1.Visualization analysis of studies on Oncomelania hupensis control from 2005 to 2024
Wen ZHU ; Huatang LUO ; Hao WANG ; Yuelin XIONG ; Cong LIU
Chinese Journal of Schistosomiasis Control 2026;38(1):84-91
Objective To analyze Chinese and English publications pertaining to Oncomelania hupensis control from 2005 to 2024, so as to decipher the research status and hotspots of O. hupensis control. Methods Chinese and English publications pertaining to O. hupensis control from 2005 to 2024 were retrieved in the Web of Science Core Collection Database and China National Knowledge Infrastructure. The annual number of publications was analyzed from 2005 to 2024, and the author and institution cooperation networks were mapped using the software CiteSpace 6.3.1. Keywords were extracted from publications to map the co-occurrence, burst and timeline of keywords to identify the research hotspots of O. hupensis control. Results A total of 158 English publications and 771 Chinese publications were included for bibliometric analyses. The overall output of English publications was relatively small from 2005 to 2024, the annual average publication was 7.90 publications. Parasites & Vectors was the most productive journal by the number of publications (21 publications). The three most productive authors included Li Shizhu (24 publications), Zhou Xiaonong (13 publications), and Yang Kun (12 publications), and the three most productive institutions included Chinese Center for Disease Control and Prevention (49 publications), the WHO (27 publications), and Fudan University (25 publications). The annual average number of Chinese publications was high from 2005 to 2015 (57.73 publications), and reduced to 15.11 publications during the period from 2016 to 2024, with Chinese Journal of Schistosomiasis Control as the most productive journal (241 publications). The three most productive authors included Wang Wanxian (18 publications), Sun Qixiang (16 publications), and Dai Jianrong (16 publications), and the three most productive institutions included Jiangsu Institute of Parasitic Diseases (55 publications), Chinese Center for Disease Control and Prevention (47 publications), and Hubei Uni-versity (38 publications). Among the 158 English publications, molluscicidal effect, climate change, geographic information, biological control, machine learning were current research hotspots, and the Yangtze River and elimination were emerging research hotspots. Among the 771 Chinese publications, molluscicidal effect, niclosamide, comprehensive management, molluscicide, effectiveness evaluation, marshland, and endophyte were current research hotspots, and the future research hotspots shifted to molluscicidal effect and pyriclobenzuron. Conclusions Limited attention is paid to the research on O. hupensis control across the world. The Yangtze River, elimination, molluscicidal effect, and pyriclobenzuron may be future research hotspots. High attention is recommended to be paid to the research on O. hupensis control, and development of diverse approaches for O. hupensis control is of urgent needs. We should continue to attach importance to the control research of O. hupensis and strengthen the exploration of diverse snail extermination and control methods.
2.The first record of Anopheles messeae (Diptera: Culicidae) parasitized by water mites in China
Xue-ru CHEN ; Wen-zhen YAO ; Yu-hao LI ; Gui-chang LI ; Tao MENG ; Qun-ling FENG ; Xin-hui LIU ; Li-hong QIAO ; Xiang-ting WU ; Xue-feng ZHANG ; Cheng-lin LI ; Xue-cheng DONG ; Da-wei WANG ; Xiao-yan SI ; Yu-hong GUO
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):53-57
Objective This study reports on the obligatory parasitism of water mites Arrenurus sp. on Anopheles messeae at the Manzhouli Port, Inner Mongolia, China. Methods Duing July 2024, a survey on the mosquito diversity was conducted at the Manzhouli Port. Captured mosquitoes and their ectoparasites were identified to species level. Results A total of 1840 adult mosquitoes were collected, representing species from three genera: Culex(Cx. modestus, Cx. pipiens pallens), Aedes(Ae. dorsalis, Ae. flavidorsalis, Ae. flavescens), and Anopheles (An. messeae). Among all the mosqutioes specimens,3 out of 150 captured An. messeae were found to carry ectoparasitic mites, with number of 2,4,27 mites separately. Morphological and molecular identification reached the same result as water mites(Hydrachnidiae, Hydracrina). COI gene sequence showed 94% similarity with the closest species Arrenurus truncatellus. Conlusions Literature review suggests water mites are host-specific parasitism of mosquito species and herein with the first record of Arrenurus sp. parasiting on An. Messeae in the most high-latitude region globally.
3.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
4.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
5.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
6.Current Status and Prospects of Artificial Intelligence Technologyin Minimally Invasive Gastric Cancer Surgery
Tao ZHANG ; Boer SU ; Guanxing LIANG ; Shiman DAI ; Jiawei CHEN ; Zhengjie LIU ; Cheng PENG ; Rong LIU ; Qinglan LIN ; Yidan WU ; Yuhui WU ; Jiaming WEN ; Hong WANG ; Hao CHEN ; Jiang YU
Medical Journal of Peking Union Medical College Hospital 2026;17(4):933-942
Gastric cancer remains a highly prevalent malignancy worldwide, with surgical resection currently constituting the cornerstone of treatment aimed at improving long-term patient survival. Owing to their notable advantages, including reduced surgical trauma and accelerated postoperative recovery, minimally invasive procedures are progressively supplanting conventional open surgery and have become the mainstream approach in gastric cancer management. Concurrently, the rapid advancement of artificial intelligence (AI) technologies has enabled real-time intraoperative monitoring of surgical scenes, thereby furnishing novel technical support for adjunctive decision-making, surgical navigation, and skill assessment during gastrectomy. This article provides a systematic review of the current status of AI applications in minimally invasive gastric cancer surgery, with a particular focus on research progress pertaining to instrument recognition, surgical phase identification, delineation of normal anatomical structures, detection of metastatic foci, and early warning of intraoperative adverse events. Furthermore, we discuss the potential value of AI in enhancing surgical efficiency, ensuring patient safety, and optimizing surgical education. On this basis, we further analyze the principal challenges and inherent risks confronting current AI systems, with the aim of informing future technological innovation and facilitating clinical translation.
7.Influence of atrial septal defect on mitral valve growth after repair of coarctation of the aorta or an interrupted aortic arch in infants
Yi-Chia WANG ; Heng-Wen CHOU ; Chi-Hsiang HUANG ; Hsing-Hao HUANG ; Yih-Sharng CHEN ; En-Ting WU ; Shyh-Jye CHEN ; Ming-Tai LIN ; Shuenn-Nan CHIU ; Shu-Chien HUANG
Clinical and Experimental Pediatrics 2026;69(4):322-329
Background:
Patients with coarctation of the aorta (CoA) and an interrupted aortic arch (IAA) may present with small mitral valves (MVs) and a reduced left ventricular (LV) volume. Biventricular repair (BVR) in these patients is dependent on adequate size of the left cardiac structures.Purpose: This study evaluated the impact of the hemodynamic characteristics of atrial septal defects (ASDs) on MV growth following surgical repair.
Methods:
We retrospectively reviewed the data of patients diagnosed with CoA or IAA between 2007 and 2024. The z score for MV size measured 6 months postoperatively (Z2) was compared with the preoperative MV size (Z1). The factors associated with MV growth were also studied.
Results:
A total of 161 patients with CoA or IAA were included. Transthoracic echocardiography was used to assess the MV and LV dimensions preoperatively and 6 months postoperatively. Of the cohort, 155 (96.3%) underwent initial BVR and 6 underwent single-ventricle palliation. MV z scores significantly increased following BVR (mean change: +0.45±1.35; P<0.001) but decreased after single-ventricle repair (-0.56±0.49, P=0.04). Multivariate analysis identified the initial MV z score and ASD pressure gradient as independent predictors of MV growth (R2=0.39).
Conclusion
Annular growth of the MV was not observed in patients who underwent single-ventricle palliation. In contrast, among patients who achieved BVR, those with a small preoperative MV annulus and low ASD pressure gradient demonstrated subsequent catch-up MV growth, suggesting that adequate left-sided preload is essential for MV development.
8.Chemical constituents from the sticks and leaves of Croton cascarilloides and their biological activities
Yu-jie LÜ ; Hui-qin CHEN ; Hao WANG ; Jing-zhe YUAN ; Wen-li MEI ; Shou-bai LIU ; Hao-fu DAI
Chinese Traditional Patent Medicine 2025;47(7):2249-2254
AIM To study the chemical constituents from the sticks and leaves of Croton cascarilloides Raeusch.and their biological activities.METHODS The 95%ethanol extract from the sticks and leaves of C.cascarilloides was isolated and purified by MCI,silica gel,Sephadex LH-20 and semi-preparative HPLC,then the structures of obtained compounds were identified by physicochemical properties and spectral data.LPS-induced NO RAW264.7 cell model induced by LPS was used to evaluate its anti-inflammatory activity in vitro.GES-1 injury model induced by taurocholic acid was used to screen the gastric mucosal protection activity.RESULTS Fourteen compounds were isolated and identified as bullatantriol(1),(-)-boscialin(2),(+)-dehydrovomifoliol(3),3-(hydroxylacetyl)-indole(4),pinoresinol(5),3,7-dimethyl-octa-1,7-diene-3,6-ol(6),(+)-syringaresinol(7),curcasinlignan B(8),cleomiscosin C(9),cleomiscosinD(10),2,6-dimethyl-octa-1,7-dien-3,6-diol(11),vanillin(12),vanillic acid(13),methyl vanillate(14).Compound 4 had certain anti-inflammatory activity,with IC50 values of 73.62 μmol/L.The protective rates of 25 μmol/L compounds 1-4,6,9-12 and 14 on gastric mucosal epithelial cells were 30.07%,34.18%,23.91%,30.92%,17.51%,19.69%,31.76%,22.46%,30.56%and 14.49%,respectively.CONCLUSION Compounds 1-14 are isolated from this plant for the first time.Compound 4 shows anti-inflammatory activity,1-4,6,9-12 and 14 show different degrees of gastric mucosal epithelial cell protective activity.
9.Research advance on the application of TAES in orthopedics
Wen SU ; Jiaqi WANG ; Zhijing SHI ; Jiaqi ZHOU ; Yinan XU ; Ping HAO
China Medical Equipment 2025;22(10):146-152
As a non-invasive treatment method,transcutaneous acupoint electrical stimulation(TAES)can regulate neurological function,endocrine function and immune function through electrical stimulation for specific acupoints,which shows wide application potential in postoperative pain management,promotion of bone healing and rehabilitation in orthopedic surgery.TAES treatment has a series characteristics include non-invasiveness,convenience and effectiveness,which provides a new adjuvant treatment method for orthopedic diseases.This review elaborated the research advances of the application of TAES in orthopedics field,which provided references for further exploring its mechanism and clinical application in the future research.
10.Sleep modes based on objective measurement and diseases of the body systems:a cohort study of 87 617 participants from the UK Biobank dataset
Yimeng WANG ; Qing CHEN ; Siwen LUO ; Fuquan SHI ; Mengchao HE ; Shengfeng WANG ; Qiaorui WEN ; Yingzhong DAI ; Hao QU ; Jia CAO
Journal of Army Medical University 2025;47(4):318-325
Objective To investigate the impact of sleep modes on the risk for diseases of the body systems.Methods Based on a subset of UK Biobank dataset comprising 87 617 participants,3 sleep dimensions including 6 sleep indicators were obtained through a wrist-worn accelerometer,that is sleep duration and onset,sleep rhythm(relative amplitude and stability),and sleep quality(sleep efficiency and number of awakenings).Latent profile analysis(LPA)was applied to identify and classify distinct sleep modes.Then their longitudinal medical records were the association between different sleep modes and the risk for 467 diseases.Results LPA identified 5 subgroups of unique sleep modes in the participants.Among the 5 subgroups,the subgroup 4 had relatively optimal levels in above sleep indicators.Compared to the subgroup 4,the other 4 subgroups exhibited variations in different sleep dimensions,with at least one indicator demonstrating an unfavorable trend.These subgroups also revealed differences in racial composition,shift work and social deprivation index.Moreover,there were notable differences in the risk of various system diseases among the subgroups(P<0.05).When compared to the subgroup 4,the other 4 subgroups exhibited an elevated risk for certain diseases(comprising a total of 126 diseases),with the diseases of the circulatory system,digestive system and musculoskeletal system most common.Among the 5 subgroups,the subgroup 2(shorter sleep duration and later sleep onset)and the subgroup 5(rhythm disorder)had the highest counts of associated risks,amounting to 85 and 91 types,respectively,but there was certain difference in their systematic composition.Conclusion There are different sleep modes within the participants,and the modes are potentially associated with an increased risk for diseases of body systems.Comprehensive interventions targeting overall sleep modes rather than single sleep indicator may yield obvious health benefits.


Result Analysis
Print
Save
E-mail