1.Outcomes of transcatheter transseptal mitral valve-in-valve replacement using Edward's SAPIEN 3 in high surgical risk patients-a multicenter study in China
Xiang CHEN ; Bin WANG ; Yi-wei XU ; Xiao-ping PENG ; Fan QIAO ; Xiang-wen LIANG ; Ke HAN ; Xiao-fei JIANG ; Xiang MA ; Wen-yi YANG ; Guo-sheng FU ; Mao-long SU ; Yan WANG
Chinese Journal of Interventional Cardiology 2025;33(2):79-86
Objective To evaluate the safety and efficacy of valve-in-valve transcatheter mitral valve replacement(ViV-TMVR)in patients with bioprosthetic valve degeneration who are at high surgical risk.Methods This study is a multi-center,retrospective cohort analysis of 20 consecutive patients who underwent transseptal ViV-TMVR using the Edwards SAPIEN 3 transcatheter heart valve(THV).The primary endpoints include technical success and procedural success,both defined according to the Mitral Valve Academic Research Consortium(MVARC)criteria,as well as mortality and functional change assessed based on New York Heart Association(NYHA)classification at 30-days and six months post-procedure.Clinical follow-up assessments are conducted at 30-days and six months.Results From February 2021 to October 2022,a total of 20 patients with symptoms of bioprosthetic valve degeneration were enrolled across nine sites in China.The patients had a mean age of(73.5±5.5)years,with 85.0%being females and 70.0%classified as NYHA class Ⅲ/Ⅳ.The study achieved a 100.0%technical success rate and a 90.0%procedural success rate finally.All patients remained alive during the 30-day follow-up period.However,six months post-intervention,two patients(10.0%)were re-hospitalized due to heart failure,and sadly,one of them(5.0%)died.None of the patients reported any adverse events related to ViV-TMVR during the follow-up period.Notably,there was a significant improvement in NYHA class compared to baseline(P=0.0004)at six-month follow-ups.Conclusions The transseptal ViV-TMVR technique proved to be highly successful and was associated with significant improvement in NYHA class function.These findings strongly suggest that it serves as a safe and efficient treatment alternative for high-risk patients suffering from bioprosthetic valve degeneration.
2.Quality inspection of ultrasound soft tissue cutting hemostatic equipment
Jing HUANG ; Qi-di SUN ; Ao-wen DUAN ; Li XU ; Heng-yu LONG ; Hai-jiang ZHU ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(10):49-53
Objective To carry out quality inspection of the ultrasound soft tissue cutting hemostatic equipment to ensure its safety and effectiveness.Methods Five brands of ultrasound soft tissue cutting hemostatic equipment were selected and noted as test equipment A,test equipment B,test equipment C,test equipment D and test equipment E,which underwent quality inspection in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current based on YY/T 0644-2008 Ultrasonics-surgical systems—Measurement and declaration of the basic output characteristics,YY/T 1750-2020 Ultrasonic surgical equipmetn for soft tissue excision and hemostasia and GB 9706.1-2020 Medical electrical equipment—Part 1:General requirements for basic safety and essential performance.Results The test data of the five brands in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current met the technical requirements of YY/T 0644-2008,YY/T 1750-2020,GB 9706.1-2020.Conclusion The quality inspection of the ultrasound soft tissue cutting hemostatic equipment contributes to enhancing the accuracy and stability of the equipment and decreasing the risk during its clinical application.[Chinese Medical Equipment Journal,2025,46(10):49-53]
3.Bioequivalence of rivaroxabanpian in healthy Chinese subjects
Xu ZHU ; Xiao-ni WANG ; Chang LU ; Ran ZHANG ; Ning CHEN ; Jin-mei ZHOU ; Feng ZHANG ; Wen ZHANG ; Sheng-long ZHAO ; Shun-wang HUANG ; Huan ZHOU
Chinese Pharmacological Bulletin 2025;41(11):2194-2199
Aim To evaluate the bioequivalence of two oral preparations of rivaroxaban tablets(test preparation T and refe-rence preparation R)in fasting/postprandibular state in healthy Chinese subjects.Methods A randomized,open,single-dose,four-cycle,completely repeated crossover experiment was used in this study.A total of 70 healthy male and female subjects were enrolled,including 38 subjects in the fasting group and 32 sub-jects in the postprandial group.Rivaroxaban tablets(2.5 mg/tablet)were taken orally once per cycle and their reference preparations were tested.The plasma rivaroxaban concentration was determined by LC-MS/MS method.The pharmacokinetic parameters of rivaroxaban tablets were calculated by WinNonlin software,and the parameters were analyzed and processed.Re-sults The PK parameters of rivaroxaban tablets and reference preparations in fasting group were as follows:Cmax was(72.48±17.08)and(66.36±15.64)μg·L-1,respectively.AUC0-t were(383.49±101.06)and(370.43±102.16)h·ng·mL-1,and AUC0-inr were(389.58±102.28)and(375.84±103.01)h·μg·L-,respectively.Main PK parameters of subjects taking rivaroxaban tablets orally after meals:Cmax were(66.48±15.64 and 60.87±13.44)μg·L-1,AUC0-t were(404.44±72.58)and(381.80±79.93)h·μg·L-1,re-spectively.AUC0_inf was(410.88±73.55)and(393.64±69.71)h·μg·L-1,respectively.Under fasting and postmeal conditions,subjects took rivaroxaban test and reference prepara-tion orally,one tablet(2.5 mg/tablet)each time.The geometric mean of the main pharmacokinetic parameters of rivaroxaban in plasma(Cmax,AUC0-t,AUC0-inf)and their corresponding values had a 90%confidence interval ranging from 80.00%to 125.00%.No serious adverse events or unexpected adverse e-vents occurred in both groups.Conclusion Rivaroxaban tablets are bioequivalent and safe in vivo under fasting and postprandial conditions.
4.Research progress on the application of intelligent medical treatment in abdominal war trauma
Si-Zhe WANG ; Xu SUN ; Ding-Chang LI ; Xian-Qiang LIU ; Wen-Xing GAO ; Wen ZHAO ; Hao LIU ; Guang-Long DONG
Medical Journal of Chinese People's Liberation Army 2025;50(1):22-27
Abdominal war trauma is a common and high-risk type of injury in the modern battlefield,with rapid changes in condition and a high mortality rate.There is an urgent need for emerging medical technologies to improve the efficiency and success rate of first aid for military casualties.With the development of artificial intelligence(AI),5G,and other emerging technologies,the concept of intelligent medical treatment is gradually forming and can assist in the diagnosis and treatment of abdominal trauma.This paper reviews the characteristics of abdominal war trauma in modern wars,discusses the application of intelligent medical treatment for abdominal war trauma and its drawbacks to be solved,aiming to provide reference for research related to abdominal war trauma.
5.PRELIMINARY INVESTIGATION OF EHRLICHIA AND NEOEHRLICHIA IN RODENTS AT THE IMPORTANT PORTS ALONG THE"BELT AND ROAD"
Xiao-Long ZHANG ; Jia XU ; Shi-Liang MA ; Pi-Zheng WANG ; Juan PAN ; Jia-Yuan CAO ; Zhi-Wen SUN ; Hui-Lin GUO ; Li-Li XIAO
Acta Parasitologica et Medica Entomologica Sinica 2025;32(3):160-166
Objective This study aimed to investigate natural infection of rodents with Ehrlichia and Neoehrlichia at major Chinese land-border ports along the"Belt and Road".Methods In 2022,rodents were monitored in 10 ports in northern and southern China and identified based on diagnostic morphological characteristics.The 16S rRNA genes of Ehrlichia and Neoehrlichia were detected by PCR using universal primers from rodent samples and phylogenetic analysis was performed based on the sequences of the detected positive pathogens.Results A total of 356 rodents were sampled,including 2 orders,5 families,15 genera,and 20 species.Predominantly,73,61,56,and 58 were Meriones unguiculatus(20.51%),Rattus norvegicus(17.13%),Apodemus agrarius(15.73%),and Microtus gregalis(16.29%).Only one Microtus fortis from Suifenghe Port was infected with Ehrlichia sp.Moreover,12 rodents were infected with Neoehrlichia spp.(overall positivity rate:3.37%).Conclusions Natural infections with Ehrlichia spp.and Neoehrlichia spp.were demonstrated in rodents at important Chinese land-border ports.The positivity rate of Neoehrlichia spp.was high in some ports,indicating that surveillance for ticks and their prevention and control measures should be intensified in these regions.
6.Bioequivalence of rivaroxabanpian in healthy Chinese subjects
Xu ZHU ; Xiao-ni WANG ; Chang LU ; Ran ZHANG ; Ning CHEN ; Jin-mei ZHOU ; Feng ZHANG ; Wen ZHANG ; Sheng-long ZHAO ; Shun-wang HUANG ; Huan ZHOU
Chinese Pharmacological Bulletin 2025;41(11):2194-2199
Aim To evaluate the bioequivalence of two oral preparations of rivaroxaban tablets(test preparation T and refe-rence preparation R)in fasting/postprandibular state in healthy Chinese subjects.Methods A randomized,open,single-dose,four-cycle,completely repeated crossover experiment was used in this study.A total of 70 healthy male and female subjects were enrolled,including 38 subjects in the fasting group and 32 sub-jects in the postprandial group.Rivaroxaban tablets(2.5 mg/tablet)were taken orally once per cycle and their reference preparations were tested.The plasma rivaroxaban concentration was determined by LC-MS/MS method.The pharmacokinetic parameters of rivaroxaban tablets were calculated by WinNonlin software,and the parameters were analyzed and processed.Re-sults The PK parameters of rivaroxaban tablets and reference preparations in fasting group were as follows:Cmax was(72.48±17.08)and(66.36±15.64)μg·L-1,respectively.AUC0-t were(383.49±101.06)and(370.43±102.16)h·ng·mL-1,and AUC0-inr were(389.58±102.28)and(375.84±103.01)h·μg·L-,respectively.Main PK parameters of subjects taking rivaroxaban tablets orally after meals:Cmax were(66.48±15.64 and 60.87±13.44)μg·L-1,AUC0-t were(404.44±72.58)and(381.80±79.93)h·μg·L-1,re-spectively.AUC0_inf was(410.88±73.55)and(393.64±69.71)h·μg·L-1,respectively.Under fasting and postmeal conditions,subjects took rivaroxaban test and reference prepara-tion orally,one tablet(2.5 mg/tablet)each time.The geometric mean of the main pharmacokinetic parameters of rivaroxaban in plasma(Cmax,AUC0-t,AUC0-inf)and their corresponding values had a 90%confidence interval ranging from 80.00%to 125.00%.No serious adverse events or unexpected adverse e-vents occurred in both groups.Conclusion Rivaroxaban tablets are bioequivalent and safe in vivo under fasting and postprandial conditions.
7.Investigation of tumor-suppressive mechanism of Guiqi Yiyuan Extract combined with cisplatin in Lewis lung cancer mice via TXNIP/NLRP3/Caspase-1/GSDMD pathway
Qiong-qiong GUO ; Wen-jie LI ; Jin-tian LI ; Jian-qing LIANG ; Ping TIAN ; Rong HU ; Xu-chao DONG ; Mei-hao XUE ; Long-xin XU
Chinese Traditional Patent Medicine 2025;47(9):2894-2901
AIM To investigate the tumor-suppressive mechanism of Guiqi Yiyuan Extract combined with cisplatin in Lewis lung cancer mice.METHODS Ten intact C57BL/6J mice were assigned to the blank group.Sixty additional mice were developed into Lewis lung cancer models bearing transplanted tumor and subsequently allocated into the model group,the cisplatin group(5 mg/kg),the high-dose Guiqi Yiyuan Extract group(6.6 g/kg),and the low-dose,medium-dose and high-dose Guiqi Yiyuan Extract combined with cisplatin group(1.6,3.3,6.6 g/kg+5 mg/kg),with 10 mice in each group.Mice in the blank and model groups received saline via daily gavage,while treatment groups were administered Guiqi Yiyuan Extract orally(once daily),and cisplatin injection intraperitoneally(once every other day).After 14 days of drug administration,mice were euthanized for endpoint analysis.The following assessments were conducted:general health status and body weight changes monitored throughout the study period;tumor excision and weighing for inhibition rate calculation;histopathological examination of tumors via hematoxylin-eosin(HE)staining;serum quantification of IL-1 β,IL-18 and HMGB1 by ELISA;ultrastructural analysis of tumor cell death using transmission electron microscopy(TEM);spatial localization of TXNIP and GSDMD-N in tumor sections via immunofluorescence(IF);and Western blot detection of TXNIP,NLRP3,Caspase-1,cleaved Caspase-1,GSDMD,GSDMD-N protein expressions in tumor tissues.RESULTS Compared to the model group,the cisplatin group and all combination therapy groups exhibited significant reduction in tumor weight(P<0.05)and increased tumor suppression rate;enhanced tumor tissue necrosis with characteristic pyroptotic morphology;elevated serum levels of IL-1β,IL-18 and HMGB1(P<0.05);and upregulated expressions of pyroptosis-associated proteins TXNIP,NLRP3,Caspase-1,cleaved Caspase-1,GSDMD and GSDMD-N(P<0.05).The high dose combination group demonstrated optimal therapeutic efficacy(P<0.05).CONCLUSION Guiqi Yiyuan Extract enhances cisplatin sensitivity,demonstrating synergistic anti-tumor effects in Lewis lung carcinoma-bearing mice.This combinatorial therapeutic effect likely involves modulation of the TXNIP/NLRP3/Caspase-1/GSDMD pathway.
8.Investigation on ventilator use and management in secondary and tertiary medical institutions in Sichuan Province
Zheng-hua LIANG ; Si-mei WANG ; Qiu-yu LIU ; Jin-long XU ; Ze-fang LIU ; Dan WEN
Chinese Medical Equipment Journal 2025;46(3):75-80
Objective To investigate the current situation of the ventilator use and management in secondary and tertiary medical institutions in Sichuan Province to provide references for management and training of ventilator users.Methods A questionnaire survey involving in 235 nurses from 13 secondary and tertiary medical institutions in Sichuan Province was conducted in terms of general information of the respondents,pipeline connection and parameter setup of ventilators,cleaning,sterilization and maintenance of ventilators,identification and treatment of ventilator alarms and hospital-acquired infection prevention and control.Results The results showed 20.4%of the respondents were nurses from critical care departments,and 79.6%of the respondents underwent the training for using the ventilator in their department;91.9%of the respondents could conduct ventilator self-testing by connecting the simulated lungs after the ventilator was switched on;66.4%of the respondents indicated that the initial parameters of the ventilator were set by the doctor;60.9%of the respondents proved that the performance monitoring and routine maintenance of the ventilator were carried out by the nurse;63.4%of the respondents showed disposable lines were commonly used in the departments.There were 89.8%of the respondents said the daily sterilization and management of the ventilator were performed by the nurse;46.0%of the respondents expressed the external surface of the ventilator was disinfected mainly with gamma disinfectant wipes;44.7%of the respondents indicated the external surface of the ventilator was sterilized every day;48.5%of the respondents said the internal airway of the ventilator was disinfected;57.0%of the respondents proved the disinfection was conducted after the expiratory flow sensors were used by any patient.There were 74.5%of the respondents that had paid attention to the ventilator waveform,and by the ventilator waveform only 21.3%were correct in determining whether there was secretion or fluid in the circuit and 22.1%in clarifying whether there was air leakage in the circuit.There were 59.1%of the respondents indicated that the closed suction tube was replaced once every 24 h;71.1%of the respondents could perform airbag pressure monitoring by the special pressure gauge.Conclusion Most of the nurses from secondary and tertiary medical institutions in Sichuan Province can use ventilators correctly,who have problems in disinfection specifications,infection prevention and control or recognition of ventilation waveform.It's suggested the training be strengthened to enhance the clinical nursing staffs in ventilator management.[Chinese Medical Equipment Journal,2025,46(3):75-80]
9.Quality inspection of ultrasound soft tissue cutting hemostatic equipment
Jing HUANG ; Qi-di SUN ; Ao-wen DUAN ; Li XU ; Heng-yu LONG ; Hai-jiang ZHU ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(10):49-53
Objective To carry out quality inspection of the ultrasound soft tissue cutting hemostatic equipment to ensure its safety and effectiveness.Methods Five brands of ultrasound soft tissue cutting hemostatic equipment were selected and noted as test equipment A,test equipment B,test equipment C,test equipment D and test equipment E,which underwent quality inspection in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current based on YY/T 0644-2008 Ultrasonics-surgical systems—Measurement and declaration of the basic output characteristics,YY/T 1750-2020 Ultrasonic surgical equipmetn for soft tissue excision and hemostasia and GB 9706.1-2020 Medical electrical equipment—Part 1:General requirements for basic safety and essential performance.Results The test data of the five brands in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current met the technical requirements of YY/T 0644-2008,YY/T 1750-2020,GB 9706.1-2020.Conclusion The quality inspection of the ultrasound soft tissue cutting hemostatic equipment contributes to enhancing the accuracy and stability of the equipment and decreasing the risk during its clinical application.[Chinese Medical Equipment Journal,2025,46(10):49-53]
10.Investigation on ventilator use and management in secondary and tertiary medical institutions in Sichuan Province
Zheng-hua LIANG ; Si-mei WANG ; Qiu-yu LIU ; Jin-long XU ; Ze-fang LIU ; Dan WEN
Chinese Medical Equipment Journal 2025;46(3):75-80
Objective To investigate the current situation of the ventilator use and management in secondary and tertiary medical institutions in Sichuan Province to provide references for management and training of ventilator users.Methods A questionnaire survey involving in 235 nurses from 13 secondary and tertiary medical institutions in Sichuan Province was conducted in terms of general information of the respondents,pipeline connection and parameter setup of ventilators,cleaning,sterilization and maintenance of ventilators,identification and treatment of ventilator alarms and hospital-acquired infection prevention and control.Results The results showed 20.4%of the respondents were nurses from critical care departments,and 79.6%of the respondents underwent the training for using the ventilator in their department;91.9%of the respondents could conduct ventilator self-testing by connecting the simulated lungs after the ventilator was switched on;66.4%of the respondents indicated that the initial parameters of the ventilator were set by the doctor;60.9%of the respondents proved that the performance monitoring and routine maintenance of the ventilator were carried out by the nurse;63.4%of the respondents showed disposable lines were commonly used in the departments.There were 89.8%of the respondents said the daily sterilization and management of the ventilator were performed by the nurse;46.0%of the respondents expressed the external surface of the ventilator was disinfected mainly with gamma disinfectant wipes;44.7%of the respondents indicated the external surface of the ventilator was sterilized every day;48.5%of the respondents said the internal airway of the ventilator was disinfected;57.0%of the respondents proved the disinfection was conducted after the expiratory flow sensors were used by any patient.There were 74.5%of the respondents that had paid attention to the ventilator waveform,and by the ventilator waveform only 21.3%were correct in determining whether there was secretion or fluid in the circuit and 22.1%in clarifying whether there was air leakage in the circuit.There were 59.1%of the respondents indicated that the closed suction tube was replaced once every 24 h;71.1%of the respondents could perform airbag pressure monitoring by the special pressure gauge.Conclusion Most of the nurses from secondary and tertiary medical institutions in Sichuan Province can use ventilators correctly,who have problems in disinfection specifications,infection prevention and control or recognition of ventilation waveform.It's suggested the training be strengthened to enhance the clinical nursing staffs in ventilator management.[Chinese Medical Equipment Journal,2025,46(3):75-80]

Result Analysis
Print
Save
E-mail