1.Strategies for Building an Artificial Intelligence-Empowered Trusted Federated Evidence-Based Analysis Platform for Spleen-Stomach Diseases in Traditional Chinese Medicine
Bin WANG ; Huiying ZHUANG ; Zhitao MAN ; Lifeng REN ; Chang HE ; Chen WU ; Xulei HU ; Xiaoxiao WEN ; Chenggong XIE ; Xudong TANG
Journal of Traditional Chinese Medicine 2026;67(1):95-102
This paper outlines the development of artificial intelligence (AI) and its applications in traditional Chinese medicine (TCM) research, and elucidates the roles and advantages of large language models, knowledge graphs, and natural language processing in advancing syndrome identification, prescription generation, and mechanism exploration. Using spleen-stomach diseases as an example, it demonstrates the empowering effects of AI in classical literature mining, precise clinical syndrome differentiation, efficacy and safety prediction, and intelligent education, highlighting an upgraded research paradigm that evolves from data-driven and knowledge-driven approaches to intelligence-driven models. To address challenges related to privacy protection and regulatory compliance in cross-institutional data collaboration, a "trusted federated evidence-based analysis platform for TCM spleen-stomach diseases" is proposed, integrating blockchain-based smart contracts, federated learning, and secure multi-party computation. The deep integration of AI with privacy-preserving computing is reshaping research and clinical practice in TCM spleen-stomach diseases, providing feasible pathways and a technical framework for building a high-quality, trustworthy TCM big-data ecosystem and achieving precision syndrome differentiation.
2.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
3.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
4.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
5.Expression and Clinical Significance of PLCβ4 Gene in Hepatocellular Carcinoma Analyzed Based on TCGA Database and Experimental Validation
Limei WEN ; Yali GUO ; Qiang HOU ; Dongxuan ZHENG ; Wu DAI ; Xiang GAO ; Jianhua YANG ; Junping HU
Cancer Research on Prevention and Treatment 2025;52(6):502-510
Objective To analyze the PLCβ4 gene mRNA expression and its clinical significance in hepatocellular carcinoma (HCC) based on TCGA database. Methods Based on the data on 424 clinical samples (including 374 cases of HCC tissues and 50 cases of nontumor liver tissues) in the TCGA database, Kaplan–Meier method, Cox regression analysis, and immune infiltration analysis were performed to evaluate the relationship between PLCβ4 gene and the clinical characteristics and survival prognosis of HCC patients. Correlation analysis between PLCβ4 gene and 24 types of immune cells was applied to investigate the relationship between PLCβ4 gene and immune cell infiltration and mRNA expression level of TP53 gene, a high-frequency mutation gene in HCC. In addition, paraffin sections of highly, moderately, and poorly differentiated tumor tissues and normal liver tissues from HCC patients were collected. The histopathological observation was carried out via HE staining method, and the expression levels of PLCβ4 and Ki-67 proteins in each clinical sample were verified through the immunohistochemical method. Results The expression level of PLCβ4 gene in HCC was significantly higher than that in normal tissues (P<0.01), and all patients in the PLCβ4 high-expression group had a significantly longer overall survival than those in the low-expression group (P<0.05), which suggested that PLCβ4 substantially affected the prognosis of HCC patients. Correlation analysis showed that the expression level of PLCβ4 gene was highly correlated with immune cell infiltration and the expression level of TP53 gene. As verified by clinical sample experiments, HE staining experiments and immunohistochemical results revealed that PLCβ4 gene expression in HCC tissue samples was significantly higher than that in normal tissues (P<0.001), and it was negatively correlated with the degree of differentiation. Conclusion PLCβ4 may serve as an independent prognostic factor in HCC and is expected to be a novel molecular target for HCC treatment.
6.Thoughts and Explorations on the Cultivation of Top Innovative Talents in Nursing With Chinese Characteristics in the New Era
Xiaofeng XIE ; Fengying ZHANG ; Yi YIN ; Jinbo CUI ; Jianhua LI ; Jiazhuang XU ; Xiaolin HU ; Yali TIAN ; Wen ZHOU ; Xuantao WU ; Shuanjiu LI ; Ka LI
Journal of Sichuan University (Medical Sciences) 2025;56(3):881-886
The cultivation of top innovative nursing talents with Chinese characteristics in the new era lends critical support to the accomplishment of the strategic goal of the Healthy China Initiative.Herein,we reviewed the historical development of nursing science in China,clarified the conceptual framework of nursing science with Chinese characteristics in the new era,and identified the essential qualities and competencies required for top innovative nursing talents.Furthermore,we analyzed the mission and challenges in cultivating these nursing talents,and put forward new approaches,including formulating new ethics and political education theories specific to nursing science with Chinese characteristics,establishing a cross-disciplinary educational model of Nursing+X,and creating a new nursing talent cultivation ecosystem adapted to the era of human-machine symbiosis.This study provides theoretical insights into the cultivation of top innovative nursing talents who align their development well with national strategic needs,embody patriotism,and possess a strong sense of contemporary responsibility.
7.Establishment and evaluation of a lipopolysaccharide-induced acute respiratory distress syndrome model in minipigs
Chuang-Ye WANG ; Ran WANG ; Jian ZHANG ; Ling-Xiao QIU ; Bin QING ; Heng YOU ; Jin-Cheng LIU ; Bin WANG ; Nan-Bo WANG ; Jia-Yu LI ; Xing LIU ; Shuang WANG ; Jin HU ; Jian WEN ; Quan LI ; Xiao-Ou HUANG ; Kun ZHAO ; Shuang-Lin LIU ; Gang LIU ; Mei-Ju WANG ; Qing XIANG ; Hong-Mei WU ; Xiao-Rong SUN ; Tao GU ; Dong ZHANG ; Qi LI ; Zhi XU
Medical Journal of Chinese People's Liberation Army 2025;50(9):1154-1161
Objective To establish a stable,reliable,and clinically relevant porcine model of endotoxin-induced acute respiratory distress syndrome(ARDS).Methods Ten 8-month-old male Bama minipigs were deeply sedated,followed by invasive mechanical ventilation and electrocardiographic monitoring.Lipopolysaccharide(LPS)was intravenously pumped at 600 μg/(kg·h)for 3 hours,then maintained at 15 μg/(kg·h)thereafter.Dynamic monitoring was performed at five time points after LPS injection(LPS 0,1,3,5,and 8 h),including arterial blood gas analysis and chest computed tomography(CT)scans.Pathological examination of lung tissues obtained via bronchoscopic biopsy(HE staining and transmission electron microscopy)was conducted.These indicators were comprehensively used to evaluate the success of the animal model.Results At 5 hours after LPS administration,8 minipigs developed symptoms such as skin cyanosis,elevated body temperature,and respiratory distress.The oxygenation index decreased to<300 mmHg.Chest CT scans showed diffuse pulmonary infiltrates.Histopathology revealed alveolar edema and hyaline membrane formation.Transmission electron microscopy demonstrated disruption of pulmonary blood-air barrier,depletion of lamellar bodies in type Ⅱ pneumocytes,inflammatory cell infiltration,and exudation of plasma proteins and fibrin.Compared with LPS 0 h,at LPS 8 h,the oxygenation index and arterial blood pH were significantly decreased(P<0.001),while blood lactic acid and serum potassium were significantly increased(P<0.05);serum calcium and base excess were significantly decreased(P<0.05),and the lung injury score based on HE-stained lung sections was significantly increased(P<0.01).Conclusion The porcine ARDS model established by continuous LPS injection can dynamically simulate the pathophysiological characteristics and typical pathological manifestations of clinical septic ARDS,making it an effective tool to study the pathogenesis,prevention,and treatment strategies of septic ARDS.
8.CURRENT DISTRIBUTION OF AEDES AEGYPTI IN LEIZHOU PENINSULA,ZHANJIANG CITY,GUANGDONG PROVINCE
Rui-Peng LU ; Jin-Hua DUAN ; Yu-Wen ZHONG ; Hui DENG ; Jun WU ; Li-Ping LIU ; Wei-Xiong YIN ; Feng XING ; Hui HUANG ; Chang-Jie FU ; Zong-Jing CHEN ; Ming-Ji CHENG ; Sheng-Jun HU ; Ya-Ting CHEN ; Wen-Ting GUO ; Li-Feng LIN
Acta Parasitologica et Medica Entomologica Sinica 2025;32(1):16-21
Objective To investigate the status of population dynamics and distribution changes of Aedes aegypti in Guangdong Province.Methods Continuous monitoring was conducted from May 2018 to July 2024 in Wushi Town and Qishui Town,Leizhou City,Zhanjiang City,Guangdong Province.Additionally,a survey of the distribution of Ae.aegypti along the Leizhou Peninsula coast was carried out.Results The density of Ae.aegypti in Zhanjiang showed a gradual decline from 2018 to 2024.The last detection of adult Ae.aegypti in Wushi Town was in September 2021,and the last larva was found in October 2023.No Ae.aegypti was detected in Qishui Town during surveys from 2021 to 2024.A survey of 18 coastal villages in the Leizhou Peninsula revealed no detections of Ae.aegypti.Conclusions This study provides a basis for understanding the distribution and population density fluctuations of Ae.aegypti,assessing its invasion risk,and scientifically conducting relevant prevention and control efforts.
9.Data Mining Study on Xin'an Doctors for the Treatment of Liver Cirrhosis Based on Symptoms-Syndromes-Medicines
Hui WANG ; Huiyuan ZHENG ; Jingxi FENG ; Wen LI ; Jili HU ; Peng WU
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(6):45-51
Objective To explore the characteristics of Xin'an doctors in the syndrome differentiation and treatment of liver cirrhosis from the dimensions of symptoms,syndromes and medication using data mining methods.Methods Medical cases and prescriptions for liver cirrhosis were collected from Xin'an medical literature.Data mining was performed using frequency analysis,complex network analysis,Louvain clustering analysis and factor analysis to investigate syndromes,symptoms,and medicines.Results A total of 363 prescriptions were analyzed,involving 15 syndromes and 325 kinds of Chinese materia medica,with 33 identified as core medications.Tonifying herbs were the most frequently used;the primary syndromes were liver qi stagnation and water retention;core symptoms of liver qi stagnation included emotional distress,reduced appetite and hypochondriac pain,with core medications such as Bupleuri Radix and Poria;core symptoms of water retention included lower limb edema and abdominal distension,with core medications such as Pinelliae Rhizoma,Citri Reticulatae Pericarpium,Magnoliae Officinalis Cortex and Poria.Factor analysis of core medications identified 12 common factors.Conclusion The pathogenesis of liver cirrhosis involves deficiency in nature and excess in superficiality,primarily affecting the liver and closely related to the spleen and kidneys.Xin'an doctors emphasize treating the symptoms with qi-regulating,blood-activating,dampness-drying and heat-clearing strategies,while simultaneously addressing the root with qi-tonifying,spleen-strengthening,liver-nourishing and kidney-replenishing therapies.
10.Comparative efficacy of robot-assisted balloon tibioplasty and traditional open reduction and internal fixation in the treatment of AO/OTA type 41B2 tibial plateau fracture
Jialang HU ; Jing JIAO ; Yucheng HUANG ; Wen XIONG ; Jinyi WU ; Hai DENG ; Zhihua GENG ; Xuan MA ; Ming CHEN
Chinese Journal of Trauma 2025;41(4):369-376
Objective:To compare the clinical efficacy of robot-assisted balloon tibioplasty and traditional open reduction and internal fixation in the treatment of AO/OTA type 41B2 tibial plateau fracture.Methods:A retrospective cohort study was conducted to analyze the clinical data of 70 patients with AO/OTA type 41B2 tibial plateau fracture who were admitted to Wuhan Fourth Hospital from September 2019 to October 2022, including 35 males and 35 females, aged 24-62 years [(44.9±9.5)years]. Among them, 41 patients underwent traditional open reduction and internal fixation (open reduction group), while 29 patients underwent robot-assisted balloon tibioplasty (balloon group). The following parameters were compared between the two groups: incision length, operative blood loss, number of intraoperative fluoroscopies, operation duration, and length of hospital stay; Rasmussen radiological scores at 3 days, 3 months postoperatively, and at the last follow-up and the fracture healing time; pain visual analogue scale (VAS) scores preoperatively, and at 2 days and 3 months postoperatively; knee joint range of motion at 5 days, 3 months postoperatively, and at the last follow-up; Hospital for Special Surgery (HSS) knee function scores at 3, 6 months postoperatively, and at the last follow-up; incidence rate of complications at 15 days postoperatively.Results:All the patients were followed for 12-24 months [18(17, 20)months]. The incision length, operative blood loss and length of hospital stay in the balloon group were 1.6(1.5, 3.0)cm, 5.0(5.0, 5.0)ml and 11.0(9.0, 14.0)days, less than those in the open reduction group [12.0(11.0, 12.0)cm, 100.0(50.0, 120.0)ml and 15.0(13.0, 20.0)days] ( P<0.01). The number of intraoperative fluoroscopies and operation duration in the open reduction group were 9.0(7.0, 10.0)times and 75.0(60.0, 90.0)minutes, less than those in the balloon group [336.0(335.0, 340.0)times and [90.0(70.0, 105.0)minutes] ( P<0.05). There were no significant differences in the Rasmussen radiological scores between the two groups at 3 days, 3 months postoperatively, or at the last follow-up ( P>0.05). The fracture healing time in the balloon group was 3.0(3.0, 3.0)months, shorter than 3.0(3.0, 3.5)months in the open reduction group ( P<0.05). No significant differences were observed between the two groups in VAS scores before operation or at 3 months postoperatively ( P>0.05). However, the VAS score was 2.0(2.0, 3.0)points at 2 days postoperatively in the balloon group, lower than 5.0(5.0, 6.0)points in the open reduction group ( P<0.01). The knee joint range of motion at 5 days, 3 months postoperatively and at the last follow-up were 90.0(85.0, 90.0)°, 135.0(130.0, 135.0)° and 140.0(135.0, 140.0)° in the balloon group, better than 65.0(60.0, 70.0)°, 125.0(120.0, 130.0)°, 130.0(130.0, 140.0)° in the open reduction group ( P<0.01). Similarly, the HSS knee function scores at 3, 6 months postoperatively and at the last follow-up were 80.0(80.0, 81.0)points, 91.0(90.0, 92.0)points, and 95.0(93.0, 96.0)points in the balloon group, better than 71.0(70.0, 72.0)points, 83.0(81.0, 84.0)points, and 86.0(84.0, 88.0)points in the open reduction group ( P<0.01). The incidence rate of complications in the balloon group was 0, comparable to 12% (5/41) in the open reduction group ( P>0.05). Conclusion:Compared with traditional open reduction and internal fixation surgery, robot-assisted balloon tibioplasty in the treatment of AO/OTA type 41B2 tibial plateau fracture significantly reduces surgical trauma, alleviates postoperative pain, promotes fracture healing, and accelerates functional recovery of the affected limbs.

Result Analysis
Print
Save
E-mail