1.Nomogram-based predictive model for intra-myometrial contrast agent reflux using imaging features from 4D hysterosalpingo-contrast sonography.
Xia YANG ; Liangying PAN ; Xingping ZHAO ; Jingjia YI ; Lin WANG ; Baiyun ZHANG
Journal of Central South University(Medical Sciences) 2025;50(1):61-71
OBJECTIVES:
According to the World Health Organization (WHO), infertility rates have been steadily rising worldwide. Identifying risk factors for contrast agent reflux into the myometrium during hysterosalpingo-contrast sonography (HyCoSy) is of clinical significance in reducing this complication and improving infertility treatment. However, there is currently no standardized pre-evaluation method for predicting intra-myometrial contrast reflux, with clinical assessment often relying on physician experience and patient symptoms. This study aims to identify imaging risk factors for contrast agent reflux into the myometrium using four-dimensional (4D) HyCoSy and to construct a nomogram-based predictive model to assist in clinical decision-making.
METHODS:
A retrospective analysis was conducted on 1 274 infertile women who underwent 4D HyCoSy at the Women and Children's Hospital of Hunan and the the Third Xiangya Hospital of Central South University from January 1, 2020, to December 15, 2022. Patients were divided into a reflux group (n=234) and a non-reflux group (n=1 040) based on the presence of intra-myometrial contrast reflux. Univariate and multivariable Logistic regression analyses were used to identify significant predictors, which were then used to construct a nomogram model. Internal validation was performed using 500 bootstrap resamples.
RESULTS:
The age of the reflux group was significantly higher than that of the non-reflux group [(31.82±5.27) years vs (30.66±4.83) years, P=0.001 1]. Primary infertility was more common in the non-reflux group (50.96%), while secondary infertility dominated in the reflux group (76.50%), with 72.65% having a history of gynecological surgery (P<0.001). Abnormal menstrual volume and discomfort during the procedure were more common in the reflux group, while the non-reflux group tolerated higher contrast agent doses (P<0.001). Imaging differences included endometrial thickness, tubal wall smoothness, and peritoneal contrast dispersion, with the non-reflux group showing thicker endometrium and smoother, more patent tubes. The nomogram model yielded an area under the curve (AUC) of 0.854, indicating good predictive performance. The AUC of the decision curve analysis (DCA) for internal validation of the model was 0.737. When the threshold probability for contrast agent reflux into the myometrium ranged from 0.05 to 0.95, the maximum net benefit reached 0.18. The net benefit of applying the nomogram predictive model exceeded that of either full intervention or no intervention, indicating that the model demonstrates good clinical predictive performance.
CONCLUSIONS
The nomogram model, based on infertility type, endometrial thickness, contrast agent dose, and discomfort symptoms, effectively predicts intra-myometrial contrast agent reflux after 4D HyCoSy. It provides a valuable tool for clinicians to implement early preventive measures and reduce the risk of contrast leakage and associated complications.
Humans
;
Female
;
Nomograms
;
Contrast Media/adverse effects*
;
Retrospective Studies
;
Adult
;
Ultrasonography/methods*
;
Hysterosalpingography/methods*
;
Infertility, Female/diagnostic imaging*
;
Myometrium/diagnostic imaging*
;
Risk Factors
2.Predictive value of ultrasound-derived quantitative indicators of umbilical cord hypercoiling and hemodynamic parameters for adverse pregnancy outcomes.
Xiaotan TAN ; Qichang ZHOU ; Hongxia YUAN ; Da HOU ; Yunfang ZHU ; Ruji YAO
Journal of Central South University(Medical Sciences) 2025;50(7):1179-1187
OBJECTIVES:
The diagnostic value of ultrasonographic quantitative indicators of umbilical cord coiling, such as the umbilical coiling index (UCI) and pitch value, in identifying hypercoiling and predicting adverse pregnancy outcomes remains controversial. This study aims to evaluate the predictive value of UCI, pitch value, and the cerebroplacental ratio in pregnancies complicated by umbilical cord hypercoiling.
METHODS:
Pregnant women with densely coiled umbilical cords identified by routine obstetric ultrasound at Changsha Maternal and Child Health Hospital between November 2022 and November 2024 were enrolled. Complete clinical data, including UCI, pitch value, and cerebroplacental ratio (CPR), were collected. Pregnancy outcome scores were calculated, and newborns were categorized into the normal outcome group (n=177) and adverse outcome group (n=85), with the latter further subdivided into mild (n=51), moderate (n=19), and severe (n=15) subgroups. Differences in baseline data, UCI, pitch value, and incidence of CRP<1 were compared between groups and among subgroups. Correlations between UCI, pitch value, and adverse pregnancy outcomes were analyzed. Receiver operating characteristic (ROC) curve were used to assess the predictive performance of UCI, pitch value, CPR<1, and their combinations.
RESULTS:
Compared with the normal outcome group, the adverse outcome group had higher age, parity, parity, incidence of CPR<1, and UCI, while gestational age at delivery and pitch values were lower (all P<0.05). The incidence of obesity, gestational diabetes mellitus, and hypertensive disorders of pregnancy did not differ significantly between the 2 groups (all P>0.05). The normal outcome group showed lower UCI and higher pitch values than all 3 adverse outcome subgroups (all P<0.05), while differences among the 3 adverse subgroups were not significant (all P>0.05). UCI was positively correlated with adverse pregnancy outcomes (rs=0.350, P<0.05), whereas pitch value was negatively correlated (rs=-0.286, P<0.05). ROC curve analysis showed that the area under the curve (AUC) values for predicting adverse outcomes were 0.837 for UCI, 0.886 for pitch value, and 0.610 for CPR<1, with sensitivities of 77.6%, 82.4%, and 27.1% and specificities of 78.5%, 83.6%, and 94.9%, respectively. The combined UCI+CPR<1 and pitch value+CPR<1 models yielded AUCs of 0.841 and 0.886, with sensitivities of 78.8% and 81.2% and specificities of 78.5% and 84.2%, respectively. No significant differences were found between the AUCs of UCI and pitch value (P>0.05), but both outperformed CPR<1 alone (both P<0.001). The combined models showed no significant improvement over UCI or pitch value alone (both P>0.05), though both were superior to CPR<1 alone (both P<0.001).
CONCLUSIONS
Most umbilical cord hypercoiling cases had favorable outcomes, with UCI, pitch value, CPR<1 and their combinations demonstrating significant predictive value for adverse pregnancy outcomes.
Humans
;
Female
;
Pregnancy
;
Pregnancy Outcome
;
Adult
;
Ultrasonography, Prenatal/methods*
;
Umbilical Cord/diagnostic imaging*
;
Hemodynamics
;
Predictive Value of Tests
;
Infant, Newborn
;
ROC Curve
3.Advancements in molecular imaging probes for precision diagnosis and treatment of prostate cancer.
Jiajie FANG ; Ahmad ALHASKAWI ; Yanzhao DONG ; Cheng CHENG ; Zhijie XU ; Junjie TIAN ; Sahar Ahmed ABDALBARY ; Hui LU
Journal of Zhejiang University. Science. B 2025;26(2):124-144
Prostate cancer is the second most common cancer in men, accounting for 14.1% of new cancer cases in 2020. The aggressiveness of prostate cancer is highly variable, depending on its grade and stage at the time of diagnosis. Despite recent advances in prostate cancer treatment, some patients still experience recurrence or even progression after undergoing radical treatment. Accurate initial staging and monitoring for recurrence determine patient management, which in turn affect patient prognosis and survival. Classical imaging has limitations in the diagnosis and treatment of prostate cancer, but the use of novel molecular probes has improved the detection rate, specificity, and accuracy of prostate cancer detection. Molecular probe-based imaging modalities allow the visualization and quantitative measurement of biological processes at the molecular and cellular levels in living systems. An increased understanding of tumor biology of prostate cancer and the discovery of new tumor biomarkers have allowed the exploration of additional molecular probe targets. The development of novel ligands and advances in nano-based delivery technologies have accelerated the research and development of molecular probes. Here, we summarize the use of molecular probes in positron emission tomography (PET), single-photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), optical imaging, and ultrasound imaging, and provide a brief overview of important target molecules in prostate cancer.
Humans
;
Male
;
Prostatic Neoplasms/diagnosis*
;
Molecular Probes
;
Molecular Imaging/methods*
;
Magnetic Resonance Imaging
;
Positron-Emission Tomography
;
Tomography, Emission-Computed, Single-Photon
;
Ultrasonography
;
Optical Imaging
;
Biomarkers, Tumor
;
Precision Medicine/methods*
4.Interventional endosonography comes of age: an update on endoscopic ultrasonography-guided drainage and anastomosis procedures.
Tiing Leong ANG ; Christopher Jen Lock KHOR
Singapore medical journal 2025;66(8):420-425
Endoscopic ultrasonography (EUS) has progressed beyond diagnostic imaging to include EUS-guided tissue acquisition and EUS-directed therapies. This review provides an update on EUS-guided drainage and anastomotic procedures, and other therapeutic procedures. Today, EUS-guided drainage of symptomatic walled-off pancreatic fluid collections is the norm, with endoscopic necrosectomy as an adjunct. For high-risk surgical patients unsuitable for cholecystectomy, EUS-guided gallbladder drainage of acute cholecystitis is an option. Additionally, EUS-guided drainage of obstructed biliary and pancreatic ductal system can be performed as salvage procedures after unsuccessful endoscopic retrograde cholangiopancreatography (ERCP). Bariatric procedures such as Roux-en-Y gastric bypass alter the gastric anatomy, hindering access to the major papilla. This can be overcome by creating a conduit through the excluded stomach using EUS-directed transgastric ERCP. Gastric outlet obstruction and afferent loop syndrome can be treated using EUS-guided gastrojejunostomy. These therapeutic interventions are a major advancement in the field of interventional EUS, achieving significant clinical impact.
Humans
;
Endosonography/methods*
;
Drainage/methods*
;
Cholangiopancreatography, Endoscopic Retrograde/methods*
;
Ultrasonography, Interventional/methods*
;
Anastomosis, Surgical/methods*
5.Effect of ultrasound-guided foraminal electroacupuncture on spinal cord injury based on the Wnt/β-catenin signaling pathway.
Weixian WU ; Bin CHEN ; Jing LIU ; Li WANG ; Feizhen CHEN ; Yanling WU
Chinese Acupuncture & Moxibustion 2025;45(10):1442-1449
OBJECTIVE:
To observe the effects of ultrasound-guided foraminal electroacupuncture on neuronal apoptosis and motor function in rats with spinal cord injury (SCI), and to explore the potential underlying mechanisms.
METHODS:
Thirty-six SPF-grade Sprague-Dawley rats were randomly assigned to a sham operation group, a model group, and an ultrasound-guilded electroacupuncture group (electroacupuncture group), with 12 rats in each group. In the sham operation group, the spinal cord was exposed and then the incision was sutured without contusion. In the other two groups, SCI models were established using a modified Allen's impact method. On days 1, 3, 7, and 14 after modeling, the electroacupuncture group received electroacupuncture intervention at the T9/T10 and T10/T11 intervertebral foramen under ultrasound guidance, avoiding spinal cord injury. Stimulation parameters were dense-disperse wave at 2 Hz/100 Hz and 1-2 mA for each session. Following interventions on days 1, 3, 7, and 14, the Basso-Beattie-Bresnahan (BBB) score was assessed; the inclined plane test was used to assess hindlimb grip strength in rats. After the intervention, HE staining was used to observe spinal cord morphology; TUNEL staining was used to detect neuronal apoptosis; ELISA was used to measure the serum levels of interleukin (IL)-6, IL-1β, and tumor necrosis factor-alpha (TNF-α); Western blot was used to analyze the protein expression of Wnt-4, β-catenin, c-Myc, Bax, Bcl-2, and NeuN in spinal tissue; quantitative real-time PCR was used to detect the mRNA expression of Wnt-4, β-catenin, c-Myc, Bax, Bcl-2, and NeuN.
RESULTS:
Compared with the sham operation group, the model group showed significantly reduced BBB scores (P<0.05), and reduced inclined plane angles (P<0.05) at all time points. Compared with the model group, the electroacupuncture group exhibited increased BBB scores on days 3, 7, and 14 (P<0.05), and higher inclined plane angles on days 1, 3, 7, and 14 (P<0.05). Compared with the sham operation group, the model group showed disorganized spinal cord structure with increased inflammatory cells and necrotic neurons, higher number of apoptotic neurons in spinal tissue (P<0.05), elevated serum IL-6, IL-1β, and TNF-α levels (P<0.05), increased protein and mRNA expression of Wnt-4, β-catenin, c-Myc, and Bax (P<0.05), and decreased protein and mRNA expression of Bcl-2 and NeuN in spinal tissue (P<0.05). Compared with the model group, the electroacupuncture group had fewer inflammatory cells and apoptotic neurons in spinal tissue (P<0.05), reduced serum IL-6, IL-1β, and TNF-α levels (P<0.05), increased protein and mRNA expression of Wnt-4, β-catenin, Bcl-2, and NeuN (P<0.05), and decreased protein and mRNA expression of c-Myc and Bax in spinal tissue (P<0.05).
CONCLUSION
Ultrasound-guided foraminal electroacupuncture could improve motor function in rats with SCI, potentially by regulating the expression of molecules related to the Wnt-4/β-catenin signaling pathway to inhibit neuronal apoptosis and inflammatory responses.
Animals
;
Electroacupuncture/methods*
;
Spinal Cord Injuries/physiopathology*
;
Rats, Sprague-Dawley
;
Rats
;
Wnt Signaling Pathway
;
Male
;
Humans
;
Female
;
beta Catenin/metabolism*
;
Apoptosis
;
Ultrasonography
;
Tumor Necrosis Factor-alpha/genetics*
;
Spinal Cord/metabolism*
6.A joint distillation model for the tumor segmentation using breast ultrasound images.
Hongjiang GUO ; Youyou DING ; Hao DANG ; Tongtong LIU ; Xuekun SONG ; Ge ZHANG ; Shuo YAO ; Daisen HOU ; Zongwang LYU
Journal of Biomedical Engineering 2025;42(1):148-155
The accurate segmentation of breast ultrasound images is an important precondition for the lesion determination. The existing segmentation approaches embrace massive parameters, sluggish inference speed, and huge memory consumption. To tackle this problem, we propose T 2KD Attention U-Net (dual-Teacher Knowledge Distillation Attention U-Net), a lightweight semantic segmentation method combined double-path joint distillation in breast ultrasound images. Primarily, we designed two teacher models to learn the fine-grained features from each class of images according to different feature representation and semantic information of benign and malignant breast lesions. Then we leveraged the joint distillation to train a lightweight student model. Finally, we constructed a novel weight balance loss to focus on the semantic feature of small objection, solving the unbalance problem of tumor and background. Specifically, the extensive experiments conducted on Dataset BUSI and Dataset B demonstrated that the T 2KD Attention U-Net outperformed various knowledge distillation counterparts. Concretely, the accuracy, recall, precision, Dice, and mIoU of proposed method were 95.26%, 86.23%, 85.09%, 83.59%and 77.78% on Dataset BUSI, respectively. And these performance indexes were 97.95%, 92.80%, 88.33%, 88.40% and 82.42% on Dataset B, respectively. Compared with other models, the performance of this model was significantly improved. Meanwhile, compared with the teacher model, the number, size, and complexity of student model were significantly reduced (2.2×10 6 vs. 106.1×10 6, 8.4 MB vs. 414 MB, 16.59 GFLOPs vs. 205.98 GFLOPs, respectively). Indeedy, the proposed model guarantees the performances while greatly decreasing the amount of computation, which provides a new method for the deployment of clinical medical scenarios.
Humans
;
Breast Neoplasms/diagnostic imaging*
;
Female
;
Ultrasonography, Mammary/methods*
;
Image Processing, Computer-Assisted/methods*
;
Algorithms
;
Neural Networks, Computer
;
Breast/diagnostic imaging*
7.Cross-modal hash retrieval of medical images based on Transformer semantic alignment.
Qianlin WU ; Lun TANG ; Qinghai LIU ; Liming XU ; Qianbin CHEN
Journal of Biomedical Engineering 2025;42(1):156-163
Medical cross-modal retrieval aims to achieve semantic similarity search between different modalities of medical cases, such as quickly locating relevant ultrasound images through ultrasound reports, or using ultrasound images to retrieve matching reports. However, existing medical cross-modal hash retrieval methods face significant challenges, including semantic and visual differences between modalities and the scalability issues of hash algorithms in handling large-scale data. To address these challenges, this paper proposes a Medical image Semantic Alignment Cross-modal Hashing based on Transformer (MSACH). The algorithm employed a segmented training strategy, combining modality feature extraction and hash function learning, effectively extracting low-dimensional features containing important semantic information. A Transformer encoder was used for cross-modal semantic learning. By introducing manifold similarity constraints, balance constraints, and a linear classification network constraint, the algorithm enhanced the discriminability of the hash codes. Experimental results demonstrated that the MSACH algorithm improved the mean average precision (MAP) by 11.8% and 12.8% on two datasets compared to traditional methods. The algorithm exhibits outstanding performance in enhancing retrieval accuracy and handling large-scale medical data, showing promising potential for practical applications.
Algorithms
;
Semantics
;
Humans
;
Ultrasonography
;
Information Storage and Retrieval/methods*
;
Image Processing, Computer-Assisted/methods*
8.Thyroid nodule segmentation method integrating receiving weighted key-value architecture and spherical geometric features.
Journal of Biomedical Engineering 2025;42(3):567-574
To address the high computational complexity of the Transformer in the segmentation of ultrasound thyroid nodules and the loss of image details or omission of key spatial information caused by traditional image sampling techniques when dealing with high-resolution, complex texture or uneven density two-dimensional ultrasound images, this paper proposes a thyroid nodule segmentation method that integrates the receiving weighted key-value (RWKV) architecture and spherical geometry feature (SGF) sampling technology. This method effectively captures the details of adjacent regions through two-dimensional offset prediction and pixel-level sampling position adjustment, achieving precise segmentation. Additionally, this study introduces a patch attention module (PAM) to optimize the decoder feature map using a regional cross-attention mechanism, enabling it to focus more precisely on the high-resolution features of the encoder. Experiments on the thyroid nodule segmentation dataset (TN3K) and the digital database for thyroid images (DDTI) show that the proposed method achieves dice similarity coefficients (DSC) of 87.24% and 80.79% respectively, outperforming existing models while maintaining a lower computational complexity. This approach may provide an efficient solution for the precise segmentation of thyroid nodules.
Thyroid Nodule/diagnostic imaging*
;
Humans
;
Ultrasonography/methods*
;
Algorithms
;
Image Processing, Computer-Assisted/methods*
;
Thyroid Gland/diagnostic imaging*
9.Research progress on deep learning-based computer-aided diagnosis of thyroid nodules using ultrasound imaging.
Xinyuan ZHOU ; Min QIU ; Jiangfeng SHANG ; Guohui WEI
Journal of Biomedical Engineering 2025;42(5):1069-1075
Thyroid nodules are a common endocrine disorder, and their early detection and accurate diagnosis are crucial for the prevention of thyroid cancer. However, the highly heterogeneous morphology and boundaries of thyroid nodules pose significant challenges to their precise identification and classification. Traditional diagnostic approaches rely heavily on physicians' experience, which increases the risk of misdiagnosis and missed diagnoses. With the rapid advancement of computer-aided diagnosis (CAD) technologies, applying deep learning algorithms to the analysis of thyroid nodule ultrasound images has shown great potential. This paper reviews the latest research progress on deep learning-based CAD methods for thyroid nodules, with a focus on their applications in image preprocessing, segmentation and classification. The advantages and limitations of current techniques are analyzed, and potential future directions are discussed. This review aims to highlight the potential of deep learning in thyroid nodule diagnosis and to provide a foundation for selecting feasible pathways for future clinical applications.
Humans
;
Thyroid Nodule/diagnostic imaging*
;
Deep Learning
;
Ultrasonography/methods*
;
Diagnosis, Computer-Assisted/methods*
;
Algorithms
;
Thyroid Neoplasms/diagnostic imaging*
;
Image Processing, Computer-Assisted/methods*
10.A comparative study of color Doppler ultrasound and CT angiography for preoperative evaluation of perforator vessels in free posterior interosseous artery flap.
Hongquan WANG ; Shanshan LIU ; Yingzhi XIE ; Haoliang HU ; Miaozhong LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):483-487
OBJECTIVE:
To investigate the accuracy of color Doppler ultrasound (CDU) and CT angiography (CTA) in the preoperative evaluation of perforator vessels in free posterior interosseous artery perforator (PIAP) flaps.
METHODS:
Between January 2020 and December 2023, 19 patients with hand skin and soft tissue defects caused by trauma were admitted. There were 11 males and 8 females, with a median age of 45 years (range, 26-54 years). The interval between injury and admission was 5-11 days (mean, 7.2 days). The skin and soft tissue defects were located on the dorsum of the hand in 8 cases and on the fingers in 11 cases. The size of defect ranged from 4.0 cm×2.5 cm to 7.5 cm×3.5 cm. After locating the perforator vessels through CDU and CTA before operation, the free PIAP flaps were designed to repair hand defects, with the size of 4.5 cm×3.0 cm-7.5 cm×4.0 cm. The defects of donor sites were directly sutured. The number and diameter of perforator vessels in the posterior interosseous artery detected by CDU and CTA were compared. The differences in localization of perforator vessels using CDU and CTA and their clinical effects were also compared to calculate the accuracy and recognition rate. During follow-up, the survival of the skin flap was observed, and the Vancouver scar scale (VSS) score was used to evaluate the healing of the donor site, while the visual analogue scale (VAS) score was used to evaluate the patient's satisfaction with the appearance of the skin flap.
RESULTS:
The number and the diameter of PIAP vessels was 5.8±1.2 and (0.62±0.08) mm assessed by CDU and 5.2±1.0 and (0.60±0.07) mm by CTA, showing no significant difference between the two methods ( P>0.05). The number, course, and distribution of perforator vessels of the PIAP vessels observed during operation were basically consistent with those detected by preoperative CDU and CTA. Compared with intraoperative observation results, the recognition rates of dominant perforating vessels by CDU and CTA were 95.0% (18/19) and 89.5% (17/19), respectively, and the accuracy rates were 100% (19/19) and 84.2% (16/19), with no significant difference between the two methods ( P>0.05). All flaps survived after operation, and all wounds and incisions at donor sites healed by first intention. All patients were followed up 6-13 months (mean, 8.2 months). At last follow-up, the skin flaps had elasticity and soft texture,with the patient satisfaction VAS score of 9.2±0.8. The donor sites had no obvious scar hyperplasia with the VSS score of 11.7±0.9.
CONCLUSION
CDU and CTA accurately identify the dominant perforator vessels and provide reliable information for vessel localization, facilitating precise flap harvesting and minimizing donor site injury. However, CDU offers superior visualization of distal end of perforator vessels in the forearm compared to CTA.
Humans
;
Female
;
Male
;
Adult
;
Perforator Flap/blood supply*
;
Middle Aged
;
Ultrasonography, Doppler, Color/methods*
;
Computed Tomography Angiography/methods*
;
Soft Tissue Injuries/diagnostic imaging*
;
Hand Injuries/diagnostic imaging*
;
Plastic Surgery Procedures/methods*
;
Hand/surgery*
;
Preoperative Care
;
Arteries/diagnostic imaging*

Result Analysis
Print
Save
E-mail