1.Visualization analysis of studies on Oncomelania hupensis control from 2005 to 2024
Wen ZHU ; Huatang LUO ; Hao WANG ; Yuelin XIONG ; Cong LIU
Chinese Journal of Schistosomiasis Control 2026;38(1):84-91
Objective To analyze Chinese and English publications pertaining to Oncomelania hupensis control from 2005 to 2024, so as to decipher the research status and hotspots of O. hupensis control. Methods Chinese and English publications pertaining to O. hupensis control from 2005 to 2024 were retrieved in the Web of Science Core Collection Database and China National Knowledge Infrastructure. The annual number of publications was analyzed from 2005 to 2024, and the author and institution cooperation networks were mapped using the software CiteSpace 6.3.1. Keywords were extracted from publications to map the co-occurrence, burst and timeline of keywords to identify the research hotspots of O. hupensis control. Results A total of 158 English publications and 771 Chinese publications were included for bibliometric analyses. The overall output of English publications was relatively small from 2005 to 2024, the annual average publication was 7.90 publications. Parasites & Vectors was the most productive journal by the number of publications (21 publications). The three most productive authors included Li Shizhu (24 publications), Zhou Xiaonong (13 publications), and Yang Kun (12 publications), and the three most productive institutions included Chinese Center for Disease Control and Prevention (49 publications), the WHO (27 publications), and Fudan University (25 publications). The annual average number of Chinese publications was high from 2005 to 2015 (57.73 publications), and reduced to 15.11 publications during the period from 2016 to 2024, with Chinese Journal of Schistosomiasis Control as the most productive journal (241 publications). The three most productive authors included Wang Wanxian (18 publications), Sun Qixiang (16 publications), and Dai Jianrong (16 publications), and the three most productive institutions included Jiangsu Institute of Parasitic Diseases (55 publications), Chinese Center for Disease Control and Prevention (47 publications), and Hubei Uni-versity (38 publications). Among the 158 English publications, molluscicidal effect, climate change, geographic information, biological control, machine learning were current research hotspots, and the Yangtze River and elimination were emerging research hotspots. Among the 771 Chinese publications, molluscicidal effect, niclosamide, comprehensive management, molluscicide, effectiveness evaluation, marshland, and endophyte were current research hotspots, and the future research hotspots shifted to molluscicidal effect and pyriclobenzuron. Conclusions Limited attention is paid to the research on O. hupensis control across the world. The Yangtze River, elimination, molluscicidal effect, and pyriclobenzuron may be future research hotspots. High attention is recommended to be paid to the research on O. hupensis control, and development of diverse approaches for O. hupensis control is of urgent needs. We should continue to attach importance to the control research of O. hupensis and strengthen the exploration of diverse snail extermination and control methods.
2.Influence of atrial septal defect on mitral valve growth after repair of coarctation of the aorta or an interrupted aortic arch in infants
Yi-Chia WANG ; Heng-Wen CHOU ; Chi-Hsiang HUANG ; Hsing-Hao HUANG ; Yih-Sharng CHEN ; En-Ting WU ; Shyh-Jye CHEN ; Ming-Tai LIN ; Shuenn-Nan CHIU ; Shu-Chien HUANG
Clinical and Experimental Pediatrics 2026;69(4):322-329
Background:
Patients with coarctation of the aorta (CoA) and an interrupted aortic arch (IAA) may present with small mitral valves (MVs) and a reduced left ventricular (LV) volume. Biventricular repair (BVR) in these patients is dependent on adequate size of the left cardiac structures.Purpose: This study evaluated the impact of the hemodynamic characteristics of atrial septal defects (ASDs) on MV growth following surgical repair.
Methods:
We retrospectively reviewed the data of patients diagnosed with CoA or IAA between 2007 and 2024. The z score for MV size measured 6 months postoperatively (Z2) was compared with the preoperative MV size (Z1). The factors associated with MV growth were also studied.
Results:
A total of 161 patients with CoA or IAA were included. Transthoracic echocardiography was used to assess the MV and LV dimensions preoperatively and 6 months postoperatively. Of the cohort, 155 (96.3%) underwent initial BVR and 6 underwent single-ventricle palliation. MV z scores significantly increased following BVR (mean change: +0.45±1.35; P<0.001) but decreased after single-ventricle repair (-0.56±0.49, P=0.04). Multivariate analysis identified the initial MV z score and ASD pressure gradient as independent predictors of MV growth (R2=0.39).
Conclusion
Annular growth of the MV was not observed in patients who underwent single-ventricle palliation. In contrast, among patients who achieved BVR, those with a small preoperative MV annulus and low ASD pressure gradient demonstrated subsequent catch-up MV growth, suggesting that adequate left-sided preload is essential for MV development.
3.The first record of Anopheles messeae (Diptera: Culicidae) parasitized by water mites in China
Xue-ru CHEN ; Wen-zhen YAO ; Yu-hao LI ; Gui-chang LI ; Tao MENG ; Qun-ling FENG ; Xin-hui LIU ; Li-hong QIAO ; Xiang-ting WU ; Xue-feng ZHANG ; Cheng-lin LI ; Xue-cheng DONG ; Da-wei WANG ; Xiao-yan SI ; Yu-hong GUO
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):53-57
Objective This study reports on the obligatory parasitism of water mites Arrenurus sp. on Anopheles messeae at the Manzhouli Port, Inner Mongolia, China. Methods Duing July 2024, a survey on the mosquito diversity was conducted at the Manzhouli Port. Captured mosquitoes and their ectoparasites were identified to species level. Results A total of 1840 adult mosquitoes were collected, representing species from three genera: Culex(Cx. modestus, Cx. pipiens pallens), Aedes(Ae. dorsalis, Ae. flavidorsalis, Ae. flavescens), and Anopheles (An. messeae). Among all the mosqutioes specimens,3 out of 150 captured An. messeae were found to carry ectoparasitic mites, with number of 2,4,27 mites separately. Morphological and molecular identification reached the same result as water mites(Hydrachnidiae, Hydracrina). COI gene sequence showed 94% similarity with the closest species Arrenurus truncatellus. Conlusions Literature review suggests water mites are host-specific parasitism of mosquito species and herein with the first record of Arrenurus sp. parasiting on An. Messeae in the most high-latitude region globally.
4.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
5.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
6.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
7.CT signs and AI parameters predict colorectal cancer neoadjuvant chemotherapy efficacy
Guobin LAN ; Chuang LIU ; Hao WANG ; Hongyu MA ; Zeliang LI ; Wen CHEN ; Wenqiang ZHANG
Chinese Journal of Radiological Health 2025;34(5):713-719
Objective To explore the value of CT signs and quantitative parameters of artificial intelligence (AI) in predicting the efficacy of neoadjuvant chemotherapy for colorectal cancer. Methods A total of 349 colorectal cancer patients who received neoadjuvant chemotherapy at Cangzhou Hospital of Integrated Traditional Chinese and Western Medicine in Hebei Province from January 2022 to January 2025 were selected and and divided into the effective group (n = 267) and the ineffective group (n = 82) according to the evaluation criteria for the efficacy of solid tumors. Conduct a CT examination and extract AI quantitative parameters from the CT images based on the lesion. The data were analyzed using SPSS21.0 software, Logistic regression was used to screen the influencing factors of ineffective neoadjuvant chemotherapy in patients with colorectal cancer, and separate and combined models of CT signs and AI quantitative parameters were established. The predictive effect of the model was verified by using the ROC curve, calibration curve and decision curve. Results Compared with the effective group, the proportion of regular tumor morphology and the proportion of non-enlarged lymph nodesin the ineffective group were smaller. The tumor volume, peak value and entropy value were larger (P < 0.05). Multivariable analysis showed that irregular shape (OR= 4.216), presence of lymph node enlargement (OR = 8.998), larger tumor volume (OR = 1.109), higher average CT value (OR = 1.120), elevated peak value (OR = 2.528), and increased entropy value (OR = 1.390) were independent risk factors for ineffective neoadjuvant chemotherapy in colorectal cancer (P < 0.05). The areas under the ROC curves of the individual and combined models of CT signs and AI quantitative parameters were 0.777, 0.818, and 0.877, respectively(P < 0.05). The calibration curve showed a Brier score of 0.091. The decision curve showed that the threshold was between 0.10 and 0.85, and the combined model achieved a relatively high net clinical benefit. Conclusion CT signs combined with AI quantitative parameters has a predictive value for the efficacy of neoadjuvant chemotherapy in colorectal cancer. To provide evidence-based basis for clinical screening of the population benefiting from chemotherapy and optimization of treatment strategies.
8.Multi-omics analysis of hormesis effect of lanthanum chloride on carotenoid synthesis in Rhodotorula mucilaginosa.
Hong ZHANG ; Tong WEN ; Zhihong WANG ; Xin ZHAO ; Hao WU ; Pengcheng XIANG ; Yong MA
Chinese Journal of Biotechnology 2025;41(4):1631-1648
Hormesis effect has been observed in the secondary metabolite synthesis of microorganisms induced by rare earth elements. However, the underlying molecular mechanism remains unclear. To analyze the molecular mechanism of the regulatory effect of Rhodotorula mucilaginosa in the presence of lanthanum chloride, different concentrations of lanthanum chloride were added to the fermentation medium of Rhodotorula mucilaginosa, and the carotenoid content was subsequently measured. It was found that the concentrations of La3+ exerting the promotional and inhibitory effects were 0-100 mg/L and 100-400 mg/L, respectively. Furthermore, the expression of 33 genes and the synthesis of 55 metabolites were observed to be up-regulated, while the expression of 85 genes and the synthesis of 123 metabolites were found to be down-regulated at the concentration range of the promotional effect. Notably, the expression of carotenoid synthesis-related genes except AL1 was up-regulated. Additionally, the content of β-carotene, lycopene, and astaxanthin demonstrated increases of 10.74%, 5.02%, and 3.22%, respectively. The expression of 5 genes and the synthesis of 91 metabolites were up-regulated, while the expression of 35 genes and the synthesis of 138 metabolites were down-regulated at the concentration range of the inhibitory effect. Meanwhile, the content of β-carotene, lycopene, and astaxanthin decreased by 21.73%, 34.81%, and 35.51%, respectively. In summary, appropriate concentrations of rare earth ions can regulate the synthesis of secondary metabolites by modulating the activities of various enzymes involved in metabolic pathways, thereby exerting the hormesis effect. The findings of this study not only contribute to our comprehension for the mechanism of rare earth elements in organisms but also offer a promising avenue for the utilization of rare earth elements in diverse fields, including agriculture, pharmaceuticals, and healthcare.
Lanthanum/pharmacology*
;
Rhodotorula/genetics*
;
Carotenoids/metabolism*
;
Hormesis/drug effects*
;
Fermentation
;
Multiomics
9.Hepatolenticular Degeneration With Primary Liver Cancer:Report of One Case and Review of the Literature.
Hui WANG ; Jia-Lin DU ; Qing-Ya YANG ; Dian-Dian HAO ; Ming-Yuan ZHANG ; Xiao-Yu WEN
Acta Academiae Medicinae Sinicae 2025;47(2):319-324
Hepatolenticular degeneration is a rare disease,and the number of cases of primary liver cancer occurring on the basis of liver cirrhosis caused by hepatolenticular degeneration is very small.This paper reports a case of hepatolenticular degeneration with primary liver cancer,and then reviews and summarizes current cases of this disease both domestically and internationally.
Humans
;
Hepatolenticular Degeneration/complications*
;
Liver Neoplasms/complications*
10.Interstitial Lung Disease With CA19-9 Elevation After Oxaliplatin and Capecitabine Adjuvant Therapy for Ileocecal Carcinoma:Report of One Case.
Wen-Jing YANG ; Guo-Wang YANG ; Ying LI ; Hao WANG ; Lin YANG ; Wei-Ru XU
Acta Academiae Medicinae Sinicae 2025;47(4):660-665
Both carcinoembryonic antigen and CA19-9 are considered as predictive markers of intestinal cancer recurrence and metastasis.In addition,CA19-9 elevation is considered as a predictive marker of connective tissue disease-related interstitial lung disease.The incidence of oxaliplatin and capecitabine-associated interstitial lung disease is low,and there is no report about CA19-9 as a predictive marker of oxaliplatin and capecitabine-associated interstitial lung disease.This paper reports a case of interstitial lung disease with CA19-9 elevation caused by oxaliplatin and capecitabine adjuvant therapy for ileocecal carcinoma.The change trend of serum carcinoembryonic antigen in this patient was consistent with tumor recurrence and metastasis,and that of serum CA19-9 was consistent with the severity of interstitial lung disease.Therefore,CA19-9 elevation after intestinal cancer surgery does not necessarily indicate the tumor recurrence and metastasis,and attention should be paid to the possibility of oxaliplatin and capecitabine-associated interstitial lung disease.
Humans
;
CA-19-9 Antigen/blood*
;
Capecitabine
;
Cecal Neoplasms/drug therapy*
;
Chemotherapy, Adjuvant
;
Deoxycytidine/administration & dosage*
;
Fluorouracil/administration & dosage*
;
Lung Diseases, Interstitial/blood*
;
Organoplatinum Compounds/administration & dosage*
;
Oxaliplatin


Result Analysis
Print
Save
E-mail