1.Predictive value of ultrasound-derived quantitative indicators of umbilical cord hypercoiling and hemodynamic parameters for adverse pregnancy outcomes.
Xiaotan TAN ; Qichang ZHOU ; Hongxia YUAN ; Da HOU ; Yunfang ZHU ; Ruji YAO
Journal of Central South University(Medical Sciences) 2025;50(7):1179-1187
OBJECTIVES:
The diagnostic value of ultrasonographic quantitative indicators of umbilical cord coiling, such as the umbilical coiling index (UCI) and pitch value, in identifying hypercoiling and predicting adverse pregnancy outcomes remains controversial. This study aims to evaluate the predictive value of UCI, pitch value, and the cerebroplacental ratio in pregnancies complicated by umbilical cord hypercoiling.
METHODS:
Pregnant women with densely coiled umbilical cords identified by routine obstetric ultrasound at Changsha Maternal and Child Health Hospital between November 2022 and November 2024 were enrolled. Complete clinical data, including UCI, pitch value, and cerebroplacental ratio (CPR), were collected. Pregnancy outcome scores were calculated, and newborns were categorized into the normal outcome group (n=177) and adverse outcome group (n=85), with the latter further subdivided into mild (n=51), moderate (n=19), and severe (n=15) subgroups. Differences in baseline data, UCI, pitch value, and incidence of CRP<1 were compared between groups and among subgroups. Correlations between UCI, pitch value, and adverse pregnancy outcomes were analyzed. Receiver operating characteristic (ROC) curve were used to assess the predictive performance of UCI, pitch value, CPR<1, and their combinations.
RESULTS:
Compared with the normal outcome group, the adverse outcome group had higher age, parity, parity, incidence of CPR<1, and UCI, while gestational age at delivery and pitch values were lower (all P<0.05). The incidence of obesity, gestational diabetes mellitus, and hypertensive disorders of pregnancy did not differ significantly between the 2 groups (all P>0.05). The normal outcome group showed lower UCI and higher pitch values than all 3 adverse outcome subgroups (all P<0.05), while differences among the 3 adverse subgroups were not significant (all P>0.05). UCI was positively correlated with adverse pregnancy outcomes (rs=0.350, P<0.05), whereas pitch value was negatively correlated (rs=-0.286, P<0.05). ROC curve analysis showed that the area under the curve (AUC) values for predicting adverse outcomes were 0.837 for UCI, 0.886 for pitch value, and 0.610 for CPR<1, with sensitivities of 77.6%, 82.4%, and 27.1% and specificities of 78.5%, 83.6%, and 94.9%, respectively. The combined UCI+CPR<1 and pitch value+CPR<1 models yielded AUCs of 0.841 and 0.886, with sensitivities of 78.8% and 81.2% and specificities of 78.5% and 84.2%, respectively. No significant differences were found between the AUCs of UCI and pitch value (P>0.05), but both outperformed CPR<1 alone (both P<0.001). The combined models showed no significant improvement over UCI or pitch value alone (both P>0.05), though both were superior to CPR<1 alone (both P<0.001).
CONCLUSIONS
Most umbilical cord hypercoiling cases had favorable outcomes, with UCI, pitch value, CPR<1 and their combinations demonstrating significant predictive value for adverse pregnancy outcomes.
Humans
;
Female
;
Pregnancy
;
Pregnancy Outcome
;
Adult
;
Ultrasonography, Prenatal/methods*
;
Umbilical Cord/diagnostic imaging*
;
Hemodynamics
;
Predictive Value of Tests
;
Infant, Newborn
;
ROC Curve
3.The haemodynamic effects of umbilical cord milking in term infants: a randomised controlled trial.
Mehmet TEKIN ; Mahmut GOKDEMIR ; Erzat TOPRAK ; Musa SILAHLI ; Hasan ENERGIN ; Zeynel GOKMEN
Singapore medical journal 2023;64(7):439-443
INTRODUCTION:
Umbilical cord milking (UCM) is a method that allows for postnatal placental transfusion. The benefits of UCM have been demonstrated in some studies, but knowledge about its haemodynamic effects in term infants is limited. The aim of this study was to evaluate the haemodynamic effects of UCM in term infants.
METHODS:
In this prospective, randomised controlled study, 149 healthy term infants with a birth week of ≥37 weeks were randomly assigned to either the UCM or immediate cord clamping (ICC) group. Blinded echocardiographic evaluations were performed in all the neonates in the first 2-6 h.
RESULTS:
Superior vena cava (SVC) flow measurements were higher in the UCM group compared to the ICC group (132.47 ± 37.0 vs. 126.62 ± 34.3 mL/kg/min), but this difference was not statistically significant. Left atrial diameter (12.23 ± 1.99 vs. 11.43 ± 1.78 mm) and left atrium-to-aorta diastolic diameter ratio (1.62 ± 0.24 vs. 1.51 ± 0.22) were significantly higher in the UCM group. There were no significant differences in other echocardiographic parameters between the two groups.
CONCLUSION
We found no significant difference in the SVC flow measurements in term infants who underwent UCM versus those who underwent ICC. This lack of significant difference in SVC flow may be explained by the mature cerebral autoregulation mechanism in term neonates.
Infant, Newborn
;
Infant
;
Humans
;
Pregnancy
;
Female
;
Infant, Premature/physiology*
;
Umbilical Cord Clamping
;
Prospective Studies
;
Vena Cava, Superior/diagnostic imaging*
;
Placenta
;
Umbilical Cord/physiology*
;
Constriction
;
Hemodynamics/physiology*
4.Deformation of the left and right ventricular longitudinal myocardium in fetuses with umbilical cord around neck.
Dong-Mei ZUO ; Chao-Hong WANG ; Yue-Heng WANG
Chinese Medical Journal 2012;125(9):1608-1613
BACKGROUNDUmbilical cord around neck, a common obstetric complication, affects fetal hemodynamics. Does it influence fetal cardiac functions? The purpose of this study was to investigate the left and right ventricular systolic and diastolic functions of fetuses with umbilical cord around neck in the third trimester by applying velocity vector imaging (VVI).
METHODSThirty-five cases of fetuses with umbilical cord around neck whose gestational ages from 35 to 40 weeks were selected, including 20 cases of umbilical artery ratio of the highest systolic velocity (S) to the lowest diastolic velocity (D) (S/D) < 3.0 and 15 cases of umbilical artery S/D ≥ 3.0, while 20 cases of normal fetuses of 35 - 40 gestational weeks were selected as the control group. The changes in longitudinal velocity, strain, and strain rate of fetal left and right ventricle in systole and diastole in two groups, and the changes in fetal cardiac function under the situation of umbilical cord around neck were analyzed.
RESULTSLongitudinal strain and strain rate overall of fetal left and right ventricle in systole and diastole were less in fetuses with umbilical artery S/D (3)3.0 and umbilical cord around neck than those in fetuses with umbilical artery S/D < 3.0 and those in control group (P < 0.05); there was no significant difference (P > 0.05) in longitudinal strain and strain rate overall of fetal left and right ventricle in systole and diastole between fetuses with umbilical artery S/D < 3.0 and those in control group.
CONCLUSIONSLeft and right ventricular systolic and diastolic dysfunction was detected in fetuses with umbilical cord around neck and umbilical artery S/D (3)3.0. VVI could sensitively respond to cardiac function changes in fetuses with umbilical cord around neck, which provides another valuable method in the evaluation of fetal cardiac function.
Adult ; Female ; Fetus ; abnormalities ; physiopathology ; Gestational Age ; Heart Ventricles ; diagnostic imaging ; pathology ; physiopathology ; Humans ; Myocardium ; pathology ; Pregnancy ; Pregnancy Complications ; Ultrasonography, Prenatal ; Umbilical Arteries ; diagnostic imaging ; pathology ; physiopathology ; Umbilical Cord ; diagnostic imaging ; physiopathology ; Young Adult

Result Analysis
Print