1.A new classification of atlas fracture based on computed tomography: reliability, reproducibility, and preliminary clinical significance
Yun-lin CHEN ; Wei-yu JIANG ; Wen-jie LU ; Xu-dong HU ; Yang WANG ; Wei-hu MA
Asian Spine Journal 2025;19(1):3-9
Methods:
Seventy-five patients with atlas fracture were included from January 2015 to December 2020. Based on the anatomy of the fracture line, atlas fractures were divided into three types. Each type was divided into two subtypes according to the fracture displacement. Unweighted Cohen kappa coefficients were applied to evaluate the reliability and reproducibility.
Results:
According to the new classification, 17 cases of type A1, 12 of type A2, seven of type B1, 13 of type B2, 12 of type C1, and 14 of type C2 were identified. The K-values of the interobserver and intraobserver reliability were 0.846 and 0.912, respectively, for the new classification. The K-values of interobserver reliability for types A, B, and C were 0.843, 0.799, and 0.898, respectively. The K-values of intraobserver reliability for types A, B, and C were 0.888, 0.910, and 0.935, respectively. The mean K-values of the interobserver and intraobserver reliability for subtypes were 0.687 and 0.829, respectively.
Conclusions
The new classification of atlas fractures can cover nearly all atlas fractures. This system is the first to evaluate the severity of fractures based on the C1 articular facet and fracture displacement and strengthen the anatomy ring of the atlas. It is concise, easy to remember, reliable, and reproducible.
2.A new classification of atlas fracture based on computed tomography: reliability, reproducibility, and preliminary clinical significance
Yun-lin CHEN ; Wei-yu JIANG ; Wen-jie LU ; Xu-dong HU ; Yang WANG ; Wei-hu MA
Asian Spine Journal 2025;19(1):3-9
Methods:
Seventy-five patients with atlas fracture were included from January 2015 to December 2020. Based on the anatomy of the fracture line, atlas fractures were divided into three types. Each type was divided into two subtypes according to the fracture displacement. Unweighted Cohen kappa coefficients were applied to evaluate the reliability and reproducibility.
Results:
According to the new classification, 17 cases of type A1, 12 of type A2, seven of type B1, 13 of type B2, 12 of type C1, and 14 of type C2 were identified. The K-values of the interobserver and intraobserver reliability were 0.846 and 0.912, respectively, for the new classification. The K-values of interobserver reliability for types A, B, and C were 0.843, 0.799, and 0.898, respectively. The K-values of intraobserver reliability for types A, B, and C were 0.888, 0.910, and 0.935, respectively. The mean K-values of the interobserver and intraobserver reliability for subtypes were 0.687 and 0.829, respectively.
Conclusions
The new classification of atlas fractures can cover nearly all atlas fractures. This system is the first to evaluate the severity of fractures based on the C1 articular facet and fracture displacement and strengthen the anatomy ring of the atlas. It is concise, easy to remember, reliable, and reproducible.
3.A new classification of atlas fracture based on computed tomography: reliability, reproducibility, and preliminary clinical significance
Yun-lin CHEN ; Wei-yu JIANG ; Wen-jie LU ; Xu-dong HU ; Yang WANG ; Wei-hu MA
Asian Spine Journal 2025;19(1):3-9
Methods:
Seventy-five patients with atlas fracture were included from January 2015 to December 2020. Based on the anatomy of the fracture line, atlas fractures were divided into three types. Each type was divided into two subtypes according to the fracture displacement. Unweighted Cohen kappa coefficients were applied to evaluate the reliability and reproducibility.
Results:
According to the new classification, 17 cases of type A1, 12 of type A2, seven of type B1, 13 of type B2, 12 of type C1, and 14 of type C2 were identified. The K-values of the interobserver and intraobserver reliability were 0.846 and 0.912, respectively, for the new classification. The K-values of interobserver reliability for types A, B, and C were 0.843, 0.799, and 0.898, respectively. The K-values of intraobserver reliability for types A, B, and C were 0.888, 0.910, and 0.935, respectively. The mean K-values of the interobserver and intraobserver reliability for subtypes were 0.687 and 0.829, respectively.
Conclusions
The new classification of atlas fractures can cover nearly all atlas fractures. This system is the first to evaluate the severity of fractures based on the C1 articular facet and fracture displacement and strengthen the anatomy ring of the atlas. It is concise, easy to remember, reliable, and reproducible.
4.Therapeutic effects of paeoniflorin on thromboangiitis obliterans model rats by regulating PI3K/AKT/NF-κB signaling pathway
Ya-Na WANG ; Xiao-Lin XU ; Wen-Hua MA ; Luo-Fang CUI ; Li LIU ; Lin-Li XU ; Yan ZHANG ; Xiu-Lei ZHAO
The Chinese Journal of Clinical Pharmacology 2024;40(6):854-858
Objective To investigate the therapeutic effect and mechanism of paeoniflorin(PAE)on thrombosis angiitis obliterans(TAO)in rats.Methods TAO rat model was established by sodium laurate injection.Rats were randomly divided into sham operation group(intraperitoneal injection of 0.9%NaCl),model group(intraperitoneal injection of 0.9%NaCl),experimental-L,-H groups(intraperitoneal injection of PAE 5,20 mg·kg-1·d-1),experimental-H+agonist group(intraperitoneal injection of 20 mg·kg-1·d-1 PAE+caudal vein injection of 10 ng·mL-1·kg 1·d-1 740 Y-P).Thrombin time(TT)was measured by magnetic bead coagulation;the levels of interleukin(IL)-1 β and endothelin 1(ET-1)were detected by enzyme-linked immunosorbent assay kit;the expression levels of phosphatidylinositol 3-kinase(PI3K),phosphorylated-PI3K(p-PI3 K),protein kinase B(AKT),p-AKT,nuclear factor(NF)-κB p65,p-NF-κB p65 were detected by Western blotting.Results The TT of sham operation group,model group,experimental-L,-H groups and experimental-H+agonist group were(14.88±1.32),(10.02±0.95),(12.65±1.22),(14.70±1.36)and(10.64±1.21)s;IL-1β were(154.23±13.45),(356.69±31.17),(268.62±23.58),(199.64±20.87)and(337.48±31.46)pg·mL-1;ET-1 were(6.78±0.68),(14.43±1.14),(11.23±1.07),(8.20±0.81)and(13.33±1.27)pg·mL-1;p-PI3K/PI3K were 0.36±0.04,0.76±0.07,0.59±0.05,0.44±0.04 and 0.69±0.07;p-AKT/AKT were 0.52±0.05,0.90±0.09,0.74±0.08,0.61±0.06 and 0.86±0.08;p-NF-κB p65/NF-κB p65 were 0.28±0.03,0.95±0.04,0.69±0.07,0.35±0.05 and 0.87±0.08,respectively.There were statistically significant differences between model group and sham operation group(all P<0.05);the above indexes in experimental-L group and experimental-H group were significantly different from those in medel group(all P<0.05);the above indexes in experimental-H+agonist group were significantly different from those in experimental-H group(all P<0.05).Conclusion PAE may improve disease progression in TAO rats by inhibiting the PI3K/AKT/NF-κB signaling pathway.
5.Exploration on bioactive equivalent combinatorial components of Xiaoke formula and its mechanism based on insulin resistance mice
Jian ZHANG ; Wen-juan MA ; Lin-jie DONG ; Jiang-lan LONG ; Yu ZHANG ; Dan YAN
Acta Pharmaceutica Sinica 2024;59(6):1698-1705
Xiaoke formula (XKF) is a classic formula for the treatment of insulin resistance (IR), but there is still unclear on bioactive equivalent combinatorial components (BECC) of XKF. In this study, based on the previous research of our team, three components, berberine, astragaloside IV and chlorogenic acid, were selected as the BECC of XKF, and their efficacy and mechanism were investigated. A high-fat diet-induced IR mouse model was used to detect blood glucose, insulin sensitivity, lipid metabolism, immune & inflammatory factors, etc., and staining of pathology sections was used to detect histopathological changes. Network pharmacology was used to predict the potential targets and signaling pathways of XKF and its BECC, and the results of the network were verified by Western blot. The animal welfare and experimental procedures followed the regulations of the Laboratory Animal Ethics Committee of Beijing MDKN Biotech Company (MDKN-2023-019). The results showed that BECC, which was composed of berberine, astragaloside IV and chlorogenic acid in the ratio of the original formula of XKF, was comparable to XKF in improving the glycemia, insulin sensitivity, histopathological damage, dyslipidemia, and immuno-inflammation in IR mice. The results of network pharmacology and Western blot suggested that the BECC of XKF and XKF might alleviate IR by promoting the activation of hepatic phosphatidylinositol 3-kinase (PI3K), phosphorylation of protein kinase B (AKT), and inhibiting the expression of glucose-6-phosphate phosphatase (G6PC) and phosphoenolpyruvate carboxykinase 1 (PCK1), the key limiting enzymes of hepatic gluconeogenesis. The above results suggest that berberine, astragaloside IV and chlorogenic acid can be used as the potential BECC of XKF to improve IR, and can regulate lipid metabolism, immuno-inflammation, and promote hepatic PI3K/AKT signaling to inhibit hepatic gluconeogenesis, regulate glucose homeostasis, and improve IR in mice.
6.Physical performance evaluated by the timed up and go test and its correlation with sleep in the elderly in China
Yu DU ; Xinxin MA ; Jingjing DUAN ; Jianhong XIAO ; Jian LIN ; Xiong'ang HUANG ; Chao LIU ; Binbin WANG ; Ting DENG ; Tao CHEN ; Wen SU
Chinese Journal of Geriatrics 2024;43(1):29-33
Objective:To investigate the effect of sleep on physical performance and the correlation between sleep quality and physical performance in the elderly.Methods:In this prospective multicenter case-control study, 472 elderly people aged 60-80 years were recruited from three regions in China, Beijing, Tianjin, and Hainan Province.Basic information of study participants was collected through face-to-face interviews, and physical performance of study participants was assessed by the time up and go(TUG)test on site, with 106 cases(22.5%)in the normal physical performance group and 366 cases(77.5%)in the abnormal group.The Pittsburgh Sleep Quality Index(PSQI)and the Epworth Sleepiness Scale(ESS)were applied to assess sleep quality of study subjects.Correlation analysis was performed to examine factors affecting subjects' physical performance.Results:Age, history of alcohol consumption, BMI, past medical history, the ESS score, daytime sleepiness, and some components of PSQI, such as sleep quality, sleep efficiency, sleep disturbances, use of sleeping drugs and daytime dysfunction, were influencing factors of the TUG score.Two components of PSQI, sleep duration and habitual sleep efficiency, and the ESS score were positively correlated with physical performance.Logistic regression analysis showed that risk factors for decreased physical performance in the elderly included increased age( OR=1.125, 95% CI: 1.083-1.168, P<0.01), history of alcohol consumption( OR=0.482, 95% CI: 0.384-0.605, P<0.001), abnormally high body mass index( OR=1.663, 95% CI: 1.340-2.063, P<0.01), hyperlipemia( OR=0.156, 95% CI: 0.077-0.318, P<0.01), digestive system diseases( OR=0.154, 95% CI: 0.044-0.532, P<0.01), use of sleeping drugs( OR=0.415, 95% CI: 0.202-0.854, P<0.05), daytime sleepiness( OR=4.234, 95% CI: 2.800-6.403, P<0.01), a high habitual sleep efficiency score of PSQI( OR=1.425, 95% CI: 1.214-1.672, P<0.01)and a high sleep disturbances score in PSQI( OR=3.356, 95% CI: 2.337-4.819, P<0.01). Conclusions:The incidence of physical performance decline is high in the elderly.There is a correlation between physical performance and sleep quality.
7.Expert consensus on digital intraoral scanning technology
Jie YOU ; Wenjuan YAN ; Liting LIN ; Wen-Zhen GU ; Yarong HOU ; Wei XIAO ; Hui YAO ; Yaner LI ; Lihui MA ; Ruini ZHAO ; Junqi QIU ; Jianzhang LIU ; Yi ZHOU
Journal of Prevention and Treatment for Stomatological Diseases 2024;32(8):569-577
Digital intraoral scanning is a hot topic in the field of oral digital technology.In recent years,digital intra-oral scanning has gradually become the mainstream technology in orthodontics,prosthodontics,and implant dentistry.The precision of digital intraoral scanning and the accuracy and stitching of data collection are the keys to the success of the impression.However,the operators are less familiar with the intraoral scanning characteristics,imaging process-ing,operator scanning method,oral tissue specificity of the scanned object,and restoration design.Thus far,no unified standard and consensus on digital intraoral scanning technology has been achieved at home or abroad.To deal with the problems encountered in oral scanning and improve the quality of digital scanning,we collected common expert opin-ions and sought to expound the causes of scanning errors and countermeasures by summarizing the existing evidence.We also describe the scanning strategies under different oral impression requirements.The expert consensus is that due to various factors affecting the accuracy of digital intraoral scanning and the reproducibility of scanned images,adopting the correct scanning trajectory can shorten clinical operation time and improve scanning accuracy.The scanning trajec-tories mainly include the E-shaped,segmented,and S-shaped methods.When performing fixed denture restoration,it is recommended to first scan the abutment and adjacent teeth.When performing fixed denture restoration,it is recommend-ed to scan the abutment and adjacent teeth first.Then the cavity in the abutment area is excavated.Lastly,the cavity gap was scanned after completing the abutment preparation.This method not only meets clinical needs but also achieves the most reliable accuracy.When performing full denture restoration in edentulous jaws,setting markers on the mucosal tissue at the bottom of the alveolar ridge,simultaneously capturing images of the vestibular area,using different types of scanning paths such as Z-shaped,S-shaped,buccal-palatal and palatal-buccal pathways,segmented scanning of dental arches,and other strategies can reduce scanning errors and improve image stitching and overlap.For implant restora-tion,when a single crown restoration is supported by implants and a small span upper structure restoration,it is recom-mended to first pre-scan the required dental arch.Then the cavity in the abutment area is excavated.Lastly,scanning the cavity gap after installing the implant scanning rod.When repairing a bone level implant crown,an improved indi-rect scanning method can be used.The scanning process includes three steps:First,the temporary restoration,adjacent teeth,and gingival tissue in the mouth are scanned;second,the entire dental arch is scanned after installing a standard scanning rod on the implant;and third,the temporary restoration outside the mouth is scanned to obtain the three-di-mensional shape of the gingival contour of the implant neck,thereby increasing the stability of soft tissue scanning around the implant and improving scanning restoration.For dental implant fixed bridge repair with missing teeth,the mobility of the mucosa increases the difficulty of scanning,making it difficult for scanners to distinguish scanning rods of the same shape and size,which can easily cause image stacking errors.Higher accuracy of digital implant impres-sions can be achieved by changing the geometric shape of the scanning rods to change the optical curvature radius.The consensus confirms that as the range of scanned dental arches and the number of data concatenations increases,the scanning accuracy decreases accordingly,especially when performing full mouth implant restoration impressions.The difficulty of image stitching processing can easily be increased by the presence of unstable and uneven mucosal mor-phology inside the mouth and the lack of relatively obvious and fixed reference objects,which results in insufficient ac-curacy.When designing restorations of this type,it is advisable to carefully choose digital intraoral scanning methods to obtain model data.It is not recommended to use digital impressions when there are more than five missing teeth.
8.CD97 inhibits osteoclast differentiation via Rap1a/ERK pathway under compression
Wang WEN ; Wang QIAN ; Sun SHIYING ; Zhang PENGFEI ; Li YUYU ; Lin WEIMIN ; Li QIWEN ; Zhang XIAO ; Ma ZHE ; Lu HAIYAN
International Journal of Oral Science 2024;16(1):134-144
Acceleration of tooth movement during orthodontic treatment is challenging,with osteoclast-mediated bone resorption on the compressive side being the rate-limiting step.Recent studies have demonstrated that mechanoreceptors on the surface of monocytes/macrophages,especially adhesion G protein-coupled receptors(aGPCRs),play important roles in force sensing.However,its role in the regulation of osteoclast differentiation remains unclear.Herein,through single-cell analysis,we revealed that CD97,a novel mechanosensitive aGPCR,was expressed in macrophages.Compression upregulated CD97 expression and inhibited osteoclast differentiation;while knockdown of CD97 partially rescued osteoclast differentiation.It suggests that CD97 may be an important mechanosensitive receptor during osteoclast differentiation.RNA sequencing analysis showed that the Rap1a/ERK signalling pathway mediates the effects of CD97 on osteoclast differentiation under compression.Consistently,we clarified that administration of the Rap1a inhibitor GGTI298 increased osteoclast activity,thereby accelerating tooth movement.In conclusion,our results indicate that CD97 suppresses osteoclast differentiation through the Rap1a/ERK signalling pathway under orthodontic compressive force.
9.Roles of hepatic Dishevelled/Egl-10/pleckstrin domain-containing protein 5/mammalian target of rapamycin complex 1 signaling axis on the development of non-alcoholic fatty liver disease
Lin XU ; Xi-Wen XIONG ; Zun LI ; Rong HUANG ; Hong-Hui MA ; Jie MA
Acta Anatomica Sinica 2024;55(3):295-301
Objective To investigate the effect of hepatic Dishevelled/Egl-10/pleckstrin domain-containing protein 5(DEPDC5)/mammalian target of rapamycin complex 1(mTORC1)on nonalcoholic fatty liver disease by establishing a high-fat diet feeding model of Depdc5 gene hepatocyte specific knockout mice.Methods Depdc5flox/flox mice were constructed and mated with Alumin-Cre mice to obtain Depdc5flox/flox;Alb-Cre mice(LKO),Depdc5flox/flox mice were as control(Loxp).Totally 32 male mice aged 2-3 months were randomly divided into high-fat-diet LKO group,high-fat-diet Loxp control group,high-fat-diet+rapamycin LKO group,and high-fat-diet+rapamycin Loxp control group,with 8 mice in each group.Liver serum biochemistry,lipid content,protein,mRNA and pathological sections were detected;Graphpad prism 8 software was used for statistical analysis.Results High-fat-diet induced liver steatosis in Loxp mice,while LKO mice were protected from steatosis but had aggravated liver injury.Rapamycin treatment attenuated the hyperactivation of mTORC1 pathway caused by Depdc5 knockout,alleviated the liver steatosis in Loxp mice and liver injury in LKO mice.Conclusion Deletion of Depdc5 gene protects mice from high-fat-diet induced liver steatosis and rapamycin treatment might be used to improve liver injury caused by DEPDC5 loss of function.
10.Standardized operational protocol for the China Human Brain Bank Consortium(2nd edition)
Xue WANG ; Zhen CHEN ; Juan-Li WU ; Nai-Li WANG ; Di ZHANG ; Juan DU ; Liang YU ; Wan-Ru DUAN ; Peng-Hao LIU ; Han-Lin ZHANG ; Can HUANG ; Yue-Shan PIAO ; Ke-Qing ZHU ; Ai-Min BAO ; Jing ZHANG ; Yi SHEN ; Chao MA ; Wen-Ying QIU ; Xiao-Jing QIAN
Acta Anatomica Sinica 2024;55(6):734-745
Human brain banks use a standardized protocol to collect,process and store post-mortem human brains and related tissues,along with relevant clinical information,and to provide the tissue samples and data as a resource to foster neuroscience research according to a standardized operating protocols(SOP).Human brain bank serves as the foundation for neuroscience research and the diagnosis of neurological disorders,highlighting the crucial rule of ensuring the consistency of standardized quality for brain tissue samples.The first version of SOP in 2017 was published by the China Human Brain Bank Consortium.As members increases from different regions in China,a revised SOP was drafted by experts from the China Human Brain Bank Consortium to meet the growing demands for neuroscience research.The revised SOP places a strong emphasis on ethical standards,incorporates neuropathological evaluation of brain regions,and provides clarity on spinal cord sampling and pathological assessment.Notable enhancements in this updated version of the SOP include reinforced ethical guidelines,inclusion of matching controls in recruitment,and expansion of brain regions to be sampled for neuropathological evaluation.


Result Analysis
Print
Save
E-mail