1.The first record of Anopheles messeae (Diptera: Culicidae) parasitized by water mites in China
Xue-ru CHEN ; Wen-zhen YAO ; Yu-hao LI ; Gui-chang LI ; Tao MENG ; Qun-ling FENG ; Xin-hui LIU ; Li-hong QIAO ; Xiang-ting WU ; Xue-feng ZHANG ; Cheng-lin LI ; Xue-cheng DONG ; Da-wei WANG ; Xiao-yan SI ; Yu-hong GUO
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):53-57
Objective This study reports on the obligatory parasitism of water mites Arrenurus sp. on Anopheles messeae at the Manzhouli Port, Inner Mongolia, China. Methods Duing July 2024, a survey on the mosquito diversity was conducted at the Manzhouli Port. Captured mosquitoes and their ectoparasites were identified to species level. Results A total of 1840 adult mosquitoes were collected, representing species from three genera: Culex(Cx. modestus, Cx. pipiens pallens), Aedes(Ae. dorsalis, Ae. flavidorsalis, Ae. flavescens), and Anopheles (An. messeae). Among all the mosqutioes specimens,3 out of 150 captured An. messeae were found to carry ectoparasitic mites, with number of 2,4,27 mites separately. Morphological and molecular identification reached the same result as water mites(Hydrachnidiae, Hydracrina). COI gene sequence showed 94% similarity with the closest species Arrenurus truncatellus. Conlusions Literature review suggests water mites are host-specific parasitism of mosquito species and herein with the first record of Arrenurus sp. parasiting on An. Messeae in the most high-latitude region globally.
2.Influence of atrial septal defect on mitral valve growth after repair of coarctation of the aorta or an interrupted aortic arch in infants
Yi-Chia WANG ; Heng-Wen CHOU ; Chi-Hsiang HUANG ; Hsing-Hao HUANG ; Yih-Sharng CHEN ; En-Ting WU ; Shyh-Jye CHEN ; Ming-Tai LIN ; Shuenn-Nan CHIU ; Shu-Chien HUANG
Clinical and Experimental Pediatrics 2026;69(4):322-329
Background:
Patients with coarctation of the aorta (CoA) and an interrupted aortic arch (IAA) may present with small mitral valves (MVs) and a reduced left ventricular (LV) volume. Biventricular repair (BVR) in these patients is dependent on adequate size of the left cardiac structures.Purpose: This study evaluated the impact of the hemodynamic characteristics of atrial septal defects (ASDs) on MV growth following surgical repair.
Methods:
We retrospectively reviewed the data of patients diagnosed with CoA or IAA between 2007 and 2024. The z score for MV size measured 6 months postoperatively (Z2) was compared with the preoperative MV size (Z1). The factors associated with MV growth were also studied.
Results:
A total of 161 patients with CoA or IAA were included. Transthoracic echocardiography was used to assess the MV and LV dimensions preoperatively and 6 months postoperatively. Of the cohort, 155 (96.3%) underwent initial BVR and 6 underwent single-ventricle palliation. MV z scores significantly increased following BVR (mean change: +0.45±1.35; P<0.001) but decreased after single-ventricle repair (-0.56±0.49, P=0.04). Multivariate analysis identified the initial MV z score and ASD pressure gradient as independent predictors of MV growth (R2=0.39).
Conclusion
Annular growth of the MV was not observed in patients who underwent single-ventricle palliation. In contrast, among patients who achieved BVR, those with a small preoperative MV annulus and low ASD pressure gradient demonstrated subsequent catch-up MV growth, suggesting that adequate left-sided preload is essential for MV development.
3.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
4.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
5.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
6.Current Status and Prospects of Artificial Intelligence Technologyin Minimally Invasive Gastric Cancer Surgery
Tao ZHANG ; Boer SU ; Guanxing LIANG ; Shiman DAI ; Jiawei CHEN ; Zhengjie LIU ; Cheng PENG ; Rong LIU ; Qinglan LIN ; Yidan WU ; Yuhui WU ; Jiaming WEN ; Hong WANG ; Hao CHEN ; Jiang YU
Medical Journal of Peking Union Medical College Hospital 2026;17(4):933-942
Gastric cancer remains a highly prevalent malignancy worldwide, with surgical resection currently constituting the cornerstone of treatment aimed at improving long-term patient survival. Owing to their notable advantages, including reduced surgical trauma and accelerated postoperative recovery, minimally invasive procedures are progressively supplanting conventional open surgery and have become the mainstream approach in gastric cancer management. Concurrently, the rapid advancement of artificial intelligence (AI) technologies has enabled real-time intraoperative monitoring of surgical scenes, thereby furnishing novel technical support for adjunctive decision-making, surgical navigation, and skill assessment during gastrectomy. This article provides a systematic review of the current status of AI applications in minimally invasive gastric cancer surgery, with a particular focus on research progress pertaining to instrument recognition, surgical phase identification, delineation of normal anatomical structures, detection of metastatic foci, and early warning of intraoperative adverse events. Furthermore, we discuss the potential value of AI in enhancing surgical efficiency, ensuring patient safety, and optimizing surgical education. On this basis, we further analyze the principal challenges and inherent risks confronting current AI systems, with the aim of informing future technological innovation and facilitating clinical translation.
7.Analysis on the Framework for Methodological Quality Assessment in Health Economic Evaluation Based on the Prag-matic Clinical Trial
Yu XIN ; Ruomeng SONG ; Jun HAO ; Ling ZUO ; Yuanyi CAI ; Chenggang JIN ; Huanzhang WU ; Wen HUI
Chinese Health Economics 2025;44(5):5-11
Objective:To construct a framework for evaluating the quality of health economic evaluation methodology based on the pragmatic clinical trial.Methods:An evaluation framework was constructed based on existing quality evaluation tools for health economic evaluation other quality evaluation tools.The weights of each item in the framework were determined by the Delphi method,and the weighted average was calculated using the expert authority coefficient.Results:A total of 23 experts were consulted,and the expert authority coefficients were 0.88 and 0.90,respectively.The results of the Wilcoxon signed-rank test showed no statistically signifi-cant differences among the expert opinions in two rounds(P>0.05).Finally,a framework with 3 dimensions and 8 items was estab-lished.Conclusion:The evaluation framework has high scientificity and reliability.
8.Intestinal flora of personnel stationed on an island based on 16S rRNA high-throughput sequencing
Hao WU ; Pei XIE ; Di ZHANG ; Wen HUANG ; Zhaoshen LI ; Qian XUE ; Jintao JU
Academic Journal of Naval Medical University 2025;46(3):400-405
Objective To analyze the characteristics of intestinal flora of personnel stationed on an island,so as to lay the foundation for maintaining the intestinal microecological balance of personnel stationed on island and provide accurate medical security.Methods Several subjects stationed on an island and several subjects from coastal areas were enrolled by random and sampling method,and their fecal samples were sequenced by 16S rRNA high-throughput sequencing.Diversity and composition of gut microbiota in 2 cohorts of personnel were compared.Results Alpha diversity analysis of intestinal flora showed that the abundance of intestinal flora in subjects stationed on the island was significantly higher than that of subjects from coastal areas.Beta diversity analysis indicated significant differences in the composition of intestinal microbial communities between the subjects stationed on the island and those from coastal areas(P=0.001).The abundance of the Bacteroidota in the intestinal tract of subjects stationed on the island was significantly lower than that of subjects from coastal areas(30.8%vs 48.3%,P<0.001),while the abundance of the Proteobacteria was significantly higher than that of subjects from coastal areas(28.3%vs 10.2%,P<0.001).After multiple hypothesis testing correction,it was found that the abundance of the Bacteroides,Roseburia,Alistipes,and Parabacteroides in the intestines of subjects stationed on the island decreased significantly,while the abundance of the Prevotella,Escherichia-Shigella,Citrobacter,and Eubacterium_coprostanoligenes increased significantly.Conclusion The special environment of islands affects the characteristics of intestinal flora of personnel,and the intestinal microecological health needs precise maintenance.
9.Application of a novel portable endoscope in upper gastrointestinal examinations in primary medical units:an analysis of 532 cases
Chao XU ; Wenbin ZOU ; Jiulong ZHAO ; Ting ZHANG ; Nian HUANG ; Hao WU ; Cui LIU ; Wen HUANG ; Zhaoshen LI ; Zhuan LIAO
Academic Journal of Naval Medical University 2025;46(6):810-816
Objective To explore the application value of a novel portable endoscope to perform upper gastrointestinal tract examinations in primary medical units.Methods A total of 532 subjects receiving portable endoscope examination were enrolled for analysis.The primary outcome was the success rate of operation.The secondary outcomes were the operation time,examination results,polyp removal and biopsy pathology results,and the subjective evaluation.Results In 532 cases,2 were withdrawn midway after the endoscope was inserted into the esophagus due to the patients'inability to tolerate the examination.Additionally,6 cases did not undergo examination of the descending part of the duodenum because of serious reactions during the procedure.Ultimately,524 cases successfully completed the upper gastrointestinal examination,and the success rate was 98.5%.The average examination time was(4.7±1.8)min,and the average time for disposal sheath wearing and removing was(4.2±1.4)min.The most common lesions were chronic non-atrophic gastritis(85.1%,451/530),reflux esophagitis(14.7%,78/530)and bile reflux(14.0%,74/530).A total of 10 cases of polyp removal were completed,and the polyp removal rate was 71.4%(10/14).Biopsy pathological diagnosis was completed in 44 cases,and the biopsy rate was 8.3%(44/530).The main discomfort symptoms during the examination were nausea(53.6%,285/532),vomiting(51.1%,272/532),and sore throat(38.5%,205/532),the main discomfort symptoms after the examination were sore throat(27.8%,148/532),nausea(19.5%,104/532),and vomiting(14.7%,78/532).No serious adverse events such as gastrointestinal bleeding,perforation,cardiac or pulmonary complications occurred.Conclusion The novel portable endoscope can safely and effectively complete the diagnosis and treatment of upper gastrointestinal diseases in primary medical units,while saving the decontamination process.However,the incidence of discomfort is high during examinations.Further optimization of the operation methods is needed.
10.Detection rate and related factors of gastrointestinal diseases in grass-roots personnel investigated by magnetic-controlled capsule endoscopy
Yidan ZHANG ; Tian XIA ; Jiayun CHEN ; Xi JIANG ; Hao WU ; Wen HUANG ; Zhaoshen LI ; Yangyang QIAN
Academic Journal of Naval Medical University 2025;46(7):931-937
Objective To investigate the detection rate and related influencing factors of gastrointestinal diseases in grass-roots personnel.Methods A total of 481 grass-roots personnel were enrolled and examined by magnetic-controlled capsule endoscopy(MCCE).Multivariate logistic regression were used to analyze the influencing factors of gastrointestinal diseases detected by MCCE.Results All personnel completed MCCE,and gastrointestinal diseases were detected in 154(32.0%)cases,including 106 cases of erosive gastritis,25 cases of chronic atrophic gastritis,17 cases of digestive tract polyp,16 cases of gastric ulcer,5 cases of reflux esophagitis,4 cases of cardia,1 case of duodenitis,and 1 case of enteritis.Gastrointestinal diseases was correlated with special operation posts,long-term tasks within recent 6 months,abdominal distension,belching,nausea and vomiting,diarrhea and other symptoms(all P<0.05).Multivariate logistic regression analysis showed that the risk factors of gastrointestinal diseases were working in special operation posts,performing long tasks within 6 months,belching,nausea and vomiting symptoms(all P<0.05).Conclusion The overall detection rate of gastrointestinal diseases(mainly acid related diseases)is relatively high,and its incidence is closely related to working in special operation posts and performing long-term tasks within recent 6 months.Personnel working in special operation posts should be more alert to gastrointestinal diseases.Gastrointestinal symptoms have reference value for the prediction of lesions,but more attention should be paid to the identification of functional gastrointestinal diseases with endoscopy.


Result Analysis
Print
Save
E-mail