1.Visualization analysis of studies on Oncomelania hupensis control from 2005 to 2024
Wen ZHU ; Huatang LUO ; Hao WANG ; Yuelin XIONG ; Cong LIU
Chinese Journal of Schistosomiasis Control 2026;38(1):84-91
Objective To analyze Chinese and English publications pertaining to Oncomelania hupensis control from 2005 to 2024, so as to decipher the research status and hotspots of O. hupensis control. Methods Chinese and English publications pertaining to O. hupensis control from 2005 to 2024 were retrieved in the Web of Science Core Collection Database and China National Knowledge Infrastructure. The annual number of publications was analyzed from 2005 to 2024, and the author and institution cooperation networks were mapped using the software CiteSpace 6.3.1. Keywords were extracted from publications to map the co-occurrence, burst and timeline of keywords to identify the research hotspots of O. hupensis control. Results A total of 158 English publications and 771 Chinese publications were included for bibliometric analyses. The overall output of English publications was relatively small from 2005 to 2024, the annual average publication was 7.90 publications. Parasites & Vectors was the most productive journal by the number of publications (21 publications). The three most productive authors included Li Shizhu (24 publications), Zhou Xiaonong (13 publications), and Yang Kun (12 publications), and the three most productive institutions included Chinese Center for Disease Control and Prevention (49 publications), the WHO (27 publications), and Fudan University (25 publications). The annual average number of Chinese publications was high from 2005 to 2015 (57.73 publications), and reduced to 15.11 publications during the period from 2016 to 2024, with Chinese Journal of Schistosomiasis Control as the most productive journal (241 publications). The three most productive authors included Wang Wanxian (18 publications), Sun Qixiang (16 publications), and Dai Jianrong (16 publications), and the three most productive institutions included Jiangsu Institute of Parasitic Diseases (55 publications), Chinese Center for Disease Control and Prevention (47 publications), and Hubei Uni-versity (38 publications). Among the 158 English publications, molluscicidal effect, climate change, geographic information, biological control, machine learning were current research hotspots, and the Yangtze River and elimination were emerging research hotspots. Among the 771 Chinese publications, molluscicidal effect, niclosamide, comprehensive management, molluscicide, effectiveness evaluation, marshland, and endophyte were current research hotspots, and the future research hotspots shifted to molluscicidal effect and pyriclobenzuron. Conclusions Limited attention is paid to the research on O. hupensis control across the world. The Yangtze River, elimination, molluscicidal effect, and pyriclobenzuron may be future research hotspots. High attention is recommended to be paid to the research on O. hupensis control, and development of diverse approaches for O. hupensis control is of urgent needs. We should continue to attach importance to the control research of O. hupensis and strengthen the exploration of diverse snail extermination and control methods.
2.Influence of atrial septal defect on mitral valve growth after repair of coarctation of the aorta or an interrupted aortic arch in infants
Yi-Chia WANG ; Heng-Wen CHOU ; Chi-Hsiang HUANG ; Hsing-Hao HUANG ; Yih-Sharng CHEN ; En-Ting WU ; Shyh-Jye CHEN ; Ming-Tai LIN ; Shuenn-Nan CHIU ; Shu-Chien HUANG
Clinical and Experimental Pediatrics 2026;69(4):322-329
Background:
Patients with coarctation of the aorta (CoA) and an interrupted aortic arch (IAA) may present with small mitral valves (MVs) and a reduced left ventricular (LV) volume. Biventricular repair (BVR) in these patients is dependent on adequate size of the left cardiac structures.Purpose: This study evaluated the impact of the hemodynamic characteristics of atrial septal defects (ASDs) on MV growth following surgical repair.
Methods:
We retrospectively reviewed the data of patients diagnosed with CoA or IAA between 2007 and 2024. The z score for MV size measured 6 months postoperatively (Z2) was compared with the preoperative MV size (Z1). The factors associated with MV growth were also studied.
Results:
A total of 161 patients with CoA or IAA were included. Transthoracic echocardiography was used to assess the MV and LV dimensions preoperatively and 6 months postoperatively. Of the cohort, 155 (96.3%) underwent initial BVR and 6 underwent single-ventricle palliation. MV z scores significantly increased following BVR (mean change: +0.45±1.35; P<0.001) but decreased after single-ventricle repair (-0.56±0.49, P=0.04). Multivariate analysis identified the initial MV z score and ASD pressure gradient as independent predictors of MV growth (R2=0.39).
Conclusion
Annular growth of the MV was not observed in patients who underwent single-ventricle palliation. In contrast, among patients who achieved BVR, those with a small preoperative MV annulus and low ASD pressure gradient demonstrated subsequent catch-up MV growth, suggesting that adequate left-sided preload is essential for MV development.
3.The first record of Anopheles messeae (Diptera: Culicidae) parasitized by water mites in China
Xue-ru CHEN ; Wen-zhen YAO ; Yu-hao LI ; Gui-chang LI ; Tao MENG ; Qun-ling FENG ; Xin-hui LIU ; Li-hong QIAO ; Xiang-ting WU ; Xue-feng ZHANG ; Cheng-lin LI ; Xue-cheng DONG ; Da-wei WANG ; Xiao-yan SI ; Yu-hong GUO
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):53-57
Objective This study reports on the obligatory parasitism of water mites Arrenurus sp. on Anopheles messeae at the Manzhouli Port, Inner Mongolia, China. Methods Duing July 2024, a survey on the mosquito diversity was conducted at the Manzhouli Port. Captured mosquitoes and their ectoparasites were identified to species level. Results A total of 1840 adult mosquitoes were collected, representing species from three genera: Culex(Cx. modestus, Cx. pipiens pallens), Aedes(Ae. dorsalis, Ae. flavidorsalis, Ae. flavescens), and Anopheles (An. messeae). Among all the mosqutioes specimens,3 out of 150 captured An. messeae were found to carry ectoparasitic mites, with number of 2,4,27 mites separately. Morphological and molecular identification reached the same result as water mites(Hydrachnidiae, Hydracrina). COI gene sequence showed 94% similarity with the closest species Arrenurus truncatellus. Conlusions Literature review suggests water mites are host-specific parasitism of mosquito species and herein with the first record of Arrenurus sp. parasiting on An. Messeae in the most high-latitude region globally.
4.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
5.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
6.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
7.Analysis of the process framework and optimization strategies for the transformation of scientific and technological achievements in public hospitals based on Grounded Theory
Zi-wen XU ; Jia-jie ZHAO ; Dan-na ZHAO ; San-yuan HAO ; Zi-wei WANG ; Gu-yang FU ; Ren CHEN
Chinese Journal of Health Policy 2025;18(5):74-80
Objective:To understand the workflow and key tasks of the transformation of scientific and technological achievements in public hospitals,and propose optimization strategies from the perspective of managers.Methods:Based on the research method of Grounded Theory,semi-structured interviews were conducted among 23 managers of scientific and technological achievements transformation in public hospitals,and relevant concepts and categories were summarized by three stages coding with NVivo 12.Results:Through the three stages of coding,64 initial concepts,19 categories and 4 main categories were sorted out,and a framework diagram of the process of transforming scientific and technological achievements in public hospitals covering four stages was constructed.Conclusion:The scientific and technological achievements of public hospitals can be divided into four phases:project initiation and demand docking,research and development process and achievements incubation,achievements transformation and market docking,product promotion and industrial development,which can be used to achieve high-quality development of scientific and technological achievements through standardized management of the whole process,excavation of high-quality results,enhancement of humanistic construction,accumulation of scientific research experience,and standardization of qualification of technological managers.
8.Inhibition of excessive inflammatory response of macrophages by Ebselen against acute Escherichia coli infection
Xiao-wen LIU ; Xiao-qin MOU ; Chuang CHENG ; Shuang-shuang GONG ; Hao-ran ZHANG ; Jing HE ; Xi ZHENG ; Jun WANG ; Yue-qing WANG ; Li-li ZOU
Chinese Pharmacological Bulletin 2025;41(7):1346-1353
Aim To investigate the pharmacological mechanism of Ebselenin(Ebselen,EbSe)in the treat-ment of Escherichia coli(E.coli)infection,which had no significant inhibitory effect on Gram-negative bacte-ria,based on previous studies.Methods After EbSe intervention in E.coli infected Raw264.7 cells,the via-bility of Raw264.7 cells was determined by CCK-8 method,the morphology and structure of Raw264.7 cells were observed by electron microscope,and the in-tracellular bacterial load of Raw264.7 cells was calcu-lated by coated plate method.Polarization status of peritoneal macrophages,Raw264.7 intracellular NO and ROS content and intracellular HO-1 expression in Raw264.7 and E.coli acutely infected mice after E.co-li infection by flow cytometry.qPCR was used to detect the expression of related mRNAs in Raw264.7 cells.qPCR was used to detect the intracellular GSH content in Raw264.7 cells by spectrophotometric assay,and the state of cytoskeletal proteins was observed by immuno-fluorescence.Western blot assay was performed to de-tect the intracellular Txnrd1 expression level.Results Microtiter method,CCK-8,and electron microscopy observations showed that EbSe had no effect on the growth of E.coli and Raw264.7 cells in vitro.The re-sults of smear plate counting showed that EbSe reduced the intracellular bacterial load of Raw264.7 in the in-fected group.Flow cytometry results showed that EbSe upregulated the number of M2-type macrophages.The EbSe-treated infected group had reduced intracellular NO and ROS levels and increased GSH levels.The qPCR results showed that the expression of IL-6,IL-1β,and iNOS was decreased,and the expression of HO-1,Txnrd1,and Glut1 was increased in DHB4-in-fected Raw264.7 cells after EbSe treatment.Cytoskel-etal staining showed that the morphology of the EbSe-treated infected cells was similar to that of oxPAPC-in-duced cells.Western blot results showed the expres-sion of Txnrd1 protein in EbSe-treated infected cells in-creased.Conclusion EbSe exerts anti-E.coli acute infection effect by regulating macrophage polarization and inhibiting macrophage excessive inflammatory state.
9.Inhibition of excessive inflammatory response of macrophages by Ebselen against acute Escherichia coli infection
Xiao-wen LIU ; Xiao-qin MOU ; Chuang CHENG ; Shuang-shuang GONG ; Hao-ran ZHANG ; Jing HE ; Xi ZHENG ; Jun WANG ; Yue-qing WANG ; Li-li ZOU
Chinese Pharmacological Bulletin 2025;41(7):1346-1353
Aim To investigate the pharmacological mechanism of Ebselenin(Ebselen,EbSe)in the treat-ment of Escherichia coli(E.coli)infection,which had no significant inhibitory effect on Gram-negative bacte-ria,based on previous studies.Methods After EbSe intervention in E.coli infected Raw264.7 cells,the via-bility of Raw264.7 cells was determined by CCK-8 method,the morphology and structure of Raw264.7 cells were observed by electron microscope,and the in-tracellular bacterial load of Raw264.7 cells was calcu-lated by coated plate method.Polarization status of peritoneal macrophages,Raw264.7 intracellular NO and ROS content and intracellular HO-1 expression in Raw264.7 and E.coli acutely infected mice after E.co-li infection by flow cytometry.qPCR was used to detect the expression of related mRNAs in Raw264.7 cells.qPCR was used to detect the intracellular GSH content in Raw264.7 cells by spectrophotometric assay,and the state of cytoskeletal proteins was observed by immuno-fluorescence.Western blot assay was performed to de-tect the intracellular Txnrd1 expression level.Results Microtiter method,CCK-8,and electron microscopy observations showed that EbSe had no effect on the growth of E.coli and Raw264.7 cells in vitro.The re-sults of smear plate counting showed that EbSe reduced the intracellular bacterial load of Raw264.7 in the in-fected group.Flow cytometry results showed that EbSe upregulated the number of M2-type macrophages.The EbSe-treated infected group had reduced intracellular NO and ROS levels and increased GSH levels.The qPCR results showed that the expression of IL-6,IL-1β,and iNOS was decreased,and the expression of HO-1,Txnrd1,and Glut1 was increased in DHB4-in-fected Raw264.7 cells after EbSe treatment.Cytoskel-etal staining showed that the morphology of the EbSe-treated infected cells was similar to that of oxPAPC-in-duced cells.Western blot results showed the expres-sion of Txnrd1 protein in EbSe-treated infected cells in-creased.Conclusion EbSe exerts anti-E.coli acute infection effect by regulating macrophage polarization and inhibiting macrophage excessive inflammatory state.
10.Establishment and preliminary testing of a double antibody sandwich ELISA method for Brucella detection
Meng-xin YAO ; Ze-yu PENG ; Wen-hao REN ; Yi-mei XU ; Wei GUO ; Chuang-fu CHEN ; Zhong-chen MA ; Yong WANG
Chinese Journal of Zoonoses 2025;41(3):255-262
This study was aimed at establishing a sensitive and specific sandwich ELISA detection method for Brucella.We screened monoclonal capture antibodies and detection antibodies for Brucella detection,and optimized and determined the opti-mal antibody coating time and concentration,as well as the optimal blocking solution,blocking time,and yin-yang critical val-ue.The specificity of this method was verified by examination of other bacteria prone to cross-reacting with Brucella.The sen-sitivity of the method was verified by detection of a gradient dilution of inactivated Brucella.Moreover,the sandwich ELISA detection results were compared with test tube agglutination and qPCR results.The selected capture antibody was 4A12,and the selected detection antibody was 6C12.Experimental analysis indicated that the optimal coating concentration for the 4A12 capture antibody was 5 μg/mL,and the optimal dilution ratio for the 6C12 detection antibody was 1∶2000.The optimal coating conditions were overnight at 4℃,and blocking with 5%skim milk powder for 2 hours.The established double antibody sand-wich ELISA method reacted with only Brucella but not other bacteria,thus demonstrating the method's good specificity.Inac-tivated Brucella solution was still detectable after dilution to 1 × 105 CFU/mL,thus demonstrating the method's good sensitiv-ity.The intra-and inter batch coefficients of variation were both below 10%,thus indicating the method's good repeatability.Thus,this study successfully established a dual antibody sandwich ELISA method for Brucella detection,which has good spe-cificity and sensitivity,and might provide an effective approach for the precise diagnosis and effective prevention and control of brucellosis.


Result Analysis
Print
Save
E-mail