1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Validity and Cost-Consequence Analysis of the Brief Version of the Montreal Cognitive Assessment for Discriminating Cognitive Impairment in a Community-Based Middle-Aged and Elderly Population.
Ting PANG ; Ya-Ping ZHANG ; Ren-Wei CHEN ; Ai-Ju MA ; Xiao-Yi YU ; Yi-Wen HUANG ; Yi-Chun LU ; Xin XU
Acta Academiae Medicinae Sinicae 2025;47(3):382-389
Objective To evaluate the reliability and validity and perform cost-consequence analysis of the brief version of the Montreal cognitive assessment(MoCA)for identifying cognitive impairment in a community-based population ≥50 years of age.Methods The internal consistency and retest reliability of the brief version of the MoCA were analyzed,and the area under the curve(AUC),sensitivity,and specificity were determined to discriminate mild cognitive impairment(MCI)and dementia with the clinical dementia rating(CDR)as the diagnostic criterion.The consistency between the brief version and the full version was analyzed by the Kappa test and the Bland-Altman method,and the number of individuals entering the diagnostic assessment and the overall assessment time were estimated and compared between the two versions.Results A total of 303 individuals were included in this study,of whom 192,94,and 17 had normal cognitive function,MCI,and dementia,respectively.The Cronbach's α and re-test coefficients of the brief version of MoCA were 0.754 and 0.711(P<0.001),respectively.The brief version showed the AUC,sensitivity,and specificity of 0.889,74.5%,and 93.8% for identifying MCI,and 0.994,100%,and 93.8% for identifying dementia,respectively.When the brief version of MoCA was used to identify 94 patients with MCI in 303 individuals,107 individuals required additional diagnostic assessment,with an overall assessment time of 142.4 h,which represented decreases of 21.3% and 32.7%,respectively,compared with those of the full version.When the brief version of MoCA was used to identify 17 patients with dementia in 303 individuals,35 individuals required additional diagnostic assessment,with an overall assessment time of 70.4 h,a decrease of 29.5% in the time cost compared with the full version.Conclusions The brief version of MoCA can identify cognitively impaired individuals in a community-based middle-aged and elderly population,with diagnostic validity comparable to that of the full version but less time cost and fewer individuals needing additional diagnostic assessment to detect true-positive cases.It could be expanded for use in the community-based primary screening setting.
Humans
;
Aged
;
Middle Aged
;
Cognitive Dysfunction/diagnosis*
;
Male
;
Female
;
Mental Status and Dementia Tests
;
Reproducibility of Results
;
Dementia/diagnosis*
;
Sensitivity and Specificity
;
Aged, 80 and over
;
Cost-Benefit Analysis
3.Erratum: Author Correction: Targeting of AUF1 to vascular endothelial cells as a novel anti-aging therapy.
Jian HE ; Ya-Feng JIANG ; Liu LIANG ; Du-Jin WANG ; Wen-Xin WEI ; Pan-Pan JI ; Yao-Chan HUANG ; Hui SONG ; Xiao-Ling LU ; Yong-Xiang ZHAO
Journal of Geriatric Cardiology 2025;22(9):834-834
[This corrects the article DOI: 10.11909/j.issn.1671-5411.2017.08.005.].
4.Highly Sensitive Detection of Water in Organic Solvents Using Pyrene-Phenol-based Fluorescent Probe
Jing LIANG ; Yan-Li WANG ; Cui-Wen JIANG ; Xiao-Chuan HUANG ; Li TANG ; Tao LI ; Yu YA ; De-Jiao NING ; Li-Ping XIE ; Fei-Yan YAN
Chinese Journal of Analytical Chemistry 2025;53(6):894-902,中插1-中插5
A pyrene-phenol-based fluorescent probe PyP which showed typical intramolecular charge transfer(ICT)and monomer-excimer activities was synthesized by using pyrene carboxaldehyde hydrazone and 4-tert-butyl-2,6-diformylphenol as the raw materials.The effects of solvents on PyP were studied,and the results showed that the color of protic polar solvents(Ethanol,N,N-dimethylformamide,methanol and H2O)were successfully identified.Based on the solvent polarity-regulated PyP monomer-excimer switching,the rapid and highly sensitive ratiometric probe,"Turn-off"and"Turn-on"multimodal probes were established for detection of trace water content in organic solvents(Dimethyl sulfoxide,N,N-dimethylformamide,ethanol and methanol),with detection limits(3σ/k)of 0.0021%,0.046%,0.062%and 0.024%.The method was successfully used to detect water content in dimethyl sulfoxide,N,N-dimethy lformamide,ethanol and methanol commercial organic solvents,with recoveries ranging from 97.2%to 108.0%.The developed method showed good accuracy and stability,and had good application prospect.
5.The efficacy of combining mirror therapy with pneumatic flexible glove training in treating post-stroke hand dysfunction
Cuifeng WEN ; Hao HUANG ; Ru YA ; Yulong BAI ; Xiaowen WANG ; Haoming SONG
Chinese Journal of Physical Medicine and Rehabilitation 2025;47(10):914-921
Objective:To observe the effectiveness of combining mirror therapy with pneumatic flexible glove training in treating hand dysfunction after a stroke. Its effect on cerebral cortex activation was documented using near-infrared functional imaging of the brain.Methods:A total of 84 stroke survivors with hand dysfunction were randomly divided into a Mirror Group, a Glove Group and a Combined Group, each of 28. In addition to standard rehabilitation training, the Glove Group received 20 minutes of training with a pneumatic soft glove, 5 days per week for 6 consecutive weeks. The Mirror Group received mirror therapy (MT). The Combined Group was given both simultaneously. Before and after the treatment, everyone′s upper limb functioning was evaluated (using the Fugl-Meyer Upper Limb Assessment (FMA-U)), along with their hand motor skills (using the Arm Action Test (ARAT)) and their ability in daily living activities (using the Barthel Index (BI)). Functional near-infrared spectroscopy (fNIRS) was employed to measure any changes in oxygenated hemoglobin (HBO) concentration at 730nm and 850nm wavelengths.Results:The FMA-U, ATAT and BI scores in both the proximal and distal regions of all three groups showed significant improvement after the treatments compared to pre-treatment levels. The combined group demonstrated significantly better distal FMA-U and ARAT scores after the treatment (12.25±8.80 and 20.93±15.68 respectively), outperforming both the glove and mirror groups. The infrared spectroscopy revealed that bilateral SM1 activation, affected-side somatosensory association cortex (SAC) and supplementary motor cortex excitability in both the mirror and combined groups were significantly better than among the glove group after the experiment.Conclusions:Combined with pneumatic flexible glove training, mirror therapy can not only significantly improve the hand function of stroke survivors, but also activate the relevant brain regions of both hemispheres through bilateral motor patterns combined with multisensory stimulation, promoting the balance between hemispheres.
6.CURRENT DISTRIBUTION OF AEDES AEGYPTI IN LEIZHOU PENINSULA,ZHANJIANG CITY,GUANGDONG PROVINCE
Rui-Peng LU ; Jin-Hua DUAN ; Yu-Wen ZHONG ; Hui DENG ; Jun WU ; Li-Ping LIU ; Wei-Xiong YIN ; Feng XING ; Hui HUANG ; Chang-Jie FU ; Zong-Jing CHEN ; Ming-Ji CHENG ; Sheng-Jun HU ; Ya-Ting CHEN ; Wen-Ting GUO ; Li-Feng LIN
Acta Parasitologica et Medica Entomologica Sinica 2025;32(1):16-21
Objective To investigate the status of population dynamics and distribution changes of Aedes aegypti in Guangdong Province.Methods Continuous monitoring was conducted from May 2018 to July 2024 in Wushi Town and Qishui Town,Leizhou City,Zhanjiang City,Guangdong Province.Additionally,a survey of the distribution of Ae.aegypti along the Leizhou Peninsula coast was carried out.Results The density of Ae.aegypti in Zhanjiang showed a gradual decline from 2018 to 2024.The last detection of adult Ae.aegypti in Wushi Town was in September 2021,and the last larva was found in October 2023.No Ae.aegypti was detected in Qishui Town during surveys from 2021 to 2024.A survey of 18 coastal villages in the Leizhou Peninsula revealed no detections of Ae.aegypti.Conclusions This study provides a basis for understanding the distribution and population density fluctuations of Ae.aegypti,assessing its invasion risk,and scientifically conducting relevant prevention and control efforts.
7.Mechanism of dioscin inhibiting apoptosis in HT22 cells after OGD/R
Zi-xin CHEN ; Zhi-hui CHEN ; Wen-chuan LUO ; Feng-lin RAO ; Mei HUANG ; Ya-ping CHEN ; Li-hong NAN
Chinese Pharmacological Bulletin 2025;41(2):277-283
Aim To investigate the neuroprotective effect of dioscin(DIO)on hippocampal neurons(HT22)after oxygen glucose deprivation/reoxygen-ation(OGD/R)and its possible mechanism.Methods HT22 cells were treated with 0,2.5,5,10,20,40,80,160,and 320 mg·L-1DIO for 24 h,and the cell proliferation rate was detected by CCK-8 method.The concentration that was non-toxic to HT 2 2 cells was se-lected for subsequent experiments.After OGD for 2 h,HT22 cells were randomly divided into the OGD/R group,1.25,2.5,and 5 mg·L-1DIO group,and posi-tive control group.HT22 cells were taken as the con-trol group.After drug intervention for 24 h,the cell proliferation rate was detected by CCK-8 method;the LDH release was detected by colorimetry;the cell ap-optosis rate was detected by TUNEL method;the ex-pression of proteins related to PARP-1/AIF pathway and caspase pathway was detected by Western blot.Results DIO intervention significantly upregulated the expression of AIF protein in mitochondria and PAR protein in nucleus of HT22 cells after OGD/R,and sig-nificantly downregulated the release of LDH,neuronal apoptosis rate,total protein expression of AIF and PAR,PARP-1,AIF in nucleus and protein expression of PAR protein in mitochondria,while the expression of Bax and caspase-3 proteins was not significantly differ-ent from that in the OGD/R group.Conclusion DIO can alleviate the apoptosis of HT22 cells induced by OGD/R by regulating the expression and translocation of proteins related to the PARP-1/AIF pathway,thus playing a neuroprotective role.
8.Cross-sectional survey of healthcare-associated infection in 5 736 medical institutions across China in 2024
Cui ZENG ; Wuqiang GAO ; Fu QIAO ; Hui ZHAO ; Xu FANG ; Linping LI ; Xiuwen CHEN ; Jiansen CHEN ; Dan LI ; Yuan ZHOU ; Lingli YU ; Qinglan MENG ; Xia MOU ; Lijuan XIONG ; Weiguang LI ; Ding LIU ; Jiaqing XIAO ; Limei OU ; Baozhen LI ; Jun YIN ; Haojun ZHANG ; Qiang FU ; Qun LU ; Biao WU ; Ya-wei XING ; Shumei SUN ; Shuncai WANG ; Longmin DU ; Jingping ZHANG ; Wen-ying HE ; Gui CHENG ; Nan REN ; Xun HUANG ; Anhua WU
Chinese Journal of Infection Control 2025;24(11):1572-1583
Objective To understand the current situation of healthcare-associated infection(HAI)in China,pro-vide data support and decision-making basis for formulating scientific and effective strategies for HAI prevention and control.Methods A nationwide cross-sectional survey on HAI was conducted among various types and levels of medical institutions in China according to a unified protocol of bedside surveys and case investigations.Results In 2024,a total of 5 736 medical institutions and 2 751 765 patients were surveyed.Among them,34 889 HAI cases were identified,with a prevalence rate of 1.27%.The number of HAI episodes was 38 032,and case prevalence rate was 1.38%.The prevalence rate of HAI in medical institutions in different regions of China ranged from 0.66%to 2.35%.Among medical institutions of different scales,those with a bed capacity of ≥900 had the high-est incidence of HAI,reaching 1.65%.The most common infection site was the lower respiratory tract(44.66%),followed by the urinary tract(12.94%),surgical site(9.32%),upper respiratory tract(7.02%),and bloodstream infection(5.78%).The top 3 departments with the highest HAI rates were the general intensive care unit(10.02%),department of neurosurgery(5.51%),and department(group)of hematology(5.34%).A total of 23 238 strains of HAI pathogens were detected,with 10 714 strains(46.10%)from lower respiratory tract speci-mens.The top 5 detected strains were Klebsiella pneumoniae(14.76%),Pseudomonas aeruginosa(13.33%),Escherichia coli(12.79%),Acinetobacter baumannii(9.23%),and Staphylococcus aureus(7.88%).231 944 pa-tients underwent class Ⅰ incision surgery were monitored,with 1 647 cases experienced surgical site infection,and the prevalence rate of surgical site infection was 0.71%.The number of patients who should undergo pathogen de-tection(patients receiving therapeutic and therapeutic combined prophylactic antimicrobial agents)was 715 179,while the actual number was 480 492,with a pathogen detection rate of 67.18%.425 225 patients received patho-genic detection before treatment,with a detection rate of 59.46%.Conclusion The overall HAI prevalence in Chi-na is lower,showing disparities among medical institutions of different regions and scales.Therefore,precise imple-mentation of measures is necessary for HAI prevention and control,with a focus on high-risk institutions and high-risk departments,key areas,and critical procedures.All levels of medical institutions should continuously reduce the incidence of HAI by strengthening monitoring,standardizing the use of antimicrobial agents,and reinforcing basic HAI prevention and control measures.
9.Development of transparent manikin and its application to surgical training on medical train
Ya-jun SONG ; Wen-gang HU ; Ming-hui YANG ; Sheng-qing LYU ; Chi-bing HUANG ; Ji-feng ZOU ; Yang LI ; Yun WANG ; Ji ZHENG
Chinese Medical Equipment Journal 2025;46(6):111-115
Objective To develop a novel type of transparent simulation manikin as a surgical training model to meet the surgical treatment demand on the medical train.Methods A transparent manikin was developed with the steps of basic data collection,motherboard design and manufacture and module production and assembly.Firstly,basic data collection was carried out with reference to standardized human anatomy and parameters.Secondly,some software such as UG NX7.5 was used to construct the motherboard of the manikin.Finally,module production and assembly were performed with the materials of acrylic,transparent rubber,silicone and hydrogel and the technology of silicone infusion.Results The transparent manikin developed had its anatomy structure close to that of the real body and high visuality for its internal and external components,which simulated a variety of war wounds and thus could be integrated with the surgical training scenarios on the medical train effectively.Conclusion The transparent manikin developed is characterized by high visuality,modularity and blood flow,and meets the demands for surgical training on the medical train.[Chinese Medical Equipment Journal,2025,46(6):111-115]
10.Regulatory mechanisms and therapeutic strategies of microcirculation after spinal cord injury
Jing HUANG ; Ya-Feng REN ; Wen-Ya SHANG ; Zhi-Lan ZHANG ; Xiao-Meng HUANG ; Bing LI
Medical Journal of Chinese People's Liberation Army 2025;50(3):358-365
Spinal cord injury(SCI)is a structural and functional disruption of the spinal cord caused by various factors,leading to neurological dysfunction.As a common central nervous system disorder in clinical practice,SCI poses significant risks to human life and health.Its pathological mechanism is exceedingly complex,involving multiple pathological processes.Given the irreversibility of primary injury,targeting secondary injury has gradually become the main direction for the clinical treatment of SCI in recent years.Recent studies have highlighted the crucial role of blood-spinal cord barrier damage and microvascular dysfunction in the progression of secondary injury following SCI.Therefore,investigating the pathological mechanisms of microcirculation and exploring targeted therapies could provide valuable insights for clinical SCI treatment.This paper aims to provide an objective review of the role of microcirculation in SCI,identify the critical regulators of microvascular function,and summarize strategies for treating SCI by targeting microcirculation.The findings of this study may offer novel references for the clinical management of SCI.

Result Analysis
Print
Save
E-mail