1.Environmental sustainability in healthcare: impacts of climate change, challenges and opportunities.
Ethan Yi-Peng KOH ; Wan Fen CHAN ; Hoon Chin Steven LIM ; Benita Kiat Tee TAN ; Cherlyn Tze-Mae ONG ; Prit Anand SINGH ; Michelle Bee Hua TAN ; Marcus Jin Hui SIM ; Li Wen ONG ; Helena TAN ; Seow Yen TAN ; Wesley Chik Han HUONG ; Jonathan SEAH ; Tiing Leong ANG ; Jo-Anne YEO
Singapore medical journal 2025;66(Suppl 1):S47-S56
Environmental damage affects many aspects of healthcare, from extreme weather events to evolving population disease. Singapore's healthcare sector has the world's second highest healthcare emissions per capita, hampering the nation's pledge to reduce emissions by 2030 and achieve net zero emissions by 2050. In this review, we provide an overview of the impact environmental damage has on healthcare, including facilities, supply chain and human health, and examine measures to address healthcare's impact on the environment. Utilising the 'R's of sustainability - rethinking, reducing/refusing, reusing/repurposing/reprocessing, repairing, recycling and research - we have summarised the opportunities and challenges across medical disciplines. Awareness and advocacy to adopt strategies at institutional and individual levels is needed to revolutionise our environmental footprint and improve healthcare sustainability. By leveraging evidence from ongoing trials and integrating sustainable practices, our healthcare system can remain resilient against environment-driven challenges and evolving healthcare demands while minimising further impacts of environmental destruction.
Humans
;
Climate Change
;
Delivery of Health Care
;
Singapore
;
Conservation of Natural Resources
;
Sustainable Development
;
Environment
2.Clinical study on the effectiveness of bone acupuncture for alleviating pain and improving function in patients with degenerative lumbar spinal stenosis.
Chang-Xiao HAN ; Min-Shan FENG ; Jing-Hua GAO ; Xun-Lu YIN ; Guang-Wei LIU ; Hai-Bao WEN ; Jing LI ; Bo-Chen PENG ; Li-Guo ZHU
China Journal of Orthopaedics and Traumatology 2025;38(2):152-156
OBJECTIVE:
To assess the effectiveness of bone acupuncture in improving pain and function in degenerative lumbar spinal stenosis (DLSS) and compare it with Jiaji acupuncture.
METHODS:
From January to December 2023, 80 DLSS patients were treated with acupuncture and divided into bone acupuncture and Jiaji acupuncture groups. Among them, 40 patients in the bone acupuncture group included 15 males and 25 females, with a mean age of (60.60±6.98) years old;anthor 40 patients in the Jiaji acupuncture group included 16 males and 24 females, with a mean age of (61.48±9.55) years old. The Roland Morris disability questionnaire(RMDQ), walking distance, visual analogue scale(VAS), and the MOS item short from health survey(SF-36) of two groups at baseline, 2 weeks, 4 weeks, and 12 weeks post-treatment were compared.
RESULTS:
Eighty patients were followed up for 3 to 5 months with an average of (3.62±0.59) months. There was no significant differences in general data and the scores before treatment between two groups(P>0.05). The RMDQ scores in both groups decreased significantly at 2, 4 and 12 weeks after treatment compared with before treatment(P<0.05), at each time point after treatment, the decrease was more significant in the bone acupuncture group than in the Jiaji acupuncture group(P<0.05). The VAS of waist and leg in both groups was significantly lower at 2, 4 and 12 weeks after treatment that before treatment(P<0.05). At all time points after treatment, the waist VAS in the bone acupuncture group was reduced more significant than in the Jiaji acupuncture group(P<0.05);there was no significant difference in leg VAS at 2 and 12 weeks after treatment between two groups(P>0.05), the improvement was more significant in the bone acupuncture group in the 4 weeks after treatment than in the Jiaji acupuncture group. The SF-36 scores in both groups were significantly higher at 2, 4, and 12 weeks after treatment than before treatment(P<0.05);the SF-36 score raised more significant in the bone acupuncture group than in the Jiaji acupunture group(P<0.05). No significant difference in the walking distance between two groups at 2 weeks after treatment(P>0.05);the walking distance in the bone acupuncture group was significantly higher than that in the Jiaji acupuncture group at 4 and 12 weeks after treatment(P<0.05).
CONCLUSION
Bone-penetrating acupuncture moderately improves functional impairment, pain, and quality of life in patients with DLSS, showing better efficacy than Jiaji acupuncture.
Humans
;
Female
;
Male
;
Middle Aged
;
Acupuncture Therapy/methods*
;
Spinal Stenosis/physiopathology*
;
Aged
;
Lumbar Vertebrae/physiopathology*
;
Pain Management
3.Association of higher serum follicle-stimulating hormone levels with successful microdissection testicular sperm extraction outcomes in nonobstructive azoospermic men with reduced testicular volumes.
Ming-Zhe SONG ; Li-Jun YE ; Wei-Qiang XIAO ; Wen-Si HUANG ; Wu-Biao WEN ; Shun DAI ; Li-Yun LAI ; Yue-Qin PENG ; Tong-Hua WU ; Qing SUN ; Yong ZENG ; Jing CAI
Asian Journal of Andrology 2025;27(3):440-446
To investigate the impact of preoperative serum follicle-stimulating hormone (FSH) levels on the probability of testicular sperm retrieval, we conducted a study of nonobstructive azoospermic (NOA) men with different testicular volumes (TVs) who underwent microdissection testicular sperm extraction (micro-TESE). A total of 177 NOA patients undergoing micro-TESE for the first time from April 2019 to November 2022 in Shenzhen Zhongshan Obstetrics and Gynecology Hospital (formerly Shenzhen Zhongshan Urology Hospital, Shenzhen, China) were retrospectively reviewed. The subjects were divided into four groups based on average TV quartiles. Serum hormone levels in each TV group were compared between positive and negative sperm retrieval subgroups. Overall sperm retrieval rate was 57.6%. FSH levels (median [interquartile range]) were higher in the positive sperm retrieval subgroup compared with the negative outcome subgroup when average TV was <5 ml (first quartile [Q1: TV <3 ml]: 43.32 [17.92] IU l -1 vs 32.95 [18.56] IU l -1 , P = 0.048; second quartile [Q2: 3 ml ≤ TV <5 ml]: 31.31 [15.37] IU l -1 vs 25.59 [18.40] IU l -1 , P = 0.042). Elevated serum FSH levels were associated with successful micro-TESE sperm retrieval in NOA men whose average TVs were <5 ml (adjusted odds ratio [OR]: 1.06 per unit increase; 95% confidence interval [CI]: 1.01-1.11; P = 0.011). In men with TVs ≥5 ml, larger TVs were associated with lower odds of sperm retrieval (adjusted OR: 0.84 per 1 ml increase; 95% CI: 0.71-0.98; P = 0.029). In conclusion, elevated serum FSH levels were associated with positive sperm retrieval in micro-TESE in NOA men with TVs <5 ml. In men with TV ≥5 ml, increases in average TVs were associated with lower odds of sperm retrieval.
Humans
;
Male
;
Azoospermia/surgery*
;
Sperm Retrieval/statistics & numerical data*
;
Adult
;
Follicle Stimulating Hormone/blood*
;
Retrospective Studies
;
Testis/pathology*
;
Microdissection
;
Organ Size
4.Exploration of evaluation criteria based on the biological variation in the external quality assessment for basic semen analysis in China.
Xi-Yan WU ; Jin-Chun LU ; Xin-Hua PENG ; Jing-Liang HE ; Dao WANG ; Cong-Ling DAI ; Wen-Bing ZHU ; Gang LIU ; Wei-Na LI
Asian Journal of Andrology 2025;27(5):621-626
This study explores whether the current external quality assessment (EQA) level and acceptable bias for basic semen analysis in China are clinically useful. We collected data of semen EQA from Andrology laboratories in the Hunan Province (China) in 2022 and searched for data in the published literature from January 2000 to December 2023 in China. On the basis of these data, we analyzed the coefficients of variation and acceptable biases of different quality control materials for basic semen analysis through robust statistics. We compared these findings with quality specifications based on biological variation from optimal, desirable, and minimum levels of bias to seek a unified and more suitable semen EQA bias evaluation standard for China's national conditions. Different sources of semen quality control material exhibited considerable variation in acceptable biases among laboratories, ranging from 8.2% to 56.9%. A total of 50.0% of the laboratories met the minimum quality specifications for progressive motility (PR), whereas 100.0% and 75.0% of laboratories met only the minimum quality specifications for sperm concentration and total motility (nonprogressive [NP] + PR), respectively. The Z value for sperm concentration and PR+NP was equivalent to the desirable performance specification, whereas the Z value for PR was equivalent only to the minimum performance specification. This study highlights the feasibility of operating external quality assessment schemes for basic semen analysis using quality specifications based on biological variation. These specifications should be unified among external quality control (EQC) centers based on biological variation.
Semen Analysis/standards*
;
Humans
;
China
;
Male
;
Quality Control
;
Sperm Motility
;
Sperm Count/standards*
5.Clinical and genetic characteristics of congenital adrenal hyperplasia: a retrospective analysis.
Cai-Jun WANG ; Ya-Wei ZHANG ; Da-Peng LIU ; Juan JIN ; Zhao-Hui LI ; Jing GUO ; Yao-Dong ZHANG ; Hai-Hua YANG ; Wen-Qing KANG
Chinese Journal of Contemporary Pediatrics 2025;27(11):1367-1372
OBJECTIVES:
To study the clinical and genetic characteristics of children with congenital adrenal hyperplasia (CAH).
METHODS:
Clinical data, laboratory findings, and genetic test results of 63 children diagnosed with CAH at Henan Children's Hospital from January 2017 to December 2024 were retrospectively reviewed.
RESULTS:
Of the 63 patients, the mean age at the first visit was (21 ± 14) days; 29 (46%) were of male sex and 34 (54%) were of female sex. The predominant clinical manifestations were poor weight gain or weight loss (92%, 58/63), poor feeding (84%, 53/63), skin hyperpigmentation (83%, 52/63), and female external genital anomalies (100%, 34/34). Laboratory abnormalities included hyponatremia (87%, 55/63), hyperkalemia (68%, 43/63), metabolic acidosis (68%, 43/63), and markedly elevated 17-hydroxyprogesterone (92%, 58/63), testosterone (89%, 56/63), and adrenocorticotropic hormone (81%, 51/63). Among 49 patients who underwent genetic testing, CYP21A2 variants were identified in 90% (44/49), with c.293-13A/C>G (33%, 30/91) and large deletions/gene conversions (29%, 26/91) being the most frequent; STAR (8%, 4/49) and HSD3B2 (2%, 1/49) variants were also detected. Following hormone replacement therapy, electrolyte disturbances were corrected in 57 cases, with significant reductions in 17-hydroxyprogesterone, adrenocorticotropic hormone, and testosterone levels (P<0.001).
CONCLUSIONS
CAH presenting in neonates or young infants is characterized by electrolyte imbalance, external genital anomalies, and abnormal hormone levels. Genetic testing enables definitive subtype classification; in CYP21A2-related CAH, c.293-13A/C>G is a hotspot variant. These findings underscore the clinical value of genetic testing for early diagnosis and genetic counseling in CAH. Citation:Chinese Journal of Contemporary Pediatrics, 2025, 27(11): 1367-1372.
Humans
;
Adrenal Hyperplasia, Congenital/diagnosis*
;
Male
;
Female
;
Retrospective Studies
;
Infant
;
Infant, Newborn
6.Effect of high ligation of spermatic vein on leukocytes in expressed prostate secretion of patients with chronic prostatitis and varicocele.
Ji-Yang DING ; Peng ZHANG ; Chun-Hua NIU ; Hai-Yong LI ; Wen-Zhu XU ; Ying-Chen ZHANG ; Gang MA
National Journal of Andrology 2025;31(4):319-322
OBJECTIVE:
To investigate the effect of laparoscopic high ligation of spermatic cord vein in patients with chronic prostatitis and varicocele prostatitis.
METHODS:
A total of 90 varicocele patients were selected from January 2016 to December 2020, including 33 patients with chronic prostatitis. Changes of white blood cell count, National Institutes of Health chronic prostatitis symptom index (NIH-CPSI) score and serum testosterone level in the expressed prostate secretion (EPS) were observed before and after the operation of laparoscopic high ligation of spermatic vein.
RESULTS:
All patients were followed up three months after the surgery. There was no significant difference in the white blood cell counts in EPS, NIH-CPSI score, and serum testosterone level in patients with varicocele-only who underwent high ligation surgery after the operation. However, the white blood cell count in the EPS of patients with chronic prostatitis was lower than that before 3 months of operation ( [12.39±4.23]×109/L vs [21.36±5.05]×109/L). The NIH-CPSI score was significantly lower than that before operation ( [12.71±6.21] vs [26.76±8.43]). And the serum testosterone level was higher than that before operation ([4.34±1.77]ng/ml vs [2.36±1.05]ng/ml).
CONCLUSION
Laparoscopic high ligation of the spermatic vein in patients with chronic prostatitis and varicocele could effectively reduce the number of white blood cells in the EPS, boost the level of serum testosterone and improves symptoms of chronic prostatitis.
Male
;
Humans
;
Varicocele/surgery*
;
Prostatitis/blood*
;
Ligation
;
Spermatic Cord/blood supply*
;
Testosterone/blood*
;
Chronic Disease
;
Prostate/metabolism*
;
Veins/surgery*
;
Leukocyte Count
;
Leukocytes
;
Laparoscopy
;
Adult
7.A preclinical evaluation and first-in-man case for transcatheter edge-to-edge mitral valve repair using PulveClip® transcatheter repair device.
Gang-Jun ZONG ; Jie-Wen DENG ; Ke-Yu CHEN ; Hua WANG ; Fei-Fei DONG ; Xing-Hua SHAN ; Jia-Feng WANG ; Ni ZHU ; Fei LUO ; Peng-Fei DAI ; Zhi-Fu GUO ; Yong-Wen QIN ; Yuan BAI
Journal of Geriatric Cardiology 2025;22(2):265-269
8.Nontarget Screening and Identification of Novel Per-and Polyfluoroalkyl Substances in Cosmetics Using Ultra-High Performance Liquid Chromatography-High-Resolution Mass Spectrometry
Xin-Ling LI ; Tao YANG ; Wen-Yao LIANG ; Jian-Hua TAN ; Xian-Zhi PENG
Chinese Journal of Analytical Chemistry 2025;53(4):640-651,中插23-中插28
Cosmetics may be an important source of human exposure to per-and polyfluoroalkyl substances(PFASs),posing risks to human health.In this study,a nontarget screening method for PFASs in cosmetics was developed using ultra-high performance liquid chromatography-high-resolution mass spectrometry(UHPLC-Q-Orbitrap HRMS)based on the Kendrick mass defect(KMD).The sample was extracted by ultrasonic assisted extraction prior to being analyzed by UHPLC-Q-Orbitrap HRMS.Acquisition of HRMS data was achieved in both full scan and data-dependent(Full MS/dd MS2)mode.The data collected by HRMS were imported into an in-lab built R script for processing.Samples retained the mass spectra peaks with KMD values in the range of 0.85-1 or 0-0.15 for in-and out-of-library matching;when KMD deviation(δKMD)<0.001 and CF 2 mass error(δMS)<15 ppm,it was considered as a potential PFASs homologues.According to matches of parent ions(MS),fragment ions(MS2)and retention time(RT)with the in-house built PFASs database,the screened and identified potential PFASs were categorized to 5 confidence levels(CL1-CL5).A total of 15 kinds of PFASs homologues with confidence level of CL3 and above were screened from 13 cosmetics products and 8 cosmetic raw materials,including perfluoroalkyl alcohol,hydroperfluoroalkyl sulfonic acid,chloroperfluoroalkyl sulfonic acid,etc.with concentrations ranging from 1.9 ng/g to 98.1 ng/g.The nontarget screening method could be used to screen and identify PFASs homologues feasibly and therefore provided data basis for management and control of PFASs addition in cosmetics.
9.Research Progress on Electrochemical Sensing Techniques for Detection of Telomerase Activity
Hai-Tang YANG ; Peng-Hua SHU ; Wen-Lin LIU ; Wen-Bo MA ; Zi-Jun YANG ; Zhi-Feng DENG ; Xin-Yun ZHANG ; Wei WEI
Chinese Journal of Analytical Chemistry 2025;53(6):864-874
The telomere structure in the cell nucleus is crucial for maintaining the stability and functions of chromosomes.Telomerase is a ribonucleoprotein reverse transcriptase,which catalyzes the elongation of telomeres using its own RNA as a template,thereby counteracting the shortening of telomeres caused by chromosome replication and cell division.Due to its overexpression in over 85%of malignant tumor cells,telomerase has emerged as a highly promising biomarker and a novel target for cancer therapy.In recent years,given the importance of precise quantification of telomerase activity in guiding medical diagnosis and treatment strategies,researchers have developed various high-performance telomerase detection techniques.Among these,electrochemical biosensing technique has cause much attention due to its high sensitivity,operational convenience,rapid response,and ease of miniaturization.This paper focused on the latest advances in electrochemical sensing technique for detection of telomerase activity,aiming to provide inspiration for designing novel telomerase activity detection strategies by elucidating three unique properties of telomerase primer extension products.
10.A Sensitive Lateral Flow Immunoassay for Detection of Interleukin-6 Using Carbon Dots-Mesoporous Silica Nanocomposite Fluorescent Probes
Yue-Qian YANG ; Peng-Yue WANG ; Jia-Qi REN ; Xiao PAN ; Feng-Hua TAN ; Yu-Jie MA ; Cong-Ying WEN ; Jing-Bin ZENG
Chinese Journal of Analytical Chemistry 2025;53(9):1467-1475
In this study,a sensitive lateral flow immunoassay(LFIA)platform based on carbon dots-mesoporous silica nanocomposite(CD-MSNs)fluorescent probes was constructed for high-performance detection of inflammatory marker interleukin-6(IL-6).Green fluorescent carbon dots(CDs)were prepared by hydrothermal method with 3,9-perylenic acid and 3-aminopropyltriethoxysilane(APTES)as raw materials,and highly fluorescent CD-MSNs composites were then constructed by encapsulating the prepared CDs in mesoporous silica nanoparticles(MSNs).Fluorescent probes were prepared by covalent coupling of CD-MSNs with IL-6 antibody.Fluorescent immunochromatographic test strips were constructed by spraying IL-6 capture antibody and goat anti-mouse IgG on nitrocellulose membrane as detection line(T-line)and quality control line(C-line),respectively.The fluorescence immunoassay analyzer was used to quantitatively detect the fluorescence intensity of T-line,and the experimental results showed that the LFIA platform based on this probe had a good linear relationship in IL-6 concentration range of 102-106 pg/mL,and the detection limit was 64 pg/mL,which was two orders of magnitude more sensitive than that of the traditional colloidal gold test strips.This method effectively solved the issue of insufficient sensitivity of traditional LFIA technique,and provided a rapid and highly sensitive detection method for early diagnosis of inflammatory diseases.

Result Analysis
Print
Save
E-mail