1.Second chance in fertility: a comprehensive narrative review of redo micro-TESE outcomes after initial failure.
Haitham ELBARDISI ; Emre BAKIRCIOGLU ; Wen LIU ; Darren KATZ
Asian Journal of Andrology 2025;27(3):409-415
When microdissection testicular sperm extraction (micro-TESE) fails, a redo procedure may be the only option for patients who want a biological child. However, there are many gaps of knowledge surrounding the procedure, which need to be addressed to help clinicians and patients make informed decisions. This review explores redo micro-TESE in the context of nonobstructive azoospermia (NOA). Literature was searched using Google Scholar, Medline, and PubMed. Search terms were "NOA" AND "second microdissection testicular sperm extractions" AND "redo microdissection testicles sperm extraction" AND "repeat microdissection testicular sperm extractions" AND "failed microdissection testicular sperm extractions" AND "salvage microdissection testicular sperm extractions". Only original articles in English were included. A total of nine articles were included, consisting of four retrospective and five prospective studies. The time gap between the first and second micro-TESE varied from 6 months to 24 months. Most of the included studies reported successful surgical sperm retrieval (SSR) in the second micro-TESE in the range of 10%-21%, except in one study where it reached 42%. It has not been presented any definitive information about the use of hormonal treatment or the benefit of varicocelectomy prior to the second micro-TESE. Patients with hypospermatogenesis and Klinefelter syndrome (KS) had the highest chance of success in redo surgery. In conclusion, redo micro-TESE following a negative procedure can lead to sperm recovery in 10%-21%. Patients with hypospermatogenesis and KS have a higher chance of success. There is no enough evidence to conclude which is the best hormonal stimulation if any before a redo surgery.
Humans
;
Male
;
Azoospermia/surgery*
;
Sperm Retrieval
;
Microdissection
;
Reoperation
;
Treatment Failure
;
Testis/surgery*
;
Treatment Outcome
2.Factors associated with prognosis and treatment failure in children with acute lymphoblastic leukemia.
Meng-Meng YIN ; Qun HU ; Ai-Guo LIU ; Ya-Qin WANG ; Ai ZHANG
Chinese Journal of Contemporary Pediatrics 2025;27(3):308-314
OBJECTIVES:
To explore the factors related to prognosis and treatment failure in children with acute lymphoblastic leukemia (ALL).
METHODS:
A retrospective study was conducted to collect and analyze clinical data of ALL children admitted to the Department of Pediatric Hematology at Tongji Hospital, Huazhong University of Science and Technology, from January 2012 to December 2019, with follow-up until June 2024.
RESULTS:
A total of 341 children with ALL were included. Among the 69 children with treatment failure, 55 (80%) experienced relapse, while 14 (20%) had non-relapse-related deaths, and no secondary tumors were observed. Initial WBC count ≥50×109/L, positive minimal residual disease, and severe adverse events were identified as independent risk factors for treatment failure (P<0.05). Among the 55 relapsed patients, early relapses were predominant (36%), and the primary site of relapse was the bone marrow (56%). Immunophenotyping (P=0.009), initial WBC count (P=0.011), and fusion genes (P=0.040) were associated with the timing of relapse. High-risk status, T-cell ALL, relapse, and severe adverse events were independent risk factors affecting long-term survival (P<0.05).
CONCLUSIONS
The prognosis of children with ALL is related to risk stratification, immunophenotyping, relapse status, and occurrence of severe adverse events. Among these factors, relapse is the primary cause of treatment failure. Actively preventing relapse may reduce the treatment failure rate and improve long-term survival.
Humans
;
Precursor Cell Lymphoblastic Leukemia-Lymphoma/therapy*
;
Male
;
Female
;
Child
;
Child, Preschool
;
Retrospective Studies
;
Prognosis
;
Treatment Failure
;
Adolescent
;
Infant
;
Risk Factors
3.Valve-in-valve transcatheter mitral valve replacement with SAPIEN 3 valve for bioprosthetic mitral valve failure: one-year outcomes in 26 patients.
Zechao RAN ; Lulu LIU ; Jun SHI ; Yuqiang WANG ; Tingqian CAO ; Siyu HE ; Xiaoting LI ; Yingqiang GUO
Journal of Zhejiang University. Medical sciences 2025;54(5):668-675
OBJECTIVES:
To evaluate the one-year outcomes of valve-in-valve transcatheter mitral valve replacement (ViV-TMVR) using SAPIEN 3 valve for treating mitral bioprosthetic valve failure.
METHODS:
A retrospective analysis was conducted on 26 patients with mitral bioprosthetic valve failure who underwent ViV-TMVR at West China Hospital, Sichuan University, between November 2022 and July 2024. The age of patients was 71.5 (64.5, 74.5) years, and 69.2% were female. Bioprosthetic valve failure occurred at (9.7±3.7) years after initial surgical implantation, with the most common failure mode being mixed stenosis and regurgitation (53.8%). The SAPIEN 3 valve was implanted via either a transseptal or transapical approach. Echocardiography was performed preoperatively, immediately post-procedure, and at 1 month, 6 months, and 1 year post-procedure. Outcomes included all-cause mortality, New York Heart Association (NYHA) functional class, Kansas City Cardiomyopathy Questionnaire (KCCQ)-12 score, and postoperative complications.
RESULTS:
The procedure was performed via the transseptal approach in 21 patients (80.8%) and the transapical approach in 5 patients (19.2%). All procedures were technically successful. No paravalvular leakage was observed immediately post-procedure, and mitral valve hemodynamics improved significantly. At the 1-year follow-up, 2 patients had died. Two patients (8.3% of survivors) were of NYHA functional class Ⅲ, and KCCQ-12 score improved to (88.4±14.6) points (both P<0.01). Echocardio-graphy at 1 year postoperatively showed significant reductions in peak mitral valve velocity [to (2.29±0.32) m/s] and mean transvalvular pressure gradient [to (9.5±3.5) mmHg, 1 mmHg=0.133 kPa] compared to baseline (both P<0.05). No moderate or severe mitral regurgitation or paravalvular leakage was observed. The proportion of patients with moderate-to-severe pulmonary hypertension decreased from 65.4% preoperatively to 13.0% at 1 year (P<0.05).
CONCLUSIONS
ViV-TMVR with the SAPIEN 3 valve for mitral biopro-sthetic valve failure is associated with high procedural success, significantly improved valve hemodynamics of the mitral value, alleviation of pulmonary hypertension, enhanced quality of life, and a low rate of complications at 1 year after the operation.
Humans
;
Female
;
Male
;
Retrospective Studies
;
Aged
;
Bioprosthesis
;
Heart Valve Prosthesis
;
Mitral Valve/surgery*
;
Heart Valve Prosthesis Implantation/methods*
;
Middle Aged
;
Prosthesis Failure
;
Treatment Outcome
;
Mitral Valve Insufficiency/surgery*
4.A Case of Endometrial Metastasis in Lung Adenocarcinoma after EGFR-TKIs Treatment Failure and Literature Review.
Fangqian SHEN ; Zuling HU ; Hua YANG ; Puyu LIU ; Yuju BAI ; Jianguo ZHOU ; Hu MA
Chinese Journal of Lung Cancer 2025;28(7):551-557
The incidence and mortality rates of lung cancer remain high, making it the leading cause of cancer-related deaths. In women, the predominant histological subtype is lung adenocarcinoma, commonly associated with epidermal growth factor receptor (EGFR) mutations, and EGFR-tyrosine kinase inhibitors (EGFR-TKIs) can significantly improve patient prognosis. Metastasis of primary lung cancer to the endometrium is extremely rare and is often misdiagnosed as a primary reproductive system tumor, and its occurrence indicates poor prognosis. This article reports a case of an advanced lung adenocarcinoma patient with EGFR mutation, who developed abnormal vaginal bleeding after EGFR-TKIs treatment failure, and biopsy confirmed endometrial metastasis. A review of similar cases is also presented.
.
Humans
;
Female
;
ErbB Receptors/metabolism*
;
Endometrial Neoplasms/genetics*
;
Lung Neoplasms/genetics*
;
Protein Kinase Inhibitors/therapeutic use*
;
Adenocarcinoma of Lung/drug therapy*
;
Treatment Failure
;
Middle Aged
;
Adenocarcinoma/genetics*
5.Risk factors and prognosis of first extubation failure in neonates undergoing invasive mechanical ventilation.
Mengyao WU ; Hui RONG ; Rui CHENG ; Yang YANG ; Keyu LU ; Fei SHEN
Journal of Central South University(Medical Sciences) 2025;50(8):1398-1407
OBJECTIVES:
Prolonged invasive mechanical ventilation is associated with increased risks of severe complications such as retinopathy of prematurity and bronchopulmonary dysplasia. Although neonatal intensive care unit (NICU) follow the principle of early extubation, extubation failure rates remain high, and reintubation may further increase the risk of adverse outcomes. This study aims to identify risk factors and short-term prognosis associated with first extubation failure in neonates, to provide evidence for effective clinical intervention strategies.
METHODS:
Clinical data of neonates who received invasive ventilation in the NICU of Children's Hospital of Nanjing Medical University from January 1, 2019, to December 31, 2021, were retrospectively collected. Neonates were divided into a successful extubation group and a failed extubation group based on whether reintubation occurred within 72 hours after the first extubation. Risk factors and short-term outcomes related to extubation failure were analyzed.
RESULTS:
A total of 337 infants were included, with 218 males (64.69%). Initial extubation failed in 34 (10.09%) infants. Compared with the successful extubation group, the failed extubation group had significantly lower gestational age [(31.37±5.14) weeks vs (34.44±4.07) weeks], age [2.5 (1.00, 8.25) h vs 5 (1.00, 22.00) h], birth weight [(1 818.97±1128.80) g vs (2 432.18±928.94) g], 1-minute Apgar score (6.91±1.90 vs 7.68±2.03), and the proportion of using mask oxygenation after extubation (21% vs 46%) (all P<0.05). Conversely, compared with the successful extubation group, the failed extubation group had significantly higher rates of vaginal delivery (59% vs 32%), caffeine use during mechanical ventilation (71% vs 38%), dexamethasone use at extubation (44% vs 17%), the highest positive end-expiratory pressure level within 72 hours post-extubation [6(5.00, 6.00) cmH2O vs 5 (0.00, 6.00) cmH2O] (1 cmH2O=0.098 kPa), the highest FiO2 within 72 hours post-extubation [(34.35±5.95)% vs (30.22±3.58)%], and duration of noninvasive intermittent positive pressure ventilation after extubation [0.5 (0.00, 42.00) hours vs 0 (0, 0) hours] (all P<0.05). Multivariate analysis identified gestational age <28 weeks (OR=5.570, 95% CI 1.866 to 16.430), age at NICU admission (OR=0.959, 95% CI 0.918 to 0.989), and a maximum FiO2≥35% within 72 hours post-extubation (OR=4.541, 95% CI 1.849 to 10.980) as independent risk factors for extubation failure (all P<0.05). Additionally, the failed extubation group exhibited significantly higher incidences of necrotizing enterocolitis grade II or above, moderate-to-severe bronchopulmonary dysplasia, severe bronchopulmonary dysplasia, retinopathy of prematurity, treatment abandonment due to poor prognosis, and discharge on home oxygen therapy (all P<0.05). Total hospital length of stay and total hospitalization costs were also significantly increased in the failed extubation group (all P<0.05).
CONCLUSIONS
Gestational age <28 weeks, younger age at NICU admission, and FiO2≥35% after extubation are high-risk factors for first extubation failure in neonates. Extubation failure markedly increases the risk of adverse clinical outcomes.
Humans
;
Infant, Newborn
;
Male
;
Female
;
Airway Extubation/adverse effects*
;
Risk Factors
;
Retrospective Studies
;
Respiration, Artificial/methods*
;
Intensive Care Units, Neonatal
;
Prognosis
;
Gestational Age
;
Bronchopulmonary Dysplasia
;
Infant, Premature
;
Treatment Failure
;
Intubation, Intratracheal
6.Meta-analysis of different joint interfaces in total hip arthroplasty under long-term follow-up.
Gai-Ge WU ; Ling-An HUANG ; Li GUO ; Peng-Cui LI ; Xiao-Chun WEI
China Journal of Orthopaedics and Traumatology 2023;36(2):165-171
OBJECTIVE:
To compare the long-term follow-up effect and complications of ceramic on ceramic (CoC) interface and ceramic on polyethyleneon ceramic (CoP) interface in primary total hip arthroplasty, and provide clinical evidence.
METHODS:
Search PubMed, EMBase, the CoChrane Library databases, Web of science, Wanfang database, and CNKI from January 2000 to September 2021, screening and inclusion of randomized controlled trials (RCTs) comparing the long-term efficacy and complications of CoC interface and CoP interface in total hip arthroplasty. Literature screening, quality evaluation and data extraction were carried out according to the inclusion and exclusion criteria, using Review Manager 5.3 statistical software. The software was used to perform statistical analysis on joint function, revision, prosthesis fracture, abnormal joint noise, and prosthesis wear rate after CoC or CoP.
RESULTS:
Seven RCTs studies were included, including 390 cases of hips with CoC artificial joints and 384 cases of hips with CoP artificial joints. The long-term joint function improvement of CoC and CoP artificial joints was similar and there was no significant differences, with an average difference was MD=0.63, 95%CI=(-1.81, 3.07), P=0.61. About the postoperative complications, CoC artificial joints have higher incidence rate of abnormal joint noise, with odds ratio (OR)=11.05, 95%CI=(2.04, 59.84), P=0.005. CoP artificial joints wear faster, with an average MD=-87.11, 95%CI=(-114.40, -59.82), P<0.000 1. There was no significant difference between the two groups in the replacement-related complications such as joint dislocation, prosthesis loosening, osteolysis, and the rate of prosthesis revision caused by various reasons.
CONCLUSION
The clinical function results and complications of CoC artificial joints are comparable to those of CoP artificial joints. Although CoP artificial joint prosthesis has a faster wear rate, it does not affect joint function and increase complications, and there is no abnormal joint noise. CoC is expensive and the long-term efficacy is equivalent to CoP. Clinicians should consider cost performance when choosing CoC.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Prosthesis
;
Follow-Up Studies
;
Prosthesis Design
;
Polyethylene
;
Prosthesis Failure
;
Reoperation
;
Ceramics
;
Treatment Outcome
7.Total hip arthroplasty for post-firearm hip arthritis complicated by coloarticular fistula: A case report.
Ahmed M ABDELAAL ; Mohammad Kamal ABDELNASSER ; Mohamed Ma MOUSTAFA ; Ahmed Mohamed ALI ; Haisam ATTA ; Ahmed A KHALIFA
Chinese Journal of Traumatology 2023;26(6):369-374
Hip firearm injuries are rare injuries that could lead to serious complications, such as posttraumatic hip arthritis and coloarticular fistula. We report a case of a 25-year-old male who sustained a pelvic injury caused by a single bullet which led to a bilateral acetabular fracture, concomitant with a colon injury treated on an emergency basis by a diverting colostomy; acetabular fractures were treated conservatively by traction. After the patient recovered from the abdominal injury, he was presented with bilateral hip pain and limited motion; plain radiographs showed bilateral hip arthritis with proximal migration of the femoral head and bilateral acetabular defect classified as Paprosky type ⅢA. Reconstruction of the hips was performed using the same technique: impaction bone grafting for acetabular defect reconstruction and a reversed hybrid total hip arthroplasty (THA) 6 months apart. The patient presented with loosening of the left THA acetabular cup 3 years later, which was revised; then he presented with a discharging sinus from the left THA with suspicion of coloarticular fistula, which was confirmed using CT with contrast material. A temporary colostomy and fistula excision were performed, and a cement spacer was applied to the hip. After clearing the infection, a final revision THA for the left hip was performed. Treating post-firearm hip arthritis by THA is challenging, especially in the situation of neglected cases with the presence of an acetabular defect. Concomitant intestinal injury increases the risk of infection with the possibility of coloarticular fistula formation, which could present later. Working with a multidisciplinary team is paramount.
Male
;
Humans
;
Adult
;
Arthroplasty, Replacement, Hip
;
Firearms
;
Wounds, Gunshot/surgery*
;
Acetabulum/injuries*
;
Hip Fractures/surgery*
;
Arthritis/surgery*
;
Spinal Fractures/surgery*
;
Reoperation
;
Fistula/surgery*
;
Treatment Outcome
;
Follow-Up Studies
;
Prosthesis Failure
;
Retrospective Studies
8.Comparison of immediate changes of repolarization parameters after left bundle branch area pacing and traditional biventricular pacing in heart failure patients.
Yao LI ; Wenzhao LU ; Qingyun HU ; Chendi CHENG ; Jinxuan LIN ; Yu'an ZHOU ; Ruohan CHEN ; Yan DAI ; Keping CHEN ; Shu ZHANG
Chinese Medical Journal 2023;136(7):868-870
9.Clinical efficacy of simple taper retentive implants in immediate posterior dental implantation for 5-7 years.
Bihui REN ; Shuigen GUO ; Yehao XU ; Jieting DAI ; Hongwu WEI
West China Journal of Stomatology 2023;41(3):341-349
OBJECTIVES:
This study aimed to evaluate the long-term clinical efficacy of simple taper retentive implants in the posterior dental area after immediate implantation for 5-7 years.
METHODS:
Selected from January 2015 to December 2017 in the Fourth Affiliated Hospital of Nanchang University dental clinic line tooth area immediately after the implant prosthesis, a total of 38 patients, 53 implants, were deep into (bone under 2 mm or higher) and the upper structure was repaired. In addition, after the completion of tracking observation of 60-90 months, the implant surrounding bone health was recorded and analyzed.
RESULTS:
After 5-7 years of follow-up, 1 of the 53 implants failed to fall out, and the implant retention rate was 98.1%. The amount of bone resorption in the proximal and distal margins 5-7 years after implant restoration was (0.16±0.94) mm and (-0.01±1.29) mm, respectively, and the difference in bone height between the proximal and distal margins of the implant and the immediate post-restoration period was not statistically significant (P>0.05). No statistically significant differences were found in the effects of periodontitis, implant site inflammation, and smoking on peri-implant marginal bone resorption (P>0.05).
CONCLUSIONS
The single taper-retained implant broadens the indications for immediate implant placement in the posterior region, and its deep sub-osseous placement (≥2 mm below the bone) avoids to a certain extent the disturbance of the implant by external stimuli and the exposure of the cervical abutment of the implant, with the good long-term stability of the marginal bone around the implant.
Humans
;
Dental Implantation, Endosseous
;
Dental Implants
;
Immediate Dental Implant Loading
;
Follow-Up Studies
;
Dental Implants, Single-Tooth
;
Alveolar Bone Loss/surgery*
;
Treatment Outcome
;
Dental Prosthesis, Implant-Supported
;
Dental Restoration Failure
10.Effects of Compound Danshen Dripping Pills on Ventricular Remodeling and Cardiac Function after Acute Anterior Wall ST-Segment Elevation Myocardial Infarction (CODE-AAMI): Protocol for a Randomized Placebo-Controlled Trial.
Yu-Jie WU ; Bo DENG ; Si-Bo WANG ; Rui QIAO ; Xi-Wen ZHANG ; Yuan LU ; Li WANG ; Shun-Zhong GU ; Yu-Qing ZHANG ; Kai-Qiao LI ; Zong-Liang YU ; Li-Xing WU ; Sheng-Biao ZHAO ; Shuang-Lin ZHOU ; Yang YANG ; Lian-Sheng WANG
Chinese journal of integrative medicine 2023;29(12):1059-1065
BACKGROUND:
Ventricular remodeling after acute anterior wall ST-segment elevation myocardial infarction (AAMI) is an important factor in occurrence of heart failure which additionally results in poor prognosis. Therefore, the treatment of ventricular remodeling needs to be further optimized. Compound Danshen Dripping Pills (CDDP), a traditional Chinese medicine, exerts a protective effect on microcirculatory disturbance caused by ischemia-reperfusion injury and attenuates ventricular remodeling after myocardial infarction.
OBJECTIVE:
This study is designed to evaluate the efficacy and safety of CDDP in improving ventricular remodeling and cardiac function after AAMI on a larger scale.
METHODS:
This study is a multi-center, randomized, double-blind, placebo-controlled, parallel-group clinical trial. The total of 268 patients with AAMI after primary percutaneous coronary intervention (pPCI) will be randomly assigned 1:1 to the CDDP group (n=134) and control group (n=134) with a follow-up of 48 weeks. Both groups will be treated with standard therapy of ST-segment elevation myocardial infarction (STEMI), with the CDDP group administrating 20 tablets of CDDP before pPCI and 10 tablets 3 times daily after pPCI, and the control group treated with a placebo simultaneously. The primary endpoint is 48-week echocardiographic outcomes including left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume index (LVEDVI), and left ventricular end-systolic volume index (LVESVI). The secondary endpoint includes the change in N terminal pro-B-type natriuretic peptide (NT-proBNP) level, arrhythmias, and cardiovascular events (death, cardiac arrest, or cardiopulmonary resuscitation, rehospitalization due to heart failure or angina pectoris, deterioration of cardiac function, and stroke). Investigators and patients are both blinded to the allocated treatment.
DISCUSSION
This prospective study will investigate the efficacy and safety of CDDP in improving ventricular remodeling and cardiac function in patients undergoing pPCI for a first AAMI. Patients in the CDDP group will be compared with those in the control group. If certified to be effective, CDDP treatment in AAMI will probably be advised on a larger scale. (Trial registration No. NCT05000411).
Humans
;
ST Elevation Myocardial Infarction/therapy*
;
Stroke Volume
;
Ventricular Remodeling
;
Prospective Studies
;
Microcirculation
;
Ventricular Function, Left
;
Myocardial Infarction/etiology*
;
Treatment Outcome
;
Percutaneous Coronary Intervention/adverse effects*
;
Heart Failure/drug therapy*
;
Drugs, Chinese Herbal/therapeutic use*
;
Randomized Controlled Trials as Topic
;
Multicenter Studies as Topic

Result Analysis
Print
Save
E-mail