1.Ultrasound-guided needle knife release with different pathways for carpal tunnel syndrome: a randomized controlled trial.
Zhaobao LI ; Song HE ; Longyu XIE ; Hehuizi BAI ; Dejun CHENG ; Wenchao ZHANG ; Mingyong HUANG
Chinese Acupuncture & Moxibustion 2025;45(1):21-26
OBJECTIVE:
To evaluate the clinical efficacy of ultrasound-guided needle knife release with different pathways for carpal tunnel syndrome (CTS).
METHODS:
Sixty CTS patients were randomly divided into a transverse group and a longitudinal group, with 30 patients in each group. The transverse group received the needle knife release under ultrasound above and below the median nerve along the short axis, while the longitudinal group received the needle knife release under ultrasound above the median nerve along the long axis. The patients' visual analogue scale (VAS) scores, Levine scores, and median nerve cross-section area (CSA) were assessed before treatment, on the 7th, 14th, and 30th days after treatment. The median nerve conduction indexes (motor conduction: latency [Lat], amplitude[Amp], motor conduction velocity [MCV]; sensory conduction: Lat, Amp, sensory conduction velocity [SCV]) were evaluated before treatment and on the 30th day after treatment.
RESULTS:
Compared before treatment, the VAS scores, Levine scores, and median nerve CSA were reduced in both groups on the 7th, 14th, and 30th days after treatment (P<0.05); the transverse group showed lower VAS and Levine scores and smaller CSA than those in the longitudinal group (P<0.05). On the 30th day after treatment, motor and sensory Lat was reduced (P<0.05), motor and sensory Amp was increased (P<0.05), and MCV and SCV were faster (P<0.05) in both groups. The transverse group had shorter Lat, higher Amp, and faster MCV and SCV than those in the longitudinal group (P<0.05).
CONCLUSION
The ultrasound-guided needle knife release with transverse and longitudinal pathways could both effectively alleviate pain and improve median nerve conduction in CTS patients, with the transverse pathway showing superior efficacy to longitudinal pathway.
Humans
;
Carpal Tunnel Syndrome/therapy*
;
Female
;
Middle Aged
;
Male
;
Adult
;
Median Nerve/physiopathology*
;
Acupuncture Therapy/instrumentation*
;
Treatment Outcome
;
Neural Conduction
;
Aged
;
Ultrasonography
2.Ultrasound-guided closed reduction and internal fixation using Kirschner wire for the treatment of olecranon fractures of the ulna in children.
Deng-Shan CHEN ; Chuan-Wei ZHANG ; Lei WANG ; Xing-Po DING ; Jian-Ping YANG
China Journal of Orthopaedics and Traumatology 2025;38(7):743-746
OBJECTIVE:
To investigate the clinical efficacy and safety of ultrasound-guided closed reduction and internal fixation using Kirschner wire for the treatment of olecranon fractures of the ulna in children.
METHODS:
Between January 2019 and January 2021, 13 children with olecranon fracture were treated with ultrasound-guided closed reduction and percutaneous Kirschner wire internal fixation, including 10 males and 3 females. The age ranged from 3 to 14 years old. Children with ulnar olecranon fractures were evaluated using the Gicquel scoring system. The clinical evaluation encompassed postoperative pain, functional status, and range of motion, with a maximum score of 15 points. The radiological assessment contributed an additional 4 points. A cumulative score of more than 18 scores was classified as excellent, more than 17 scores as good, more than16 scores as fair, and less than 16 scores as poor. Clinical assessment:A score of 14 indicates excellent performance, a score of 13 reflects good performance, a score of 12 denotes fair performance, and a score of less than 11 signifies poor performance.
RESULTS:
A total of 13 patients were followed up, with a duration ranging from 6 to 12 months. According to the Gicquel scoring criteria, the comprehensive evaluation of clinical and radiographic findings yielded 10 excellent and 3 good outcomes. Evaluation based solely on clinical findings resulted in 13 excellent outcomes.
CONCLUSION
Ultrasound-guided percutaneous cross Kirschner wire fixation for children's olecranon fracture has the advantages of less trauma, rapid recovery, less fluoroscopy, and good recovery of elbow function. The clinical effect is satisfactory.
Humans
;
Child
;
Male
;
Female
;
Fracture Fixation, Internal/instrumentation*
;
Ulna Fractures/physiopathology*
;
Bone Wires
;
Child, Preschool
;
Adolescent
;
Olecranon Process/surgery*
;
Ultrasonography
;
Closed Fracture Reduction/methods*
;
Olecranon Fracture
3.Performance Testing of Medical Ultrasound Diagnostic Equipment Based on Tissue-Mimicking Phantom.
Hao LIU ; Longyang JIA ; Ruiyao JIANG
Chinese Journal of Medical Instrumentation 2025;49(3):308-312
This study aims to ensure the effectiveness of medical ultrasound diagnostic equipment in clinical applications by testing multiple key performance indicators using tissue-mimicking phantoms and exploring the changes in these performance indicators over time. Firstly, 17 in-service medical ultrasound diagnostic equipments were selected, and their depth of penetration, dead zone, lateral resolution, axial resolution, geometric position error, and cystic focal diameter error were tested according to the verification regulations. In addition, the study retrospectively analyzed the performance testing data of 19 medical ultrasound diagnostic equipments over the past three consecutive years and conducted statistical analysis. Through the testing, all performance indicators of the 17 equipments met the requirements of the verification regulations, indicating that they can stably and reliably provide high-quality ultrasound diagnostic images and data in clinical applications. Meanwhile, retrospective data showed that with the increase with the increase in service life, the resolving ability at the far field of the 19 equipments decreased, and the cystic focal diameter error increased. Therefore, it is recommended that medical institutions establish a regular testing and maintenance system for medical ultrasound diagnostic equipment, conducting regular performance evaluations and maintenance to ensure its good working condition.
Phantoms, Imaging
;
Ultrasonography/instrumentation*
;
Retrospective Studies
4.Development of Synchronous Arbitrary Gate-PW Doppler for Ultrasound Microvascular Imaging and Preliminary Validation.
Chao LI ; Lanxi XIANG ; Yigang DU ; Zhilan ZHENG ; Shuangshuang LI
Chinese Journal of Medical Instrumentation 2025;49(4):355-362
Ultra micro angiography (UMA) can effectively improve the sensitivity and spatial resolution of blood flow imaging. To further meet the clinical requirements of quantitative measurements for microvascular imaging, this article demonstrated technical features and performance verification results of the microflow quantitative analysis function, which was developed based on the UMA function. This article provided preliminary validation of the measurement of Synchronous Arbitrary Gate-PW (SAG-PW) using a Doppler flow phantom and a moving string phantom. The Doppler flow phantom results demonstrated that the SAG-PW measurement values were close to the traditional PW results, and the average error of multiple sets of measurement results under different conditions was 3.9%. The results of SAG-PW and PW were strongly linearly correlated, with the slope and correlation coefficient approaching 1. The results of the moving string phantom demonstrated that the relative errors of TAMean and SAG-PW with different phantom set values were within 10%.
Phantoms, Imaging
;
Ultrasonography, Doppler/instrumentation*
;
Microvessels/diagnostic imaging*
5.Ultrafast Imaging of Coherent Plane-wave Compouding Based on a Small Size Ultrasound Transducer.
Yujia TANG ; Yaoyao CUI ; Zhangjian LI ; Chen YANG ; Liming CAI ; Jiabing LYU ; Yang JIAO
Chinese Journal of Medical Instrumentation 2019;43(5):313-317
The ultrasound endoscopic probes with very small size transducers are normally imaging by focused ultrasound beamforming technology. So the imaging frame rate is not very high, which cannot meet the needs of some clinical applications based on high imaging rate. In recent years, plane-wave ultrafast imaging technology can obtain high image frame rate and guarantee the image quality. In this paper, a plane wave ultra-fast imaging technique based on a home-made small line array ultrasound transducer is presented. Feasibility of the method is verified by simulation estimations and phantom experiments. The results show that for the small size transducer design of plane wave ultrafast imaging, it is necessary to fully consider the combination of the array element width and the number of array elements. So that a good plane wave imaging quality can be obtained. It lays a foundation for the ultra-fast imaging of plane wave in the interventional ultrasound imaging and ultrasound endoscopy.
Phantoms, Imaging
;
Transducers
;
Ultrasonography
;
instrumentation
6.Study on a New Ultraviolet Sterilizer to the Surface Disinfection of the Ultrasound Probe.
Gui Qiu CHEN ; Yu Hao CHEN ; Liang YI ; Jin YIN ; Qiong GAO ; Jiang Nan SONG ; Shi Kang LI ; Pei Hou CHEN ; Gui Ping GUO
Biomedical and Environmental Sciences 2018;31(2):163-167
We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance influence tests were used to carry out experimental observation. Artificially infected probes were disinfected using the sterilizer or a germicidal lamp for comparison. The total number and types of bacteria were determined and identified. Our results demonstrated the sterilizer had the best disinfection effect among three different disinfection methods in hospital. The sterilizer has been used in a hospital setting for 2 years with no notable damage to the ultrasound probe instrument. It has the advantages of fast disinfection, high disinfection effect, and good compatibility with the ultrasound instrument, worthy of being a promoted application in medical institutions.
Bacterial Infections
;
microbiology
;
prevention & control
;
Colony Count, Microbial
;
Cross Infection
;
microbiology
;
prevention & control
;
Disinfection
;
instrumentation
;
methods
;
Equipment Contamination
;
prevention & control
;
Sterilization
;
instrumentation
;
Surface Properties
;
Ultrasonography
;
instrumentation
;
Ultraviolet Rays
7.One-puncture one-needle TRUS-guided prostate biopsy for prevention of postoperative infections.
Xiao-Fu QIU ; Guo-Sheng YANG ; Bo-Te CHEN ; Li MA
National Journal of Andrology 2017;23(7):630-634
Objective:
To explore the feasibility and effectiveness of "one-puncture one-needle" transrectal ultrasound (TRUS)-guided prostate biopsy in the prevention of postoperative infections.
METHODS:
We retrospectively analyzed the clinical data about "one-puncture one-needle" (the observation group) and "one-person one-needle" (the control group) TRUS-guided prostate biopsy performed in the Second People's Hospital of Guangdong Province from January 2005 to December 2015, and compared the incidence rates of puncture-related infection between the two strategies. By "one-puncture one-needle", one needle was used for one biopsy puncture, while by "one-person one-needle", one needle was used for all biopsy punctures in one patient and the needle was sterilized with iodophor after each puncture.
RESULTS:
Totally, 120 patients received 6+1-core or 12+1-core "one-person one-needle" and 466 underwent 12+1-core "one-puncture one-needle" TRUS-guided prostate biopsy. There were no statistically significant differences between the two groups of patients in age, the prostate volume, the serum PSA level, or the detection rate of prostate cancer (P >0.05). Compared with the control group, the observation group showed remarkably lower incidence rates of puncture-related urinary tract infection (7.5% vs 0.9%, P <0.05), fever (5.0% vs 1.1%, P <0.05), bacteriuria (2.5% vs 0.2%, P <0.05), and total infections (16.7% vs 2.6%, P<0.05) postoperatively. Two cases of bacteremia or sepsis were found in each of the groups, with no significant difference between the two.
CONCLUSIONS
"One-puncture one-needle" TRUS-guided prostate biopsy can effectively prevent puncture-related infections.
Bacteremia
;
etiology
;
Biopsy, Fine-Needle
;
adverse effects
;
instrumentation
;
methods
;
Case-Control Studies
;
Feasibility Studies
;
Humans
;
Male
;
Prostate
;
pathology
;
Prostate-Specific Antigen
;
blood
;
Prostatic Neoplasms
;
blood
;
pathology
;
Retrospective Studies
;
Sterilization
;
methods
;
Ultrasonography, Interventional
;
Urinary Tract Infections
;
prevention & control
8.Retrospective Analysis of Ultrasound-guided Flexible Ureteroscopy in the Management of Calyceal Diverticular Calculi.
Ji-Qing ZHANG ; Yong WANG ; Jun-Hui ZHANG ; Xiao-Dong ZHANG ; Nian-Zeng XING
Chinese Medical Journal 2016;129(17):2067-2073
BACKGROUNDPercutaneous nephrolithotomy (PCNL) is the most widely recommended treatment for calyceal diverticular calculi, providing excellent stone-free results. However, its invasiveness is not negligible considering its major complication rates. Flexible ureteroscopy (FURS) is currently used to treat calyceal diverticula. However, the greatest drawback of FURS is locating the diverticulum since its neck is narrow and concealed. In such a case, the FURS procedure must be converted to PCNL. The aim of this study was to evaluate ultrasound-guided flexible ureteroscopy (UFURS) identifying diverticulum and the management of calyceal diverticular calculi.
METHODSA retrospective analysis was conducted on 24 patients who had calyceal diverticular calculi. In all 12 patients in the UFURS group, direct FURS failed to find evidence of calyceal diverticula but were confirmed with imaging. The other 12 patients in the PCNL group received PCNL plus fulguration of the diverticular walls.
RESULTSPuncture of calyceal diverticulum was successful in all 12 UFURS patients. Two patients in this group had postoperative residual calculi and two patients developed fever. In the PCNL group, percutaneous renal access and lithotomy were successful in all 12 patients. One patient in this group had residual calculi, one had perirenal hematoma, and two patients developed fever. No significant difference was found in the operating time (UFURS vs. PCNL, 91.8 ± 24.2 vs. 86.3 ± 18.7 min), stone-free rate (UFURS vs. PCNL, 9/12 vs. 10/12), and rate of successful lithotripsy (UFURS vs. PCNL, 10/12 vs. 11/12) between the two groups (all P> 0.05). Postoperative pain scores in the FURS group were significantly lower than that in the PCNL group (2.7 ± 1.2 vs. 6.2 ± 1.5, P< 0.05). Hospital stay in the UFURS group was significantly shorter than that in the PCNL group (3.4 ± 0.8 vs. 5.4 ± 1.0 days, P< 0.05). All patients were symptom-free following surgery (UFURS vs. PCNL, 10/10 vs. 12/12).
CONCLUSIONUltrasound-guided puncture facilitates identification of calyceal diverticula during FURS and improves the success rate of FURS surgery.
Adult ; Diverticulum ; diagnosis ; surgery ; Female ; Humans ; Kidney Calculi ; diagnosis ; surgery ; Male ; Middle Aged ; Retrospective Studies ; Ultrasonography ; methods ; Ureteroscopes ; Ureteroscopy ; instrumentation ; methods
9.Assessment of Factors Affecting the Usefulness and Diagnostic Yield of Core Biopsy Needles with a Side Hole in Endoscopic Ultrasound-Guided Fine-Needle Aspiration.
Tadahisa INOUE ; Fumihiro OKUMURA ; Takashi MIZUSHIMA ; Hirotada NISHIE ; Hiroyasu IWASAKI ; Kaiki ANBE ; Takanori OZEKI ; Kenta KACHI ; Shigeki FUKUSADA ; Yuta SUZUKI ; Hitoshi SANO
Gut and Liver 2016;10(1):51-57
BACKGROUND/AIMS: A barbed puncture needle with a side hole was recently developed to improve sample quality and quantity in endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). In this study, we retrospectively assessed the usefulness of this puncture needle. METHODS: Factors affecting diagnostic yield, safety, and diagnostic accuracy were investigated in 76 patients who consecutively underwent EUS-FNA for neoplastic lesions at our hospital between January and December 2013. RESULTS: The procedure was successful in all cases; the rates of sample collection and determination of the correct diagnosis were 92.1% and 89.5%, respectively. The mean number of needle passes required for diagnosis was 1.1. Complications included mild intraluminal bleeding in two patients (2.6%). Multivariate analysis revealed that lesion size (< or =20 mm) was significantly associated with a decreased chance of determining the correct diagnosis. CONCLUSIONS: Core biopsy needles with a side hole are safe and provide a satisfactory diagnostic yield. However, the side hole may potentially reduce the rate of making the correct diagnosis in small lesions.
Adult
;
Aged
;
Aged, 80 and over
;
Digestive System Neoplasms/*diagnosis/ultrasonography
;
Endoscopic Ultrasound-Guided Fine Needle Aspiration/*instrumentation
;
Equipment Design
;
Equipment Safety
;
Female
;
Gastrointestinal Tract/pathology/ultrasonography
;
Humans
;
Male
;
Middle Aged
;
Multivariate Analysis
;
Needles/adverse effects/*statistics & numerical data
;
Predictive Value of Tests
;
Retrospective Studies
;
Sensitivity and Specificity
;
Statistics, Nonparametric
10.Research on Shielding of Emboli with the Phase-Controlled Ultrasound.
Chinese Journal of Medical Instrumentation 2016;40(1):1-4
The postoperative neurological complications is associated with intraoperative cerebral emboli, which results from extracorporeal circulation and operation. It can effectively reduce the incidence of neurological complications with ultrasonic radiation. In fluids, a particle will change it's motion trail when it is acted by the radiation force generated by the ultrasound. This article mainly discuss how to shielding emboli with ultrasound. The equipment can transmit phased ultrasonic signals, which is designed on a FPGA development board. The board can generate a square wave, which is converted into a sine wave through a power amplifier. In addition, the control software has been developed on Qt development environment. The result indicates it's feasible to shielding emboli with ultrasonic radiation force. This article builds a strong foundation for the future research.
Humans
;
Intracranial Embolism
;
diagnostic imaging
;
prevention & control
;
Intraoperative Complications
;
prevention & control
;
Postoperative Complications
;
prevention & control
;
Ultrasonics
;
instrumentation
;
Ultrasonography

Result Analysis
Print
Save
E-mail