1.Ancient and Modern Application and Key Information Analysis of Classic Formula Erchentang
Qing TANG ; Lyuyuan LIANG ; Jialei CAO ; Lan LIU ; Hejia WAN ; Chengxin LUO ; Bingqi WEI ; Yamin KONG ; Bingxiang MA ; Wenli SHI
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(1):262-270
Erchentang is a classic formula widely used by medical practitioners throughout history. In this paper,ancient and modern literature of Erchentang were collected, and bibliometrics was employed to analyze its historic evolution,prescription meaning,herbs origin, processing method,preparation methods, and clinical application. A total of 84 pieces of data were collected, and 58 pieces of data involving 53 ancient medical Chinese books were screened, sorted, and processed. Combined with research of modern scholars,the research has found that the Erchentang originated from the Taiping Huimin Huiye Shijie Fang compiled by the Imperial Medical Bureau of the Song Dynasty. The basic information about the origin of the drugs is quite clear. Pinelliae rhizoma in the formula is the dried tuber of Pinellia ternata. Citri exocarpium rubrum is the dried mature peel of Citrus reticulata and its cultivated varieties, with the inner white membrane removed. Poria is the whitest dry sclerotia of Poria cocos; Glycyrrhizae radix et rhizoma is the dried root and rhizome of the Glycyrrhiza uralensis. The dosage is 5.70 g Pinelliae rhizome and Citri exocarpium rubrum, 3.43 g Poria, and 1.69 g Glycyrrhizae radix et rhizoma praeparata cum melle. During the decoction process, the above-mentioned herbs should be chopped, with 300 mL water, 7 g ginger in thick slices, and 2 g Mume fructus added, and it was then simmered together to 180 mL. After removing the medicinal residue, it can be taken warmly. Erchentang has the effect of drying dampness and resolving phlegm, regulating Qi and harmonizing the middle. It can be used in treating the syndrome of phlegm and dampness,as well as symptoms such as frequent cough,white phlegm,fullness in chest and diaphragm,nausea and vomiting,limb drowsiness,anorexia,dizziness,palpitations,white and greasy tongue coating, and slippery pulse. The above results provide reference for future research and development of Erchentang.
2.Artificial intelligence-based quality control of hand hygiene for hospital-acquired infection
Xuchen YANG ; Jingwen LI ; Wan ZHANG ; Shasha FENG ; Min ZENG ; Jianan SHI ; Youqiong CHEN ; Tao ZHENG ; Xun YAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(02):241-247
Objective To explore an artificial intelligence (AI)-based method for automated hand hygiene monitoring and to compare the effectiveness of three algorithms (UniFormerV2, TDN, C3D) in recognizing hand hygiene steps in surgical settings, thereby aiding hospital infection control. Methods From April to October 2024, we non-invasively collected 641 video recordings of healthcare staff performing hand hygiene at four-bay scrub sinks in two tertiary hospitals using overhead HD cameras. The dataset was annotated by five trained experts for model training and validation. Results Following training on 385 samples, internal validation (n=119) showed the C3D model achieved 81% accuracy, 87% recall, and an 83% F1-score. The TDN model achieved 93%, 91%, and 92% for the same metrics. The UniFormerV2 model outperformed both, with an accuracy, recall, and F1-score of 93%—an improvement of over 10 percentage points compared to traditional CNNs (TDN, C3D). It also achieved an 84% accuracy in external validation, demonstrating strong generalization. Conclusion The UniFormerV2 model is more accurate than CNN-based models for hand hygiene step recognition and shows robust performance in external validation. It presents a viable tool for healthcare facilities to enhance hand hygiene management, ultimately improving medical quality and patient safety.
3.Effect of remote ischemic preconditioning on preoperative heart rate variability in patients undergoing heart valve surgery: A randomized controlled trial
Zhipeng GUO ; Jian ZHANG ; Qiaoli WAN ; Fengyan SHI ; Rui LI ; Zongtao YIN ; Jinsong HAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(04):592-596
Objective To explore the effect of remote ischemic preconditioning (RIPC) on preoperative heart rate variability in patients with heart valves. Methods Patients scheduled to undergo on-pump cardiac valve surgery in the Department of Cardiovascular Surgery, General Hospital of Northern Theater Command, between January and July 2022 were initially enrolled. Eligible patients were randomly assigned at a 1 : 1 ratio to either the RIPC group or the control group. Relevant indicators of heart rate variability [standard deviation of NN interval (SDNN), standard deviation of mean value of NN interval in every five minutes (SDANN), mean square root of difference between consecutive NN intervals (RMSSD), percentage of adjacent RR interval>50 ms (PNN50), low frequency (LF) component, high frequency (HF) component and LF/HF] at 8 hours in the morning on the surgical day between two groups were compared. Results A total of 118 patients were initially assessed. After screening, 58 patients were excluded, and 60 patients provided written informed consent and were enrolled in the trial, with 30 allocated to the RIPC group and 30 to the control group. Seven patients in the control group and 5 patients in the RIPC group were subsequently excluded due to missing heart rate variability data resulting from cancelled operations. Finally, 23 patients in the control group and 25 patients in the RIPC group were included in the analysis. There was no statistical difference in baseline characteristics between the two groups, and there was no significant difference in heart rate variability 24 hours before intervention (P>0.05). After the intervention measures were taken, the comparison of the results of heart rate variability at 8 hours on the day of operation showed that SDNN and SDANN of patients in the RIPC group were higher than those in the control group, with statistical differences (P<0.05). Conclusion RIPC can stabilize the preoperative heart rate variability of patients undergoing cardiac valve surgery.
4.Targeted therapeutic effect of magnolol-loaded mitochondria-targeting immunoliposomes modified by datuximab and triphenylphosphine on neuroblastoma
Jiahui LI ; Zhili CHEN ; Limin SHI ; Mingyu WAN ; Jinfei YAO ; Chengyun YAN
Journal of China Pharmaceutical University 2026;57(2):215-223
To improve the targeted therapeutic effect of magnolol (Mag) on neuroblastoma, Mag-loaded mitochondria-targeting immunoliposomes modified by datuximab (aGD2) and triphenylphosphine (TPP) (Mag/aGD2-T-ILN) were prepared, and their physicochemical properties, targeting characteristics and anti-tumor activity were evaluated. Physico-chemical properties showed that the surface of Mag/aGD2-T-ILN was smooth and spherical, with good dispersibility. The particle sizes, PDI and Zeta potentials of Mag/aGD2-T-ILN were measured to be (136.5 ± 5.1) nm, 0.184 ± 0.010 and (27.5 ± 3.6) mV, respectively. Mag/aGD2-T-ILN could release the drug continuously and slowly, and maintain good stability at 4 ℃. Cytotoxicity test exhibited that the IC50 of 2-ME/aGD2-T-ILN was (4.07 ± 0.48) µmol/L, and compared with free Mag, the toxicity of Mag/aGD2-T-ILN to SH-SY5Y cells increased by 6.4 times. Cellular binding and uptake assays suggested that Rho-aGD2-T-ILN could specifically target GD2-positive tumor cells and then further reach their mitochondria. Therapeutic efficacy indicated that Mag/aGD2-T-ILN could better suppress the growth of SH-SY5Y tumor cells in the body with lower toxicity and less side-effects. The results demonstrated that the Mag/aGD2-T-ILN nanoparticles system could achieve intracellular endocytosis through specific binding of antibodies and antigens between the carrier and the surface of tumor cells and electrostatic interaction, then effectively delivered and released the drugs into mitochondria by crossing the mitochondrial phospholipid membrane through TPP, and thus achieving mitochondria-targeting therapy of Mag/aGD2-T-ILN. Through the construction of this active targeting delivery system, the clinical application value of datuximab and Mag is improved, providing a novel approach for the clinical treatment of neuroblastoma.
5.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
6.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
7.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
8.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
9.Analysis of factors influencing insufficient hyperopia reserve and refractive parameters in preschool children in Hefei
ZHANG Bolin, ZHANG Shanshan, WAN Qianqian, TONG Min, L Pingping, WANG Ke, SHI Huijing
Chinese Journal of School Health 2025;46(6):873-877
Objective:
To investigate the current status of refractive errors and insufficient hyperopia reserve in preschool children aged 3-6 years in Hefei and to analyze influencing factors, so as to provide a scientific basis for formulating targeted myopia prevention policies and comprehensive interventions.
Methods:
In May 2022, a stratified cluster random sampling method was used to select 897 preschool children from 8 kindergartens across four districts (Baohe, Yaohai, Shushan, and Economic and Technological Development Zone) in Hefei, and Children’s Visual Health related Behavior Assessment Scale was used to collect personal information and environmental factors. Pre and post cycloplegic refraction tests were conducted to assess insufficient hyperopic reserve and refractive development levels. Group comparisons were conducted using 2 test, t-test or analysis of variance. Multivariate regression analysis was performed to identify key factors influencing hyperopic reserve, axial length and spherical equivalent in preschool children.
Results:
The detection rates of refractive errors among preschool children were 6.8% for hyperopia, 1.6% for myopia, and 11.1% for astigmatism. Notably, the prevalence of myopia was significantly higher in boys (2.3%) than in girls (0.7%) ( χ 2=3.88, P <0.05). Additionally, 8.8% of the children exhibited insufficient hyperopic reserve. The results of multiple regression analysis showed that preschool children with high myopia in the father, high myopia in the mother, longer daily duration of near work, and longer daily electronic product use time had increased risks of axial growth ( β =0.12, 0.09, 0.15, 0.11), SE reduction ( β =-0.10, -0.07, -0.18, -0.13), and insufficient hyperopic reserve ( OR=1.87, 2.22, 1.40, 1.28) (P <0.05). While, preschool children with longer sleep time and daily outdoor activity duration had lower risks of axial growth ( β =-0.11, -0.10 ), SE reduction ( β =0.39, 0.51), and insufficient hyperopia reserve ( OR =0.54, 0.51) in preschool children ( P <0.05).
Conclusions
The rates of refractive errors and insufficient hyperopia reserve in preschool children in Hefei are relatively low, which are influenced by many factors. Parents, kindergartens and relevant departments should implement early vision monitoring and intervention for preschool children, and cultivate their scientific eye use habits.
10.Efficacy of pelvic floor optimization training of Yun-type aided with myoelectric biofeedback in the treatment of mild to moderate female stress urinary incontinence
Xiaoxiang WAN ; Wei JIAO ; Chaoliang SHI ; Jiawei WANG ; Jialing YAO ; Yangyun WANG ; Xilong WANG
Journal of Modern Urology 2025;30(5):390-394
Objective: To explore the efficacy of pelvic floor optimization training of Yun-type with the aid of myoelectric biofeedback in the treatment of mild to moderate female stress urinary incontinence (SUI). Methods: Female SUI patients treated in our hospital during Jan.and Oct.2024 were included as the research subjects.They were randomly divided into the control group (n=47) and observation group (n=48) by random number method.The control group received conventional Yun-type pelvic floor optimization training,while the observation group received Yun-type pelvic floor optimization training assisted with myoelectric biofeedback.The total treatment course lasted for 12 weeks.The clinical efficacy,as well as the changes in international consultation on incontinence questionnaire for symptoms and impact (ICI-Q-SF),incontinence quality of life (I-QoL),female sexual function index (FSFI),and pelvic floor electromyographic values before and after treatment were compared. Results: The total effective rate of the observation group was 93.6%,which was significantly higher than that of the control group (79.2%,P<0.05).After 12 weeks of treatment,the ICI-Q-SF [(6.12±1.11) vs. (6.97±1.24)],I-QoL [(85.05±4.51) vs. (82.14±4.60)],and FSFI [(30.01±4.10) vs. (26.32±3.32)] scores of the observation group were significantly better than those of the control group (P<0.05).After 12 weeks of treatment,the myoelectric values of the pelvic floor muscles of the observation group at the pre-rest stage,fast muscle (type Ⅱ muscle) stage,slow muscle (type Ⅰ muscle) stage,endurance test stage,and post-rest stage were significantly improved compared with those before treatment and were greatly enhanced compared with those of the control group (P<0.05).No serious adverse reactions occurred in either groups during treatment and follow-up. Conclusion: The Yun-type pelvic floor optimization training assisted with myoelectric biofeedback can precisely enhance the therapeutic effects of the conventional Yun-type pelvic floor optimization training,and significantly improve the female sexual function index.It is worthy of clinical promotion and application.


Result Analysis
Print
Save
E-mail