1.A Narrative Review on the Double Pulley-Triple Row Technique for Large to Massive Rotator Cuff Repair
Vivek Kumar MORYA ; Jun LANG ; Yong-beom LEE ; Jung Woo KIM ; Kang Uk LEE ; Kyu-Cheol NOH
Clinics in Orthopedic Surgery 2025;17(3):359-371
Rotator cuff tears are common shoulder injuries that often necessitate surgical intervention, particularly when nonoperative treatments fail. Arthroscopic rotator cuff repair is the current gold standard; however, challenges, such as high retear rates, especially in large tears, persist. Traditional techniques, such as single-row and double-row repairs, have limitations in fully restoring the anatomical footprint and ensuring optimal healing. This review examines the novel double pulley-triple row technique, which aims to overcome these limitations by enhancing the footprint contact area, load distribution, and tendon healing. By evaluating the double pulley-triple row method in comparison to established techniques, this study explores the potential advantages, limitations, and future directions of rotator cuff repair.
2.Re-do laparoscopic common bile duct exploration for recurrent common bile duct stones: a single-center retrospective cohort study
In Ho LEE ; Seung Jae LEE ; Ju Ik MOON ; Sang Eok LEE ; Nak Song SUNG ; Seong Uk KWON ; In Eui BAE ; Seung Jae RHO ; Sung Gon KIM ; Min Kyu KIM ; Dae Sung YOON ; Won Jun CHOI ; In Seok CHOI
Annals of Surgical Treatment and Research 2025;108(5):310-316
Purpose:
Common bile duct (CBD) stone recurrence after laparoscopic CBD exploration (LCBDE) is relatively common. No studies have been conducted evaluating the safety and feasibility of re-do LCBDE in the treatment of recurrent CBD stones.
Methods:
This single-center retrospective study reviewed 340 consecutive patients who underwent LCBDE for CBD stones between January 2004 and December 2020. Patients with pancreatobiliary malignancies and those who underwent other surgical procedures were excluded.
Results:
Of the 340 included patients, 45 experienced a recurrence after a mean follow-up period of 24.2 months. Of them, 18 underwent re-do LCBDE, 20 underwent endoscopic intervention, 2 underwent radiologic intervention, and 5 underwent observation. Re-do LCBDE and initial LCBDE showed similar surgical outcomes in terms of operative time (113.1 minutes vs. 107.5 minutes, P = 0.515), estimated blood loss (42.5 mL vs. 49.1 mL, P = 0.661), open conversion rate (2.9% vs. 0%, P = 0.461), postoperative complication (15.3% vs. 22.2%, P = 0.430), and postoperative hospital stay (6.5 days vs. 6.4 days, P = 0.921). Comparing re-do LCBDE and nonsurgical treatment (endoscopic or radiologic), no statistically significant differences were noted in posttreatment complication (22.2% vs. 13.6%, P = 0.477), hospital stay (6.4 days vs.7.3 days, P = 0.607), and recurrence (50.0% vs. 36.4%, P = 0.385). The clearance rate was higher in the re-do LCBDE group than in the nonsurgical group (100% vs. 81.8%, P = 0.057).
Conclusion
Compared to initial LCBDE and endoscopic or radiological treatments, re-do LCBDE for recurrent CBD stones is a treatment option worth considering in selected patients.
3.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
4.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
5.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
6.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
7.Predisposing Risk Factors Affecting Reversibility of Left Ventricular Diastolic Filling Pattern in Patients with Preserved Ejection Fraction
Dong-Gil KIM ; Sungsoo CHO ; Seongjin PARK ; Gi Rim KIM ; Kyu-Yong KO ; Sung Eun KIM ; Ji-won HWANG ; Joon-Hyung DOH ; Sung Uk KWON ; Jae-Jin KWAK ; June NAMGUNG ; Sung Woo CHO
Yonsei Medical Journal 2025;66(1):1-8
Purpose:
Improvement of left ventricular (LV) diastolic dysfunction (DD) is known to be a good prognostic factor in patients with heart failure with reduced ejection fraction (EF). In the present study, we investigated the predisposing risk factors affecting the reversibility of LV diastolic filling pattern (DFP) in patients with preserved EF.
Materials and Methods:
A total of 600 patients with pseudonormal LVDFP and preserved EF who underwent follow-up echocardiography were enrolled between 2011 and 2020. We compared their index and follow-up echocardiography findings and determined the predisposing risk factor affecting the reversibility of LVDFP.
Results:
Comparing the index and follow-up echocardiography findings showed that 379 (63%) patients had improved to normal or impaired relaxation LVDFP (improved group) and 221 (37%) patients had maintained or worsened LVDFP (unimproved group).The incidence of paroxysmal atrial fibrillation (PAF) was significantly higher in the unimproved group than in the improved group (4.7% vs. 9.5%, p=0.026). After adjustment for relevant clinical risk factors of diastolic dysfunction, PAF was determined to be an independent predisposing risk factor for the unimproved LVDFP (odds ratio: 2.10, 95% confidence interval: 1.06–4.15, p=0.033).Among the parameters of diastolic dysfunction in follow-up echocardiography, the left atrial volume index, mean E/A ratio, and E/e' were significantly improved in patients without PAF but remained in patients with PAF.
Conclusion
We identified that PAF was an independent predisposing risk factor of the unimproved LVDFP in patients with pseudonormal LVDFP and preserved EF. Therefore, early detection and management of PAF might be required in patients with LVDD and preserved EF to prevent adverse cardiovascular events.
8.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
9.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
10.Predisposing Risk Factors Affecting Reversibility of Left Ventricular Diastolic Filling Pattern in Patients with Preserved Ejection Fraction
Dong-Gil KIM ; Sungsoo CHO ; Seongjin PARK ; Gi Rim KIM ; Kyu-Yong KO ; Sung Eun KIM ; Ji-won HWANG ; Joon-Hyung DOH ; Sung Uk KWON ; Jae-Jin KWAK ; June NAMGUNG ; Sung Woo CHO
Yonsei Medical Journal 2025;66(1):1-8
Purpose:
Improvement of left ventricular (LV) diastolic dysfunction (DD) is known to be a good prognostic factor in patients with heart failure with reduced ejection fraction (EF). In the present study, we investigated the predisposing risk factors affecting the reversibility of LV diastolic filling pattern (DFP) in patients with preserved EF.
Materials and Methods:
A total of 600 patients with pseudonormal LVDFP and preserved EF who underwent follow-up echocardiography were enrolled between 2011 and 2020. We compared their index and follow-up echocardiography findings and determined the predisposing risk factor affecting the reversibility of LVDFP.
Results:
Comparing the index and follow-up echocardiography findings showed that 379 (63%) patients had improved to normal or impaired relaxation LVDFP (improved group) and 221 (37%) patients had maintained or worsened LVDFP (unimproved group).The incidence of paroxysmal atrial fibrillation (PAF) was significantly higher in the unimproved group than in the improved group (4.7% vs. 9.5%, p=0.026). After adjustment for relevant clinical risk factors of diastolic dysfunction, PAF was determined to be an independent predisposing risk factor for the unimproved LVDFP (odds ratio: 2.10, 95% confidence interval: 1.06–4.15, p=0.033).Among the parameters of diastolic dysfunction in follow-up echocardiography, the left atrial volume index, mean E/A ratio, and E/e' were significantly improved in patients without PAF but remained in patients with PAF.
Conclusion
We identified that PAF was an independent predisposing risk factor of the unimproved LVDFP in patients with pseudonormal LVDFP and preserved EF. Therefore, early detection and management of PAF might be required in patients with LVDD and preserved EF to prevent adverse cardiovascular events.

Result Analysis
Print
Save
E-mail