1.Construction and efficacy verification of an intelligent pharmaceutical Q&A platform based on AI hallucination-suppression
Zhengwang WEN ; Jiaying WANG ; Wenyue YANG ; Haoyu YANG ; Xiao MA ; Yun LIU
China Pharmacy 2026;37(2):226-231
OBJECTIVE To construct an intelligent pharmaceutical Q&A platform for precision medication with low “artificial intelligence (AI) hallucination”, aiming to enhance the accuracy, consistency, and traceability of medication consultations. METHODS Medication package inserts were batch-processed and converted into structured data through Python programming to build a local pharmaceutical knowledge base. The retrieval and question-answering processes were designed based on large language models, and system integration and localized deployment were completed on Dify platform. By designing typical clinical medication questions and comparing the output of the intelligent pharmaceutical Q&A platform with the online version of DeepSeek across dimensions such as peak time retrieval, half-life, and dosage adjustment reasoning for patients with renal impairment, the accuracy and reliability of its retrieval and reasoning results were evaluated. RESULTS The intelligent pharmaceutical Q&A platform, constructed based on local drug package inserts, achieved 100% accuracy in retrieval and reasoning for peak time, half-life, and dosage adjustment schemes. In comparison, the online version of DeepSeek demonstrated accuracies of 30%(6/20), 50%(10/20), and 38%(23/60) across these three dimensions, respectively. CONCLUSIONS The constructed intelligent pharmaceutical Q&A platform is capable of accurately retrieving and extracting information from the local knowledge base based on clinical inquiries, thereby avoiding the occurrence of AI hallucinations and providing reliable medication decision support for healthcare professionals.
2.Fluorescence Suppression Method of Raman Spectroscopy and Its Application in Skin and Cosmetics Analysis
Yun-Xia CHEN ; Jia-Rong WANG ; Jian-Yu ZHU ; Shi-Wen LIN ; Ya-Nan LIU ; Xiao-Yue MA ; Guang-Cheng XI ; Juan LIU
Progress in Biochemistry and Biophysics 2026;53(7):1914-1926
Owing to its inherent advantages—such as being non-destructive, rapid, highly molecule-specific, and minimally interfered with by moisture—Raman spectroscopy has been widely adopted in the fields of skin barrier function assessment, monitoring the transdermal penetration of active cosmetic ingredients, and the identification and quality control of cosmetic products. Despite these strengths, the practical application of this technique faces a significant bottleneck: the strong fluorescence background generated by endogenous skin components and exogenous cosmetic additives. Endogenous skin substances, such as structural proteins (e.g., collagen and elastin), metabolic coenzymes (e.g., nicotinamide adenine dinucleotide), and pigments (e.g., melanin), together with exogenous cosmetic constituents like organic colorants, chemical sunscreens, and fragrances, often possess strong absorption and emission characteristics. When excited by lasers, these components produce a fluorescence background that can be 106 to 108 times stronger than the Raman scattering signals, effectively masking the inherently weak vibrational fingerprint information. In recent years, driven by the rapid development of optoelectronic hardware and artificial intelligence algorithms, fluorescence suppression strategies have evolved from isolated, single-method approaches into comprehensive, multi-level synergistic systems. These systems are categorized into three distinct tiers: sample preparation, signal acquisition, and data processing. At the sample preparation level, techniques such as photobleaching and surface-enhanced Raman spectroscopy (SERS) are employed to eliminate or bypass the generation of fluorescence at the source. At the signal acquisition level, instrumental improvements—including the use of long-wavelength near-infrared excitation (typically 785 nm or 1 064 nm), confocal spatial filtering, and shifted excitation Raman difference spectroscopy (SERDS)— are utilized to physically isolate Raman signals from the fluorescence background. Furthermore, at the data processing level, numerical baseline correction methods such as polynomial fitting, penalized least squares (e.g., airPLS, arPLS), wavelet transform, and derivative algorithms are increasingly integrated into the analytical pipeline to extract Raman spectral features from mixed signals without increasing hardware costs or acquisition time. This review provides a systematic categorization and critical evaluation of these fluorescence suppression methods, detailing their underlying principles, technical advantages, and inherent limitations in diverse experimental setups. By focusing on critical application scenarios—including skin barrier assessment, percutaneous absorption monitoring, the routine quality control of cosmetics, and the emerging field of portable on-site detection—this paper explores the current state of technique selection and optimization. Finally, the article discusses future development trends, emphasizing the necessity of constructing adaptive, tiered suppression strategies, developing intelligent and automated data processing algorithms, and promoting the integration of portable, multi-modal diagnostic devices. The objective of this review is to provide a comprehensive technical reference to facilitate the transition of Raman spectroscopy from a specialized laboratory tool into a routine, robust analytical platform for advancements in skin science and cosmetic research.
3.Preparation and Performance Test of Highly Stable Ammonium Ion Selective Electrode Based on Hydrophobic Solid Contact Layer
Chen-Yu LIU ; Jia-Wen YIN ; Yun-Zhe HAN ; Sheng-Kang LU ; Qing-Hui JIN
Chinese Journal of Analytical Chemistry 2025;53(5):774-784
The stability of ammonium ion selective electrode is an important indicator to ensure accurate monitoring of ammonia nitrogen concentration in drinking water.However,in long-term monitoring process,interfering ions and water molecules in water samples may penetrate into the interior of the ammonium ion selective electrode to form a water layer,which affects the potential response and stability of the electrode.Perfluorooctanoic acid is a low surface energy material,and doping it in polyaniline can reduce surface energy of the composite and improve surface roughness.In this work,five ammonium ion selective electrodes were prepared by doping polyaniline with different concentrations of perfluorooctanoic acid as a solid contact layer,which made the solid contact layer of electrode had hydrophobic properties,thereby improving stability of the ammonium ion selective electrode.The stability of the ion-selective electrode was evaluated by potential drift experiment,and the optimal doping concentration of perfluorooctanoic acid in the sediment solution was determined to be 5 mmol/L.The experiment results showed that the solid contact layer had a water contact angle of 132o under the doping concentration,the potential drift rate was 41.66 μV/h,and potential drift rate in the aqueous layer test was 1.31 mV/h,which were all better than those of the unmodified electrode.The standard deviation of the electrode potential was 1.42 mV,which was obviously superior to that of the unmodified electrode.The characteristics of high stability of the electrode made it suitable for long-term monitoring of ammonia nitrogen content in water samples.
4.Research Progress on Electrochemical Sensing Techniques for Detection of Telomerase Activity
Hai-Tang YANG ; Peng-Hua SHU ; Wen-Lin LIU ; Wen-Bo MA ; Zi-Jun YANG ; Zhi-Feng DENG ; Xin-Yun ZHANG ; Wei WEI
Chinese Journal of Analytical Chemistry 2025;53(6):864-874
The telomere structure in the cell nucleus is crucial for maintaining the stability and functions of chromosomes.Telomerase is a ribonucleoprotein reverse transcriptase,which catalyzes the elongation of telomeres using its own RNA as a template,thereby counteracting the shortening of telomeres caused by chromosome replication and cell division.Due to its overexpression in over 85%of malignant tumor cells,telomerase has emerged as a highly promising biomarker and a novel target for cancer therapy.In recent years,given the importance of precise quantification of telomerase activity in guiding medical diagnosis and treatment strategies,researchers have developed various high-performance telomerase detection techniques.Among these,electrochemical biosensing technique has cause much attention due to its high sensitivity,operational convenience,rapid response,and ease of miniaturization.This paper focused on the latest advances in electrochemical sensing technique for detection of telomerase activity,aiming to provide inspiration for designing novel telomerase activity detection strategies by elucidating three unique properties of telomerase primer extension products.
5.Ion Unidirectional Ejection Simulation Study of An Extremely Miniature Hyperbolic Linear Ion Trap
Yun-Fan HE ; Zhuo-Qing YANG ; Yan WANG ; Jiu-Wen SUN ; Yun-Na SUN ; Lu-Yue ZHU ; Di ZHANG ; Feng-Dan WANG ; Min LIU ; Gui-Fu DING ; Jin-Yuan YAO
Chinese Journal of Analytical Chemistry 2025;53(6):885-893
With the increasing demand for dynamic,real-time and rapid qualitative analysis of chemical composition in areas such as emergency response and space exploration,chip-scale mass spectrometers have attracted significant attention.These devices are expected to drive the integration of mass spectrometry with micro/nano-fabrication and intelligent sensing technologies,fostering profound innovation and breakthroughs in analytical chemistry.As an excellent mass analyzer,the ion trap exhibits numerous advantages,and its miniaturization creates favorable conditions for the high-density integration of miniature mass spectrometers.However,the reduction in ion storage capacity may compromise its sensitivity and dynamic range,rendering the study of ion unidirectional ejection in highly miniaturized ion traps of significant practical importance.In this work,a research was conducted on achieving efficient ion unidirectional ejection while maintaining high mass resolution in the extremely miniature hyperbolic linear ion trap(M-HLIT)with a field radius of 1 mm,and an electric field compensation method was proposed,which combined asymmetric electrode stretching and unbalanced RF voltage to achieve high-precision optimization of the electric field composition.Simulations showed that in an ideal structure,this method achieved 100%unidirectional ejection efficiency with the mass resolution of 518,significantly outperforming traditional asymmetric structure method(365)and unbalanced voltage method(321).Following the introduction of ion ejection slots,further optimization through bidirectional stretching and electrical parameters improved the resolution to 790 while maintaining a unidirectional ejection efficiency of 93%.This method eliminated the requirement for additional excitation voltage,offering an ideal solution for the miniature mass analyzer with high detection performance of chip-level mass spectrometers.
6.Detection of Ketamine and Norketamine Using an Aptamer-Functionalized Gra-phene Oxide Fluorescent Sensor
Li-Xia WEI ; Bo LIU ; Xiao-Yuan YANG ; Xi ZHANG ; Yi-Feng LAN ; Chao ZHANG ; Juan JIA ; Dan ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Zhe CHEN
Journal of Forensic Medicine 2025;41(4):326-339
Objective To construct an aptamer-functionalized carboxylated graphene oxide(CGO)fluo-rescent sensor to achieve highly sensitive and specific detection of ketamine(KET)and its metabolite norketamine(NK)using an aptamer capable of simultaneously recognizing KET and NK.Methods A specific aptamer for simultaneous recognition of KET and NK was screened using graphene oxide-sys-tematic evolution of ligand by exponential enrichment(GO-SELEX)and molecular docking tech-niques.The aptamer,labeled with Cy5 fluorescence,was chemically conjugated to CGO to construct an aptamer-functionalized CGO fluorescent sensor.By optimizing detection conditions,including the mass concentration of CGO,aptamer concentration,reaction temperature,and incubation time,quantita-tive analysis of the target analytes was achieved using the ratio of fluorescence intensity changes be-fore and after target addition.The stability of the sensor in biological matrices was evaluated by moni-toring fluorescence intensity changes over incubation time in blank blood and urine,in comparison with the traditional physical adsorption-based CGO fluorescent sensor.Spiked recovery experiments in blank blood and urine were conducted to compare performance with that of HPLC-MS/MS.Results A specific aptamer A5 was selected and chemically conjugated with CGO to construct the aptamer-functionalized CGO fluorescent sensor.Under optimized conditions,the proposed fluorescent sensor ex-hibited a linear detection range of 1.0-5.0 ng/mL for KET,with a limit of detection(LOD)of 0.86 ng/mL;while for NK,the linear detection range was 1.0-5.0 ng/mL,with an LOD of 0.70 ng/mL.Com-pared with the CGO fluorescent sensor constructed via physical adsorption,this sensor demonstrated greater stability in blood and urine.The spiked recovery rates of KET and NK in blank blood and urine ranged from 81.50%to 110.03%,exhibiting detection performance comparable to that of HPLC-MS/MS.Conclusion The aptamer screening method offers a novel approach for selecting aptamers tar-geting drugs and their metabolites.The constructed aptamer-functionalized CGO fluorescent sensor pro-vides an efficient and reliable strategy for the high-performance detection of KET and NK.
7.Toxicokinetics of Chlorfenapyr and Its Metabolites in Rats
Wen-Yan LI ; Jin-Feng ZHAO ; Wei-Chen LIU ; Shi-Jing LÜ ; Jia-Xin ZHANG ; Xu-Dong ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Chao ZHANG
Journal of Forensic Medicine 2025;41(4):380-386
Objective To establish a chromatography-tandem mass spectrometry method for detecting chlorfenapyr and its metabolite tralopyril in blood,and to investigate the toxicokinetics in rats.Methods Chlorfenapyr(8 mg/kg)was administered orally to rats,and blood samples were collected from rats'canthus vein at 5 min,15 min,30 min,1 h,3 h,6 h,12 h,24 h and 48 h after administration.The blood samples were extracted using 100 μL of 5%formic acid solution and 400 μL of acetonitrile.Chlorfena-pyr was qualitatively and quantitatively detected by triple quadrupole gas chromatography-tandem mass spectrometry(GC-MS/MS)and tralopyril was detected by triple quadrupole liquid chromatography-tandem mass spectrometry(LC-MS/MS).The DAS 3.0 software was used to fit the toxicokinetic equa-tions and calculate the toxicokinetic parameters.Results Chlorfenapyr was detectable from 5 min to 24 h with a peak time of 1 h.Tralopyril was detectable from 15 min to 48 h with a peak time of 3 h.The toxicokinetic process of chlorfenapyr in rat blood conformed to a first-order absorption one-compartment open model,with the toxicokinetic equation described as C=e-0.265t-e-0.175t.Tralopyril con-formed to the first-order absorption three-compartment model,and the toxicokinetic equation was C=47 361.069e-2.209t-35 404.962e-1.486t+11 956.363e-0.512t.In the equations,C stands for the concentration of the target substance in the blood,e is the natural constant(≈2.718 28),and t stands for time.Conclu-sion This study optimized the detection method for chlorfenapyr and its metabolite tralopyril in blood.The toxicokinetic equations and parameters of chlorfenapyr and tralopyril can provide a reference for the estimation of oral intake time of chlorfenapyr.
8.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
9.Lumbar Spondylolysis in Chinese Adults: Prevalence and Musculoskeletal Conditions.
Dong YAN ; Yan Dong LIU ; Ling WANG ; Kai LI ; Wen Shuang ZHANG ; Yi YUAN ; Jian GENG ; Kang Kang MA ; Feng Yun ZHOU ; Zi Tong CHENG ; Xiao Guang CHENG
Biomedical and Environmental Sciences 2025;38(5):598-606
OBJECTIVE:
To determine the prevalence of lumbar spondylolysis (LS) and the proportion of spondylolytic spondylolisthesis (SS) in China, and to evaluate the musculoskeletal status of patients with LS and SS.
METHODS:
Spine Computed Tomography (CT) images were collected from community populations aged 40 and above in a nationwide multi-center project. LS was diagnosed, and SS was graded by an experienced radiologist. Bone mineral density (BMD) and paraspinal muscle parameters were quantified based on CT images.
RESULTS:
One hundred and seventeen patients of a total of 3,317 individuals were diagnosed with LS, corresponding to a prevalence rate of 3.53%. 63 of the 1,214 males (5.18%) and 54 of the 2,103 females (2.57%) were diagnosed with LS. SS occurred in 64/121 vertebrae (52.89%). BMD was not associated with LS ( P = 0.341). The L5 extensor paraspinal muscle density was higher in the LS group than in the non-LS group. In the LS group, patients with SS had a smaller L5 paraspinal extensor muscle cross-sectional area than those without SS ( P = 0.003).
CONCLUSION
The prevalence of LS in Chinese adults was 3.53%, with prevalence rates of 5.18% in males and 2.57% in females. Patients with LS have higher muscle density, whereas those with SS have smaller muscle cross-sectional areas at the L5 level.
Humans
;
Male
;
Female
;
Middle Aged
;
China/epidemiology*
;
Prevalence
;
Adult
;
Lumbar Vertebrae/diagnostic imaging*
;
Spondylolysis/diagnostic imaging*
;
Aged
;
Bone Density
;
Tomography, X-Ray Computed
;
Aged, 80 and over
;
Spondylolisthesis/epidemiology*
;
East Asian People
10.Optimization Study of Rat Models for Sequelae of Pelvic Inflammatory Disease
Zhen LIU ; Wei-ling WANG ; Yun-cheng MA ; Yu-xi WANG ; Yuan TIAN ; Qian LI ; Xiao-zhu WANG ; Xiao-yao LIU ; Mei JIANG ; Wen-hui XU ; Jian GAO ; Ting WANG
Progress in Modern Biomedicine 2025;25(12):1921-1930
Objective:To establish a stable rat model of sequelae of pelvic inflammatory disease(SPID)with clinical characteristics,and to provide a reliable experimental model for the study of the pharmcological effect and mechanism of SPID.Methods:Twenty-four 7-week-old SD rats were divided into sham operation group,model-A(108 cfu/mL mixed bacterial solution,0.2 mL),model-B(109 cfu/mL mixed bacterial solution 0.2 mL),and model-C(108 cfu/mL E.coli 0.2 mL).The weight of the rat's uterine was weighed and the uterine index was calculated.The automatic hematology analyzer was used to detect the blood routine;hematoxylin-eosin staining(HE)and masson staining were used to detect uterine pathlogical changes in rats.Enzyme-linked immunosorbent assay(ELISA)was used to detect interleukin-1β(IL-1β),interleukin-6(IL-6)and tumor necrosis factor-α(TNF-α)in rat uterine tissue homogenates.Western blot was used to detect the expression of proteins related to NF-κB signaling pathway.Results:Compared with the sham operation group,the uterine index of model-A,model-B,and model-C were significantly increased(P<0.05,P<0.01).The levels of WBC and NE in the model-A increased significantly(P<0.01).The level of LY in model-B decreased significantly(P<0.01).The levels of IL-1β,TNF-α in model-A,model-B,and model-C were significantly increased(P<0.01).The levels of IL-6 in model-A and model-B were significantly increased(P<0.05,P<0.01).The collagen volume fraction of model-A and model-B were significantly increased(P<0.01).Mechanism study indicates that the expression levels of p-IKKβ/IKKβ,p-IκBα/IκBα and p-p65/p65 in model-A were significantly increased(P<0.01),and the expression levels of IκBα/β-actin were significantly decreased(P<0.01).The expression level of p-IKKβ/IKKβ in model-B was significantly increased(P<0.01).Conclusions:A stable rat model of SPID that conforms to clinical characteristics can be successfully constructed by combining 0.2 mL of mixed bacterial solution with a concentration of 108 cfu/mL and mechanical injury.This modeling method intervened in the expression of the NF-κB inflammatory signaling pathway.

Result Analysis
Print
Save
E-mail