1.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
2.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
3.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
4.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
6.Occupational health literacy among key populations in the tertiary industry in Lu'an City
LIU Lei ; CHENG Tingting ; QIAN Chunsheng ; HUANG Rui ; LI Ting ; TANG Kun ; WEI Dong ; SU Yiwen ; LI Haowei ; LI Pengfei
Journal of Preventive Medicine 2025;37(11):1179-1183
Objective:
To analyze the occupational health literacy (OHL) level and its influencing factors among key populations in the tertiary industry in Lu'an City, Anhui Province, so as to provide a basis for developing targeted health interventions and improving regional occupational health policies.
Methods:
A stratified cluster random sampling method was employed to select five categories of key populations from the tertiary industry in Lu'an City as study subjects from August to September 2024. Data on gender, age, education level, and OHL were collected through the National OHL Monitoring Questionnaire for Key Populations. The OHL levels were analyzed, and influencing factors of OHL levels among key populations were analyzed using a multivariable logistic regression model.
Results:
A total of 1 243 individuals were surveyed, comprising 700 (56.32%) males and 543 (43.68%) females. The median age was 42.00 (interquartile range, 17.00) years. There were 609 individuals with OHL, and the OHL level was 48.99%. The OHL levels in fundamental knowledge of occupational health protection, healthy work styles and behaviors, knowledge of occupational health laws, and basic skills for occupational health protection were 84.71%, 60.34%, 43.93%, and 37.09%, respectively. Multivariable logistic regression analysis showed that educational level (primary school and below, OR=0.149, 95%CI: 0.064-0.344; junior high school, OR=0.340, 95%CI: 0.184-0.629; high school, OR=0.408, 95%CI: 0.230-0.723), average monthly personal income (3 000-<5 000 yuan, OR=1.655, 95%CI: 1.092-2.508; 5 000-<7 000 yuan, OR=2.195, 95%CI: 1.302-3.699; ≥7 000 yuan, OR=2.062, 95%CI: 1.016-4.183), employer nature (private enterprises, OR=2.992, 95%CI: 1.569-5.443), and industry category (education, OR=3.423, 95%CI: 1.407-8.327; courier / food delivery services, OR=0.459, 95%CI: 0.268-0.787; healthcare, OR=7.539, 95%CI: 3.255-17.461) were statistically associated with the OHL level among key population.
Conclusion
The OHL level among key population in the tertiary industry of Lu'an City can be further enhanced, with educational level, average monthly personal income, employer nature, and industry category identified as the primary influencing factors.
7.Choice of extraction media for Ni release risk evaluation on nickel-titanium alloys cardiovascular stents
Bin LIU ; Yang QIN ; Xiaoman ZHANG ; Changyan WU ; Dongwei WANG ; Wenli LI ; Cheng JIN ; Yunfan DONG ; Yiwei ZHAO ; Lili LIU ; Wei XIONG
International Journal of Biomedical Engineering 2024;47(2):156-161
Objective:To determine the content of the released nickel ion through the 7 extraction media to extract the Ni-Ti wires and to plot the curve of the released nickel ion so as to identify a leaching medium that can be substituted for blood for in vitro Ni release evaluation. Methods:The release of Ni through microwave digestion/inductively coupled plasma mass spectrometry (ICP-MS) in the goat serum was determined. Because of the high content of Ni release, it could be determined by diluting the extraction medium, and other extraction media could be determined directly. Ni release standard curves were plotted by the release amount and different time point variables. Though the different extraction media Ni release curves confirm the specificity of extraction media instead of blood.Results:By analyzing the Ni release curves of seven leaching media, it was found that none of these seven extraction media was suitable for the evaluation of Ni release in in vitro leaching media. Considering the safety of the leaching medium and the simplicity of preparation, hydrochloric acid solution was chosen as the leaching medium, but the concentration needed to be diluted accordingly. Finally, a hydrochloric acid solution was created as an alternative to blood for the in vitro study of Ni release from Ni-Ti alloy cardiovascular products, with a volume fraction of 0.005%. Conclusions:The in vitro leaching medium that can replace blood was found to be hydrochloric acid for the time being, but its concentration was too high, resulting in too much Ni release as well, which deviated from the actual situation. Therefore, the hydrochloric acid solution was diluted step by step, and the Ni release curve was examined until it was close to the clinical release level, and the actual concentration was determined, thus laying a solid foundation for the subsequent evaluation of the safety and risk.
8.Contralateral endoscopic approach for lumbar foraminal stenosis using unilateral biportal endoscopic surgery
Wei CHENG ; Rong-Xue SHAO ; Cheng-Yue ZHU ; Dong WANG ; Wei ZHANG ; Hao PAN
China Journal of Orthopaedics and Traumatology 2024;37(4):331-337
Objective To assess the feasibility and imaging outcomes of unilateral biportal endoscopic technique in the treatment of lumbar foraminal stenosis through contralateral approach.Methods The clinical data of 33 patients with lumbar foraminal stenosis treated with unilateral biportal endoscopic technique from January 2021 to July 2022 were retrospectively analyzed.There were 17 males and 16 females;age ranging from 34 to 72 years old with an average of(56.00±7.89)years old;operation time and perioperative complications were recorded;visual analogue scale(VAS)of pain was recorded,to evaluate the degree of low back pain and lower extremity pain,and Oswestry disability index(ODI)to evaluate the lumbar spine func-tion.At the latest follow-up,the modified Macnab score was used to evaluate the clinical efficacy.Results All patients success-fully completed the operation.The operation time ranged from 47 to 65 minutes,with an average of(56.10±5.19)minutes.The postoperative follow-up ranged from 12 to 18 months,with an average of(14.9±2.3)months.The VAS of low back and lower extermity pain before operation were(7.273±1.442)and(7.697±1.447)scores,ODI was(69.182±9.740)%.Postoperative lumbocrural pain VAS were(3.394±0.966)and(2.818±0.727)scores,ODI was(17.30±4.78)%.At the latest follow-up,VAS of back and lower extermity pain was(2.788±0.650)and(2.394±0.704)scores,ODI was(14.33±350)%.There were signifi-cant differences in VAS of low back and lower extremity pain and ODI before and after operation(P<0.05).At the latest follow-up,according to the modified Macnab criteria,24 patients got excellent result,5 as good,2 as fair,and 2 as poor.Conclusion Unilateral biportal endoscopic treatment of lumbar foraminal stenosis through the contralateral approach is a safe and efficient method,with few complications,quick postoperative recovery,and satisfactory clinical outcomes.During the follow-up period,no iatrogenic lumbar instability was observed.
9.AI-HIP system for prosthesis size,global femoral offset and osteotomy in total hip arthroplasty
Guo-Yuan SUN ; Yan-Kun JIANG ; Tong LI ; Xue-Feng CONG ; Cheng HUANG ; Ran DING ; Wei-Guo WANG ; Qi-Dong ZHANG
China Journal of Orthopaedics and Traumatology 2024;37(9):848-854
Objective To explore planning effect of AI-HIP assisted surgical planning system in primary unilateral total hip arthroplasty(THA)and its influence on clinical outcomes.Methods A retrospective analysis was conducted on clinical data of 36 patients who underwent their first unilateral THA from March 2022 to November 2022 and continuously used AI-HIP system(AI-HIP group),including 16 males and 20 females,aged from 43 to 81 years old with an average of(62.2±10.9)years old.According to the matching principle,36 patients who were planned by the traditional template method at the same period were selected as the control group,including 16 males and 20 females,aged from 40 to 80 years old with an average of(60.9±12.1)years old.The accuracy between two groups of prostheses were compared,as well as the combined eccentricity difference between preoperative planning and postoperative practice,lower limb length difference,osteotomy height from the upper edge of the lesser trochanter and top shoulder distance to evaluate planning effect.Harris score and visual analogue scale(VAS)were used to evaluate clinical efficacy.Results Both groups were followed up for 12 to 18 months with an average of(14.5±2.1)months.The complete accuracy and approximate accuracy of acetabular cup and femoral stalk prosthesis in AI-HIP group were 72.2%,100%,58.3%,88.9%,respectively,which were better than 44.4%,83.3%,33.3%,66.7%in control group(P<0.05).There was no statistical significance in planning of femoral head prosthesis size(P>0.05).The actual combined eccentricity difference and combined eccentricity difference(practical-planning)in Al-HIP group were 1.0(0.2,2.4)mm and 1.1(-2.1,3.2)mm,respectively;which were better than 3.0(1.4,4.9)mm and 3.5(-1.6,6.5)mm in control group(P<0.05).There was no significant difference between two groups in actual osteotomy height of the upper margin of the lesser trochanter(P>0.05).In AI-HIP group,the actual difference of lower extremity length after surgery,the difference of lower extremity length(practical-planning),osteotomy height from the upper margin of lesser trochanter(practical-planning),actual topshoulder distance after surgery,and topshoulder distance(practical-planning)were 1.5(0.2,2.8),1.1(-0.3,2.2),2.1(-2.3,4.1),(15.3±4.1),2.2(-4.8,0.3)mm,respectively;which were better than control group of 2.6(1.3,4.1),2.5(0.3,3.8),5.8(-2.4,7.7),(13.0±4.3),-5.7(-9.4,-2.2)mm(P<0.05).At final follow-up,there were no significant differences in Harris scores of pain,function,deformity,total scores and VAS between two groups(P>0.05).The range of motion score was 4.8±0.6 in AI-HIP group,which was higher than that in control group(4.4±0.8)(P<0.05).Conclusion Compared with traditional template planning,AI-HIP assisted surgical planning system has good accuracy in predicting the prosthetic size of the acetabular cup and femoral stalk,restor-ing joint eccentricity,planning lower limb length,osteotomy height and top shoulder distance on the first unilateral THA,and the clinical follow-up effect is satisfactory.
10.D-shant atrial shunt device implantable in patients with severe pulmonary hypertension and right heart failure:one case report and literature review
Shu-Na XIAO ; Wen-Jie GAO ; Xiao-Ke SHANG ; Chang-Dong ZHANG ; Yu-Cheng ZHONG ; Ying ZHI ; Lin-Li QIU ; Yan-Fei DONG ; Yan HE ; Wei TIAN ; Wen-Wen TANG
Chinese Journal of Interventional Cardiology 2024;32(8):472-477
To evaluate the effectiveness and safety of implantable D-shant atrial shunt device in patients with severe pulmonary arterial hypertension(PAH)and right heart failure.A 53-year-old female patient diagnosed with severe idiopathic PAH and right heart failure,her WHO FC grade was Ⅳ.The right heart catheter and implantation of D-shant atrial shunt device were performed under local anesthesia on November 30,2021.A 6 mm×4 cm peripheral artery balloon was selected to dilate the atrial septum and a D-shant atrial shunt device with a fixed 4 mm diameter orifice was implanted into the heart.The clinical symptoms and hemodynamics of the patient was improved after the intervention.Implantation of atrial shunt device as a palliative therapy to established a right to left shunt is another strategy for treating patients with severe PAH in late period,which has good effectiveness and safety.It could be the last replacement therapy to improve symptoms and prolonged lives to drug resistant and severe PAH patients.


Result Analysis
Print
Save
E-mail