1.Wrist arthroscopic Wafer surgery combined with triangular fibrocartilage complex insertion point reconstruction in treatment of Palmer type ⅡC combined with type ⅠB ulnar impingement syndrome.
Yong LI ; Mingming MA ; Xiaojun RUAN ; Yongbin FU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):59-63
OBJECTIVE:
To investigate the effectivess of arthroscopic Wafer surgery combined with triangular fibrocartilage complex (TFCC) insertion point reconstruction in the treatment of Palmer type ⅡC combined with typeⅠB ulnar impingement syndrome.
METHODS:
The clinical data of 14 patients with Parlmer type ⅡC combined with type ⅠB ulnar impingement syndrome who met the selection criteria between July 2021 and April 2024 were retrospectively analyzed. There were 7 males and 7 females with an average age of 43 years ranging from 16 to 59 years. The causes of injury were fall in 8 cases and sprain in 6 cases. The time from injury to operation ranged from 1 to 6 months, with an average of 2.3 months. Distal radioulnar joint instability was found in all cases. Arthroscopic Wafer surgery combined with TFCC insertion point reconstruction was used. The effectiveness was evaluated by comparing the wrist flexion-dorsiflexion range of motion, wrist ulnar deviation-radial deflection range of motion, forearm pronation-supination range of motion, visual analogue scale (VAS) score, and modified Mayo wrist score before and after operation.
RESULTS:
All patients were followed up 6-12 months, with an average of 9.1 months. The positive variation of ulna was (3.2±0.7) mm before operation, and the negative variation of ulna was (2.2±0.6) mm after operation. There was a significant difference in ulna variation between pre- and post-operation ( t=23.851, P<0.001). The pain symptoms and forearm rotation function of the patients after operation significantly improved. At last follow-up, the wrist flexion-dorsiflexion range of motion, wrist ulnar deviation-radial deflection range of motion, forearm pronation-supination range of motion, VAS score, and modified Mayo wrist score significantly improved when compared with those before operation ( P<0.05).
CONCLUSION
Arthroscopic Wafer surgery combined with TFCC insertion point reconstruction can effectively relieve wrist pain, enhance the stability of the distal radioulnar joint, and restore the function of the wrist in patients with Palmer type ⅡC combined with type ⅠB ulnar impingement syndrome.
Humans
;
Male
;
Adult
;
Arthroscopy/methods*
;
Female
;
Triangular Fibrocartilage/surgery*
;
Middle Aged
;
Range of Motion, Articular
;
Retrospective Studies
;
Wrist Joint/physiopathology*
;
Adolescent
;
Young Adult
;
Ulna/surgery*
;
Treatment Outcome
;
Wrist Injuries/surgery*
;
Plastic Surgery Procedures/methods*
;
Joint Instability/surgery*
2.Antegrade elastic intramedullary nailing fixation via a novel approach through proximal radius for distal radius metaphyseal-diaphyseal junction fractures in children.
Bin JIN ; Xinglei SHI ; Hailong MA ; Junchen ZHU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1155-1159
OBJECTIVE:
To investigate the surgical technique and preliminary effectiveness of closed reduction and internal fixation (CRIF) using antegrade elastic intramedullary nailing (ESIN) via a novel approach through the proximal radius for treating distal radius metaphyseal-diaphyseal junction (DRMDJ) fractures in children.
METHODS:
A retrospective analysis was conducted on 34 children with DRMDJ fractures who met the selection criteria and were treated between January 2020 and June 2023. There were 21 boys and 13 girls, aged 6-14 years (mean, 8.2 years). Injury causes included falls in 11 cases and sports-related trauma in 23 cases. Twenty-six cases were associated with ipsilateral distal ulnar fractures. All patients had failed initial closed reduction in the outpatient clinic. The time from injury to operation ranged from 1 to 15 days (mean, 4 days). All patients underwent CRIF using antegrade ESIN inserted via a novel approach at the proximal one-third of the radius. The operation time, intraoperative fluoroscopy frequency, fracture healing time, and complications were recorded. Fracture reduction was assessed immediately after operation on anteroposterior and lateral X-ray films for residual translation and angulation. Wrist function was evaluated using the modified Mayo wrist score.
RESULTS:
Surgery was successfully completed in all 34 children. CRIF with ESIN failed in 2 cases with associated ipsilateral distal ulnar fractures, requiring conversion to open reduction of the ulna. Operation time ranged from 15 to 56 minutes (mean, 21 minutes). Intraoperative fluoroscopy frequency ranged from 5 to 21 times (mean, 7 times). Immediate postoperative X-ray films showed residual translation of 0-15% on anteroposterior view and 0-10% on lateral view, and residual angulation of 0°-5° on both anteroposterior and lateral views. All children were followed up 6-18 months (mean, 12 months). There was no complication such as neurovascular injury, incision infection, or limitation of forearm rotation. Follow-up X-ray films showed no fracture displacement, implant loosening, delayed union, or nonunion. Fracture healing time ranged from 4 to 8 weeks (mean, 6 weeks). Implants were removed at 4-6 months postoperatively (mean, 5 months). At last follow-up, all fractures had achieved anatomic or near-anatomic healing. The modified Mayo wrist score ranged from 80 to 100 (mean, 94), with 27 excellent and 7 good results, yielding an excellent and good rate of 100%.
CONCLUSION
CRIF using antegrade ESIN via a novel approach through proximal radius is a safe and effective treatment for pediatric DRMDJ fractures, associated with few postoperative complications and excellent restoration of wrist function.
Humans
;
Child
;
Female
;
Male
;
Fracture Fixation, Intramedullary/instrumentation*
;
Adolescent
;
Radius Fractures/diagnostic imaging*
;
Retrospective Studies
;
Bone Nails
;
Treatment Outcome
;
Fracture Healing
;
Diaphyses/surgery*
;
Radius/surgery*
;
Operative Time
;
Closed Fracture Reduction/methods*
;
Ulna Fractures/surgery*
3.Ultrasound-guided closed reduction and internal fixation using Kirschner wire for the treatment of olecranon fractures of the ulna in children.
Deng-Shan CHEN ; Chuan-Wei ZHANG ; Lei WANG ; Xing-Po DING ; Jian-Ping YANG
China Journal of Orthopaedics and Traumatology 2025;38(7):743-746
OBJECTIVE:
To investigate the clinical efficacy and safety of ultrasound-guided closed reduction and internal fixation using Kirschner wire for the treatment of olecranon fractures of the ulna in children.
METHODS:
Between January 2019 and January 2021, 13 children with olecranon fracture were treated with ultrasound-guided closed reduction and percutaneous Kirschner wire internal fixation, including 10 males and 3 females. The age ranged from 3 to 14 years old. Children with ulnar olecranon fractures were evaluated using the Gicquel scoring system. The clinical evaluation encompassed postoperative pain, functional status, and range of motion, with a maximum score of 15 points. The radiological assessment contributed an additional 4 points. A cumulative score of more than 18 scores was classified as excellent, more than 17 scores as good, more than16 scores as fair, and less than 16 scores as poor. Clinical assessment:A score of 14 indicates excellent performance, a score of 13 reflects good performance, a score of 12 denotes fair performance, and a score of less than 11 signifies poor performance.
RESULTS:
A total of 13 patients were followed up, with a duration ranging from 6 to 12 months. According to the Gicquel scoring criteria, the comprehensive evaluation of clinical and radiographic findings yielded 10 excellent and 3 good outcomes. Evaluation based solely on clinical findings resulted in 13 excellent outcomes.
CONCLUSION
Ultrasound-guided percutaneous cross Kirschner wire fixation for children's olecranon fracture has the advantages of less trauma, rapid recovery, less fluoroscopy, and good recovery of elbow function. The clinical effect is satisfactory.
Humans
;
Child
;
Male
;
Female
;
Fracture Fixation, Internal/instrumentation*
;
Ulna Fractures/physiopathology*
;
Bone Wires
;
Child, Preschool
;
Adolescent
;
Olecranon Process/surgery*
;
Ultrasonography
;
Closed Fracture Reduction/methods*
;
Olecranon Fracture
4.Clinical characteristics and treatment analysis of three cases of congenital ulnar collateral flexor contracture of the forearm.
Yu ZHANG ; Qian XU ; Haijun MAO ; Shujuan WANG ; Xiaojuan SHENG ; Guangyue XU
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):51-55
OBJECTIVE:
To report the clinical characteristics and treatment analysis of 3 cases of congenital ulnar collateral flexor contracture of the forearm and take a reference for clinic.
METHODS:
A total of 3 patients with congenital ulnar collateral flexor contracture of the forearm were admitted between February 2019 and August 2021. Two patients were male and 1 was female, and their ages were 16, 20, and 16 years, respectively. The disease durations were 8, 20, and 15 years, respectively. They all presented with flexion deformity of the proximal and distal interphalangeal joints of the middle, ring, and little fingers in the neutral or extended wrist position, and the deformity worsened in the extended wrist position. The total action motion (TAM) scores of 3 patients were 1 and the gradings were poor. The Carroll's hand function evaluation scores were 48, 55, and 57, and the grip strength indexes were 72.8, 78.4, and 30.5. Preoperative CT of case 2 showed a bony protrusion of the flexor digitorum profundus tendon at the proximal end of the ulna; and MRI of case 3 showed that the ulnar flexor digitorum profundus presented as a uniform cord. After diagnosis, all patients were treated with operation to release the denatured tendon, and functional exercise was started early after operation.
RESULTS:
The incisions of 3 patients healed by first intention. Three patients were followed up for 12, 35, and 12 months, respectively. The hand function and the movement range of the joints significantly improved, but the grip strength did not significantly improve. At last follow-up, TAM scores were 3, 4, and 4, respectively, among which 2 cases were excellent and 1 case was good. Carroll's hand function evaluation scores were 95, 90, and 94, and the grip strength indexes were 73.5, 81.3, and 34.2, respectively.
CONCLUSION
Congenital ulnar collateral flexor contracture is a rare clinical disease that should be distinguished from ischemic muscle contracture. The location of the contracture should be identified and appropriate surgical timing should be selected for surgical release. Active postoperative rehabilitation and functional exercise can achieve good hand function.
Humans
;
Male
;
Female
;
Forearm/surgery*
;
Contracture/surgery*
;
Muscle, Skeletal
;
Tendons/surgery*
;
Ulna/surgery*
;
Range of Motion, Articular
5.Arthroscopic triangular fibrocartilage complex trimming combined with oblique osteotomy shortening of distal ulna for ulnar impact syndrome.
Xiao-Guang MENG ; Feng-Song XU ; Fu-Dong SHI
China Journal of Orthopaedics and Traumatology 2024;37(12):1180-1187
OBJECTIVE:
To explore clinical effect of arthroscopic modification of triangular fibrocartilage complex (TFCC) combined with oblique osteotomy shortening of distal ulna in treating ulna impact syndrome.
METHODS:
A retrospective analysis was performed on 49 patients with ulnar impingement syndrome admitted from 2017 to 2021, 3 patients were lost to follow-up, and 46 patients were finally included in study, including 23 males and 23 females, aged from 21 to 53 years old with an average of (36.5±3.3) years old. The patients were divided into TFCC group and control group according to different operation methods. Twenty-four patients in TFCC group, including 13 males and 11 females, aged from 21 to 53 years old with an average of (36.5±3.2) years old;10 patients on the left side and 14 patients on the right side;arthroscopic TFCC trimming combined with oblique osteotomy shortening of distal ulna was performed. Twenty-two patients in control group, including 10 males, 12 females, aged from 21 to 53 years old with an average of (36.5±3.3) years old;13 patients on the left side, 9 patients on the right side; oblique osteotomy of distal ulna was performed. Operative time, hospital stay, intraoperative bleeding and osteotomy healing time between two groups were observed and compared. Cooney wrist function score and visual analogue scale (VAS) were used to evaluate improvement of wrist function and pain before and 12 months after operation, respectively. The variation values of ulna and grip strength were compared.
RESULTS:
The follow-up time of TFCC group ranged from 12 to 21 months with an average of (15.10±2.67) months, and that of control group ranged from 12 to 20 months with an average of (15.06±2.81) months, there was no statistical significance between two groups (P>0.05). Operative time, osteotomy healing time, intraoperative bleeding and hospital stay in TFCC group were (68.51±13.50) min, (16.21±1.16) weeks, (25.13±4.22) ml and (7.35±1.20) d, respectively;while control group were (45.65±5.64) min, (17.46±2.06) weeks, (24.61±5.10) ml and (7.51±1.13) d, respectively; there were statistically significant differences in operative time and osteotomy healing time between two groups (P<0.05). There were no significant differences in intraoperative bleeding and hospital stay between two groups(P>0.05). There were no significant differences in total score and scores of Cooney wrist joint function between two groups before operation(P>0.05). Pain, functional status, range of motion, grip strength and Cooney wrist function score in TFCC group were higher than those in control group at 12 months after operation (P<0.05). According to Cooney wrist joint function score at 12 months after operation, 16 patients got excellent results, 6 good, and 2 fair in TFCC group; while 7 excellent, 11 good and 4 fair in control group;there was no significant difference between two groups (P>0.05). However, the proportion of wrist function recovery in TFCC group was higher than that in control group (P>0.05). At 12 months after operation, VAS of TFCC group (3.41±0.16) was lower than that of control group(3.52±0.13), P<0.005. There was no significant difference in ulnar variation between TFCC group and control group(P>0.05). The grip strength of TFCC group (93.6±10.1) % was better than that of control group (83.5±10.3) % (P<0.005).
CONCLUSION
Compared with oblique osteotomy shortening of distal ulna, TFCC trimming combined with oblique osteotomy shortening of distal ulna took longer to treat ulna collision syndrome, but the osteotomy healing time was shortened and wrist joint function was improved, especially pain, ulna variation, grip strength and motion were significantly improved.
Humans
;
Male
;
Female
;
Adult
;
Triangular Fibrocartilage/surgery*
;
Osteotomy/methods*
;
Ulna/surgery*
;
Middle Aged
;
Arthroscopy/methods*
;
Retrospective Studies
;
Young Adult
6.Analysis of the effectiveness of sequential plate internal fixation in correction of Madelung deformity after ulnar osteotomy and shortening.
Wei WANG ; Xiaowen DENG ; Wenbo LI ; Miaomiao YANG ; Yaqiang ZHANG ; Peisheng SHI ; Weiwei SHEN ; Rui LIU ; Jie SHI ; Chuangbing LI ; Yun XUE ; Qiuming GAO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):810-814
OBJECTIVE:
To investigate the effectiveness of sequential plate internal fixation in the correction of Madelung deformity after ulnar osteotomy and shortening.
METHODS:
The clinical data of 13 patients with Madelung deformity admitted between September 2015 and July 2021 were retrospectively analyzed. There were 5 males and 8 females with an average age of 18.3 years ranging from 17 to 23 years. The disease duration ranged from 12 to 24 months, with an average of 17 months. Three cases had a clear history of trauma. All patients had external radial deviation deformity and limited movement of the ulnar deviation, and the ulnar impact pain was significant during ulnar deviation movement; 9 patients had limited wrist joint supination movement, and the supination movement was normal. In the first stage, ulnar osteotomy and shortening combined with external fixator were used to correct wrist deformity in 13 patients. After operation, bone transfer was performed 6 times per day, with adjustments made every 4 hours, which was 1 mm per day. After the osteotomy was in place, the ulnar plate internal fixation was performed to reconstruct the ulnar stability in the second stage. The Cooney wrist joint score was used to assess the pain, function, range of motion, flexion and extension range of motion, and grip strength of the wrist joint before operation and before the removal of internal fixator. The subjective feeling and appearance satisfaction of patients were recorded.
RESULTS:
After the second-stage operation, all the 13 patients were followed up 10-22 months, with an average of 15 months. The deformity of wrist joint disappeared after operation, and the flexion, extension, and ulnar deviation were basically normal. There was no complication such as ulnar impingement sign, nonunion or infection. Wrist function, pain, and range of motion were significantly improved after operation, except for 1 patient who had no significant improvement in rotation and pain. The ulnar internal fixator was removed at 10-18 months after the second-stage operation. The scores of pain, function, range of motion, flexion and extension range of motion, and grip strength in the Cooney wrist score before removal of internal fixator significantly improved when compared with those before operation ( P<0.05). Subjective and appearance satisfaction of patients were excellent in 9 cases, good in 3 cases, and fair in 1 case.
CONCLUSION
Ulnar osteotomy and shortening with sequential plate internal fixation for correction of Madelung deformity, with mild postoperative pain, can effectively avoid bone nonunion, improve wrist joint function, and have significant effectiveness.
Male
;
Female
;
Humans
;
Adolescent
;
Retrospective Studies
;
Ulna/surgery*
;
Osteochondrodysplasias
;
Radius Fractures/surgery*
;
Wrist Joint/surgery*
;
Osteotomy
;
Range of Motion, Articular
;
Treatment Outcome
7.Comparison of the efficacy of three types of Kirschner wire tension bands for ulnar olecranal fracture.
Jia-Ru CHEN ; Zhe-Fei MOU ; Jun-Ju ZHENG
China Journal of Orthopaedics and Traumatology 2023;36(7):607-613
OBJECTIVE:
To compare the clinical effect of three types of Kirschner wire tension band for olecranon fracture.
METHODS:
The clinical data of 64 patients with olecranon fracture treated by Kirschner wire tension band fixation from March 2016 to May 2020 were retrospectively analyzed. Among them, 19 patients were treated with intramedullary K-wires fixation(group A) including 8 males and 11 females with an average of (48.2±18.3) years old, 3 patients were typeⅠ, and 16 patients were typeⅡ according to Mayo classification;20 patients were treated with transcortical K-wires fixation (group B) including 13 males and 7 females with an average of (43.5±20.4) years old, 3 patients were typeⅠand 17 patients were typeⅡ according to Mayo classification;25 patients were treated with perforated Kirschner wire(group C) including 15 males and 10 females with an average of (55.2±17.5) years old, 4 patients were typeⅠand 21 patients were typeⅡ according to Mayo classification. The operative time, intraoperative blood loss, times of Intraoperative fluoroscopy, fracture healing time and complications of 3 groups were compared. At the final follow-up, elbow function was assessed using the Mayo Elbow Function Scale.
RESULTS:
There were differences in operative time, intraoperative fluoroscopy times, postoperative VAS and soft tissue irritation among the three groups(P<0.05). The operative time, intraoperative fluoroscopy times in group A and C was better than that in group B. The postoperative VAS score, skin irritability in group C was better than that of group B. The difference was statistically significant on Mayo elbow function score at the final follow-up among three groups(P<0.05), the scores of group A and C were higher than that of group B.
CONCLUSION
Compared with transcortical K-wires screw fixation, both intramedullary K-wires screw fixation and perforated Kirschner wire fixation, which can significantly reduce the occurrence of soft tissue irritation, reduce surgical complications and shorten the operation time.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Young Adult
;
Bone Wires
;
Retrospective Studies
;
Fracture Fixation, Internal
;
Ulna Fractures/surgery*
;
Olecranon Process/surgery*
;
Inflammation
;
Treatment Outcome
8.Long-term results of olecranon fractures treated using the XS nail® system.
Leonard HÖCHTL-LEE ; Matthias SPALTEHOLZ ; Tim Friedrich RAVEN ; Arash MOGHADDAM ; Wilhelm FRIEDL
Chinese Journal of Traumatology 2022;25(6):336-344
PURPOSE:
Olecranon fractures are particularly vulnerable to distraction and subsequent fracture dislocation due to the high tensile forces. Surgical treatment aims at reducing the fracture and restoring the anatomical joint surface condition, as well as neutralizing the strain inhibiting fracture healing. The XS nail® (Intercus GmbH, Bad Blankenberg, Germany), an intramedullary implant exerting compression across the entire fracture surface, unlike plates, leaves a minimal extra-cortical profile, and can be secured with threaded locking wires, thereby retaining the anatomical reduction without displacement or steps within the articular surface, which was often found in tension band wiring. After encouraging initial results, the long-term outcome was assessed.
METHODS:
This retrospective study evaluated the long-term outcome of patients surgically treated at our trauma center between January 2002 and December 2005 using the XS nail®. Patients over the age of 18 years eligible for the study must have undergone surgery for isolated, recent (less than 14 days) traumatic olecranon fractures, without concomitant injuries to the ipsilateral elbow and forearm. Further exclusion criteria were pseudarthrosis, re-fractures and osteotomy for distal humerus surgery, as well as polytraumatized patients unable to aid in their own recovery. Data were retrospectively gathered by standardised questionnaire and patient records, as well as surgery and anesthesiology reports. Data analysis was performed using Microsoft Office Excel® 2016.
RESULTS:
There were 32 patients, 13 males (mean age 49.0 years) and 19 females (mean age 68.9 years) with 11 Schatzkers type D, 7 each type A and C, 5 type B and 2 type E at an average of 55.2 months, all showing complete consolidation. Of them, 6 patients had a loss of range of motion with more than 10° in the sagittal plane, and only 1 patient exceeded 10° reduction of supination. Twenty-five patients reported being pain-free under all circumstances, and all but 2 patients (93.75%) had returned to their previous activity level. The average disabilities of the arm, shoulder and hand score was 21.15 (range 0-88.3), and the overall Mayo elbow performance index was 91.87, without complications, such as wound infection, neurovascular impairment or premature hardware removal.
CONCLUSION
Using the XS nail® system, all fracture types can be successfully treated and the rate of complications was lower than that treated by standard methods published in current literature. An excellent functional outcome, high range of motion as well as good retention of reduction without soft tissue irritation makes this a very suitable implant for fractures subject to tension.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Olecranon Process/injuries*
;
Retrospective Studies
;
Ulna Fractures/surgery*
;
Bone Wires
;
Fracture Fixation, Internal/methods*
;
Fractures, Bone
;
Range of Motion, Articular
;
Treatment Outcome
;
Elbow Injuries
9.Clinical observation of different surgical methods for metaphyseal sequelae of ulna.
Bing-le LYU ; Ya-Min TIAN ; Li-Ye GE ; Jing-Hua XU ; Dong-Sheng LI ; Jun-Yan TENG
China Journal of Orthopaedics and Traumatology 2021;34(7):636-640
OBJECTIVE:
To investigate the effect and safety of ulnar osteochondroma resection, ulnar minimally invasive osteotomy, external fixation and ulnar lengthening in the treatment of forearm deformity of metaphyseal extension of ulna.
METHODS:
From August 2005 to December 2013, there were 20 cases of ulnar metaphyseal sequelae, including 15 males and 5 females, aged from 7 to 13(10.00±2.34) years, the course of disease ranged for 6 to 11(8.10±1.52) months. The clinical manifestations were shortening of the affected forearm and bending to the ulnar side. The postoperative evaluation included pain, activities of daily living, orthopedic effect and the range of motion of wrist, elbow and forearm. The radiological evaluation included ulnar length, radial joint inclination angle and wrist epiphysis growth.
RESULTS:
All patients healed without infection. The only operation related to complications was ulnar lengthening, including 1 case of nonunion, 2 cases of ulnar lengthening callus fracture and 1 case of temporary radial nerve palsy. All patients were followed up for 4 to 7.5 years, with an average of (6.03±1.33) years. There were statistically significant differences in changes of wrist radial deviation, ulnar deviation, forearm pronation and supination in all cases (
CONCLUSION
Ulnar lengthening is not beneficial to prevent the development of long-term deformity. Simple resection of osteochondroma of distal ulna is beneficial to prevent the development of deformity. Patients with limited rotation of wrist joint and forearm and strong demand for improvement of appearance can be actively treated.
Activities of Daily Living
;
Elbow Joint
;
Female
;
Humans
;
Male
;
Radius/surgery*
;
Range of Motion, Articular
;
Treatment Outcome
;
Ulna/surgery*
;
Wrist Joint/surgery*
10.Treatment of aseptic ulnar diaphyseal nonunion with locking compression plate and autogenous iliac bone graft.
Dong-Xu FENG ; Liang SUN ; Wei-Lou FENG ; Kun ZHANG ; Shu-Hao LI ; Wei HUANG ; Yang-Jun ZHU ; Zan-Dong ZHAO
China Journal of Orthopaedics and Traumatology 2019;32(12):1160-1164
OBJECTIVE:
To investigate the clinical results of locking compression plate combined with autologous iliac bone graft in the treatment of aseptic ulnar nonunion.
METHODS:
From March 2009 to July 2017, 22 patients with aseptic ulnar diaphyseal nonunion with complete follow-up data were treated with surgery, including 12 males and 10 females, aged from 16 to 58 (39.7±9.9) years old and ranging in course of disease from 10 to 192 (39.4±55.7) months. There were 15 atrophic nonunions, 5 hypertrophic nonunions and 2 synovial pseudo-articular nonunions. After debridement of the nonunion, locking compression plate was used to fix the nonunion and autogenous iliac bone graft was given. Bone healing rate, surgical complications and clinical results were evaluated.
RESULTS:
All the patients were followed up, and the duration ranged from 13 to 42 months, with a mean of (22.5±8.2) months, and 1 patient did not heal. Visual analogue pain scores ranged from 0 to 3 (0.9±0.9). Pronation of forearm was 47 to 86 (69.0±14.7) degrees, supination was 35 to 85 (63.0±9.4) degrees, wrist flexion was 20 to 80 (51.0±10.2) degrees, wrist flexion was 32 to 88 (71.0±11.7) degrees, elbow flexion contracture was 0 to 25 (9.0±5.6) degrees, further flexion was 105 to 150 (134.0±13.9) degrees, and grip strength was 87% on the opposite side. According to the Anderson scoring system, 8 cases were excellent, 11 were satisfied, 2 were not satisfied, and 1 was failed.
CONCLUSIONS
LCP combined with autologous iliac bone graft can effectively treat aseptic ulna diaphyseal nonunion.
Adolescent
;
Adult
;
Bone Plates
;
Bone Transplantation
;
Diaphyses
;
Female
;
Fracture Fixation, Internal
;
Fractures, Ununited
;
surgery
;
Humans
;
Ilium
;
Male
;
Middle Aged
;
Retrospective Studies
;
Treatment Outcome
;
Ulna
;
Young Adult

Result Analysis
Print
Save
E-mail