1.Clinicopathological features and molecular genetic characteristics of central nerv-ous system high-grade neuroepithelial tumors with BCOR alterations
Ming HAN ; Wanming HU ; Hongjuan ZHANG ; Yingmei WANG ; Danhui ZHAO ; Zhenyu KE ; Zhe WANG ; Yu-qiao XU
Chinese Journal of Clinical and Experimental Pathology 2025;41(9):1156-1162
Purpose To investigate the clinicopathological features,diagnosis,and molecular genetic characteris-tics of central nervous system(CNS)high-grade neuroepithelial tumors with BCOR alterations.Methods Five cases of CNS high-grade neuroepithelial tumors harboring BCOR alterations were collected.Using immunohistochemistry and molecular detection to analyze its clinical and histological characteristics,and review relevant literatures.Results A-mong the 5 patients,3 cases with EP300 ∷ BCOR tumor(male-to-female ratio 2∶1).These tumors were located in supratentorial regions(right temporal lobe,right frontotemporal lobe,and right frontal lobe).The 2 patients with BCOR-ITD tumors were younger,both with tumors located in the left cerebellum.Imaging studies revealed well-defined large mass lesions in all cases.Histologically,all 5 cases tumor exhibited ependymoma-like or oligodendroglioma-like morphology,featuring uniformly oval or round cells.Focal areas showed increased cellular density,nuclear enlarge-ment,and readily identifiable mitotic figures indicative of anaplastic features.A rich capillary network was frequently observed in the stroma.Palisading necrosis,microcystic changes,and microcalcifications were present in 3 cases.Im-munohistochemically,all 5 cases consistently expressed vimentin and CD56,focal Olig-2 positivity,variable S-100 ex-pression,and were uniformly negative for GFAP.BCOR immunostaining was weakly positive in 1 case with an EP300∷ BCOR fusion and strongly positive in 2 cases with BCOR-ITD.NGS identified an EP300 ∷ BCOR fusion in 3 cases,and Sanger sequencing confirmed the ITD in exon 15 of BCOR gene in 2 cases.During a follow-up period of 8 to 77 months,one pediatric patient with a BCOR-ITD tumor died,while the remaining four patients were alive with no evi-dence of recurrence or metastasis.Conclusion BCOR-ITD and EP300 ∷ BCOR fusion tumors are similar in morphology and immunophenotype,and the incidence rate of BCOR fusion tumors may be underestimated.NGS sequencing based on DNA and RNA and DNA methylation spectrum analysis are helpful for accurate diagnosis of this type of tumor.
2.Effect of miR-129-3p mimetic on bone loss in tail-suspended mice
Yi WU ; Zi-dong AN ; Yong-jie PANG ; Li-qiang WANG ; Xin-yang WANG ; Yu-hai GAO ; Xue-yan LI ; Ke-ming CHEN
Chinese Pharmacological Bulletin 2025;41(4):703-709
Aim To study whether intravenous injec-tion of miR-129-3p mimetic(agomir)can resist bone loss caused by hind limb disuse,and to provide new i-deas for preventing bone loss in microgravity environ-ment.Methods Forty-eight C57BL/6J male mice were randomly divided into the control group(CON),tail suspension model group(TS),tail suspension+miR-129-3p agomir administration group(miRNA)and tail suspension+miR-129-3p negative sequence agomir control group(NC).The miRNA group was given 4 mg·kg-1 miR-129-3p agomir by intravenous injection into the medial canthus twice a week.The NC agomir group were consistent with those in the miR-129-3p agomir group,and the CON and TS groups were given only equal volumes of normal saline.After four weeks,all mice were sacrificed and samples were collected.Micro-CT scan of femur,three-point femur bending test,serum bone metabolism index detection,oxidative stress index detection and osteogenesis-related protein expression analysis in bone tissue were per-formed.Results After four weeks,the number of tra-becular bone in the TS group was significantly re-duced,and Tb.BMD,Tb.Th,Tb.N,Tb.BS/TV and Tb.BV/TV were significantly lower than those in the CON group(P<0.01).While Tb.Sp TS group was significantly higher than the CON group(P<0.05),the maximum load and flexural strength of the femur significantly decreased(P<0.01),the content of ser-um bone formation index PINP was significantly lower than that of the CON group(P<0.01),and the con-tent of bone resorption index CTX-I was significantly higher than that of the CON group(P<0.01),the content of serum oxidative damage indexes 8-iso-PGF2α and 8-OHdG significantly increased(P<0.01),and the expression of osteogenesis-related pro-teins in bone tissue markedly decreased(P<0.01).However,the increase or decrease of all indexes in miRNA group was significantly lower than that in TS group.Conclusions miR-129-3p mimetic can signifi-cantly reduce bone loss caused by hind limb disuse.This experiment provides a new idea and method for preventing bone loss in microgravity environment.
3.Risk prevention and control and quality efficiency improvement of medical equipment procurement
Quan-quan LI ; Ming QIU ; Shu-ying LI ; Xin-yi HUANG ; Yu ZHENG ; Zhi-ling WANG ; Ke MA
Chinese Medical Equipment Journal 2025;46(3):81-85
Objective To investigate the impact of risk prevention and control on the quality efficiency of medical equipment procurement.Methods The medical equipment procurement projects with enhanced risk prevention measures during 2023(119 items)were assigned to an observation group,while those without strengthened risk control during 2022(118 items)were enrolled into a control group.The two groups were compared in terms of bid failure/rejection rates,procurement completion cycles(including procurement execution cycle and total procurement cycle)and procurement satisfaction.Statistical analysis was performed using SPSS 20.0 software.Results The observation group demonstrated significantly lower bid failure/rejection rates when compared with the control group(≥2 occurrences:5.88%vs.15.25%,P<0.05).The procurement execution cycle was notably shorter in the observation group((69.16±78.65)d vs.(97.67±49.84)d,P<0.05),though no significant difference was observed in total procurement cycle(P>0.05).The observation group behaved better significantly than the control group in procurement efficiency,equipment performance,procedural compliance and post-purchase service satisfaction(all P<0.05).Conclusion Risk prevention and control measures in medical equipment procurement effectively reduce bid failure/rejection risks while enhancing procurement quality efficiency.[Chinese Medical Equipment Journal,2025,46(3):81-85]
4.Clinicopathological features and molecular genetic characteristics of central nerv-ous system high-grade neuroepithelial tumors with BCOR alterations
Ming HAN ; Wanming HU ; Hongjuan ZHANG ; Yingmei WANG ; Danhui ZHAO ; Zhenyu KE ; Zhe WANG ; Yu-qiao XU
Chinese Journal of Clinical and Experimental Pathology 2025;41(9):1156-1162
Purpose To investigate the clinicopathological features,diagnosis,and molecular genetic characteris-tics of central nervous system(CNS)high-grade neuroepithelial tumors with BCOR alterations.Methods Five cases of CNS high-grade neuroepithelial tumors harboring BCOR alterations were collected.Using immunohistochemistry and molecular detection to analyze its clinical and histological characteristics,and review relevant literatures.Results A-mong the 5 patients,3 cases with EP300 ∷ BCOR tumor(male-to-female ratio 2∶1).These tumors were located in supratentorial regions(right temporal lobe,right frontotemporal lobe,and right frontal lobe).The 2 patients with BCOR-ITD tumors were younger,both with tumors located in the left cerebellum.Imaging studies revealed well-defined large mass lesions in all cases.Histologically,all 5 cases tumor exhibited ependymoma-like or oligodendroglioma-like morphology,featuring uniformly oval or round cells.Focal areas showed increased cellular density,nuclear enlarge-ment,and readily identifiable mitotic figures indicative of anaplastic features.A rich capillary network was frequently observed in the stroma.Palisading necrosis,microcystic changes,and microcalcifications were present in 3 cases.Im-munohistochemically,all 5 cases consistently expressed vimentin and CD56,focal Olig-2 positivity,variable S-100 ex-pression,and were uniformly negative for GFAP.BCOR immunostaining was weakly positive in 1 case with an EP300∷ BCOR fusion and strongly positive in 2 cases with BCOR-ITD.NGS identified an EP300 ∷ BCOR fusion in 3 cases,and Sanger sequencing confirmed the ITD in exon 15 of BCOR gene in 2 cases.During a follow-up period of 8 to 77 months,one pediatric patient with a BCOR-ITD tumor died,while the remaining four patients were alive with no evi-dence of recurrence or metastasis.Conclusion BCOR-ITD and EP300 ∷ BCOR fusion tumors are similar in morphology and immunophenotype,and the incidence rate of BCOR fusion tumors may be underestimated.NGS sequencing based on DNA and RNA and DNA methylation spectrum analysis are helpful for accurate diagnosis of this type of tumor.
5.MRI artifact for the structural detection of inner ear using 3D FIESTA-C and 3D-Cube T2
Ke YANG ; Yutao WANG ; Juanli XING ; Yanning YUAN ; Xingpu QUAN ; Yuxin FAN ; Ming ZHANG ; Yuan WANG
Journal of Xi'an Jiaotong University(Medical Sciences) 2025;46(3):538-543
Objective To analyze the MRI artifact of the inner ear structure in patients with peripheral vertigo acquired by using 3D fast imaging employing steady state acquisition(3D FIESTA-C)and 3D fast spin echo(3D-Cube T2).Methods Data of 63 patients with peripheral vertigo treated in the Department of Otolaryngology,The First Affiliated Hospital of Xi'an Jiaotong University,from October 2023 to June 2024 were filtered for analysis.The patients consisted of 16 males and 47 females,aged 18 to 60 years old.Two senior radiologists independently evaluated the quality of the acquired images through the two MRI sequences.Kappa test was used to evaluate the consistency of the two radiologists' subjective judgments,and Wilcoxon signed-rank test was used to compare the image quality between each sequence.The accuracy of 3D FIESTA-C,3D-Cube T2 and combination of the two sequences was calculated in the presentation of inner ear structure.Results The overall image quality of 3D-Cube T2 was better than that of 3D FIESTA-C(Z=-11.670,P<0.001),and the accuracy of 3D FIESTA-C combined with 3D-Cube T2 was superior to that of each sequence in demonstrating the semicircular canals.The demonstration accuracy of horizontal semicircular canal among three scan protocols was statistically different(P<0.001).Conclusion 3D FIESTA-C has the advantage in detecting horizontal semicircular canal,and 3D-Cube T2 always provides high quality images of upper semicircular canal.Compared with each scanning sequence,3D FIESTA-C combined with 3D-Cube T2 can effectively avoid misdiagnosis or missed diagnosis of semicircular canal structures in the patients with peripheral vertigo.
6.Simultaneous management of transcatheter aortic valve replacement and transcatheter mitral valve edge-to-edge repair for a case of aortic regurgitation combined mitral valve prolapse
Yun-long MA ; Rui-feng LI ; Ming-jun HE ; Shun WANG ; Xiao-zhen ZHUO ; Ke HAN
Chinese Journal of Interventional Cardiology 2025;33(10):588-593
Aortic regurgitation and mitral regurgitation are more common in elderly heart valve disease,and both may be present in some patients.Severe aortic regurgitation complicated with severe mitral regurgitation often requires surgical valve replacement,but in patients at high risk of surgery,the risk of perioperative mortality is significantly increased.Therefore,for such patients,minimally invasive interventions can significantly improve long-term patient outcomes while reducing surgical risk.This article report a case of transcatheter aortic valve replacement combined with transcatheter edge-to-edge repair in the treatment of severe aortic regurgitation combined with mitral valve prolapse,in order to explore new treatment ideas for similar cases.
7.Simultaneous management of transcatheter aortic valve replacement and transcatheter mitral valve edge-to-edge repair for a case of aortic regurgitation combined mitral valve prolapse
Yun-long MA ; Rui-feng LI ; Ming-jun HE ; Shun WANG ; Xiao-zhen ZHUO ; Ke HAN
Chinese Journal of Interventional Cardiology 2025;33(10):588-593
Aortic regurgitation and mitral regurgitation are more common in elderly heart valve disease,and both may be present in some patients.Severe aortic regurgitation complicated with severe mitral regurgitation often requires surgical valve replacement,but in patients at high risk of surgery,the risk of perioperative mortality is significantly increased.Therefore,for such patients,minimally invasive interventions can significantly improve long-term patient outcomes while reducing surgical risk.This article report a case of transcatheter aortic valve replacement combined with transcatheter edge-to-edge repair in the treatment of severe aortic regurgitation combined with mitral valve prolapse,in order to explore new treatment ideas for similar cases.
8.Design of performance testing platfrom for proportional solenoid valves in ventilators
Long-ying YE ; Ming-kang TANG ; Pei-pei ZHANG ; Ke-sheng WANG ; Dan LING ; Qian-hong HE
Chinese Medical Equipment Journal 2025;46(1):13-19
Objective To design a performance testing platform to evaluate the working status and performance characteristics of the ventilator proportional solenoid valve.Methods The performance testing platform had its hardware including a high-pressure gas source,a pressure regulating valve,sensors and etc,and its software designed based on PyQt5 and composed of several modules for data acquisition,parameter setting,image display,indicator computation,result output and etc.Two kinds of proportional solenoid valves(Valve 1、Valve2)were selected for static and dynamic tests to verify the performance of the platform.Results The platform developed facilitated the proportional solenoid valve to carry out accurate computation of static and dynamic indicators at real time and time domain and waveform feature extraction of sensor data by precision control and data acquisition for the proportional solenoid valve.Static tests showed that Valve 1 gained advantages over Valve 2 in static flow characteristics involving in lowered repeatability,return error and offset while enhanced stability;dynamic tests indicated Valve 2 had rapid flow variations and significant flow fluctuation impacts,Valve 1 showed smooth dynamic response changes,and Valve 2 behaved better than Valve 1 in dynamic performance.Conclusion The testing platform developed comprehensively demonstrates the performance characteristics and working performance of the ventilator proportional solenoid valve,which is of great significance to enhance the reliability and safety of the ventilator.[Chinese Medical Equipment Journal,2025,46(1):13-19]
9.Risk prevention and control and quality efficiency improvement of medical equipment procurement
Quan-quan LI ; Ming QIU ; Shu-ying LI ; Xin-yi HUANG ; Yu ZHENG ; Zhi-ling WANG ; Ke MA
Chinese Medical Equipment Journal 2025;46(3):81-85
Objective To investigate the impact of risk prevention and control on the quality efficiency of medical equipment procurement.Methods The medical equipment procurement projects with enhanced risk prevention measures during 2023(119 items)were assigned to an observation group,while those without strengthened risk control during 2022(118 items)were enrolled into a control group.The two groups were compared in terms of bid failure/rejection rates,procurement completion cycles(including procurement execution cycle and total procurement cycle)and procurement satisfaction.Statistical analysis was performed using SPSS 20.0 software.Results The observation group demonstrated significantly lower bid failure/rejection rates when compared with the control group(≥2 occurrences:5.88%vs.15.25%,P<0.05).The procurement execution cycle was notably shorter in the observation group((69.16±78.65)d vs.(97.67±49.84)d,P<0.05),though no significant difference was observed in total procurement cycle(P>0.05).The observation group behaved better significantly than the control group in procurement efficiency,equipment performance,procedural compliance and post-purchase service satisfaction(all P<0.05).Conclusion Risk prevention and control measures in medical equipment procurement effectively reduce bid failure/rejection risks while enhancing procurement quality efficiency.[Chinese Medical Equipment Journal,2025,46(3):81-85]
10.MRI artifact for the structural detection of inner ear using 3D FIESTA-C and 3D-Cube T2
Ke YANG ; Yutao WANG ; Juanli XING ; Yanning YUAN ; Xingpu QUAN ; Yuxin FAN ; Ming ZHANG ; Yuan WANG
Journal of Xi'an Jiaotong University(Medical Sciences) 2025;46(3):538-543
Objective To analyze the MRI artifact of the inner ear structure in patients with peripheral vertigo acquired by using 3D fast imaging employing steady state acquisition(3D FIESTA-C)and 3D fast spin echo(3D-Cube T2).Methods Data of 63 patients with peripheral vertigo treated in the Department of Otolaryngology,The First Affiliated Hospital of Xi'an Jiaotong University,from October 2023 to June 2024 were filtered for analysis.The patients consisted of 16 males and 47 females,aged 18 to 60 years old.Two senior radiologists independently evaluated the quality of the acquired images through the two MRI sequences.Kappa test was used to evaluate the consistency of the two radiologists' subjective judgments,and Wilcoxon signed-rank test was used to compare the image quality between each sequence.The accuracy of 3D FIESTA-C,3D-Cube T2 and combination of the two sequences was calculated in the presentation of inner ear structure.Results The overall image quality of 3D-Cube T2 was better than that of 3D FIESTA-C(Z=-11.670,P<0.001),and the accuracy of 3D FIESTA-C combined with 3D-Cube T2 was superior to that of each sequence in demonstrating the semicircular canals.The demonstration accuracy of horizontal semicircular canal among three scan protocols was statistically different(P<0.001).Conclusion 3D FIESTA-C has the advantage in detecting horizontal semicircular canal,and 3D-Cube T2 always provides high quality images of upper semicircular canal.Compared with each scanning sequence,3D FIESTA-C combined with 3D-Cube T2 can effectively avoid misdiagnosis or missed diagnosis of semicircular canal structures in the patients with peripheral vertigo.

Result Analysis
Print
Save
E-mail