1.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
2.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
3.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
4.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
5.Evaluation method and system for aging effects of autonomic nervous system based on cross-wavelet transform cardiopulmonary coupling.
Juntong LYU ; Yining WANG ; Wenbin SHI ; Pengyan TAO ; Jianhong YE
Journal of Biomedical Engineering 2025;42(4):748-756
Heart rate variability time and frequency indices are widely used in functional assessment for autonomic nervous system (ANS). However, this method merely analyzes the effect of cardiac dynamics, overlooking the effect of cardio-pulmonary interplays. Given this, the present study proposes a novel cardiopulmonary coupling (CPC) algorithm based on cross-wavelet transform to quantify cardio-pulmonary interactions, and establish an assessment system for ANS aging effects using wearable electrocardiogram (ECG) and respiratory monitoring devices. To validate the superiority of the proposed method under nonstationary and low signal-to-noise ratio conditions, simulations were first conducted to demonstrate the performance strength of the proposed method to the traditional one. Next, the proposed CPC algorithm was applied to analyze cardiac and respiratory data from both elderly and young populations, revealing that young populations exhibited significantly stronger couplings in the high-frequency band compared with their elderly counterparts. Finally, a CPC assessment system was constructed by integrating wearable devices, and additional recordings from both elderly and young populations were collected by using the system, completing the validation and application of the aging effect assessment algorithm and the wearable system. In conclusion, this study may offers methodological and system support for assessing the aging effects on the ANS.
Humans
;
Autonomic Nervous System/physiology*
;
Algorithms
;
Aging/physiology*
;
Electrocardiography/methods*
;
Heart Rate/physiology*
;
Wavelet Analysis
;
Aged
;
Signal Processing, Computer-Assisted
;
Wearable Electronic Devices
6.Short-term effectiveness of Gamma 3 U-Blade system for osteoporotic intertrochanteric fractures in the elderly.
Wenbin FAN ; Liu SHI ; Tian XIE ; Cheng ZHANG ; Xiangxu CHEN ; Hui CHEN ; Yunfeng RUI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):47-52
OBJECTIVE:
To compare the short-term effectiveness between Gamma 3 intramedullary nails and Gamma 3 U-Blade system in the treatment of osteoporotic intertrochanteric fractures in the elderly.
METHODS:
A retrospective analysis was conducted on the clinical data of 124 elderly patients with osteoporotic intertrochanteric fractures, who were admitted between February 2020 and February 2023 and met the selection criteria. The fractures were fixed with Gamma 3 intramedullary nails in 65 patients (control group) and Gamma 3 U-Blade systems in 59 patients (UB group). The differences between the two groups were not significant in age, gender, body mass index, American Society of Anesthesiologists (ASA) classification, bone mineral density, time from injury to operation, fracture classification, and affected side ( P>0.05). The operation time, intraoperative blood loss, hospital stay, and fracture healing time were recorded; the tip-apex distance, fracture reduction quality, and lag screw position were evaluated on X-ray films at immediate after operation; the lag screw sliding distance and change value of neck-shaft angle were measured on X-ray films at last follow-up. Harris hip score at 1 year after operation and the occurrence of internal fixation-related complications were compared between the two groups.
RESULTS:
The operation time, intraoperative blood loss, and hospital stay in the UB group increased compared to the control group, but the differences were not significant ( P>0.05). All patients in both groups were followed up 12-24 months (mean, 17.1 months). At 12 months after operation, there was no significant difference in the Harris hip score between the two groups ( P<0.05). Radiological examination showed that there was no significant difference between the two groups ( P>0.05) in terms of tip-apex distance, fracture reduction quality, and lag screw position. Fractures healed in both groups, and there was no significant difference in healing time ( P>0.05). At last follow-up, the change value of neck-shaft angle and lag screw sliding distance in the UB group were significantly lower than those in the control group ( P<0.05). During follow-up, no related complications occurred in the UB group, while 6 cases (9.2%) in the control group experienced complications, and the difference in the incidence was significant ( P<0.05).
CONCLUSION
For the osteoporotic intertrochanteric fractures in the elderly, the Gamma 3 U-Blade system fixation can achieve good short-term effectiveness, with better imaging results compared to Gamma 3 intramedullary nails fixation.
Humans
;
Retrospective Studies
;
Hip Fractures/surgery*
;
Male
;
Female
;
Aged
;
Fracture Fixation, Intramedullary/methods*
;
Osteoporotic Fractures/surgery*
;
Bone Nails
;
Bone Screws
;
Aged, 80 and over
;
Treatment Outcome
;
Fracture Healing
;
Operative Time
;
Length of Stay
7.Trends in burden of pelvic fractures from 1990 to 2023 and long short-term memory-based insights into future projections.
Wenbin FAN ; Yueheng YIN ; Chuwei TIAN ; Jun ZHOU ; Tian XIE ; Liu SHI ; Guodong LIU ; Yunfeng RUI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1371-1380
OBJECTIVE:
To analyze the disease burden of pelvic fractures at the global, regional, and national levels from 1990 to 2023 using data from the 2023 Global Burden of Disease Study (GBD), and to predict the disease burden through 2050.
METHODS:
Leveraging data from the GBD 2023, this study investigated the disease burden of pelvic fractures across 204 countries and regions. Assessment indicators included incidence rate, prevalence rate, and years lived with disability (YLDs). The Joinpoint regression model was employed to analyze trends in pelvic fracture burden from 1990 to 2023, while the average annual percentage change (AAPC) was used to quantify this temporal trend. The relationship between the socio-demographic index and pelvic fracture burden was evaluated. Furthermore, the long short-term memory (LSTM) model was applied to predict trends in pelvic fracture burden through 2050.
RESULTS:
In 2023, the estimated number of new pelvic fracture cases globally was 7 479 884 [95% uncertainty interval ( UI): 5 293 401-10 611 876], representing a 42.74% increase from 1990. In the same year, the number of prevalent pelvic fracture cases and YLDs were 23 007 508 (95% UI: 21 021 518-25 327 165) and 3 909 228 person-years (95% UI: 2 725 498-5 194 385), respectively. Additionally, age-standardized rates exhibited an opposing downward trend. Significant disparities in the disease burden of pelvic fractures were identified across different age groups, genders, and social contexts. According to predictions from the LSTM model, the global age-standardized incidence rate (ASIR) of pelvic fractures will be approximately 88.44 per 100 000 persons by 2050, while the total number of incident cases will rise to 8 547 095.
CONCLUSION
Although the overall incidence rate, prevalence rate, and YLDs of pelvic fractures have exhibited an upward trend over the past three decades, the ASIR, age-standardized prevalence rate (ASPR), and age-standardized years of life lost rate (ASYR) have shown a downward trend. It is predicted that over the upcoming 26-year period, the age-standardized rate of disease burden due to pelvic fractures will further decrease, while the number of incident cases and prevalent cases will continue to exhibit an upward trend. Formulating more targeted disease prevention strategies is critical to addressing disparities across genders, regions, and other dimensions, and to mitigating the burden of pelvic fractures.
Humans
;
Fractures, Bone/epidemiology*
;
Pelvic Bones/injuries*
;
Male
;
Female
;
Middle Aged
;
Adult
;
Incidence
;
Prevalence
;
Aged
;
Global Burden of Disease/trends*
;
Global Health
;
Adolescent
;
Cost of Illness
;
Young Adult
;
Forecasting
;
Disability-Adjusted Life Years
;
Memory, Short-Term
8.Reversing metabolic reprogramming by CPT1 inhibition with etomoxir promotes cardiomyocyte proliferation and heart regeneration via DUSP1 ADP-ribosylation-mediated p38 MAPK phosphorylation.
Luxun TANG ; Yu SHI ; Qiao LIAO ; Feng WANG ; Hao WU ; Hongmei REN ; Xuemei WANG ; Wenbin FU ; Jialing SHOU ; Wei Eric WANG ; Pedro A JOSE ; Yongjian YANG ; Chunyu ZENG
Acta Pharmaceutica Sinica B 2025;15(1):256-277
The neonatal mammalian heart has a remarkable regenerative capacity, while the adult heart has difficulty to regenerate. A metabolic reprogramming from glycolysis to fatty acid oxidation occurs along with the loss of cardiomyocyte proliferative capacity shortly after birth. In this study, we sought to determine if and how metabolic reprogramming regulates cardiomyocyte proliferation. Reversing metabolic reprogramming by carnitine palmitoyltransferase 1 (CPT1) inhibition, using cardiac-specific Cpt1a and Cpt1b knockout mice promoted cardiomyocyte proliferation and improved cardiac function post-myocardial infarction. The inhibition of CPT1 is of pharmacological significance because those protective effects were replicated by etomoxir, a CPT1 inhibitor. CPT1 inhibition, by decreasing poly(ADP-ribose) polymerase 1 expression, reduced ADP-ribosylation of dual-specificity phosphatase 1 in cardiomyocytes, leading to decreased p38 MAPK phosphorylation, and stimulation of cardiomyocyte proliferation. Our present study indicates that reversing metabolic reprogramming is an effective strategy to stimulate adult cardiomyocyte proliferation. CPT1 is a potential therapeutic target for promoting heart regeneration and myocardial infarction treatment.
9.Altered serum metabolic profile in patients with autoimmune gastritis compared to other chronic gastritis.
Jihua SHI ; Yang ZHANG ; Yiran WANG ; Yuxi HUANG ; Zhe CHEN ; Xue XU ; Wenbin LI ; Dan CHEN ; Hao LUO ; Qingfeng LUO ; Ruiyue YANG ; Xue QIAO
Journal of Pharmaceutical Analysis 2025;15(5):101104-101104
Image 1.
10.Measurement and characterization of retinal vascular morphology parameters based on artificial intelligence automated analysis technology
Xuhan SHI ; Li DONG ; Lei SHAO ; Saiguang LING ; Zhou DONG ; Ying NIU ; Ruiheng ZHANG ; Wenda ZHOU ; Wenbin WEI
Chinese Journal of Experimental Ophthalmology 2024;42(1):38-46
Objective:To analyze retinal vascular parameters and distribution characteristics in Chinese population via the fully automated quantitative measurement of retinal vascular morphological parameters based on artificial intelligence technology.Methods:A cross-sectional study was performed.A total of 1 842 patients without fundus diseases who visited Beijing Tongren Hospital from January 2011 to December 2021 were included.Standardized questionnaires, blood draws and ophthalmologic examinations of enrolled subjects were conducted.Color fundus photographs centered on the optic disk of one eye of patients were collected, and a deep learning-based semantic segmentation network ResNet101-Unet was used to construct a vascular segmentation model for fully automated quantitative measurement of retinal vascular parameters.The main measurement indexes included retinal vascular branching angle, vascular fractal dimension, average vascular caliber, and average vascular tortuosity.To compare different retinal parameters between sexes, the correlation between the above parameters and ocular factors such as best corrected visual acuity, intraocular pressure, and axial length, as well as systemic factors such as sex, age, hypertension, diabetes mellitus, and cardiovascular disease was analyzed.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Beijing Tongren Hospital, Capital Medical University (No.20001220). Written informed consent was obtained from each subject.Results:The model established in this study achieved an accuracy over 0.95 for both vascular and optic disk segmentation.The vascular branching angle, vascular fractal dimension, average vascular caliber, and average vascular tortuosity were (51.023±11.623)°, 1.573(1.542, 1.592), 64.124(60.814, 69.053)μm, (0.001 062±0.000 165)°, respectively.Compared with females, males had larger vascular branching angle, smaller average vascular caliber and smaller vascular tortuosity, and the differences were statistically significant (all at P<0.05). The average vascular caliber increased by 1.142 μm in people with cardiovascular disease compared to people without cardiovascular disease ( B=1.142, P=0.029, 95% CI: 0.116-2.167). The average vascular tortuosity was positively correlated with hypertension ( B=3.053×10 -5, P=0.002, 95% CI: 1.167×10 -5-4.934×10 -5) and alcohol consumption ( B=1.036×10 -5, P=0.014, 95% CI: 0.211×10 -5-1.860×10 -5) and negatively correlated with hyperlipidemia ( B=-2.422×10 -5, P=0.015, 95% CI: -4.382×10 -5-0.462×10 -5). For each 1-mm increase in axial length, there was a decrease of 0.004 in vessel fractal dimension ( B=-0.004, P<0.001, 95% CI: -0.006--0.002), a decrease of 0.266 μm in the average vessel caliber ( B=-0.266, P=0.037, 95% CI: -0.516--0.016), and a decrease of -2.45×10 -5° in the average vessel tortuosity ( B=-2.45×10 -5, P<0.001, 95% CI: -0.313×10 -5--0.177×10 -5). For each 1.0 increase in BCVA, there was an increase of 3.992° in the vascular branch angle ( B=3.992, P=0.004, 95% CI: 1.283-6.702), an increase of 0.090 in vascular fractal dimension ( B=0.090, P<0.001, 95% CI: 0.078-0.102) and a decrease of 14.813 μm in the average vascular diameter ( B=-14.813, P<0.001, 95% CI: -16.474--13.153). Conclusions:A model for retinal vascular segmentation is successfully constructed.Retinal vessel parameters are associated with sex, age, systemic diseases, and ocular factors.

Result Analysis
Print
Save
E-mail