1.Experience of parents engaging in kangaroo mother care for preterm infants in the NICU:a qualitative Meta-synthesis
Weizhen ZOU ; Liqing YUE ; Bingyu LI ; Xiuwen CHEN ; Bin PENG ; Tiange ZHANG ; Qiang PENG ; Huiqiong CHEN ; Moyan LIU
Chinese Journal of Nursing 2025;60(20):2534-2541
Objective To systematically evaluate and analyze qualitative studies of parental engagement in kangaroo mother care experiences for preterm infants in the NICU,aiming to provide references for promoting the early recovery of preterm infants in NICU and improving the quality of nursing services.Methods Relevant were searched for qualitative studies of parental engagement in kangaroo mother care for preterm infants in NICU.The search time limit was from the construction of the database to July 19,2024.The quality of the included literature was assessed using the Joanna Brigg Institute's(JBI)Australian Centre for Evidence-Based Health Care's Quality Assessment Criteria for Qualitative Research,and the results were integrated using the meta-integration methods.Results A total of 17 papers were included in the literature,and 61 findings were extracted,grouped into 10 new categories.These were further synthesized into 4 integrated findings:physical and psychological perceptions of participation in kangaroo mother care;challenges to participation in kangaroo mother care;facilitators of participation in kangaroo mother care;expectations and suggestions for kangaroo mother care.Conclusion Hospital administrators should further improve the management specifications of kangaroo mother care for preterm infants in NICU,optimize resource allocation and strengthen publicity.At the same time,healthcare professionals should actively promote the establishment of peer and family support systems and increase participation in kangaroo mother care to facilitate early recovery of preterm infants in NICU and to continuously promote the improvement of nursing service quality.
2.Dentate Gyrus Morphogenesis is Regulated by an Autism Risk Gene Trio Function in Granule Cells.
Mengwen SUN ; Weizhen XUE ; Hu MENG ; Xiaoxuan SUN ; Tianlan LU ; Weihua YUE ; Lifang WANG ; Dai ZHANG ; Jun LI
Neuroscience Bulletin 2025;41(1):1-15
Autism Spectrum Disorders (ASDs) are reported as a group of neurodevelopmental disorders. The structural changes of brain regions including the hippocampus were widely reported in autistic patients and mouse models with dysfunction of ASD risk genes, but the underlying mechanisms are not fully understood. Here, we report that deletion of Trio, a high-susceptibility gene of ASDs, causes a postnatal dentate gyrus (DG) hypoplasia with a zigzagged suprapyramidal blade, and the Trio-deficient mice display autism-like behaviors. The impaired morphogenesis of DG is mainly caused by disturbing the postnatal distribution of postmitotic granule cells (GCs), which further results in a migration deficit of neural progenitors. Furthermore, we reveal that Trio plays different roles in various excitatory neural cells by spatial transcriptomic sequencing, especially the role of regulating the migration of postmitotic GCs. In summary, our findings provide evidence of cellular mechanisms that Trio is involved in postnatal DG morphogenesis.
Animals
;
Dentate Gyrus/metabolism*
;
Mice
;
Morphogenesis/physiology*
;
Neurons/pathology*
;
Cell Movement
;
Mice, Inbred C57BL
;
Autism Spectrum Disorder/pathology*
;
Mice, Knockout
;
Neural Stem Cells
;
Male
;
Neurogenesis
;
Autistic Disorder/genetics*
3.Association between long-term exposure to low-dose ionizing radiation and metabolic syndrome among medical radiologists
Changyong WEN ; Xiaoman ZHOU ; Xiaolian LIU ; Yiqing LIAN ; Weizhen GUO ; Yanting CHEN ; Xin LAN ; Mingfang LI ; Sufen ZHANG ; Weixu HUANG ; Jianming ZOU ; Huifeng CHEN
Journal of Environmental and Occupational Medicine 2025;42(10):1209-1215
Background In recent years, the increasingly widespread application of nuclear and medical radiation technologies has resulted in a large number of occupational populations exposed to low-dose ionizing radiation (LDIR). At present, there is no consistent conclusion on the effects of long-term exposure to LDIR on the metabolic health of the occupational population. Objective To explore the association between long-term exposure to LDIR and metabolic syndrome (MetS) among medical radiologists. Methods A cross-sectional study was conducted to enroll
4.Clinical study of targeted epidural space block combined with acupotomy in the treatment of lumbar disc herniation under X-ray guidance
Yingzheng ZHANG ; Yadong WANG ; Xiaoyue DENG ; Lu CAI ; Weizhen WANG ; Qiuxia YANG ; Yafang SUN ; Feifei LIU
China Medical Equipment 2025;22(3):68-72
Objective:To explore the clinical efficacy of targeted epidural space block combined with acupotomy in the treatment for lumbar disc herniation(LDH)under the monitor of X-ray image,and to analyze the safety of its operation.Methods:A total of 60 LDH patients who admitted to Department of Pain,Jiangyin Affiliated Hospital of Nanjing University of Chinese Medicine from January 2022 to September 2023 were selected,and they were randomly divided into observation group and control group as random number table,with 30 cases in each group.The observation group adopted targeted epidural space block combined with acupotomy under monitor with X-ray for anterior epidural space,while the control group adopted conventionally epidural block,all of which were treated only once.The Visual Analogue Scale(VAS)scores and Oswestry Disability Index(ODI)scores of two groups before treatment and at the 3rd day,7th day and 30th day after treatment were compared.At the 30th day after treatment,the curative effects of two groups were evaluated according to ODI scores,at the same time,the safe distance between puncture and acupotomy in patients of observation group was analyzed.Results:The effective rates of the treatment of observation group and control group were respectively 96.67%and 70%,and the difference of that between the two groups was statistically significant(x2=7.680,P<0.05).The VAS scores of the two groups at the 3rd day,7th day and 30th day after treatment were lower than those before treatment,and the observation group(2.30±0.87),(1.53±0.86)and(1.47±0.81)were lower than the control group(4.43±0.89),(2.23±0.89)and(4.27±0.82),the difference was statistically significant(t=9.374,3.098,13.306,P<0.05).The ODI scores of the two groups were at the 3rd day,7th day and 30th day after treatment were lower than those before treatment,and the differences of them between two groups were statistically significant(t=7.112,10.690,10.151,P<0.05).In 30 patients of observation group,the gap between the dural sac and the inner edge of facet joint on the affected side was larger than 4.0mm in 25 cases,and all of them can safely conduct puncture with targeting.Conclusion:The targeted epidural space block combined with acupotomy by adopting monitor with X-ray image can effectively improve the symptom of pain,and activities of daily life of LDH patients,which treatment is safe and effective.
5.The clinical efficacy of retrograde tibial intramedullary nail combined with lateral less invasive stabilization system in the treatment of distal femoral fractures
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Weibin LIN ; Jin WU
Chinese Journal of Orthopaedics 2025;45(4):197-204
Objective:To explore the clinical efficacy of retrograde tibial intramedullary nail (RTN) combined with less invasive stabilization system (LISS) in the treatment of distal femoral fractures.Methods:A retrospective analysis was conducted on the data of 11 patients with distal femoral fractures who underwent RTN combined with LISS locking plate treatment at the 909th Hospital from June 2021 to December 2022. There were 5 males and 6 females, with an average age of 56.5±17.5 years. The fracture types were AO/OTA 33A2 in 2 cases, A3 in 2 cases, C1 in 2 cases, and C2 in 2 cases. There were 3 cases of periprosthetic femoral fractures after total knee arthroplasty (TKA), all classified as Rorabeck type Ⅱ. They were treated with retrograde intramedullary nailing of the tibia combined with a minimally invasive lateral internal fixation system. The operation time, intraoperative blood loss, fracture healing time, full weight-bearing time, femorotibial angle, range of motion (ROM) of the knee joint, Hospital for Special Surgery (HSS) score, visual analogue scale (VAS) for pain, and complications were recorded.Results:The operation was successfully completed in all 11 cases. The operation time was 98.3±9.0 min (range 83-115 min), and the intraoperative blood loss was 167.8±24.3 ml (range 120-210 ml). All 11 cases were followed up for 11.0±1.9 months (range 9-15 months). The healing time of 11 cases was 5.3±0.8 months (range 4-6 months) after operation. The time of complete weight-bearing activity after operation was 55.7±6.5 d (range 46-67 d). At the last follow-up, the femoral-tibial angle of 11 cases was 171.2°±1.8° (range 169°-174°), the ROM of knee joint was 129.5°±4.7° (range 120°-135°), and the HSS score was 86.8±6.9 points (range 69-95 points). There were no major complications except for one case of superficial infection of surgical incision after operation.Conclusion:RTN combined with lateral LISS locking plate showed good clinical effect with the advantages of less trauma, reliable fixation, rapid recovery, less postoperative complications.
6.Finite element analysis of three internal fixation methods for type AO/OTA A3 distal femoral fractures
Jinhui ZHANG ; Hui LIU ; Weizhen XU ; Yuanfei XIONG ; Jianping ZHANG ; Jin WU
Chinese Journal of Tissue Engineering Research 2025;29(27):5728-5734
BACKGROUND:The age distribution of patients with distal femur fracture is bimodal,being more common in young adults with high-energy injuries and older individuals with low-energy injuries.In cases of complex distal femoral fractures,a single less invasive stabilization system or retrograde femoral nail is insufficient to provide a stable environment for fracture healing and combined fixation is often necessary.OBJECTIVE:A novel combined fixation method(less invasive stabilization system combined with retrograde tibial nail)was developed for the treatment of type A3 distal femur fractures.Using finite element analysis,the bio-mechanical properties of this method were compared with two common combined fixation methods—dual plate(less invasive stabilization system combined with locking compression plate)and nail plate combination(less invasive stabilization system combined with retrograde femoral nail).This study aims to provide a theoretical basis for the selection of clinical internal fixation methods for distal femur fracture.METHODS:CT images of a 23-year-old healthy male volunteer were utilized to reconstruct the femur three-dimensional model using Mimics and Geomagic Studio software.This model was then compared with in vitro finite element analysis data from existing literature to validate the accuracy of the femoral three-dimensional model.The three-dimensional model of type A3 distal femur fractures and internal fixation were then created using Creo 5.0 software.Three kinds of different combined fixation methods(less invasive stabilization system+retrograde tibial nail,less invasive stabilization system+locking compression plate,less invasive stabilization system+retrograde femoral nail)were assembled and subjected to Boolean operation to establish three sets of finite element models.These models were then imported into Abaqus finite element analysis software to assign material properties,apply consistent boundary conditions,and submit calculations under three loads(normal standing,slow walking,and descending stairs).The resulting stress distribution within the internal fixation as well as overall and local deformation of the femur was analyzed.Furthermore,the failure risk and anti-deformation ability of the new combined fixation method(less invasive stabilization system combined with retrograde tibial nail)were evaluated.RESULTS AND CONCLUSION:(1)Although the anti-deformation ability of the less invasive stabilization system combined with retrograde tibial nail was approximately 10%lower than that of the less invasive stabilization system combined with locking compression plate,it was comparable to that of less invasive stabilization system combined with retrograde femoral nail and demonstrated good anti-deformation ability.(2)The stiffness of the femur with all three combined fixation methods remained consistent during gait,while femur displacement increased linearly with load,indicating high stability.(3)The failure risk associated with less invasive stabilization system combined with retrograde tibial nail was lower than that of the other two methods,with a 2.94%reduction in failure risk compared to less invasive stabilization system combined with locking compression plate.(4)This new combined fixation method offers distinct advantages in terms of anti-deformation ability,safety,and effectiveness,laying a theoretical foundation for further clinical application.
7.Analysis on appraisal of ophthalmic medical malpractice
Weizhen CHEN ; Zhitao GE ; Shi LIU ; Zhihu ZHANG ; Lihong LIU ; Jiaqi ZHANG ; Shuangxue HAN
Chinese Journal of Forensic Medicine 2025;40(4):415-419
Objective To identify the key points of forensic appraisal in ophthalmic medical-injury compensation cases and propose targeted measures to prevent disputes.Methods A retrospective analysis was conducted of the appraisal conclusions from 15 ophthalmology medical-injury liability lawsuits handled at a single tertiary hospital over the past five years.We summarized the constitutive characteristics of liability cases,causes of medical injury,and issues encountered during appraisal.Results Among cases undergoing medical-injury liability appraisal,retinal diseases and ocular tumors predominated.The main issues included inadequate informed consent,failure to exercise due care during surgery/treatment,non-standard medical record documentation,insufficient attention to medical risks,and inadequate clinical assessment.Conclusions By summarizing common faults in ophthalmic disputes and problems revealed by forensic appraisal,targeted responses can be implemented to ensure patient safety and promote high-quality medical services.
9.Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures.
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Jin WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):673-679
OBJECTIVE:
To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures.
METHODS:
A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex.
RESULTS:
No significant difference was observed in operation time between the two groups ( P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex ( P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups ( P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group ( P<0.05).
CONCLUSION
Compared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Aged
;
Adult
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Surgery, Computer-Assisted/methods*
;
Fluoroscopy
10.Analysis on appraisal of ophthalmic medical malpractice
Weizhen CHEN ; Zhitao GE ; Shi LIU ; Zhihu ZHANG ; Lihong LIU ; Jiaqi ZHANG ; Shuangxue HAN
Chinese Journal of Forensic Medicine 2025;40(4):415-419
Objective To identify the key points of forensic appraisal in ophthalmic medical-injury compensation cases and propose targeted measures to prevent disputes.Methods A retrospective analysis was conducted of the appraisal conclusions from 15 ophthalmology medical-injury liability lawsuits handled at a single tertiary hospital over the past five years.We summarized the constitutive characteristics of liability cases,causes of medical injury,and issues encountered during appraisal.Results Among cases undergoing medical-injury liability appraisal,retinal diseases and ocular tumors predominated.The main issues included inadequate informed consent,failure to exercise due care during surgery/treatment,non-standard medical record documentation,insufficient attention to medical risks,and inadequate clinical assessment.Conclusions By summarizing common faults in ophthalmic disputes and problems revealed by forensic appraisal,targeted responses can be implemented to ensure patient safety and promote high-quality medical services.

Result Analysis
Print
Save
E-mail