1.A new glycoside from Alstonia mairei Lévl.
Li-ke WANG ; Bing-yan LI ; Zhen-zhu ZHAO ; Yan-zhi WANG ; Xiao-kun LI ; Wei-sheng FENG ; Ying-ying SI
Acta Pharmaceutica Sinica 2025;60(1):191-195
Nine compounds were isolated and purified from 90% ethanol extract of
2.Comparison of the efficacy of TiRobot orthopaedic robot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures
Xing-Long ZHAO ; Jian-Jun SHEN ; Kang-Hu FENG ; Zhi-Wei CHEN ; Yuan-Long SI ; Xuan ZHANG ; Guan-De WANG ; Xiang HAI
China Journal of Orthopaedics and Traumatology 2024;37(2):129-134
Objective To compare the effectiveness of TiRobot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures.Methods A retrospective analysis was conducted on 72 patients with unstable femoral neck fractures who were treated with percutaneous cannulated screw fixation assisted with TiRobot Orthopaedic robot from December 2019 to April 2021.Among them,37 patients were treated with F screw internal fixa-tion,including 16 males and 21 females,aged47 to 64years old with an average of(53.87±5.28)years old;According to Pauwels classification,there were 1 case of type Ⅰ,19 cases of type Ⅱ,17 cases of type Ⅲ;8 cases of combined medical diseases;17 cases of falling,8 cases of traffic accident and 12 cases of falling from height;The time from injury to operation was 29 to 49 hours with average of(35.00±7.34)hours.Another 35 cases used internal fixation with an inverted triangle parallel nail,including 13 males and 22 females with an average age of 46 to 63 years old(52.36±5.05)years old;According to the Pauwels injury classifi-cation:there were 2 cases of type Ⅰ,21 cases of type Ⅱ,12 cases of type Ⅲ;6 cases of medical diseases,15 cases of falling in-jury,9 cases of traffic accident,11 cases of falling injury;The time from injury to operation was 30 to 45 hours with an average of(33.00±6.83)h.The intraoperative blood loss,operation time,intraoperative fluoroscopy times,follow-up time,fracture healing time,postoperative complications were observed and compared between the two groups.The hip joint function was e-valuated by Harris score at 6 months and 12 months after operation.Results There was no significant difference in operation time,intraoperative blood loss,intraoperative fluoroscopy times and other intraoperative data between two groups(P>0.05).Both groups were followed up regularly,and the follow-up time was 12 to 16 months.The fracture healing time and Harris score of the F screw internal fixation group were better than those of the inverted triangle parallel nail internal fixation group(P<0.05).There was 1 case of femoral neck shortening in the F screw internal fixation group,1 case of nonunion,1 case of nail withdrawal,and 1 case of lower extremity deep vein thrombosis in the inverted triangle internal fixation group.The incidence of complications in the F screw internal fixation group was lower than that in the inverted triangle parallel nail internal fixation group(P<0.05).Conclusion Percutaneous cannulated F screw technique using Tirobot navigation positioning system is a safe and effective treatment for patients with unstable femoral neck fractures.It can significantly shorten the fracture healing time,reduce the incidence of postoperative complications,significantly improve hip joint function,and improve the quality of life.
3.Application of metal cushion block combined with Jumbo cup in reconstruction of acetabular bone defect in revision of artificial hip joint
Feng-Zhen LI ; Wen-Teng SI ; Ai-Li TIAN ; Yu ZHOU ; Ming-Wei CHEN
China Journal of Orthopaedics and Traumatology 2024;37(5):464-469
Objective To investigate the application effect and imaging changes of metal cushion block combined with Jumbo cup in the reconstruction of acetabular bone defect after revision of artificial hip joint.Methods Retrospective analysis was made on the clinical data of 83 patients who underwent revision acetabular bone defect reconstruction of the artificial hip joint in our hospital from September 2019 to October 2021.They were divided into group A and group B according to different surgical methods.There were 42 patients in group A,including 26 males and 16 females,aged from 44 to 72 years old with an average of(60.57±4.62)years,who underwent revision with metal cushion block and Jumbo cup.There were 41 patients in group B,including 22 males and 19 females,aged from 42 to 71 years old with an average of(58.74±4.25)years,who under-went revision with metal cushion block and bone cement mortar cup.The operation related indexes,Harris hip function score and visual analogue scale(VAS)of pain before operation,1 month and 12 month after operation were compared between two groups.The results of X-ray imaging examination(hip rotation center height,acetabular abduction angle,femoral eccentricity and imaging standard qualification rate)before and 12 month after operation were evaluated,and the incidence of complica-tions was compared between two groups.Results There was no significant difference in operation time,intraoperative bleeding volume and postoperative drainage volume between two groups(P>0.05).Both groups were followed up for 12 to 36 months with an average of(25.36±3.59)months.The scores of pain,function,deformity and Harris'total score in the two groups at 1 month after operation were higher than those before operation(P<0.05),and the scores of pain,function,deformity,joint activ-ity and Harris'total score in two groups at 1 year after operation were higher than those before operation and 1 month after op-eration(P<0.05),and the above scores in group A were higher than those in group B at 1 year after operation(P<0.05).The VAS of two groups decreased successively at 1 month and 1 year after operation(P<0.05),but there was no significant differ-ence in both groups at each time point(P>0.05).The femoral eccentricity increased in both groups at 1 year after operation(P<0.05),and group A was higher than group B(P<0.05).The height of rotation center and acetabular abduction angle de-creased in both groups at 1 year after operation(P<0.05),and the height of rotation center in group A was lower than that in group B(P<0.05),but there was no significant difference in acetabular abduction angle between two groups(P>0.05).The imaging qualification rate of group A was higher than that of group B(P<0.05).There was no significant difference in the inci-dence of adverse reactions between two groups(P>0.05).Conclusion Metal cushion block combined with Jumbo cup in the treatment of acetabular bone defects can provide the hip joint function,and restore the hip joint rotation center,femoral eccen-tricity and acetabular abduction angle,with obvious clinical effect.
4.Research on robot-based surgical instrument detection and pose estimation algorithm with multi-cascade deep learning processor
Si-Qi HAN ; Min-Kui CHEN ; Li-Pu WEI ; Qian RAN ; Qian XU ; Ming YU ; Yu-Chao SUN ; Feng CHEN
Chinese Medical Equipment Journal 2024;45(6):1-8
Objective To propose a multi-cascade deep learning processor-based surgical instrument detection and pose estimation algorithm to facilitate the robotic scurb nurse to recognize and delivery surgical instruments.Methods The proposed multi-cascade deep leaning processor-based CYSP algorithm was hibernated with several functional modules such as YOLOX with coordinate attention block(CA-YOLOX),segment anything model(SAM)and principal component analysis(PCA).Firstly,CA-YOLOX was applied to identifying the types of the surgical instruments and completing the coarse positioning of x and y coordinates;secondly,the SAM segmenter was used to clarify the positions of the instruments in the RGB image,and the depth information and internal parameters of the camera were introduced to obtain the point cloud of the surgical instruments;finally,the center of mass,principal direction and normal direction of the surgical instrument point cloud were determined through the PCA algorithm,with which the rotation and translation(RT)matrix between the target coordinate system(surgical instrument center of mass coordinate system)and the base coordinate system of the robotic arm was solved,and the matrix was converted into a quaternion and then transmitted to the robotic arm control unit so as to drive the robotic arm to arrive at the corresponding position and pick up the instrument to complete the instrument delivery task.Migration training was accomplished on a self-constructed surgical instrument image dataset and the effectiveness of the proposed algorithm was evaluated,and instrument delivery experiments were performed on a seven-degree-of-freedom robotic arm and the success rate of the algorithm was assessed.Results The multi-cascade deep leaning processor-based CYSP algorithm had a recognition accuracy of 98.52%on the surgical instrument dataset,a success rate of 94%for the in-strument delivery experiment and average time for recognition of 0.28 s.Conclusion The multi-cascade deep leaning proces-sor-based CYSP algorithm with high reliability and practicability behaves well in facilitating the robotic scurb nurse to recog-nize and deliver surgical instruments.[Chinese Medical Equipment Journal,2024,45(6):1-8]
5.A new suberin from roots of Ephedra sinica Stapf
Bo-wen ZHANG ; Meng LI ; Xiao-lan WANG ; Ying YANG ; Shi-qi ZHOU ; Si-qi TAO ; Meng YANG ; Deng-hui ZHU ; Ya-tong XU ; Wei-sheng FENG ; Xiao-ke ZHENG
Acta Pharmaceutica Sinica 2024;59(3):661-666
Six compounds were isolated from the roots of
6.Two new dalbergiphenols from Zhuang medicine Dalbergia rimosa Roxb
Cheng-sheng LU ; Wei-yu WANG ; Min ZHU ; Si-si QIN ; Zhao-hui LI ; Chen-yan LIANG ; Xu FENG ; Jian-hua WEI
Acta Pharmaceutica Sinica 2024;59(2):418-423
Twelve compounds were isolated from the ethyl acetate fraction of the 80% aqueous ethanol extract of the roots and stems of
7.Research of the interaction between Wnt/β-catenin signaling and the EMT pathway in mediating sunitinib-resistance in renal cancer cells
Fang-Zhen CAI ; Yan-Mei ZHANG ; Si-Huai HUANG ; Wen-Bin LIU ; Wei-Feng ZHUO ; Jian-Wei LI
The Chinese Journal of Clinical Pharmacology 2024;40(17):2483-2487
Objective To investigate the mechanism of the interaction between Wnt/β-catenin signaling and the epithelial mesenchymal transition(EMT)pathway in mediating sunitinib-resistance in renal cancer cells.Methods The sunitinib-resistant kidney cancer cell lines were constructed by stepwise increase in drug concentrations method with sunitinib,and were divided into resistance group,lv-NC group and lv-Twist group,and human kidney cancer cell lines were selected as normal group.The normal and drug-resistant groups were treated with conventional culture;the lv-NC group was treated with 40 μL of lv-NC lentivirus supernatant containing 2.25 × 108 TU·mL-1 for 72 h,and the lv-Twist group was treated with 50 μL of Twist lentivirus supernatant containing 1.64 × 108 TU·mL-1 for 72 h.The apoptosis ability was detected by flow cytometry;the cell migration ability was detected by cell scratch assay;the cell invasion ability was detected by Transwell assay;and the protein expression levels of Wnt1,β-catenin and Twist were detected by Western blotting assay.Results The apoptosis rates of control,resistant,lv-NC and lv-Twist groups were(17.60±0.59)%,(8.61±0.34)%,(8.60±0.40)%and(3.10±0.34)%;the migration rates were(14.10±0.12)%,(27.64±0.41)%,(14.24±0.45)%and(32.74±2.53)%;the number of invading cells was 27.33±1.15,53.33±1.53,46.00±2.65 and 99.33±2.52;the relative expression levels of Wnt1 protein were 0.10±0.01,0.96±0.06,0.39±0.03 and 3.09±0.31;the relative expression levels of β-catenin protein were 0.39±0.01,1.48±0.16,0.81±0.05 and 1.24±0.14;the relative expression levels of Twist protein were 0.10±0.02,0.91±0.04,0.39±0.03 and 3.09±0.31,respectively.The differences of above indexes were statistically significant between the resistant group and the normal group,and between the lv-Twist group and the lv-NC group(all P<0.05).Conclusion Twist(EMT related protein)mediates sunitinib resistance in renal cell carcinoma by interacting with Wnt/β-catenin signaling pathway.
8.A new furan α -butenolactones from Alisma orientale and their potential antifibrotic activities
Deng-hui ZHU ; Peng-li GUO ; Si-qi TAO ; Jing-ke ZHANG ; Meng-nan ZENG ; Xiao-ke ZHENG ; Wei-sheng FENG
Acta Pharmaceutica Sinica 2024;59(7):2058-2061
Four furan
9.A new iridoid from Eucommia ulmoides
Shi-qi ZHOU ; Zhi-you HAO ; Meng YANG ; Chao-yuan XIAO ; Jun-yang ZHANG ; Bo-wen ZHANG ; Si-qi TAO ; Xiao-ke ZHENG ; Wei-sheng FENG
Acta Pharmaceutica Sinica 2024;59(7):2062-2068
Eleven compounds were isolated from
10.Salidroside Ameliorates Lung Injury Induced by PM2.5 by Regulating SIRT1-PGC-1α in Mice
Hong Xiao LI ; Mei Yu LIU ; Hui SHAN ; Feng Jin TAN ; Jian ZHOU ; Jin Yuan SONG ; Qi Si LI ; Chen LIU ; Qun Dong XU ; Li YU ; Wei Wan LI
Biomedical and Environmental Sciences 2024;37(4):367-376
Objective This study aimed to clarify the intervention effect of salidroside(SAL)on lung injury caused by PM2.5 in mice and illuminate the function of SIRT1-PGC-1ɑ axis. Methods Specific pathogen-free(SPF)grade male C57BL/6 mice were randomly assigned to the following groups:control group,SAL group,PM2.5 group,SAL+PM2.5 group.On the first day,SAL was given by gavage,and on the second day,PM2.5 suspension was given by intratracheal instillation.The whole experiment consist of a total of 10 cycles,lasting 20 days.At the end of treatment,blood samples and lung tissues were collected and analyzed.Observation of pathological changes in lung tissue using inverted microscopy and transmission electron microscopy.The expression of inflammatory,antioxidants,apoptosis,and SIRT1-PGC-1ɑ proteins were detected by Western blotting. Results Exposure to PM2.5 leads to obvious morphological and pathologica changes in the lung of mice.PM2.5 caused a decline in levels of antioxidant-related enzymes and protein expressions of HO-1,Nrf2,SOD2,SIRT1 and PGC-1ɑ,and an increase in the protein expressions of IL-6,IL-1β,Bax,caspase-9 and cleaved caspase-3.However,SAL reversed the aforementioned changes caused by PM2.5 by activating the SIRT1-PGC-1α pathway. Conclusion SAL can activate SIRT1-PGC-1ɑ to ameliorate PM2.5-induced lung injury.

Result Analysis
Print
Save
E-mail