1.Construction and efficacy verification of an intelligent pharmaceutical Q&A platform based on AI hallucination-suppression
Zhengwang WEN ; Jiaying WANG ; Wenyue YANG ; Haoyu YANG ; Xiao MA ; Yun LIU
China Pharmacy 2026;37(2):226-231
OBJECTIVE To construct an intelligent pharmaceutical Q&A platform for precision medication with low “artificial intelligence (AI) hallucination”, aiming to enhance the accuracy, consistency, and traceability of medication consultations. METHODS Medication package inserts were batch-processed and converted into structured data through Python programming to build a local pharmaceutical knowledge base. The retrieval and question-answering processes were designed based on large language models, and system integration and localized deployment were completed on Dify platform. By designing typical clinical medication questions and comparing the output of the intelligent pharmaceutical Q&A platform with the online version of DeepSeek across dimensions such as peak time retrieval, half-life, and dosage adjustment reasoning for patients with renal impairment, the accuracy and reliability of its retrieval and reasoning results were evaluated. RESULTS The intelligent pharmaceutical Q&A platform, constructed based on local drug package inserts, achieved 100% accuracy in retrieval and reasoning for peak time, half-life, and dosage adjustment schemes. In comparison, the online version of DeepSeek demonstrated accuracies of 30%(6/20), 50%(10/20), and 38%(23/60) across these three dimensions, respectively. CONCLUSIONS The constructed intelligent pharmaceutical Q&A platform is capable of accurately retrieving and extracting information from the local knowledge base based on clinical inquiries, thereby avoiding the occurrence of AI hallucinations and providing reliable medication decision support for healthcare professionals.
2.Fluorescence Suppression Method of Raman Spectroscopy and Its Application in Skin and Cosmetics Analysis
Yun-Xia CHEN ; Jia-Rong WANG ; Jian-Yu ZHU ; Shi-Wen LIN ; Ya-Nan LIU ; Xiao-Yue MA ; Guang-Cheng XI ; Juan LIU
Progress in Biochemistry and Biophysics 2026;53(7):1914-1926
Owing to its inherent advantages—such as being non-destructive, rapid, highly molecule-specific, and minimally interfered with by moisture—Raman spectroscopy has been widely adopted in the fields of skin barrier function assessment, monitoring the transdermal penetration of active cosmetic ingredients, and the identification and quality control of cosmetic products. Despite these strengths, the practical application of this technique faces a significant bottleneck: the strong fluorescence background generated by endogenous skin components and exogenous cosmetic additives. Endogenous skin substances, such as structural proteins (e.g., collagen and elastin), metabolic coenzymes (e.g., nicotinamide adenine dinucleotide), and pigments (e.g., melanin), together with exogenous cosmetic constituents like organic colorants, chemical sunscreens, and fragrances, often possess strong absorption and emission characteristics. When excited by lasers, these components produce a fluorescence background that can be 106 to 108 times stronger than the Raman scattering signals, effectively masking the inherently weak vibrational fingerprint information. In recent years, driven by the rapid development of optoelectronic hardware and artificial intelligence algorithms, fluorescence suppression strategies have evolved from isolated, single-method approaches into comprehensive, multi-level synergistic systems. These systems are categorized into three distinct tiers: sample preparation, signal acquisition, and data processing. At the sample preparation level, techniques such as photobleaching and surface-enhanced Raman spectroscopy (SERS) are employed to eliminate or bypass the generation of fluorescence at the source. At the signal acquisition level, instrumental improvements—including the use of long-wavelength near-infrared excitation (typically 785 nm or 1 064 nm), confocal spatial filtering, and shifted excitation Raman difference spectroscopy (SERDS)— are utilized to physically isolate Raman signals from the fluorescence background. Furthermore, at the data processing level, numerical baseline correction methods such as polynomial fitting, penalized least squares (e.g., airPLS, arPLS), wavelet transform, and derivative algorithms are increasingly integrated into the analytical pipeline to extract Raman spectral features from mixed signals without increasing hardware costs or acquisition time. This review provides a systematic categorization and critical evaluation of these fluorescence suppression methods, detailing their underlying principles, technical advantages, and inherent limitations in diverse experimental setups. By focusing on critical application scenarios—including skin barrier assessment, percutaneous absorption monitoring, the routine quality control of cosmetics, and the emerging field of portable on-site detection—this paper explores the current state of technique selection and optimization. Finally, the article discusses future development trends, emphasizing the necessity of constructing adaptive, tiered suppression strategies, developing intelligent and automated data processing algorithms, and promoting the integration of portable, multi-modal diagnostic devices. The objective of this review is to provide a comprehensive technical reference to facilitate the transition of Raman spectroscopy from a specialized laboratory tool into a routine, robust analytical platform for advancements in skin science and cosmetic research.
3.Optimization Study of Rat Models for Sequelae of Pelvic Inflammatory Disease
Zhen LIU ; Wei-ling WANG ; Yun-cheng MA ; Yu-xi WANG ; Yuan TIAN ; Qian LI ; Xiao-zhu WANG ; Xiao-yao LIU ; Mei JIANG ; Wen-hui XU ; Jian GAO ; Ting WANG
Progress in Modern Biomedicine 2025;25(12):1921-1930
Objective:To establish a stable rat model of sequelae of pelvic inflammatory disease(SPID)with clinical characteristics,and to provide a reliable experimental model for the study of the pharmcological effect and mechanism of SPID.Methods:Twenty-four 7-week-old SD rats were divided into sham operation group,model-A(108 cfu/mL mixed bacterial solution,0.2 mL),model-B(109 cfu/mL mixed bacterial solution 0.2 mL),and model-C(108 cfu/mL E.coli 0.2 mL).The weight of the rat's uterine was weighed and the uterine index was calculated.The automatic hematology analyzer was used to detect the blood routine;hematoxylin-eosin staining(HE)and masson staining were used to detect uterine pathlogical changes in rats.Enzyme-linked immunosorbent assay(ELISA)was used to detect interleukin-1β(IL-1β),interleukin-6(IL-6)and tumor necrosis factor-α(TNF-α)in rat uterine tissue homogenates.Western blot was used to detect the expression of proteins related to NF-κB signaling pathway.Results:Compared with the sham operation group,the uterine index of model-A,model-B,and model-C were significantly increased(P<0.05,P<0.01).The levels of WBC and NE in the model-A increased significantly(P<0.01).The level of LY in model-B decreased significantly(P<0.01).The levels of IL-1β,TNF-α in model-A,model-B,and model-C were significantly increased(P<0.01).The levels of IL-6 in model-A and model-B were significantly increased(P<0.05,P<0.01).The collagen volume fraction of model-A and model-B were significantly increased(P<0.01).Mechanism study indicates that the expression levels of p-IKKβ/IKKβ,p-IκBα/IκBα and p-p65/p65 in model-A were significantly increased(P<0.01),and the expression levels of IκBα/β-actin were significantly decreased(P<0.01).The expression level of p-IKKβ/IKKβ in model-B was significantly increased(P<0.01).Conclusions:A stable rat model of SPID that conforms to clinical characteristics can be successfully constructed by combining 0.2 mL of mixed bacterial solution with a concentration of 108 cfu/mL and mechanical injury.This modeling method intervened in the expression of the NF-κB inflammatory signaling pathway.
4.Effect of different detector combinations on head CT image quality and radiation dose in 320-row CT
Yun LUO ; Ming-ran SHAO ; Shang-wen YANG ; Yu-xiao WANG ; Kang SHI ; Ya-yun XU
Chinese Medical Equipment Journal 2025;46(4):57-62
Objective To compare the effects of different detector combinations of 320-row CT on the image quality and radiation dose of head CT to explore the feasibility of using a wide detector for head CT scanning.Methods Totally 100 patients underwent head CT scanning due to trauma or cerebrovascular disease at some hospital from June to August 2023 were collected prospectively and divided into group A and group B by using block randomization grouping method,with the length of the block group being 2 and 50 patients in each group.In group A,all the detectors had the widths at z-axis direction being 40×0.5 mm and head scanning was completed after multiple exposures;in group B,detector combinations with widths of 280×0.5 mm or 320×0.5 mm were chosen based on the patient's head size in the head-foot direction(z-axis direction),and head scanning was performed with a single-turn exposure.The remaining scanning and image reconstruction parameters in the two groups were kept completely consistent.The head image quality of the 2 groups was evaluated objectively and scored subjectively by 2 radiologists.The volume CT dose index(CTDIvol),dose length product(DLP)and exposure time of the 2 groups were recorded,and the effective dose(ED)was calculated.SPSS 22.0 software was used for statistical analysis.Results In terms of objective evaluation of image quality,at the level of the parietal skull group B had the CT value of gray matter,image noise and contrast to noise ratio(CNR)of the images higher than those of group A,and the differences were statistically significant(all P<0.05);at the level of the posterior skull group B had the CT values of gray and white matter,image noise and air noise lower while CNR higher than those of group A,and the differences were statistically significant(all P<0.05).In terms of subjective scoring of image quality,at the levels of parietal and posterior skull group A behaved better than group B,and the differences were statistically significant(all P<0.05).In group A 5 patients had obvious motion artifacts affecting the diagnosis and the image quality scores not higher than 2,and secondary scanning had to be carried out;In group B all the patients had no obvious motion artifacts and met the diagnosis requirements.When compared with group A Group B had the CTDIvol,DLP,ED and exposure time decreased by 17.44%,17.24%,17.48%and 85.53%,respectively,and the differences were statistically significant(all P<0.05).Conclusion A wide detector gains advantages over a 20 mm detector in image quality when 320-row CT is used for head CT scanning,with the diagnosis requirements satisfied.[Chinese Medical Equipment Journal,2025,46(4):57-62]
5.Effects of total flavonoids of Dracocephalum moldavica L.on ox-LDL-induced inflammatory response of RAW264.7 macrophages via NF-κB/NLRP3 signaling pathway
Yun-li ZHAO ; Chuan-sheng HUANG ; Xin-hong GUO ; Wen-jiang CAO ; Yong YUAN ; Xin-chun WANG
Chinese Traditional Patent Medicine 2025;47(2):413-420
AIM To study the effects of total flavonoids of Dracocephalum Moldavica L.(TFDM)on reducing the inflammatory response of RAW264.7 macrophages induced by ox-LDL via the nuclear factor κB(NF-κB)/NOD-like receptor 3(NLRP3)signaling pathway.METHODS The RAW264.7 macrophages cultured in vitro were divided into the normal group,the model group(50 μg/mL ox-LDL),the TFDM group(100 μg/mL TFDM+50 μg/mL ox-LDL),the NF-κB inhibitor group(10 μmol/L Bay11-7821+50 μg/mL ox-LDL)and the TFDM+NF-κB inhibitor group(100 μg/mL TFDM+10 μmol/L Bay11-7821+50 μg/mL ox-LDL).The cells had their viability assessed by CCK-8 method;their ROS expression detected by the ROS kit;their mRNA expressions of NF-κB p65,NLRP3,Caspase-1,IL-18 and IL-1β detected by RT-qPCR;their protein expressions of NF-κB p65,IκBα,NLRP3,pro-Caspase-1,Caspase-1,IL-18 and IL-1β by Western blot;their protein expressions of NF-κB p65 and NLRP3 detected using immunofluorescence method.RESULTS Compared with the normal group,the model group showed increased ROS expression(P<0.01);increased mRNA expressions of NF-κB p65,NLRP3,Caspase-1,IL-18 and IL-1β(P<0.05,P<0.01);decreased protein expressions of IκBα and cytoplasmic NF-κB p65(P<0.01);increased protein expressions of nuclear NF-κB p65,NLRP3,Caspase-1,IL-1 β and IL-18(P<0.01);and increased fluorescence intensity of NF-κB p65 and NLRP3(P<0.01).Compared with the model group,the groups intervened with either TFDM or TFDM+inhibitor displayed decreased ROS expression(P<0.01);the groups administrated with TFDM or NF-κB inhibitor,or TFDM+inhibitor showed decreased mRNA expressions of NF-κB p65,NLRP3,Caspase-1,IL-18 and IL-1β(P<0.05,P<0.01),increased protein expressions of IκBα and cytoplasmic NF-κB p65(P<0.05,P<0.01),decreased protein expressions of nuclear NF-κB p65,NLRP3,Caspase-1,IL-1β and IL-18(P<0.05,P<0.01),and decreased fluorescence intensity of NF-κB p65 and NLRP3(P<0.01).There existed no significant group difference between the TFDM group and the NF-κB inhibitor group(P>0.05).The TFDM+inhibitor group demonstrated decreased mRNA expressions of IL-1βand IL-18(P<0.05),increased IκBα protein expression(P<0.05),decreased protein expressions of nuclear NF-κB p65,NLRP3,Caspase-1,IL-1 β and IL-18(P<0.05),and decreased fluorescence intensity of NLRP3 protein(P<0.05).CONCLUSION TFDM can inhibit the ox-LDL-induced inflammatory response of RAW264.7 macrophages,and the mechansism may be associated with the reduced ROS expression and inflammatory factors due to the inhibited activation of the NF-κB/NLRP3 signaling pathway.
6.Effect of fasting blood glucose on coronary fractional flow reserve in patients with borderline coronary artery disease
Yi-wen ZHANG ; Ya-dong LIU ; Meng-xiao WANG ; Yi-ru WANG ; Yun-peng YANG ; Yun-fang SU ; Ji-xin ZHI
Chinese Journal of Interventional Cardiology 2025;33(5):272-277
Objective To explore the correlation between fasting blood glucose(FBG)level and fractional flow reserve(FFR)in patients with borderline coronary artery disease,and to clarify its potential influence on FFR measurement.Methods From August 2020 to August 2023,the data of 135 patients with coronary atherosclerotic heart disease who received coronary angiography and FFR evaluation in the Fourth Affiliated Hospital of Harbin Medical University were retrospectively collected.According to the exclusion and inclusion criteria,85 cases of borderline diseased vessels of single coronary artery with stenosis degree of 50%-80%were screened out,and they were divided into FBG≥6.1 mmol/L group(47 cases)and FBG<6.1 mmol/L group(38 cases).The baseline data,angiographic and functional indexes of the two groups were compared,and the correlation between FBG and FFR was analyzed.Results Compared with the FBG<6.1 mmol/L group,the FBG≥6.1 mmol/L group had a higher proportion of FFR negative results(72.3%vs.23.7%,P<0.001),and the FFR measurement values were generally increased[0.84(0.80,0.90)vs.0.75(0.68,0.80),P<0.001],with statistically significant differences.Pearson correlation analysis was performed on all lesions,and FFR>0.80(negative result)was positively correlated with FBG≥6.1 mmol/L(r=0.484,P<0.001).Conclusions Among the patients with borderline coronary artery disease(50%-80%stenosis)included in this study,FBG≥6.1 mmol/L is significantly correlated with FFR>0.80.For patients with borderline coronary lesions with elevated FBG,the influence of blood glucose factors should be carefully considered in clinical interpretation of FFR results.
7.Development of transparent manikin and its application to surgical training on medical train
Ya-jun SONG ; Wen-gang HU ; Ming-hui YANG ; Sheng-qing LYU ; Chi-bing HUANG ; Ji-feng ZOU ; Yang LI ; Yun WANG ; Ji ZHENG
Chinese Medical Equipment Journal 2025;46(6):111-115
Objective To develop a novel type of transparent simulation manikin as a surgical training model to meet the surgical treatment demand on the medical train.Methods A transparent manikin was developed with the steps of basic data collection,motherboard design and manufacture and module production and assembly.Firstly,basic data collection was carried out with reference to standardized human anatomy and parameters.Secondly,some software such as UG NX7.5 was used to construct the motherboard of the manikin.Finally,module production and assembly were performed with the materials of acrylic,transparent rubber,silicone and hydrogel and the technology of silicone infusion.Results The transparent manikin developed had its anatomy structure close to that of the real body and high visuality for its internal and external components,which simulated a variety of war wounds and thus could be integrated with the surgical training scenarios on the medical train effectively.Conclusion The transparent manikin developed is characterized by high visuality,modularity and blood flow,and meets the demands for surgical training on the medical train.[Chinese Medical Equipment Journal,2025,46(6):111-115]
8.Optimization Study of Rat Models for Sequelae of Pelvic Inflammatory Disease
Zhen LIU ; Wei-ling WANG ; Yun-cheng MA ; Yu-xi WANG ; Yuan TIAN ; Qian LI ; Xiao-zhu WANG ; Xiao-yao LIU ; Mei JIANG ; Wen-hui XU ; Jian GAO ; Ting WANG
Progress in Modern Biomedicine 2025;25(12):1921-1930
Objective:To establish a stable rat model of sequelae of pelvic inflammatory disease(SPID)with clinical characteristics,and to provide a reliable experimental model for the study of the pharmcological effect and mechanism of SPID.Methods:Twenty-four 7-week-old SD rats were divided into sham operation group,model-A(108 cfu/mL mixed bacterial solution,0.2 mL),model-B(109 cfu/mL mixed bacterial solution 0.2 mL),and model-C(108 cfu/mL E.coli 0.2 mL).The weight of the rat's uterine was weighed and the uterine index was calculated.The automatic hematology analyzer was used to detect the blood routine;hematoxylin-eosin staining(HE)and masson staining were used to detect uterine pathlogical changes in rats.Enzyme-linked immunosorbent assay(ELISA)was used to detect interleukin-1β(IL-1β),interleukin-6(IL-6)and tumor necrosis factor-α(TNF-α)in rat uterine tissue homogenates.Western blot was used to detect the expression of proteins related to NF-κB signaling pathway.Results:Compared with the sham operation group,the uterine index of model-A,model-B,and model-C were significantly increased(P<0.05,P<0.01).The levels of WBC and NE in the model-A increased significantly(P<0.01).The level of LY in model-B decreased significantly(P<0.01).The levels of IL-1β,TNF-α in model-A,model-B,and model-C were significantly increased(P<0.01).The levels of IL-6 in model-A and model-B were significantly increased(P<0.05,P<0.01).The collagen volume fraction of model-A and model-B were significantly increased(P<0.01).Mechanism study indicates that the expression levels of p-IKKβ/IKKβ,p-IκBα/IκBα and p-p65/p65 in model-A were significantly increased(P<0.01),and the expression levels of IκBα/β-actin were significantly decreased(P<0.01).The expression level of p-IKKβ/IKKβ in model-B was significantly increased(P<0.01).Conclusions:A stable rat model of SPID that conforms to clinical characteristics can be successfully constructed by combining 0.2 mL of mixed bacterial solution with a concentration of 108 cfu/mL and mechanical injury.This modeling method intervened in the expression of the NF-κB inflammatory signaling pathway.
9.Effect of fasting blood glucose on coronary fractional flow reserve in patients with borderline coronary artery disease
Yi-wen ZHANG ; Ya-dong LIU ; Meng-xiao WANG ; Yi-ru WANG ; Yun-peng YANG ; Yun-fang SU ; Ji-xin ZHI
Chinese Journal of Interventional Cardiology 2025;33(5):272-277
Objective To explore the correlation between fasting blood glucose(FBG)level and fractional flow reserve(FFR)in patients with borderline coronary artery disease,and to clarify its potential influence on FFR measurement.Methods From August 2020 to August 2023,the data of 135 patients with coronary atherosclerotic heart disease who received coronary angiography and FFR evaluation in the Fourth Affiliated Hospital of Harbin Medical University were retrospectively collected.According to the exclusion and inclusion criteria,85 cases of borderline diseased vessels of single coronary artery with stenosis degree of 50%-80%were screened out,and they were divided into FBG≥6.1 mmol/L group(47 cases)and FBG<6.1 mmol/L group(38 cases).The baseline data,angiographic and functional indexes of the two groups were compared,and the correlation between FBG and FFR was analyzed.Results Compared with the FBG<6.1 mmol/L group,the FBG≥6.1 mmol/L group had a higher proportion of FFR negative results(72.3%vs.23.7%,P<0.001),and the FFR measurement values were generally increased[0.84(0.80,0.90)vs.0.75(0.68,0.80),P<0.001],with statistically significant differences.Pearson correlation analysis was performed on all lesions,and FFR>0.80(negative result)was positively correlated with FBG≥6.1 mmol/L(r=0.484,P<0.001).Conclusions Among the patients with borderline coronary artery disease(50%-80%stenosis)included in this study,FBG≥6.1 mmol/L is significantly correlated with FFR>0.80.For patients with borderline coronary lesions with elevated FBG,the influence of blood glucose factors should be carefully considered in clinical interpretation of FFR results.
10.Development of transparent manikin and its application to surgical training on medical train
Ya-jun SONG ; Wen-gang HU ; Ming-hui YANG ; Sheng-qing LYU ; Chi-bing HUANG ; Ji-feng ZOU ; Yang LI ; Yun WANG ; Ji ZHENG
Chinese Medical Equipment Journal 2025;46(6):111-115
Objective To develop a novel type of transparent simulation manikin as a surgical training model to meet the surgical treatment demand on the medical train.Methods A transparent manikin was developed with the steps of basic data collection,motherboard design and manufacture and module production and assembly.Firstly,basic data collection was carried out with reference to standardized human anatomy and parameters.Secondly,some software such as UG NX7.5 was used to construct the motherboard of the manikin.Finally,module production and assembly were performed with the materials of acrylic,transparent rubber,silicone and hydrogel and the technology of silicone infusion.Results The transparent manikin developed had its anatomy structure close to that of the real body and high visuality for its internal and external components,which simulated a variety of war wounds and thus could be integrated with the surgical training scenarios on the medical train effectively.Conclusion The transparent manikin developed is characterized by high visuality,modularity and blood flow,and meets the demands for surgical training on the medical train.[Chinese Medical Equipment Journal,2025,46(6):111-115]

Result Analysis
Print
Save
E-mail