1.Influence of atrial septal defect on mitral valve growth after repair of coarctation of the aorta or an interrupted aortic arch in infants
Yi-Chia WANG ; Heng-Wen CHOU ; Chi-Hsiang HUANG ; Hsing-Hao HUANG ; Yih-Sharng CHEN ; En-Ting WU ; Shyh-Jye CHEN ; Ming-Tai LIN ; Shuenn-Nan CHIU ; Shu-Chien HUANG
Clinical and Experimental Pediatrics 2026;69(4):322-329
Background:
Patients with coarctation of the aorta (CoA) and an interrupted aortic arch (IAA) may present with small mitral valves (MVs) and a reduced left ventricular (LV) volume. Biventricular repair (BVR) in these patients is dependent on adequate size of the left cardiac structures.Purpose: This study evaluated the impact of the hemodynamic characteristics of atrial septal defects (ASDs) on MV growth following surgical repair.
Methods:
We retrospectively reviewed the data of patients diagnosed with CoA or IAA between 2007 and 2024. The z score for MV size measured 6 months postoperatively (Z2) was compared with the preoperative MV size (Z1). The factors associated with MV growth were also studied.
Results:
A total of 161 patients with CoA or IAA were included. Transthoracic echocardiography was used to assess the MV and LV dimensions preoperatively and 6 months postoperatively. Of the cohort, 155 (96.3%) underwent initial BVR and 6 underwent single-ventricle palliation. MV z scores significantly increased following BVR (mean change: +0.45±1.35; P<0.001) but decreased after single-ventricle repair (-0.56±0.49, P=0.04). Multivariate analysis identified the initial MV z score and ASD pressure gradient as independent predictors of MV growth (R2=0.39).
Conclusion
Annular growth of the MV was not observed in patients who underwent single-ventricle palliation. In contrast, among patients who achieved BVR, those with a small preoperative MV annulus and low ASD pressure gradient demonstrated subsequent catch-up MV growth, suggesting that adequate left-sided preload is essential for MV development.
2.The first record of Anopheles messeae (Diptera: Culicidae) parasitized by water mites in China
Xue-ru CHEN ; Wen-zhen YAO ; Yu-hao LI ; Gui-chang LI ; Tao MENG ; Qun-ling FENG ; Xin-hui LIU ; Li-hong QIAO ; Xiang-ting WU ; Xue-feng ZHANG ; Cheng-lin LI ; Xue-cheng DONG ; Da-wei WANG ; Xiao-yan SI ; Yu-hong GUO
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):53-57
Objective This study reports on the obligatory parasitism of water mites Arrenurus sp. on Anopheles messeae at the Manzhouli Port, Inner Mongolia, China. Methods Duing July 2024, a survey on the mosquito diversity was conducted at the Manzhouli Port. Captured mosquitoes and their ectoparasites were identified to species level. Results A total of 1840 adult mosquitoes were collected, representing species from three genera: Culex(Cx. modestus, Cx. pipiens pallens), Aedes(Ae. dorsalis, Ae. flavidorsalis, Ae. flavescens), and Anopheles (An. messeae). Among all the mosqutioes specimens,3 out of 150 captured An. messeae were found to carry ectoparasitic mites, with number of 2,4,27 mites separately. Morphological and molecular identification reached the same result as water mites(Hydrachnidiae, Hydracrina). COI gene sequence showed 94% similarity with the closest species Arrenurus truncatellus. Conlusions Literature review suggests water mites are host-specific parasitism of mosquito species and herein with the first record of Arrenurus sp. parasiting on An. Messeae in the most high-latitude region globally.
3.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
4.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
5.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
6.Chemical constituents from the stems and leaves of Dendrobium formosum and their biological activities
Li-hang CHI ; Hui-qin CHEN ; Sheng-zhuo HUANG ; Fei WU ; Wen-li MEI ; Xi-qiang SONG ; Hao-fu DAI
Chinese Traditional Patent Medicine 2025;47(2):467-473
AIM To study the chemical constituents from the stems and leaves of Dendrobium formosum Roxb.ex Lindl.and their biological activities.METHODS The 95%ethanol extract from the stems and leaves of D.formosum was isolated and purified by silica gel,Sephadex LH-20 and semi-preparative HPLC,then the structures of obtained compounds were identified by physicochemical properties and spectral data.Their inhibitory activities onα-glucosidase were determined by PNPG method,and their in vitro anti-inflammatory activities were evaluated by RAW264.7 model.RESULTS Fifteen compounds were isolated and identified as coniferyl p-coumarate(1),(-)-pinoresinol(2),2,5,7-trihydroxy-4-methoxy-9,10-dihydrophenanthrene(3),naringenin(4),spiropreussomerin A(5),7-hydroxy-14-de-O-methyl-lasiodiplodin(6),(4S,5S,6Z,8E)-5-hydroxydeca-6,8-dien-4-olide(7),(6S,9R)-blumenol C(8),p-hydroxybenzoic acid(9),m-hydroxybenzoic acid(10),p-hydroxy benzenepropanoic acid(11),5,7-dihydroxy-isobenzofuran(12),2-(4-hydroxyphenyl)-ethanol(13),β-sitostenone(14),β-sitosterol(15).The IC50 values of compounds 1 and 4 on α-glucosidase inhibition were(65.60±3.31)and(98.95±2.53)μmol/L,respectively.Compound 3 presented inhibitory activity on NO production in RAW 264.7 cells,with IC50 value of(3.97±0.12)μmol/L.CONCLUSION Compounds 5-6,8 and 12 are isolated from Orchidacae family for the first time,and 2-15 are first isolated from this plant.Compounds 1 and 4 have α-glucosidase inhibitory activities,and 3 has anti-inflammatory activity.
7.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
8.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
9.Construction of CD8+T cell-associated Risk Model in Hepatocellular Carcinoma Based on Bulk and Single-cell RNA-seq Data
Xin-Tong ZHANG ; Jian-Jun ZHU ; Jin WU ; Hao WU ; Fan LU ; Wen-Tao ZHANG ; Jing-Jia CHANG ; Ting TANG ; Zhi-Gao OU ; Feng-Feng JIA ; Li LI ; Peng-Fei YU ; Ming LIU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(10):1511-1528
Hepatocellular carcinoma(HCC),which is essentially primary liver cancer,is closely related to CD8+T cell immune infiltration and immune suppression.We constructed a CD8+T cells related risk score model to pre-dict the prognosis of HCC patients and provided therapeutic guidance based on the risk score.Using integrated bulk RNA sequencing(RNA-seq)and single-cell RNA sequencing(scRNA-seq)datasets,we identified stable CD8+T cell signatures.Based on these signatures,a 3-gene risk score model,comprised of KLRB1,RGS2,and TN-FRSF1B was constructed.The risk score model was well validated through an independent external validation co-hort.We divided patients into high-risk and low-risk groups according to the risk score and compared the differ-ences in immune microenvironment between these two groups.Compared with low-risk patients,high-risk patients have higher M2-type macrophage content(P<0.0001)and lower CD8+T cells infiltration(P<0.0001).High-risk patients predict worse response to immunotherapy treatment than low-risk patients(P<0.01).Drug sensitivity a-nalysis shows that PI3K-β inhibitor AZD6482 and TGFβRII inhibitor SB505124 may be suitable therapies for high-risk patients,while the IGF-1R inhibitor BMS-754807 or the novel pyrimidine-based anti-tumor metabolic drug Gemcitabine could be potential therapeutic choices for low-risk patients.Moreover,expression of these 3-gene mod-el was verified by immunohistochemistry.In summary,the establishment and validation of a CD8+T cell-derived risk model can more accurately predict the prognosis of HCC patients and guide the construction of personalized treatment plans.
10.Role and mechanism of trpc6 in mice with ka-induced epileptogenesis
Si-min CHENG ; Hao-chuan WANG ; Yu-yan ZHANG ; Yu WANG ; Wen-ning WU
Chinese Pharmacological Bulletin 2025;41(11):2120-2127
Aim To investigate the role and underlying mechanisms of transient receptor potential cation chan-nel 6(TRPC6)in epileptogenesis using a kainic acid(KA)-induced mouse model.Methods C57BL/6 and TRPC6-KO(KO)mice were divided into two groups and implanted with cannulas for microinjection of KA(0.03 g·L-1,5 μL)into the lateral ventricle to establish the acute epilepsy model group,with saline injection serving as the control group.The Racine score was used to record the uninterrupted seizure grade of mice within two hours after KA administration.Immunohistochemistry was used to detect neuronal loss and tissue damage in the hippocampus brain region of mice.Immunofluorescence staining,Western blot and qPCR were used to detect the expressions of TRPC6,NLRP3,ASC,Caspase-1,p62,Atg7,Atg5,Beclin-1,LC3b-Ⅱ/LC3b-Ⅰ.in the hippocampus.Results KA induced significant neuronal loss and tissue damage in the hippocampal CA3 brain region of epilep-sy mice,while the expression levels of TRPC6,NL-RP3,ASC and Caspase-1 and other proteins in the hippocampus brain area of epilepsy mice increased,and the protein expression of autophagy-related proteins Atg7,Atg5,Beclin-1,LC3b-Ⅱ/LC3b-Ⅰ increased,while the expression of p62 protein decreased.TRPC6 knockout exacerbated KA-induced epileptogenesis,neuronal injury,inflammatory response and autophagy activation.Conclusion TRPC6 is involved in KA-in-duced epileptigenesis,and the mechanism may be re-lated to the activation of NLRP3 inflammasome-autoph-agy signaling caused by TRPC6 deletion.


Result Analysis
Print
Save
E-mail