1.Pathological changes and macrophage polarization in the liver and spleen of mice infected with Angiostrongylus cantonensis
Xiaoyu QIN ; Yuchun CAI ; Yang HONG ; Fanna WEI ; Yahong HU ; Yumeng CAI ; Yuan HU ; Ting ZHANG ; Xiaojin MO ; Bin XU ; Yan LU ; Jiahui SUN ; Yan ZHOU ; Zelin ZHU ; Muxin CHEN
Chinese Journal of Schistosomiasis Control 2026;38(2):169-183
Objective To investigate the temporal changes in pathological damage and macrophage polarization in liver and spleen tissues of mice infected with Angiostrongylus cantonensis, and to preliminarily unravel the peripheral immune responses during the early stage of A. cantonensis infection. Methods Forty female BALB/c mice at ages of 6 to 8 weeks were randomly divided into four groups, including the control group and 7-, 14-, and 21-day infection groups, with 10 mice in each group. Each mouse in the infection groups was inoculated with 30 third-stage (L3) larvae of A. cantonensis by oral gavage, and five mice were randomly selected from each infection group on days 7, 14, and 21 post-infection, while mice in the control group were given the same volume of physiological saline and five mice were randomly selected from the control group on the day of oral gavage. Mouse liver and spleen tissues were sampled. The histopathological changes of mouse liver and spleen tissues were observed using hematoxylin and eosin (HE) staining, and the percentage of positive staining area and the co-localization positive rates of the macrophage surface antigens F4/80, CD86, and CD206 were quantified in mouse liver and spleen tissues using immunohistochemical and immunofluorescence staining. In addition, five mice were collected from each infection group on days 7, 14, and 21 post-infection, and five mice were collected from the control group on the day of oral gavage. Mouse liver and spleen tissues were sampled for detection of macrophage markers CD86 and CD206 and macrophage phenotyping using flow cytometry, and the expression of M1 macrophage markers, including inducible nitric oxide synthase (Nos2), tumor necrosis factor-α (TNF-α), interleukin-1β (IL-1β) and M2 markers, including arginase 1 (Arg1), mannose receptor C-type 1 (Mrc1) and chitinase-like protein 3 (Chil3) was quantified in mouse liver and spleen tissues using real-time quantitative PCR (RT-qPCR) assay. Results Proliferative lesions of the hepatocyte were observed in mouse liver tissues and the follicular structures of the mouse spleen white pulp were disrupted 21 days post-infection with A. cantonensis. Immunohistochemical staining showed that there were significant differences in the percentages of F4/80, CD86 and CD206 positive staining areas in the liver and spleen tissues among the four groups of mice (F = 242.40, 197.14, 183.19, 157.65, 242.35 and 146.24; all P values < 0.001), and the percentages of positive staining in the liver and spleen tissues of mice in the 14-day infection group [(4.45 ± 0.51)%, (3.74 ± 0.67)%, (8.32 ± 0.72)%, (16.56 ± 1.14)%, (11.62 ± 0.52)%, and (8.29 ± 0.72)%, respectively] and the 21-day infection group [(3.70 ± 0.11)%, (3.22 ± 0.43)%, (11.53 ± 1.03)%, (12.59 ± 1.05)%, (9.02 ± 0.83)%, and (11.67 ± 1.10)%, respectively] were higher than in the control group [(0.35 ± 0.16)%, (0.40 ± 0.02)%, (0.93 ± 0.05)%, (2.78 ± 0.26)%, (2.33 ± 0.20)%, and (1.85 ± 0.20)%, respectively] (all P values < 0.05). Immunofluorescence staining showed significant differences in the positive rates of F4/80 co-localization with CD86 and CD206 in mouse liver and spleen tissues among the four groups (F = 24.42, 25.28, 54.51 and 130.55; all P values < 0.001). Flow cytometry detected significant differences in the proportions of CD86+ and CD206+ macrophages in mouse liver and spleen tissues among the four groups (F = 67.98, 18.41, 29.77, 172.80; all P values < 0.001), and the proportions of CD206+ macrophages in the liver and spleen of the 21-day infection group were significantly higher than those in the control group [(9.25 ± 2.55)% vs (3.83 ± 0.72)%, and (4.22 ± 0.56)% vs (0.47 ± 0.18)%, respectively] (both P values < 0.05). In addition, RT-qPCR assay quantified significant differences in the relative mRNA expression of M1 macrophage markers (IL-1β, TNF-α and Nos2) and M2 macrophage markers (Arg1, Chil3 and Mrc1) in mouse liver and spleen tissues among the four groups (F = 41.30, 31.82, 199.33, 19.96, 62.01, 119.76, 23.67, 95.90, 72.27, 82.59, 123.41 and 29.75; all P values < 0.05). Conclusions A. cantonensis infection may cause progressive pathological damage in mouse liver and spleen tissues, accompanied by dynamic temporal changes in macrophage polarization. M1 macrophage polarization predominates at the early stage of A. cantonensis infection and shifts towards M2 polarization at the later stages, suggesting that M2 polarization may participate in immune regulation at late stages of A. cantonensis infection by suppressing excessive inflammatory responses and promoting tissue repair.
2.Human placental mesenchymal stem cell-derived exosomes carrying hsa-let-7i-5p mitigate lung injury in a murine model of aspiration pneumonia
Ching-Wei CHUANG ; Hong-Phuc Nguyen VO ; Yen-Hua HUANG ; I-Lin TSAI ; Chao-Yuan CHANG ; Chun-Jen HUANG
Korean Journal of Anesthesiology 2026;79(1):114-129
Background:
Aspiration pneumonia (AP), which can be caused by gastric content inhalation into the lower airways, causes acute lung injury (ALI) through complex mechanisms, including inflammation, oxidative stress, and apoptosis. Here, we evaluated the efficacy of exosomes derived from human placental mesenchymal stem cells (hpMSCs) in mitigating ALI in a murine model of AP. We also investigated the role of hsa-let-7i-5p, the most abundant miRNA in hpMSC-derived exosomes, in this respect.
Methods:
Adult male C57BL/6 mouse AP models were administered hpMSC-derived exosomes (APExo group) or phosphate-buffered saline (AP group) intra-tracheally. After 48 h, the mice were euthanized and evaluated. The effects of hsa-let-7i-5p were assessed by specific inhibition or overexpression.
Results:
Compared with the APExo group, the AP group exhibited significantly greater ALI, as evidenced by histological damage, increased lung injury scores, impaired lung function, increased leukocyte infiltration, and elevated tissue edema (all P < 0.05). The untreated AP group also showed more inflammation, characterized by nuclear factor-κB upregulation, macrophage M1 polarization, and cytokine level elevation (tumor necrosis factor-α, interleukin-1β, and interleukin-6), as well as increased oxidation and activation of the apoptosis pathway (all P < 0.05). Notably, the therapeutic effects of hpMSC-derived exosomes were compromised by specific inhibition of hsa-let-7i-5p. Furthermore, engineered exosomes derived from genetically modified RAW264.7 overexpressing hsa-let-7i-5p demonstrated therapeutic effects against AP similar to those obtained with hpMSC-derived exosomes.
Conclusions
In a murine AP model, intra-tracheal administration of hpMSC-derived exosomes has ALI-mitigating effects, involving inflammation, oxidation, and apoptosis modulation, with hsa-let-7i-5p playing a pivotal mediating role.
3.Application value of HASTE sequence based on deep learning in pancreatic T2WI
Da CAO ; Chuan-bing WANG ; Hong-yuan SHI ; Shao-wei HAO ; Qing LI
Chinese Medical Equipment Journal 2025;46(3):59-63
Objective To evaluate the clinical application value of the half-Fourier acquisition single-shot turbo spin echo(HASTE)sequence based on deep learning(DL)in pancreatic T2WI.Methods Data were collected from 41 patients who un-derwent both BLADE and DL-HASTE sequence scans during pancreatic T2WI at some hospital from February to July 2023.Qualitative assessments were made regarding overall image quality,pancreatic edge sharpness,pancreatic duct edge sharp-ness,pancreatic duct visua-lization(proximal,middle and distal segments)and lesion visibility of BLADE-sequence and DL-HASTE-sequence images.Quantitative assessments were carried out in terms of scan time,signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR).Statistical analyses were performed using SPSS 24.0.Results DL-HASTE sequence behaved significantly better than BLADE in pancreatic duct edge sharpness,pancreatic duct visualization,lesion visibility,scan time and CNR,while worse in pane-reatic edge sharpness(all P<0.05).There were significant differences between DL-HASTE and BLADE sequences in overall image quality and SNR(all P>0.05).Conclusion The DL-HASTE sequence maintains image quality while significantly shor-tening scan time,making it suitable for patients with irregular respiratory rates.[Chinese Medical Equipment Journal,2025,46(3):59-63]
4.Establishment of Cultural Method of Primary Rabbit Spinal Cord Microvascular Endothelial Cells
Hua-Gen MA ; Ming CHI ; Zhi-Yi LIN ; Yuan-Yu TANG ; Wei-Hong CONG
Chinese Journal of Biochemistry and Molecular Biology 2025;41(7):1062-1067
This study aims to isolate and culture primary rabbit spinal cord microvascular endothelial cells in vitro,providing a practical source of test cells for spinal cord injury research.Spinal cord tissue was aseptically extracted from one-month-old rabbits and processed sequentially through mincing,bovine serum albumin density gradient centrifugation,mesh filtration,and type Ⅱ collagenase digestion to ob-tain purified spinal cord microvascular segments.The microvascular segments were homogeneously mixed with an apprapriate volume of M199 complete culture medium and seeded into a culture dish for primary culture.Throughout the culture period,cell growth performance were continuously observed and recor-ded.Additionally,immunocytochemical staining was performed to evaluate the expression of factor Ⅷ-re-lated antigen.The results showed that after 24 hours of inoculation,a small amount of endothelial-like cells were observed to emerge from the spinal cord microvascular segments.Within 36~60 hours,the cell colonies gradually expanded and fused.After 72 hours,the cells spread across the base of the dish,forming a"cobblestone-like"monolayer.Immunocytochemical staining showed that more than 99%of the cells showed brown-red cytoplasm and were positive for factor Ⅷ-related antigen.It is these results that suggest this study has successfully established a convenient and stable primary rabbit spinal cord micro-vascular endothelial cells culture method.
5.Development and validation of a patient-specific quality assurance tool based on fast Monte Carlo and treatment log file in proton therapy
Hong-ying FENG ; Tian-yu PENG ; Jie SHAN ; Yong-hong ZHANG ; Bin-hang ZHANG ; Xian-bao YUAN ; Wei LIU
Fudan University Journal of Medical Sciences 2025;52(4):550-559
Objective To develop and validate a fast Monte Carlo(MC)-based patient-specific quality assurance(PSQA)tool using the treatment log files that is suitable to be used in the online adaptive radiotherapy for pencil beam scanning proton therapy(PBSPT-ART).Methods The proposed tool first used the delivery log file of a PBSPT plan to reversely reconstruct the PBSPT(rPBSPT)plan,and then used an in-house developed graphic processing unit(GPU)-accelerated virtual particle MC(VPMC)dose engine to calculate the dose distribution of the rPBSPT plan.The rPBSPT dose calculated by VPMC was then compared to the rPBSPT dose calculated by another independent MC dose engine(MCsquare),using 3D gamma analysis to verify the accuracy of VPMC calculation.As a demonstration of the feasibility of developed log file-based PSQA,the VPMC calculated dose of the rPBSPT plan was compared to the pre-delivery second check dose of the corresponding PBSPT plan calculated by MCsquare,using 3D gamma analysis.3D gamma analysis employes a criterion of 2 mm/2%/10%.Twenty patients with different disease sites were representatively selected to validate the efficiency and accuracy of the tool.Results The average calculation time of a rPBSPT plan by VPMC was(5.88±4.00)s in the accuracy verification.Compared to MCsquare,the passing rate of the 3D gamma analysis was 99.47%±0.72%.In the proposed PSQA tool demonstration,the passing rate of comparing the VPMC calculated rPBSPT dose to MCsquare calculated second check dose of the corresponding PBSPT plan was 98.91%±0.92%.Conclusion The accuracy and efficiency of the tool can meet the requirements of PSQA in the online PBSPT-ART workflow.
6.Construction of medical consumables selection indicator system based on analytic hierarchy process and fuzzy cluster method
Li-ping FAN ; Miao XIAO ; Guo-zhong LU ; Wei WANG ; Yu-yuan DENG ; Zhi-hong CHEN
Chinese Medical Equipment Journal 2025;46(11):78-83
Objective To construct a medical consumables selection indicator system based on analytic hierarchy process(AHP)and fuzzy cluster method.Methods Firstly,a medical consumables selection indicator system was established preliminarily with the literature research results and actual situation of hospital consumables management;secondly,13 experts in related fields were selected to execute two rounds of online questionnaires,the expert weights were determined with AHP,the importance of each selection indicator was scored by the expert evaluation method and fuzzy cluster method,and consistency analysis was carried out on the two rounds of expert evaluation results;finally,the final medical consumables selection indicator system was built with the 100-point scale.Results The constructed medical consumables selection indicator system was composed of 5 primary indicators,12 secondary indicators and 38 tertiary indicators.The primary indicators included consumables quality,clinical demand,cost-effectiveness,supply capacity and after-sales service,with the percentage-based scores being 27,25,14,26 and 8,respectively.Conclusion The medical consumables selection indicator system based on AHP and fuzzy cluster method with high reliability provides effective and reliable references for medical institutions to select medical consumables.
7.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
8.Ameliorative effects of Compound Fufangteng Mixture on cyclophosphamide-induced immunosuppression in mice
Li-na LIU ; Yu-fang SHEN ; Qin-qin WANG ; Lin-yu XIAO ; Jing-yu LIU ; Jun-ni MO ; Ren-yi-kun YUAN ; Hong-wei GAO ; Jian XIAO
Chinese Traditional Patent Medicine 2025;47(10):3249-3256
AIM To investigate the ameliorative effects of Compound Fufangteng Mixture(CFM)on cyclophosphamide(CTX)-induced immunosuppression in mice.METHODS Forty-eight male C57BL/6J mice were randomly divided into the blank control group,the model group,the levamisole hydrochloride group(40 mg/kg)and the low-dose,medium-dose and high-dose CFM groups(3.75,7.5,10 g/kg),with 8 mice in each group,and given respective intervention orally once daily for 14 days.On the 5th to 7th day of administration,with the blank control group given normal saline intraperitoneally,the other groups underwent intraperitoneal CTX injections(80 mg/kg).24 hours after the last administration,organ indices of thymus and spleen were calculated;splenic histopathological alterations were assessed by HE staining;serum levels of IL-2,IL-6 and IgG were quantified using ELISA;splenic CD4+,CD8+T lymphocytes,alongside CD86+and CD206+macrophages populations were analyzed by flow cytometry;and splenic expression of CD4,CD8 and F4/80 was evaluated by immunohistochemical staining.RESULTS In CTX-treated mice,CFM administration mitigated body weight loss;enhanced thymus weight and thymic index;ameliorated splenic immune cell populations,elevated serum levels of cytokines IL-2,IL-6 and IgG in serum;and upregulated splenic levels of CD45+CD3+T lymphocytes and F4/80+CD11b+macrophages,alongside increasing the expression of CD4,CD8 and F4/80 surface markers.CONCLUSION CFM alleviates CTX-induced immunosuppression state in mice by modulating immune cells,restoring immune function and enhancing anti-inflammatory and tissue repair capabilities.
9.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
10.Design of 8-channel gene analyzer
Shi-hong MA ; Yu QIAN ; Song LIANG ; Xia-bin LI ; Jing-jing ZHANG ; Yuan ZHAO ; Wei WANG ; Jian-rong CAO
Chinese Medical Equipment Journal 2025;46(2):24-30
Objective To design an 8-channel gene analyzer to take the place of the widely used gene analyzer with problems in inconvenient consumable replacement and short storage time of electrophoresis polymer.Methods The 8-channel gene analyzer had its mechanical components composed of an automatic sample loading table,a polymer injection module,a high-voltage temperature control module,an optical module and an integrated U box,its electrical control system made up of a host computer(an embedded computer)and three slave computers(a sampling control board,a polymer injection control board and a high-voltage temperature control board).The automatic sample loading table involved in four motors and transmission systems for x,y,z directions and optical alignment,the transmission systems adopted mainly belt drive mode and the optical alignment motor had its threads with an anti-backlash structure;the polymer injuection module was manipulated by the polymer injection control board,and the polymer block was made of highly transparent acrylic material;the high-voltage temperature control module realized the regulation of electrophoresis voltage and the detection of electrophoresis current by the low-ripple precision high-voltage power supply,and controlled the temperature of the heating furnace by the proportional-integral-differential(PID)algorithm;the optical module consisted of an excitation module and a light-receiving module,which had the base of the reflector made of low expansion coefficient alloy material;the integrated U box had the electrophoresis polymer,capillary array,polymer block and anode buffer in a plastic housing;the host computer had the data acquisition software programmed with C# and C++,and the slave computers were controlled by STM32 SCM.Results The 8-channel gene analyzer had no significant differences with the widely used ABI3500 gene analyzer in resolution,precision accuracy and clinical results.Conclusion The 8-channel gene analyzer gains advantages in consumable replacement and storage time of electrophoresis polymer,and can meet the requirements for gene sequencing.[Chinese Medical Equipment Journal,2025,46(2):24-30]