1.Herbal Textual Research on Houttuyniae Herba in Famous Classical Formulas
Dan ZHAO ; Changgui YANG ; Chuanzhi KANG ; Chenghong XIAO ; Zhikun WU ; Hongliang MA ; Jiwen WANG ; Xiufu WAN ; Sheng WANG ; Zhilai ZHAN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(8):250-259
This article systematically analyzes the historical evolution of the name, medicinal parts, origin, harvesting, processing and other aspects of Houttuyniae Herba(HH) by referring to the medical books, prescription books and other documents of the past dynasties, combined with the research materials related to modern and contemporary times, in order to provide a basis for the development of famous classical formulas containing this herb. In ancient literature, HH was often referred to as "Ji" and "Jicai", the name of "Ji" was first recorded in Mingyi Bielu during the Han and Wei dynasties, and the name of Yuxingcao was first seen in Lyuchanyan Bencao during the southern Song dynasty and has continued to this day. The origin of HH used throughout history is consistent, all of which are the whole herb or aboveground parts of Houttuynia cordata in Saururaceae family. HH recorded throughout history has a wide range of production areas, mostly self-produced self-marketing. In ancient times, fresh HH was often used as medicine by pounding its juice without involving any processing steps. Both fresh and dried products can be used as medicine, the fresh products uses the whole plant, while the dried products uses the aboveground parts, which are cleaned, selected and processed before use. Fresh products are harvested regardless of season, while dried products are harvested in both summer and autumn, with summer as the best. In ancient times, there were no specific requirements for the quality of HH, while in modern times, "intact stems and leaves with a strong fishy smell" are preferred. In addition, the medicinal properties of HH have undergone significant changes from ancient to modern times. In the early period, it was believed that its medicinal property was slightly warm, until the 1977 edition of Chinese Pharmacopoeia officially changed it to slightly cold. Both ancient and modern literature states that HH can be used for the treatment of carbuncle and malignant sores, Lyuchanyan Bencao for the first time introduced HH fresh juice can relieve summer heat, since Diannan Bencao recorded that it can be used for lung carbuncle, and gradually developed into the first choice for the treatment of lung carbuncle. Based on the research results, it is suggested that fresh herb or dried aboveground parts of H. cordata are used as medicine when developing famous classical formulas.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Analysis of risk factors for myopia in preschool children
Kang LU ; Jie XIAO ; Youhai WANG ; Kangrui LIU ; Qing WANG
International Eye Science 2025;25(8):1363-1370
AIM: To investigate the risk factors of myopia, and provide evidence for the prevention and treatment of myopia in preschool children.METHODS:This is a retrospective case-control study. A total of 168 preschool-aged children(168 eyes)were enrolled from the ophthalmology department at Affiliated Hospital of Qingdao University between September 2021 and September 2023, selecting the eye with poorer vision for inclusion; the right eye was selected when both eyes had equal vision. Grouping criteria: Children with spherical equivalent(SE)>0 D and age-appropriate normal visual acuity(≥0.5 for ages 3-5; ≥0.7 for ages 6-7)were directly assigned to the non-myopia group. Children with SE <0 D underwent cycloplegic refraction after 3 days of 1% atropine sulfate gel application(three times daily). Those with SE ≤-0.50 D and failure to achieve age-normal visual acuity(<0.5 for ages 3-5; <0.7 for ages 6-7)were assigned to the myopia group, with 84 children(84 eyes)in each group. All participants underwent measurements of visual acuity, intraocular pressure, refraction, and ocular biometric parameters. Parents or guardians completed risk factor questionnaires during the visit, covering daily outdoor activity duration, daily electronic device usage/reading time, parental myopia status, maternal delivery mode, and full-term birth status.RESULTS:Significant differences were observed in uncorrected visual acuity, spherical power, SE, and axial length between the two groups of children(all P<0.05). No statistically significant differences were found in daily sleep duration, daily reading/homework time, maternal myopia status, mode of delivery, or full-term delivery status(all P>0.05). However, significant differences existed in daily outdoor activity time, daily electronic device usage duration, maternal myopia degree, paternal myopia degree, maternal age of myopia onset, and paternal age of myopia onset(all P<0.05). Logistic regression analysis identified the following risk factors for myopia in preschool children: daily outdoor activity under 2 h, daily electronic device use exceeding 60 min, maternal myopia degree, maternal early-onset myopia, paternal high myopia, and paternal early-onset myopia. Analysis of interaction effects children gender and myopia-related factors on SE revealed significant interactions of children gender with paternal myopia degree, maternal and paternal age of myopia onset(P<0.05). Simple effects analysis further demonstrated that girls exhibited higher degree of myopia than boys in families with paternal early-onset myopia, maternal early-onset myopia, or paternal high myopia(P<0.05).CONCLUSION:Insufficient daily outdoor activity time(under 1 h), daily electronic device use exceeding 60 min, and parental myopia are significant risk factors for myopia development in preschool children. Among these children, girls' refractive status was particularly associated with parental refractive status.
8.SAMSN1 causes sepsis immunosuppression by inducing macrophages to express coinhibitory molecules that cause T-cell exhaustion via KEAP1-NRF2 signaling.
Yao LI ; Tingting LI ; Fei XIAO ; Lijun WANG ; Xuelian LIAO ; Wei ZHANG ; Yan KANG
Chinese Medical Journal 2025;138(13):1607-1620
BACKGROUND:
Immunosuppression is closely related to the pathogenesis of sepsis, but the underlying mechanisms have not yet been fully elucidated. In this study, we aimed to examine the role of the Sterile Alpha Motif, Src Homology 3 domain and nuclear localization signal 1 (SAMSN1) in sepsis and elucidate its potential molecular mechanism in sepsis induced immunosuppression.
METHODS:
RNA sequencing databases were used to validate SAMSN1 expression in sepsis. The impact of SAMSN1 on sepsis was verified using gene knockout mice. Flow cytometry was employed to delineate how SAMSN1 affects immunity in sepsis, focusing on immune cell types and T cell functions. Clustered regularly interspaced short palindromic repeats (CRISPR)/CRISPR-associated protein 9 (Cas9)-mediated gene editing in RAW264.7 macrophages enabled interrogation of SAMSN1 's regulatory effects on essential macrophage functions, including cell proliferation and phagocytic capacity. The mechanism of SAMSN1 in the interaction between macrophages and T cells was investigated using the RAW264.7 cell line and primary cell lines.
RESULTS:
SAMSN1 expression was significantly increased in patients with sepsis and was positively correlated with sepsis mortality. Genetic deletion of Samsn1 in murine sepsis model improved T cell survival, elevated T cell cytolytic activity, and activated T cell signaling transduction. Concurrently, Samsn1 knockout augmented macrophage proliferation capacity and phagocytic efficiency. In macrophage, SAMSN1 binds to Kelch-like epichlorohydrin-associated protein 1 (KEAP1), causing nuclear factor erythroid 2-related factor 2 (NRF2) to dissociate from the KEAP1-NRF2 complex and translocate into the nucleus. This promotes the transcription of the coinhibitory molecules CD48/CD86/carcinoembryonic antigen related cell adhesion molecule 1 (CEACAM1), which bind to their corresponding receptors natural killer cell receptor 2B4/CD152/T cell immunoglobulin and mucin domain-containing protein 3 (TIM3) on the surface of T cells, inducing T-cell exhaustion.
CONCLUSIONS
SAMSN1 deletion augmented adaptive T cell immunity and macrophage phagocytic-proliferative dual function. Furthermore, it mediates the KEAP1-NRF2 axis, which affects the expression of coinhibitory molecules on macrophages, leading to T-cell exhaustion. This novel immunosuppression mechanism potentially provides a candidate molecular target for sepsis immunotherapy.
Animals
;
NF-E2-Related Factor 2/metabolism*
;
Mice
;
Macrophages/immunology*
;
Sepsis/metabolism*
;
Kelch-Like ECH-Associated Protein 1/genetics*
;
T-Lymphocytes/immunology*
;
Humans
;
Signal Transduction/physiology*
;
RAW 264.7 Cells
;
Mice, Knockout
;
Mice, Inbred C57BL
;
Male
;
Flow Cytometry
;
T-Cell Exhaustion
9.Efficacy and safety of using an enteral immunonutrition formula in the enhanced recovery after surgery protocol for Chinese patients with gastrointestinal cancers undergoing surgery: A randomized, open-label, multicenter trial (healing trial).
Jianchun YU ; Gang XIAO ; Yanbing ZHOU ; Yingjiang YE ; Han LIANG ; Guole LIN ; Qi AN ; Xiaodong LIU ; Bin LIANG ; Baogui WANG ; Weiming KANG ; Tao YU ; Yulong TIAN ; Chao WANG ; Xiaona WANG
Chinese Medical Journal 2025;138(21):2847-2849
10.Pharmacokinetics study of Dayuanyin in normal and febrile rats.
Yu-Jie HOU ; Kang-Ning XIAO ; Jian-Yun BI ; Xin-Jun ZHANG ; Xin-Rui LI ; Yu-Qing WANG ; Ming SU ; Xin-Ru SUN ; Hui ZHANG ; Bo-Yang WANG ; Li-Jie WANG ; Shan-Xin LIU
China Journal of Chinese Materia Medica 2025;50(2):527-533
Based on the pharmacokinetics theory, this study investigated the pharmacokinetic characteristics of albiflorin, paeoniflorin, wogonoside, and wogonin in normal and febrile rats and summarized absorption and elimination rules of Dayuanyin in them to provide reference for further development and clinical application of Dayuanyin. Blood samples were taken from the fundus venous plexus of normal and model rats after intragastric administration of Dayuanyin at different time points. The concentration of each substance in blood was determined by ultra performance liquid chromatography-triple quadrupole mass spectrometry(UPLC-MS/MS) technique at different time points. DAS 2.0, a piece of pharmacokinetics software, was used to calculate the pharmacokinetic parameters of each component. The results show that the 4 components had good linear relationship in their respective ranges, and the results of methodological investigation met the requirements. The pharmacokinetic parameters of C_(max), T_(max), t_(1/2), AUC_(0-t), AUC_(0-∞), and MRT_(0-t) were calculated by the DAS 2.0 non-compartmental model. Compared with those in the normal group, C_(max) and AUC_(0-t) of the 4 components in the model group were significantly increased. There were significant differences in the pharmacokinetic characteristics between the normal and model groups, suggesting that the absorption and elimination of Dayuanyin may be affected by the changes of internal environment of the body in different physiological states.
Animals
;
Rats
;
Drugs, Chinese Herbal/administration & dosage*
;
Male
;
Rats, Sprague-Dawley
;
Fever/metabolism*
;
Tandem Mass Spectrometry
;
Chromatography, High Pressure Liquid
;
Glucosides/pharmacokinetics*
;
Monoterpenes

Result Analysis