1.Longitudinal Associations between Vitamin D Status and Systemic Inflammation Markers among Early Adolescents.
Ting TANG ; Xin Hui WANG ; Xue WEN ; Min LI ; Meng Yuan YUAN ; Yong Han LI ; Xiao Qin ZHONG ; Fang Biao TAO ; Pu Yu SU ; Xi Hua YU ; Geng Fu WANG
Biomedical and Environmental Sciences 2025;38(1):94-99
2.Evaluation of the function and activity of masticatory muscles using a self-developed wireless surface electromyography system.
Wenbo LI ; Yujia ZHU ; Qingzhao QIN ; Shenyao SHAN ; Zixiang GAO ; Aonan WEN ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(3):346-353
OBJECTIVES:
This study aimed to evaluate the repeatability and reliability of a self-developed domestic wireless surface electromyography (sEMG) system (Oralmetry) in assessing the activity of the temporalis and masseter muscles to provide theoretical support for its clinical application.
METHODS:
Twenty-two volunteers were recruited. Through multiple repeated measurements, the sEMG signals of bilateral anterior temporalis and masseter muscles during maximum voluntary clenching were collected using the self-developed sEMG device, Oralmetry, and two commercial sEMG devices (Zebris and Teethan), filtered, screened, and standardized. Seven sEMG indicators for assessing masticatory muscle function were calculated. The intraclass correlation coefficient (ICC) was used to evaluate the repeatability of the measurements from the three sEMG devices, and statistical analysis was conducted to compare the consistency of the seven sEMG indicators obtained from the devices.
RESULTS:
Among the 22 participants, the ICC values of the repeated measurements from the three sEMG devices ranged from 0.88 to 0.99. The measurements of three sEMG indicators (antero-posterior coeffificient, percentage overlapping coeffificient_MM, and percentage overlapping coeffificient_TA) obtained by Zebris were significantly different from those obtained by Oralmetry and Teethan (P<0.05). No significant differences in the measurements of the seven sEMG indicators were found between Oralmetry and Teethan.
CONCLUSIONS
Oralmetry and the two commercial sEMG devices demonstrated good repeatability in capturing sEMG indicators for evaluating masticatory muscle function. In particular, Oralmetry showed the highest ICC values. All three devices also exhibited good consistency in measuring sEMG indicators, and a high agreement was observed between the two wireless sEMG devices (Oralmetry and Teethan). These findings provide theoretical support for the clinical application of Oralmetry.
Humans
;
Electromyography/methods*
;
Masseter Muscle/physiology*
;
Masticatory Muscles/physiology*
;
Wireless Technology
;
Reproducibility of Results
;
Temporal Muscle/physiology*
;
Male
;
Adult
;
Female
;
Young Adult
3.Digital design and manufacturing method of double constrained split guide for orthodontic miniscrew implantation.
Xin DU ; Aonan WEN ; Zixiang GAO ; Zhihua LI ; Sheng ZHANG ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(4):603-612
This study explored a novel digital design and fabrication method for a double constrained split orthodontic miniscrew guide to improve the accuracy and safety of clinical miniscrew implantation and reduce related complications. A patient requiring miniscrew implantation was selected, and data were acquired using cone beam computed tomography (CBCT) and intraoral optical scanning. For the construction of a double constrained split guide including a screw-hole guide and an insertion rod guide, different types of software such as Mimics 24.0, Geomagic wrap 2021, and Materialise magics 21.0 were utilized for 3D reconstruction, model integration, and guide design. The guide was then fabricated via laser metal 3D printing. Model and intraoral try-in results demonstrated that the guide fitted well and was stable. Postoperative CBCT verified that the final miniscrew implantation site was consistent with the preoperative design, and no related complications occurred. This double constrained split orthodontic miniscrew guide provides a precise and safe digital solution for clinical miniscrew implantation.
Humans
;
Bone Screws
;
Cone-Beam Computed Tomography
;
Printing, Three-Dimensional
;
Orthodontic Anchorage Procedures/instrumentation*
;
Imaging, Three-Dimensional
;
Computer-Aided Design
4.Preliminary study on the influence of the dimensional stability of 3D printed resin master model on the replication accuracy of implant replicas.
Xin LI ; Yuzong LU ; Yongtao YANG ; Aonan WEN ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(5):689-695
OBJECTIVES:
This study aimed to investigate the influence of the dimensional stability of 3D printed resin master model on the replication accuracy of implant replicas.
METHODS:
Ten digital impressions of patients undergoing continuous crowns or fixed bridge restoration supported by two implants were obtained, and resin models with implant replicas were 3D printed. Scanning rods were fixed on the replicas 3, 7, and 14 days after printing. The 3D, linear, and angular deviations of the scanning rods at different times were analyzed through Geomagic Wrap 2021 software.
RESULTS:
The position of the replicas shifted mesiolingually, in the same direction as the shrinkage of the model. From day 7 onward, the 3D, distance linear, and angular deviations of the replicas (scanning rod) significantly increased compared with those on the 3rd day (P<0.05). On the 14th day, the changes were even more pronounced, with the above deviations showing statistical significance (P<0.05) compared with those for the 3-day and 7-day groups. No statistical difference in height linear deviation was observed among the groups.
CONCLUSIONS
The insufficient dimensional stability of 3D printed resin models can lead to changes in the relative position and angle of the replicas, thereby affecting the accuracy of the replicas in recreating the implant's position. Complete manufacturing of prosthesis is recommended within 7 days after the model is printed.
Printing, Three-Dimensional
;
Humans
;
Dental Implants
;
Models, Dental
;
Dental Impression Technique
;
Crowns
5.Multi-omics analysis of hormesis effect of lanthanum chloride on carotenoid synthesis in Rhodotorula mucilaginosa.
Hong ZHANG ; Tong WEN ; Zhihong WANG ; Xin ZHAO ; Hao WU ; Pengcheng XIANG ; Yong MA
Chinese Journal of Biotechnology 2025;41(4):1631-1648
Hormesis effect has been observed in the secondary metabolite synthesis of microorganisms induced by rare earth elements. However, the underlying molecular mechanism remains unclear. To analyze the molecular mechanism of the regulatory effect of Rhodotorula mucilaginosa in the presence of lanthanum chloride, different concentrations of lanthanum chloride were added to the fermentation medium of Rhodotorula mucilaginosa, and the carotenoid content was subsequently measured. It was found that the concentrations of La3+ exerting the promotional and inhibitory effects were 0-100 mg/L and 100-400 mg/L, respectively. Furthermore, the expression of 33 genes and the synthesis of 55 metabolites were observed to be up-regulated, while the expression of 85 genes and the synthesis of 123 metabolites were found to be down-regulated at the concentration range of the promotional effect. Notably, the expression of carotenoid synthesis-related genes except AL1 was up-regulated. Additionally, the content of β-carotene, lycopene, and astaxanthin demonstrated increases of 10.74%, 5.02%, and 3.22%, respectively. The expression of 5 genes and the synthesis of 91 metabolites were up-regulated, while the expression of 35 genes and the synthesis of 138 metabolites were down-regulated at the concentration range of the inhibitory effect. Meanwhile, the content of β-carotene, lycopene, and astaxanthin decreased by 21.73%, 34.81%, and 35.51%, respectively. In summary, appropriate concentrations of rare earth ions can regulate the synthesis of secondary metabolites by modulating the activities of various enzymes involved in metabolic pathways, thereby exerting the hormesis effect. The findings of this study not only contribute to our comprehension for the mechanism of rare earth elements in organisms but also offer a promising avenue for the utilization of rare earth elements in diverse fields, including agriculture, pharmaceuticals, and healthcare.
Lanthanum/pharmacology*
;
Rhodotorula/genetics*
;
Carotenoids/metabolism*
;
Hormesis/drug effects*
;
Fermentation
;
Multiomics
6.Rapid Monitoring of Key Indicators in Growth Process of Chlorella Using Near-Infrared Spectroscopy Technology
Wen-Hui SONG ; Shi-Jie DU ; Yan LIU ; Qiao WANG ; Xin LIU ; Zhi-Yong GONG
Chinese Journal of Analytical Chemistry 2025;53(4):660-668
The traditional detection methods for monitoring the biomass,protein,chlorophyll content and other key indicators in the growth of chlorella have some problems,including complicated operation,slow detection speed and difficult large-scale application.In this study,a fast and efficient monitoring method for the key indicators in the growth of chlorella was established using near infrared spectroscopy and chemometrics.Near-infrared spectroscopy was used to collect near-infrared spectra of chlorella algal fluid at different growth stages,and standard methods were used to detect the biomass,protein and chlorophyll contents of corresponding samples.A quantitative analysis model was established based on partial least squares regression(PLSR).To improve the prediction ability of the model,multiplicative scatter correction(MSC)was used to reduce the interference of scattering on the raw spectrum(RS),standard normal variate(SNV)was used to normalize the original spectral data to eliminate differences between samples,continuous wavelet transform(CWT)was used to obtain the key features of spectral data,the first derivative(1st)was used to enhance the differentiation of the original spectral features,and monte carlo-uninformative variable elimination(MC-UVE)and randomization test(RT)were used to screen the valid variables in the wavelength.By evaluating the prediction ability of different models,the quantitative analysis models of chlorella biomass,protein and chlorophyll content were finally determined.The results showed that the model based on 1st combined with RT spectra had better predictive ability for chlorella nutrient content detection,and the root mean square errors of prediction(RMSEP)and coefficients of determination(R2)were 0.041 and 0.933 for biomass,0.012 and 0.973 for protein,and 0.517 and 0.962 for chlorophyll,respectively.This model showed practical application value,and could realize the rapid and accurate detection of chlorella biomass,protein and chlorophyll content at the same time.
7.Clinical Study on Yiqi Huoxue Prescription in the Treatment of Mild Cervical Spondylotic Myelopathy of Qi Deficiency and Blood Stasis Type
Siyuan RAO ; Yongpeng LIN ; Rui LIN ; Junbiao GUO ; Yong WEN ; Xiaoqiang DENG ; Jianbo ZENG ; Huimin WANG ; Bolai CHEN
Journal of Guangzhou University of Traditional Chinese Medicine 2025;42(2):309-314
Objective To investigate the clinical efficacy of Yiqi Huoxue Prescription(derived from Shengyu Decoction)in the treatment of mild cervical spondylotic myelopathy(CSM)with qi deficiency and blood stasis type.Methods A total of 128 patients with mild CSM of qi deficiency and blood stasis type who admitted to Guangdong Provincial Hospital of Chinese Medicine from January 2022 to January 2024 were randomly divided into the control group and the trial group according to the random number table method,with 64 cases in each group.The control group was treated with oral administration of Mecobalamin Tablets,and the trial group was treated with Yiqi Huoxue Prescription orally on the basis of treatment for the control group.The two groups were all treated for four weeks,and then were followed up for three months after the completion of treatment.The CSM scores of the Japanese Orthopedic Association(JOA)and the traditional Chinese medicine(TCM)syndrome scores in the two groups were observed before treatment,after two weeks of treatment,after four weeks of treatment,and three months after the completion of treatment.And then the clinical efficacy,progression of CSM and the incidence of adverse reactions of the two groups were evaluated.Results(1)During the trial,two cases in the control group and three cases in the trial group fell off,and eventually a total of 123 cases were included,62 cases in the control group and 61 cases in the trial group.(2)Three months after the completion of treatment,the total effective rate of the trial group was 93.44%(57/61)and that of the control group was 82.26%(51/62),and the intergroup comparison(tested by chi-square test)showed that the efficacy of the trial group was significantly superior to that of the control group,the difference being statistically significant(P<0.05).(3)After two and four weeks of treatment as well as three months after the completion of treatment,JOA scores in the two groups were increased compared with those before treatment(P<0.05),and JOA scores of the trial group at various time points mentioned above were higher than those of the control group,the difference being statistically significant(P<0.05).(4)After two and four weeks of treatment as well as three months after the completion of treatment,TCM syndrome scores in the two groups were decreased compared with those before treatment(P<0.05),and TCM syndrome scores of the trial group at various time points mentioned above were lower than those of the control group,the difference being statistically significant(P<0.05).(5)During the follow-up period,there was none case of significant aggravation or progression to moderate-severe illness in the two groups,and there were no adverse events such as allergies and gastrointestinal reactions.Conclusion Yiqi Huoxue Prescription exerts certain efficacy in treating patients with mild CSM of the qi deficiency and blood stasis type,and the treatment method is effective on improving the spinal cord function and symptoms of qi deficiency and blood stasis type,and slowing down the progression of disease in the patients,with high safety.
8.Construction of a postoperative mortality risk model for patients with acute aortic dissection based on XGBoost-SHAP method
Xin ZHANG ; Min FANG ; Yi CAO ; Ting-Ting LI ; Xian-Kong LIU ; Jia-Yi DANG ; Xue-Sen ZHAO ; Hong-Qin REN ; Jia-Ze GENG ; Kai-Wen WANG ; Tie-Sheng HAN ; Yong-Bo ZHAO ; Dong MA
Medical Journal of Chinese People's Liberation Army 2025;50(10):1226-1234
Objective To develop a predictive model for postoperative mortality risk in patients with acute aortic dissection(AAD)using the Extreme Gradient Boosting(XGBoost)algorithm combined with Shapley Additive Explanation(SHAP),and to establish a prediction website to serve as a diagnostic and therapeutic support platform for clinicians and patients.Methods A retrospective cohort study design was adopted.Data from 782 AAD patients who underwent surgical treatment at the Fourth Hospital of Hebei Medical University from January 2013 to December 2023 were collected,including basic information and initial serum biomarker test results.Patients were randomly divided into training and test sets at a 7:3 ratio.An external validation set consisting of 313 AAD patients admitted to the Second Hospital of Hebei Medical University from January 2020 to December 2023 was also established for further model validation.Variables were screened using LASSO regression,and an XGBoost machine learning model was constructed and interpreted using SHAP.The predictive performance of the model was evaluated using receiver operating characteristic(ROC)curve analysis.Using the Shiny package,the XGBoost model was deployed to shinyapps.io to create a prediction website for postoperative mortality risk in AAD patients.One patient was selected by simple random sampling from the test set and the external validation set respectively for the prediction example on the Shiny webpage.Results The XGBoost model demonstrated high predictive performance for postoperative mortality in AAD patients,with area under the ROC curve(AUC)values of 0.928(95%CI 0.901-0.956)in the training set,0.919(95%CI 0.891-0.949)in the test set,and 0.941(95%CI 0.915-0.967)in the external validation set.SHAP values indicated the following order of variable importance in the model(from highest to lowest):"lactate dehydrogenase""blood chlorine""multiple organ injury""carbon dioxide combining power""prothrombin time""α-hydroxybutyric acid""creatine kinase isoenzyme""Stanford classification""combined use of bedside blood purification""gender""acute kidney injury""gastrointestinal bleeding""brain injury"and"shock".A risk prediction website for adverse postoperative outcomes in AAD patients was developed using XGBoost-SHAP method(https://dun-dunxiaolu.shinyapps.io/document/)and validated with examples.One randomly selected patient from each of the test and external validation sets was applied:the predicted mortality risk value for patient 1(who died postoperatively)was 0.9539,and that for patient 2(who survived postoperatively)was 0.0206.Conclusions The XGBoost-SHAP model demonstrates high accuracy in predicting postoperative mortality risk for AAD patients.The online prediction tool established based on this model enhances the identification efficiency of high-risk postoperative mortality patients.
9.Effect of different layers of masseter on the bony structure of facial lateral area
Yu-Qi ZHAO ; Jin-Rui JIANG ; Jin-Ran CHEN ; Ze-Chuan WANG ; Hou-En ZHOU ; Wen-Di XU ; Liu-Jun YONG
Acta Anatomica Sinica 2025;56(2):208-213
Objective To observe the morphology of the superficial,middle,and deep layers of the masseter muscle and related bony structures in the lateral facial region of adults through gross anatomy,and to probe into the effects of these muscle layers on the bony structures of the lateral facial region.Methods The bilateral masseter muscles of 12 adult cadavers were exposed,and the superficial,middle,and deep layers were separated and measured for muscle length,tendon length,and muscle belly length.After the masseter muscles were stripped,the total thickness was measured,and the mandible and zygomatic arch were exposed to measure the angle of the mandibular angle,thickness of the zygomatic arch,and width of the zygomatic arch.Observations were made of the masseter tuberosities,and statistical analysis was conducted on their interrelations.Results The zygomatic arch thickness was positively correlated with the length of superficial,middle and deep masseter muscles and the length of superficial and middle masseter belly(r superficial masseter length=0.624,r middle masseter length=0.787,r deep masseter length=0.423,r superficial masseter belly length=0.493,r middle masseter belly length=0.548).The width of the zygomatic arch was positively correlated with the lengths of the superficial and middle muscle layers and the middle muscle belly length(r superficial masseter length=0.527,r middle masseter length=0.521,r middle masseterbelly length=0.437).The angle of the mandibular angle was only negatively correlated with the middle muscle belly length(r=-0.422).The tuberosities of the superficial and middle masseter muscles were not affected by the corresponding muscle layers;However,the tuberosity of the deep masseter was negatively correlated with the length of the deep muscle and the length of the deep tendon(r deep masseter length=-0.543,r deep masseter tendon length=-0.443).Conclusion In the masseter muscle layers of Chinese individuals,the superficial and middle layers have the most significant impact on the bony structures structures of the lateral facial region.These findings are of guiding significance for the remodeling of structures in the lateral facial region.
10.Risk prediction of Reduning Injection batches by near-infrared spectroscopy combined with multiple machine learning algorithms.
Wen-Yu JIA ; Feng TONG ; Heng-Xu LIU ; Shu-Qin JIN ; Yong-Chao ZHANG ; Chen-Feng ZHANG ; Zhen-Zhong WANG ; Xin ZHANG ; Wei XIAO
China Journal of Chinese Materia Medica 2025;50(2):430-438
In this paper, near-infrared spectroscopy(NIRS) was employed to analyze 129 batches of commercial products of Reduning Injection. The batch reporting rate was estimated according to the report of Reduning Injection in the direct adverse drug reaction(ADR) reporting system of the drug marketing authorization holder of the Center for Drug Reevaluation of the National Medical Products Administration(National Center for ADR Monitoring) from August 2021 to August 2022. According to the batch reporting rate, the samples of Reduning Injection were classified into those with potential risks and those being safe. No processing, random oversampling(ROS), random undersampling(RUS), and synthetic minority over-sampling technique(SMOTE) were then employed to balance the unbalanced data. After the samples were classified according to appropriate sampling methods, competitive adaptive reweighted sampling(CARS), successive projections algorithm(SPA), uninformative variables elimination(UVE), and genetic algorithm(GA) were respectively adopted to screen the features of spectral data. Then, support vector machine(SVM), logistic regression(LR), k-nearest neighbors(KNN), naive bayes(NB), random forest(RF), and artificial neural network(ANN) were adopted to establish the risk prediction models. The effects of the four feature extraction methods on the accuracy of the models were compared. The optimal method was selected, and bayesian optimization was performned to optimize the model parameters to improve the accuracy and robustness of model prediction. To explore the correlations between potential risks of clinical use and quality test data, TreeNet was employed to identify potential quality parameters affecting the clinical safety of Reduning Injection. The results showed that the models established with the SVM, LR, KNN, NB, RF, and ANN algorithms had the F1 scores of 0.85, 0.85, 0.86, 0.80, 0.88, and 0.85 and the accuracy of 88%, 88%, 88%, 85%, 91%, and 88%, respectively, and the prediction time was less than 5 s. The results indicated that the established models were accurate and efficient. Therefore, near infrared spectroscopy combined with machine learning algorithms can quickly predict the potential risks of clinical use of Reduning Injection in batches. Three key quality parameters that may affect clinical safety were identified by TreeNet, which provided a scientific basis for improving the safety standards of Reduning Injection.
Spectroscopy, Near-Infrared/methods*
;
Drugs, Chinese Herbal/administration & dosage*
;
Machine Learning
;
Algorithms
;
Humans
;
Quality Control

Result Analysis
Print
Save
E-mail