinese Perceived Stress Scale(CPSS),Brief Ego Deple-tion Scale(BEDS),and Mindful Attention Awareness Scale(MAAS).Results:The average PSQI score was(9.1±3.0).There was a partial mediation effect between CPSS scores and PSQI scores,and the mediation effect ac-counted for 27.03%.The MAAS scores were regulated between CPSS scores and BEDS scores(β=-0.01,P<0.01),CPSS scores and PSQI scores(β=-0.01,P<0.001),and BEDS scores and PSQI scores(β=-0.02,P<0.01).Conclusion:The sleep quality of the police officers is related to perceived stress,and ego depletion plays a mediating role between them,and mindfulness acts as a protective factor in the whole process.
3.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
4.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
5.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
6.Progress on early screening and recognition of fragile X syndrome
Wenhao LI ; Lingling WU ; Chao SONG
International Journal of Pediatrics 2024;51(3):159-163
Fragile X syndrome(FXS)is one of the most common single-gene disorders that cause intellectual disability and autism spectrum disorders. It is characterized by a complex phenotype and clinical heterogeneity,which poses challenges for early diagnosis. The number of potential FXS patients is large,and many of them face the dilemma of under-diagnosis or even misdiagnosis. This paper provides an overview of current screening and early identification methods and models for FXS,encompassing population-based screening approaches as well as individual clinical phenotype-based identification strategies. These finding 's offer valuable support for clinical practice,mass screening and disease management. Furthermore,advancements in genetic engineering and artificial intelligence technology hold promise to revolutionize FXS screening and early identification.
7.Value of synthetic MRI in the differential diagnosis of parotid gland tumors
Zanxia ZHANG ; Shujian LI ; Yong ZHANG ; Weijian WANG ; Manli SONG ; Wenhao WANG ; Baohong WEN ; Jingliang CHENG
Journal of Practical Radiology 2024;40(3):361-364
Objective To investigate the application value of quantitative relaxation parameters based on synthetic MRI technology in the differential diagnosis of parotid gland tumors.Methods Conventional MRI and synthetic MRI data of 59 patients with patho-logically confirmed parotid gland tumors were analyzed retrospectively.T1,T2,and proton density(PD)values of the tumor were extracted from T1,T2 and PD mapping.The differences in quantitative relaxation parameters of pleomorphic adenomas,Warthin tumors,and malignant tumors were further compared.Diagnostic performance of each quantitative relaxation parameter was assessed and com-pared via receiver operating characteristic(ROC)curve and DeLong test.Results T2 value was significantly higher in pleomorphic adenomas than that in malignant tumors(P<0.05).The T1,T2,and PD values of pleomorphic adenomas and malignant tumors were significantly higher than those of Warthin tumors(P<0.05).The area under the curve(AUC)of the T2 value in differentia-ting pleomorphic adenomas from malignant tumors was 0.794.The AUC for T1 value(0.939)in differentiating Warthin tumors from malignant tumors was significantly higher than that of T2(0.873,P=0.341)and PD(0.927,P=0.891)values,without sta-tistically significant difference.The AUC for T2 value(0.968)in differentiating pleomorphic adenomas from Warthin tumors was significantly higher than that of T1(0.931,P=0.360)and PD(0.876,P=0.120)values,without statistically significant difference.Conclusion Quantitative relaxation parameters based on synthetic MRI technology may contribute to differentiating pleomorphic adenomas,Warthin tumors,and malignant tumors of the parotid gland.
8.Application of Chimney technique in mitral valve reoperation: A retrospective study in a single center
Wenhao LIU ; Laichun SONG ; Mingyuan YANG ; Jingcheng WU ; Liang TAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(05):757-761
Objective To investigate and evaluate the safety and effectiveness of the Chimney technique in mitral valve reoperation. Methods The clinical data of mitral valve reoperation patients who underwent Chimney surgery in Wuhan Asia Heart Hospital from 2019 to 2021 were retrospectively analyzed. Results A total of 26 patients were collected, including 7 males and 19 females, aged 27-67 (53.46±11.18) years. All patients had previous mitral valve surgery, including 23 mitral valve replacements and 3 mitral valve repairs. All patients received Chimney technique using the ideal artificial sized mitral valve, and 1 patient died of neurological complications in hospital. The cardiopulmonary bypass time and the aortic cross-clamping time were 231.11±77.05 min and 148.50±52.70 min, respectively. The mean diameter of the implanted mitral valve prosthesis was 29.08±0.68 mm, which was statistically different from pre-replacement valve prosthesis size of 26.69±0.77 mm (P<0.001). The mean transvalvular pressure gradient of the prosthetic mitral valve measured on postoperative echocardiography was 14.77±5.34 mm Hg, which was statistically different from preoperative value of 20.92±9.83 mm Hg (P=0.005). Conclusion The Chimney technique is safe and effective for reoperation in patients with small mitral annuli, which can not only reduce the risk of reoperation, but also obtain larger prosthetic valve implants with good hemodynamic characteristics and clinical outcomes.
9.Aortic-mitral annular enlargement technique in re-valve surgery: A retrospective study in a single center
Mingyuan YANG ; Wenhao LIU ; Laichun SONG ; Jingcheng WU ; Liang TAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(06):826-831
Objective To investigate and evaluate the safety and efficacy of the aortic-mitral annular enlargement technique (double annular enlargement) in patients with small-size valve prostheses after prior valve surgery. Methods The clinical data of patients who underwent double valve annular enlargement in Wuhan Asia Heart Hospital from April 2020 to April 2022 were retrospectively analyzed. Results A total of 30 patients were collected, including 2 males and 28 females aged 9-78 (52.71±3.53) years. All patients had previous heart valve surgery, including 1 patient receiving the third heart surgery. All patients were operated on successfully and there were no postoperative in-hospital deaths. There was no postoperative bleeding which needed a secondary open-chest hemostasis, and one patient underwent permanent pacemaker implantation due to postoperative sick sinus syndrome. The mean diameter of the implanted prosthetic aortic valve was 24.23±1.60 mm, which was significantly larger than that of the preoperative aortic valve (21.03±1.90 mm, P<0.001). The mean diameter of the implanted prosthetic mitral valve was 28.33±1.21 mm, which was significantly larger than that of the preoperative mitral valve (25.43±0.84 mm, P<0.001). The mean peak gradient difference across the prosthetic aortic valve on postoperative echocardiography was 18.17±6.44 mm Hg, which was significantly lower than that of the preoperative aortic valve (82.57±24.48 mm Hg, P<0.001). The mean peak gradient difference of the postoperative prosthetic mitral valve was 12.73±5.45 mm Hg, which was significantly lower than that of the preoperative mitral valve (19.43±8.97 mm Hg, P=0.003). Conclusion The double annular enlargement technique is safe and effective for reoperation in patients with a history of valve surgery with a small aortic root to obtain both a larger size prosthetic valve for a larger orifice area and stability of the mitral-aortic valve union, resulting in good postoperative hemodynamic characteristics and clinical outcomes.
10.The Correlation between Tooth Brushing Frequency and Blood Indicators in Adolescents: A Cross-sectional Observational Study
Xu ZHANG ; Hanze DU ; Wenhao ZHAI ; Shuaihua SONG ; Xiaoyuan GUO ; Linlin WEN ; Lei HUANG ; Shi CHEN ; Daowei LI ; Hui PAN
Medical Journal of Peking Union Medical College Hospital 2024;15(4):960-967
To analyze the effects of tooth brushing frequency on blood indicators among adolescents and to preliminarily explore the effects of tooth brushing frequency on general health. Using convenience sampling method, the study included the students of class 2021 of Jining No. 7 Middle School and student athletes from the Jining Sports Training Center. Univariate and multivariate linear regression analyses were used to investigate the correlation between tooth brushing frequency and blood indicators such as eosinophil percentage (EOS%), eosinophil count (EOS#), basophil percentage (BAS%), basophil count (BAS#), superoxide dismutase (SOD), insulin-like growth factor 1 (IGF-1) and uric acid (UA). A total of 305 students were included (167 from Jining No. 7 Middle School, 138 from Jining Sports Training Centre), with 192 (62.95%) males and 113 (37.05%) females. They were divided into three groups based on daily teeth brushing frequency: ≤1 time (40.33%, 123/305), 2 times (53.77%, 164/305), and ≥3 times (5.90%, 18/305).Univariate linear regression analysis showed that brushing twice daily was negatively correlated with EOS%, EOS#, BAS%, and BAS#(all The adolescent tooth brushing frequency correlates with several blood indicators affecting general health, suggesting that there may be a potential association between oral health and general health.

Result Analysis
Print
Save
E-mail