1.Study on the correlation between cardiac implantable electronic device electrode leads and tricuspid regurgitation
Yu-yang JIN ; Jian-hua WANG ; Jian XU ; Shu-feng LI ; Wei CAO
Chinese Journal of Interventional Cardiology 2025;33(3):141-149
Objective To investigate the effect of operation mode,thickness,and number of implanted electrode leads on tricuspid regurgitation.Methods This was a single-center retrospective study.Patients who received their first cardiac implantable electronic device at the Second Affiliated Hospital of Harbin Medical University from January 2019 to January 2024 and were followed up within(10±4)months were continuously enrolled.General clinical data,preoperative and outpatient follow-up echocardiography,and other indicators were collected.According to the different operation modes,patients were divided into delivery sheath group,support wire group,and delivery sheath combined support wire group.Under the premise of only one electrode wire crossing the tricuspid valve,according to the different thicknesses of the electrode wire,they were divided into 3830 69 group(4.1 F),5076 58/Solia S60 group(7 F),and 6935M-65cm defibrillator group(9 F).The number of electrode wires was divided into 3830 69 subgroup and 6935M-65cm defibrillator subgroup under the premise of balanced operation mode and electrode material.The changes in tricuspid valve regurgitation were compared in each group.Results A total of 219 patients,aged(65.92±12.04)years,were enrolled.There was no difference in tricuspid valve regurgitation in the 6935M-65cm defibrillator subgroup before implantation(all P>0.05).In the 3830 69 subgroup,there was a higher proportion of severe regurgitation in the two-electrode group before implantation(P=0.013).In comparison with the change in tricuspid valve regurgitation before electrode wire implantation and during follow-up,the regurgitation of the tricuspid valve in the 6935M-65cm defibrillator subgroup with≥2 electrodes was unexpectedly improved compared to that in the group with one electrode,and the regurgitation of the valve in the group with one electrode was more severe than that in the group with ≥ 2 electrodes implantation(P=0.019).Conclusions The operation mode and thickness of the implanted electrode lead did not cause significant differences in tricuspid valve regurgitation.Single implantation of a 6935M-65cm defibrillator electrode will lead to increased tricuspid regurgitation,and the effect brought by combination with physiological pacing will offset the adverse effects of electrode leads on the valve,providing directional evidence for future implantation strategy selection.
2.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]
3.Maintenance of Bausch&Lomb BL11110 phacoemulsification system:Three case reports
An-hai WEI ; Rui NIE ; Li-dong FAN ; Ke-xin PAN ; Zhen-zhen CAO ; Qing-hui REN ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(4):118-120
The working principle of Bausch&Lomb BL11110 phacoemulsification system was described.Three cases of typical faults of the phacoemulsification system were introduced,and the causes were analyzed,then the maintenance measures were given accordingly.References were provided for diagnosing and eliminating the faults of the phacoemulsification system.[Chinese Medical Equipment Journal,2025,46(4):118-120]
4.Application of biomechanical simulation based on three-dimensional human body model in preventing pressure ulcers:a scoping review
Lingxiao RAN ; Dongmin WANG ; Ke XU ; Cong WANG ; Hua CAO ; Wei CUN ; Yan JIANG
Chinese Journal of Nursing 2025;60(8):1012-1018
Objective A scoping review of domestically and internationally published studies on finite element analysis(FEA)based on three-dimensional(3D)human body model in preventing pressure ulcer(PU)was conducted,aiming to provide new directions for improving the prevention strategies of pressure ulcer.Methods We conducted a systematic search in both Chinese and English medical databases,including PubMed,Embase,CINAHL,Web of Science,Cochrane Library,Sinomed,CNKI,Wanfang and VIP,and engineering database(Engineering Village Compen-dex).The search period was from the inception of each database to July 29,2024.The information was extracted,and the results were analyzed and standardized for reporting.Results A total of 30 studies were included.The general methods of FEA based on 3D human body model include establishing geometric model,meshing,defining material properties,loading and setting boundary conditions,and solving equations.According to the contents of studies,they could be categorized into 4 distinct application domains,including identification of risk groups(n=9),position management(n=9),preventive dressings(n=10)and supportive surfaces(n=7).Conclusion FEA based on 3D human body model provides a foundation to PU biomechanical mechanism research and a scientific basis to the supplement and optimization of clinical prevention.Future studies should integrate clinical problems with simulations and further optimize simulations techniques and protocols.
5.The clinical value of NHR combined with MLR for predicting early rebleeding after endoscopic treatment in patients with cirrhosis complicated by acute esophageal-gastric variceal rupture and bleeding
Yan LI ; Haitao JIAO ; Haiyang HUA ; Wei LIU ; Shuling LIU ; Xinju CAO ; Xin HAO ; Aimin WANG
Tianjin Medical Journal 2025;53(11):1152-1157
Objective To evaluate the predictive value of neutrophil/high-density lipoprotein cholesterol ratio(NHR)combined with monocyte/lymphocyte ratio(MLR)for early rebleeding after endoscopic treatment in patients with cirrhosis complicated by acute esophagogastric variceal bleeding(AEVB).Methods A total of 228 patients with cirrhosis complicated by AEVB were included in this study.According to the occurrence of early rebleeding,patients were divided into the rebleeding group(96 cases)and the non-rebleeding group(132 cases).General information and laboratory indicators of both groups were collected,and the End-Stage Liver Disease(MELD)score,Child-Turcotte-Pugh(CTP)score,Fibrosis-4(FIB-4)index,NHR,and MLR were calculated.Logistic regression analysis was used to identify the risk factors for early rebleeding in patients with cirrhosis complicated by AEVB.A nomogram model based on NHR and MLR was constructed to predict the risk of early rebleeding.The predictive performance and goodness of fit of the model were evaluated using receiver operating characteristic(ROC)curve,Hosmer-Lemeshow test,Net Reclassification Index(NRI)and Integrated Discrimination Improvement(IDI).Results Compared with the non-rebleeding group,systolic blood pressure,platelet count(PLT),albumin/globulin ratio(A/G)and low-density lipoprotein cholesterol(LDL-C)were decreased in the rebleeding group,while total bile acids(TBA),aspartate aminotransferase(AST),alanine aminotransferase(ALT),total bilirubin(TBIL),activated partial thromboplastin time(APTT),thrombin time(TT),international normalized ratio(INR),Fibrosis-4(FIB-4),NHR,MLR,MELD score and CTP score were increased(P<0.05).NHR was positively correlated with AST,TBIL and INR(P<0.05).MLR was negatively correlated with PLT,and positively correlated with AST,TBIL and FIB-4(P<0.05).Logistic regression analysis results showed that prolonged TT,elevated NHR and MLR were independent risk factors for early rebleeding in patients with cirrhosis complicated by AEVB.The nomogram model based on NHR and MLR to predict early rebleeding had an area under the curve of 0.810(95%CI:0.754-0.866).The Hosmer-Lemeshow test suggested that the model fit well.IDI and NRI analyse showed that the combination of NHR and MLR had better predictive value for the early rebleeding than that of MELD score and CTP score.Conclusion NHR and MLR are effective indicators for predicting early rebleeding after endoscopic treatment in patients with cirrhosis complicated by AEVB.They are helpful in the early identification of high-risk patients and provide a reference for clinical intervention.
6.Study on the correlation between cardiac implantable electronic device electrode leads and tricuspid regurgitation
Yu-yang JIN ; Jian-hua WANG ; Jian XU ; Shu-feng LI ; Wei CAO
Chinese Journal of Interventional Cardiology 2025;33(3):141-149
Objective To investigate the effect of operation mode,thickness,and number of implanted electrode leads on tricuspid regurgitation.Methods This was a single-center retrospective study.Patients who received their first cardiac implantable electronic device at the Second Affiliated Hospital of Harbin Medical University from January 2019 to January 2024 and were followed up within(10±4)months were continuously enrolled.General clinical data,preoperative and outpatient follow-up echocardiography,and other indicators were collected.According to the different operation modes,patients were divided into delivery sheath group,support wire group,and delivery sheath combined support wire group.Under the premise of only one electrode wire crossing the tricuspid valve,according to the different thicknesses of the electrode wire,they were divided into 3830 69 group(4.1 F),5076 58/Solia S60 group(7 F),and 6935M-65cm defibrillator group(9 F).The number of electrode wires was divided into 3830 69 subgroup and 6935M-65cm defibrillator subgroup under the premise of balanced operation mode and electrode material.The changes in tricuspid valve regurgitation were compared in each group.Results A total of 219 patients,aged(65.92±12.04)years,were enrolled.There was no difference in tricuspid valve regurgitation in the 6935M-65cm defibrillator subgroup before implantation(all P>0.05).In the 3830 69 subgroup,there was a higher proportion of severe regurgitation in the two-electrode group before implantation(P=0.013).In comparison with the change in tricuspid valve regurgitation before electrode wire implantation and during follow-up,the regurgitation of the tricuspid valve in the 6935M-65cm defibrillator subgroup with≥2 electrodes was unexpectedly improved compared to that in the group with one electrode,and the regurgitation of the valve in the group with one electrode was more severe than that in the group with ≥ 2 electrodes implantation(P=0.019).Conclusions The operation mode and thickness of the implanted electrode lead did not cause significant differences in tricuspid valve regurgitation.Single implantation of a 6935M-65cm defibrillator electrode will lead to increased tricuspid regurgitation,and the effect brought by combination with physiological pacing will offset the adverse effects of electrode leads on the valve,providing directional evidence for future implantation strategy selection.
7.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]
8.Maintenance of Bausch&Lomb BL11110 phacoemulsification system:Three case reports
An-hai WEI ; Rui NIE ; Li-dong FAN ; Ke-xin PAN ; Zhen-zhen CAO ; Qing-hui REN ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(4):118-120
The working principle of Bausch&Lomb BL11110 phacoemulsification system was described.Three cases of typical faults of the phacoemulsification system were introduced,and the causes were analyzed,then the maintenance measures were given accordingly.References were provided for diagnosing and eliminating the faults of the phacoemulsification system.[Chinese Medical Equipment Journal,2025,46(4):118-120]
9.The clinical value of NHR combined with MLR for predicting early rebleeding after endoscopic treatment in patients with cirrhosis complicated by acute esophageal-gastric variceal rupture and bleeding
Yan LI ; Haitao JIAO ; Haiyang HUA ; Wei LIU ; Shuling LIU ; Xinju CAO ; Xin HAO ; Aimin WANG
Tianjin Medical Journal 2025;53(11):1152-1157
Objective To evaluate the predictive value of neutrophil/high-density lipoprotein cholesterol ratio(NHR)combined with monocyte/lymphocyte ratio(MLR)for early rebleeding after endoscopic treatment in patients with cirrhosis complicated by acute esophagogastric variceal bleeding(AEVB).Methods A total of 228 patients with cirrhosis complicated by AEVB were included in this study.According to the occurrence of early rebleeding,patients were divided into the rebleeding group(96 cases)and the non-rebleeding group(132 cases).General information and laboratory indicators of both groups were collected,and the End-Stage Liver Disease(MELD)score,Child-Turcotte-Pugh(CTP)score,Fibrosis-4(FIB-4)index,NHR,and MLR were calculated.Logistic regression analysis was used to identify the risk factors for early rebleeding in patients with cirrhosis complicated by AEVB.A nomogram model based on NHR and MLR was constructed to predict the risk of early rebleeding.The predictive performance and goodness of fit of the model were evaluated using receiver operating characteristic(ROC)curve,Hosmer-Lemeshow test,Net Reclassification Index(NRI)and Integrated Discrimination Improvement(IDI).Results Compared with the non-rebleeding group,systolic blood pressure,platelet count(PLT),albumin/globulin ratio(A/G)and low-density lipoprotein cholesterol(LDL-C)were decreased in the rebleeding group,while total bile acids(TBA),aspartate aminotransferase(AST),alanine aminotransferase(ALT),total bilirubin(TBIL),activated partial thromboplastin time(APTT),thrombin time(TT),international normalized ratio(INR),Fibrosis-4(FIB-4),NHR,MLR,MELD score and CTP score were increased(P<0.05).NHR was positively correlated with AST,TBIL and INR(P<0.05).MLR was negatively correlated with PLT,and positively correlated with AST,TBIL and FIB-4(P<0.05).Logistic regression analysis results showed that prolonged TT,elevated NHR and MLR were independent risk factors for early rebleeding in patients with cirrhosis complicated by AEVB.The nomogram model based on NHR and MLR to predict early rebleeding had an area under the curve of 0.810(95%CI:0.754-0.866).The Hosmer-Lemeshow test suggested that the model fit well.IDI and NRI analyse showed that the combination of NHR and MLR had better predictive value for the early rebleeding than that of MELD score and CTP score.Conclusion NHR and MLR are effective indicators for predicting early rebleeding after endoscopic treatment in patients with cirrhosis complicated by AEVB.They are helpful in the early identification of high-risk patients and provide a reference for clinical intervention.
10.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.