1.Differential expression and functional analysis of plasma tRF and tiRNA in collagen-induced arthritis rats
Daiyi CHEN ; Yuqi WEN ; Cailin HE ; En HU ; Zhaoyu YANG ; Xingui XIONG ; Bo YANG
Chinese Journal of Immunology 2025;41(5):1041-1047
Objective:To explore the differentially expressed tRNA-derived RNA fragment(tRF)and tRNA halves(tiRNA)in plasma of collagen-induced arthritis(CIA)rats,analyze the biological functions and related pathways of the tRF and tiRNAs target genes in order to identify new targets for diagnosis and therapy of rheumatoid arthritis(RA).Methods:Rat model of RA was estab-lished by injecting typeⅡ collagen.Arthritis index(AI)score and HE staining were conducted to evaluate the successfully establishment model.Illumina platform was used to obtain the tRF and tiRNA expression profiles.RT-qPCR was performed to validate expressions of tRF and tiRNA.Combining miRanda and TargetScan databases,the target genes of differentially expressed tRF and tiRNA were ob-tained.GO and KEGG enrichment analysis were used to annotate the functions of target genes.Results:A total of 25 tRFs and tiRNAs were significantly differentially expressed in plasma in rats after modeling,of which 23 were up-regulated and 2 were down-regulated.Besides,six specifically expressed tRFs and tiRNAs induced by CIA rats were screened,including Other-36:73-tRNA-Arg-CCT-4,Other-57:70-tRNA-Glu-CTC-1-M3,tRF-1:32-Gly-CCC-1-M2,tRF-1:31-Gly-CCC-1-M2,tRF-1:32-Pro-AGG-1-M4 and tRF-1:32-Glu-TTC-2-M2.GO analysis of target genes mainly involved organelle-associated items.What's more,KEGG analysis enriched multi-ple classical signal pathways associated with RA.Conclusion:Target genes of differentially expressed tRFs and tiRNAs in CIA rats may be involved in regulating important pathophysiological processes of RA and drug therapy targets.
2.Compound sabal berry tablets for the treatment of overactive bladder symptoms after laser enucleation of the prostate in patients with benign prostatic hyperplasia
Gai HANG ; Quan WEN ; Ying LIU ; Yunpeng GUO ; Yuyang WANG ; Zhiyu YU ; Bo CHEN
Chinese Journal of Primary Medicine and Pharmacy 2025;32(9):1315-1319
Objective:To investigate the clinical efficacy of compound sabal berry tablets on overactive bladder symptoms in patients with benign prostatic hyperplasia after transurethral laser enucleation of the prostate.Methods:This study was a prospective study. Eighty patients with benign prostatic hyperplasia who underwent laser enucleation at Tongliao People's Hospital from January 2024 to December 2024 were included in this study. The patients were randomly divided into a study group and a control group using the random number table method, with 40 patients per group. The control group received 0.2 mg of tolterodine tartrate tablets twice a day after surgery. The study group was given compound sabal berry tablets (0.5 g orally three times a day) in addition to the treatment provided to the control group. Both groups of patients were treated for 4 weeks after surgery. The clinical efficacy of the two groups was compared, including the International Prostate Symptom Score (IPSS), Overactive Bladder Symptom Score (OABSS), Maximum Postoperative Urinary Flow Rate (Qmax), Post-Void Residual (PVR), and the incidence of postoperative bladder irritative symptoms.Results:The differences in the preoperative indicators, including IPSS, OABSS, Qmax, and PVR, between the two groups were not statistically significant (all P > 0.05). Preoperatively, in the control group, Qmax was (8.64 ± 2.83) mL/s, IPSS was (25.10 ± 4.37), OABSS was (10.52 ± 1.87), and PVR was (80.70 ± 6.34) mL; in the study group, the respective values were (9.12 ± 2.95) mL/s, (24.60 ± 4.53), (10.83 ± 1.73), and (80.10 ± 5.61) mL. Postoperatively, in the control group, Qmax was (20.30 ± 3.65) mL/s, IPSS was (8.50 ± 1.58), OABSS was (4.09 ± 0.52), and PVR was (9.70 ± 2.48) mL, while in the study group, the respective values were (21.40 ± 4.38) mL/s, (7.40 ± 1.76), (1.71 ± 0.36), and (9.00 ± 1.75) mL. Postoperatively, both groups showed a significant increase in Qmax, while IPSS, OABSS, and PVR all significantly decreased (all P < 0.05). Postoperatively, the IPSS and OABSS in the study group were significantly lower than those in the control group ( t = -3.28, -25.89, both P < 0.05). However, there were no statistically significant differences in Qmax and PVR between the two groups (both P > 0.05). The incidence of bladder irritative symptoms in the study group [12.50% (5/40)] was significantly lower than that in the control group [35.00% (14/40), χ2 = 8.64, P < 0.05]. Conclusions:Compound sabal berry tablets can reduce postoperative prostate symptoms and overactive bladder symptoms in patients undergoing transurethral laser enucleation of the prostate for benign prostatic hyperplasia, demonstrating a certain clinical efficacy.
3.Automated syndrome element differentiation in traditional Chinese medicine based on large language models and text embedding computation
Zhaoyang SUN ; Yang WANG ; Mingze MA ; Yanwen CHEN ; Zhenxiu LYU ; Tiantian JIANG ; Huiling WEN ; Bo CHEN ; Jing GUAN
Journal of Beijing University of Traditional Chinese Medicine 2025;48(8):1176-1184
Objective This study aimed to develop an automated method for syndrome element differenti-ation in Traditional Chinese Medicine(TCM).Methods We first constructed and trained an Instruction-tuned Multi-Task TCM text embedding model(Instr-MT-TCM)using four distinct TCM task datasets,including domain knowledge,synonymous terminology,syndrome differentiation and treatment,and TCM case labels.Subsequently,five TCM diagnostics experts holding master's degrees or higher were organized to screen a real-world TCM case dataset and annotate symptoms and signs.The purpose was to evaluate the F1-score of the proposed method—the combination of Instr-MT-TCM and a Large Language Model(LLM)—by comparing its performance against the manual annotation result on the syndrome element differentiation task.Finally,to validate its feasibility in real-world clinical settings,the method was applied to 48 prostate cancer cases to calculate the syndrome element scores.Results The Instr-MT-TCM model showed rapid performance improvement in its early training phase,achieving a Recall@1(R@1)of 0.848.Experts curated a dataset of 1,793 real-world clinical cases,covering 34 common diseases and 66 syndrome patterns.In the syndrome element differentiation task,the collaborative framework of LLM and Instr-MT-TCM achieved a mean F1-score of 0.927,outperforming the 0.512 from manual annota-tion.The syndrome element analysis revealed that the predominant elements of disease nature were fire(heat)and yin deficiency,while the main elements of disease location were bladder and kidney.Conclusion This study proposes and validates a novel method for automated TCM syndrome element dif-ferentiation based on the synergy between LLM and our custom Instr-MT-TCM model.Achieving a high F1-score(0.927)on real-world data,the method demonstrates excellent accuracy and generalization ability.Its application in prostate cancer analysis highlights its significant clinical potential,offering effective technical support,and a new research direction for intelligent TCM syndrome element differentiation.
4.Advances of Metal-Organic Framework Stationary Phases for Gas Chromatographic Separations
Yan JIN ; Wen-Bo LI ; Yu-Chen ZHU ; Bin ZHAO ; Lei LI ; Dan ZHENG ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(1):1-13
Metal-organic frameworks(MOFs)are porous materials composed of metal ions or metal clusters and organic ligands by coordination,which have the advantages of large specific surface area,good thermal stability and adjustable pore size,and have a promising application in gas chromatographic separation.In recent years,MOFs materials have been used as stationary phases for gas chromatography mainly including ZIF,MIL,UiO-66,HKUST-1,IRMOFs,etc.Based on the molecular sieve effect,van der Waals forces,hydrogen bonding and π-π interactions,the pore size,pore microenvironment,unsaturated metal site and special functional group of the MOFs stationary phase materials can be specifically designed and regulated.MOFs materials as stationary phases have unique separation performance for n-alkanes and their isomers,aromatic compounds and their isomers,alcohols/ketones/aldehydes and their isomers,and chiral compounds.The combination of organic polymers and novel nanomaterials with MOFs materials can improve the separation performance and stability of MOFs.Therefore,MOFs materials are expected to be the promising stationary phase that can be applied to gas separation in complex environments.In this article,the research advances of various stationary phases based on MOFs for gas chromatography in recent years were reviewed.The separation performance and separation mechanism of MOFs stationary phases for mixed gas samples were discussed,and the development trends in the future were prospected.
5.Development and Performance Test of Dielectric Barrier Discharge Ionization Source with Rapid Evaporation and Self-aspiration Sampling
Shuo ZHANG ; Xin-Xin LU ; Yu-Lin CHEN ; Xu-Jie DENG ; Bo-Wen WANG ; Xiao-Xu LI
Chinese Journal of Analytical Chemistry 2025;53(4):561-567
A dielectric barrier discharge ionization source with rapid evaporation and self-aspiration sampling(RE-SADBDI)was developed,integrating a rapid evaporation(RE)module and a dielectric barrier discharge ionization(DBDI)module.The sample was introduced into the RE module via a sampling swab and rapidly vaporized within it.The sealed design of the ionization source could enable the sample to be self-aspirated into the ionization region without the need of additional inert gas.All vaporized sample was efficiently directed into the ionization region due to the relatively enclosed environment for sample transfer and ionization,resulting in improved transfer and ionization efficiencies.Experimental results showed that the limit of detection(LOD)under ion isolation mode reached 0.05 ng/mL(caffeine),with a relative standard deviation(RSD)of 6.9%.Furthermore,when coupled with a miniaturized linear ion trap mass spectrometer,the source enabled real-time analysis of various sample types.The developed RE-SADBDI source was suitable for on-site analysis with miniaturized mass spectrometers.
6.A Pneumatic Micro-valve with Sandwich Structure Based on Micro-electro-mechanical System
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(5):758-764
In this study,an ON/OFF type micro-valve with a sandwich(glass-silicon-glass)structure was designed and fabricated based on the micro-electro-mechanical system(MEMS)technique.The deformable membrane of this micro-valve was prepared on the silicon on insulator(SOI)substrate and sealed using Si-Si bonding and anodic bonding methods.The micro-valve had high-temperature stability and was suitable for integration with other gas chromatography components.The deformable membrane with a thickness of 10 μm was processed on the top silicon of the SOI substrate.The flow control of the micro-valve could be achieved by changing the driving pressure applied to the deformable membrane to deform it.Compared with polymer membranes,the deformable membrane prepared on the top layer silicon of SOI had better temperature stability and could be released using the deep reactive ion etching technique after silicon-silicon bonding,avoiding deformation during the preparation process.In addition,due to the small gap between the membrane and the inlet/outlet holes,the dead volume of the microvalve was very small.The test results indicated that the micro-valve achieved flow control and ON/OFF functions with good repeatability.
7.A Monolithic Integrated Gas Chromatography Chip with Gas Chromatographic Column and Helium Discharge Ionization Detector
Yu-Chen ZHU ; Shao-Jie MA ; Wen-Bo LI ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(7):1064-1071
A monolithic integrated gas chromatography chip,consisting of a micro gas chromatography column(μGCC)and a micro helium discharge ionization detector(μHDID)was proposed.The chip was fabricated using micro electromechanical system(MEMS)technique,and its sensitivity was improved from two aspects.On one hand,open tubular column was selected as the separation device,and the auxiliary helium channel width of μHDID was modulated based on the microchannel width of the μGCC to match the flow rates of μHDID and μGCC.On the other hand,the electrode structure inside the μHDID collection zone was optimized,a bias electrode group around the collection electrode was constructed,and the ion collection efficiency was improved.After coating HKUST-1 as the stationary phase,the monolithic integrated gas chromatography chip could achieve baseline separation and detection of light hydrocarbon gas mixture(methane,ethane,propane,andn-butane),with a detection limit for propane as low as 25 pg.The chip could carried out test under temperature-programmed conditions,with a resolution of 9.24 for ethane and propane.
8.A Micro Gas Chromatographic Column with Large Surface Area Based on Anodization
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Bo-Xin CHEN ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(10):1607-1614
A micro gas chromatographic column with mesoporous surface micro column array prepared by anodization method was proposed.A porous support layer with a characteristic pore size of about 30 nm inside the chromatographic column was prepared in situ using anodization method,and a uniform alumina stationary phase was deposited on the mesoporous support layer using atom layer deposition(ALD)technique.The existence of a mesoporous support layer increased surface area of the chromatographic column,thereby increasing the total amount of stationary phase loading and enhancing column capacity,which facilitated chromatographic separation.The test results showed that the porous support layer significantly reduced the longitudinal molecular diffusion and mass transfer resistance of the micro gas chromatographic column,and significantly increased the number of theoretical plates(n-nonane increased by 290.2%).Furthermore,column efficiency of the chromatographic column was less affected by flow rate,which was conducive to rapid separation of heavy hydrocarbon mixtures.
9.Creation and Exploration of the"Organized Fill-in-the-Blank Format"Disci-pline Construction Model for Forensic Medicine in the New Era
Zhi-Wen WEI ; Hong-Xing WANG ; Jun-Hong SUN ; Hao-Liang FAN ; Hong-Liang SU ; Le-Le WANG ; Wen-Ting HE ; Zhe CHEN ; Jie ZHANG ; Xiang-Jie GUO ; Ji LI ; Geng-Qian ZHANG ; Xin-Hua LIANG ; Jiang-Wei YAN ; Qiang-Qiang ZHANG ; Cai-Rong GAO ; Ying-Yuan WANG ; Hong-Wei WANG ; Jun XIE ; Bo-Feng ZHU ; Ke-Ming YUN
Journal of Forensic Medicine 2025;41(1):25-29
Forensic medicine has been designated as a first-level discipline,presenting new opportunities and challenges for the development of forensic medicine.Since the 1980s,the establishment of foren-sic medicine discipline and the cultivation of high-level forensic talents have become hot topics in the development of forensic medicine in China.Since the 13th Five-Year Plan,the forensic team of Shanxi Medical University has been aiming at the forefront,proposing the development goals of"Five First-class"and the discipline development path"Six Major Achievements".It has selected benchmark disci-plines,identified gaps in disciplinary development,unified thoughts,formulated completion timelines,concentrated superior resources,assigned tasks to individuals,and created an"Organized Fill-in-the-Blank Format"forensic medicine discipline construction model with the characteristics of the new era.The construction model of forensic medicine has achieved good results in the goals,discipline frame-work,scientific research,talent cultivation,discipline team and platform construction,forming a rela-tively complete discipline construction and management system,and accumulating valuable experience for the construction of first-level discipline and high-level talent cultivation of forensic medicine.
10.Detection of Ketamine and Norketamine Using an Aptamer-Functionalized Gra-phene Oxide Fluorescent Sensor
Li-Xia WEI ; Bo LIU ; Xiao-Yuan YANG ; Xi ZHANG ; Yi-Feng LAN ; Chao ZHANG ; Juan JIA ; Dan ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Zhe CHEN
Journal of Forensic Medicine 2025;41(4):326-339
Objective To construct an aptamer-functionalized carboxylated graphene oxide(CGO)fluo-rescent sensor to achieve highly sensitive and specific detection of ketamine(KET)and its metabolite norketamine(NK)using an aptamer capable of simultaneously recognizing KET and NK.Methods A specific aptamer for simultaneous recognition of KET and NK was screened using graphene oxide-sys-tematic evolution of ligand by exponential enrichment(GO-SELEX)and molecular docking tech-niques.The aptamer,labeled with Cy5 fluorescence,was chemically conjugated to CGO to construct an aptamer-functionalized CGO fluorescent sensor.By optimizing detection conditions,including the mass concentration of CGO,aptamer concentration,reaction temperature,and incubation time,quantita-tive analysis of the target analytes was achieved using the ratio of fluorescence intensity changes be-fore and after target addition.The stability of the sensor in biological matrices was evaluated by moni-toring fluorescence intensity changes over incubation time in blank blood and urine,in comparison with the traditional physical adsorption-based CGO fluorescent sensor.Spiked recovery experiments in blank blood and urine were conducted to compare performance with that of HPLC-MS/MS.Results A specific aptamer A5 was selected and chemically conjugated with CGO to construct the aptamer-functionalized CGO fluorescent sensor.Under optimized conditions,the proposed fluorescent sensor ex-hibited a linear detection range of 1.0-5.0 ng/mL for KET,with a limit of detection(LOD)of 0.86 ng/mL;while for NK,the linear detection range was 1.0-5.0 ng/mL,with an LOD of 0.70 ng/mL.Com-pared with the CGO fluorescent sensor constructed via physical adsorption,this sensor demonstrated greater stability in blood and urine.The spiked recovery rates of KET and NK in blank blood and urine ranged from 81.50%to 110.03%,exhibiting detection performance comparable to that of HPLC-MS/MS.Conclusion The aptamer screening method offers a novel approach for selecting aptamers tar-geting drugs and their metabolites.The constructed aptamer-functionalized CGO fluorescent sensor pro-vides an efficient and reliable strategy for the high-performance detection of KET and NK.

Result Analysis
Print
Save
E-mail