1.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
2.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
3.Cuproptosis: A novel therapeutic target for non-small cell lung cancer
Dong DONG ; Yajie ZHANG ; Hecheng LI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(05):826-832
Cuproptosis, recently defined as a unique form of cell death distinct from programmed cell death, is triggered by copper overload within mitochondria. Genes associated with cuproptosis have been found to correlate with tumorigenesis and tumor progression, making the targeting of cuproptosis pathways a promising direction for anti-tumor therapies. Copper ion carriers can transport copper ions into cells, inducing cuproptosis and laying the foundation for its application in cancer treatment. This article elaborates on the homeostasis of copper and the mechanisms related to cuproptosis, further clarifying the relationship between cuproptosis and lung cancer treatment targets. This review aims to summarize current progress in research related to cuproptosis and lung cancer, providing new theories and bases for the clinical treatment of lung cancer.
4.Expert consensus on precise intervention with repetitive transcranial magnetic stimulation for sleep disorders in the elderly
Yuan SHAO ; Jian WANG ; Wei LIANG ; Yingli ZHANG ; Gangqiang HOU ; Xia LI ; Yi XING ; Lu WANG ; Shi TANG ; Yongjun WANG
Sichuan Mental Health 2026;39(2):97-105
In recent years, repetitive transcranial magnetic stimulation (rTMS) has garnered significant attention as a therapeutic approach for sleep disorders in the elderly. However, the prevailing rTMS protocols are predominantly developed based on normative neurophysiological data derived from young adults and fail to incorporate individualized parameters tailored to the brain characteristics of the elderly. To address this gap, the consensus development group synthesized the latest evidence from 2010 to 2025 and established a standardized rTMS protocol specifically for elderly patients with sleep disorders. Adhering to the Appraisal of Guidelines for Research and Evaluation II (AGREE II) framework, systematically screened randomized controlled trials (RCTs) and systematic reviews regarding rTMS in the treatment of sleep disorders across various conditions. Meanwhile, the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was employed to rigorously grade the quality of evidence and the strength of recommendations. This consensus guideline delineates precise rTMS protocols for the management of sleep disorders in the elderly, highlights the adjustment of stimulation intensity according to scalp-cortex distance recommends either MRI‑guided neuronavigation or the Beam F3/F4 heuristic approach for accurate target localization, thereby providing precise rTMS intervention protocol for sleep disorders in the elderly, aiming to enhance clinical efficacy while ensuring treatment safety. [Funded by National Key Research and Development Program (number, 2023YFC3603200); General Program of Shenzhen Science and Technology Innovation Commission (number, JCYJ20240813112859008, JCYJ20240813112900002); Youth Program of Shenzhen Kangning Hospital (number, KN2023A004); www.guidelines-registry.cn number, PREPARE-2026CN530]
5.Health risk assessment of employees in an enterprise involving lead, arsenic and cadmium
Yanru WANG ; Zhaohui ZHANG ; Yuqi TONG ; Yaqi LI
Journal of Public Health and Preventive Medicine 2026;37(3):66-70
Objective To investigate occupational exposure levels of lead, arsenic and cadmium in the lead smelting plant of Hunan Shui Kou Shan Nonferrous Metals Group Co. Ltd., analyze their effects on health of employees, and compare the applicability of different occupational health risk assessment methods, and to provide a basis for prevention and control of occupational exposure risks in enterprises. Methods According to systematic sampling method, 380 employees with lead, arsenic and cadmium exposure (exposure group) and 100 non-exposure employees (non-exposure group) were selected from 2022 to 2024 for on-site investigation of occupational health [concentration time-weighted average (CTWA)] and physical examination. The risk was evaluated by qualitative assessment method, the U.S. Environmental Protection Agency (EPA) inhalation risk assessment method, and the Singapore Ministry of Manpower (MOM) semi-quantitative method. The consistency was analyzed by the Kappa test. Results CTWA values of lead, arsenic, and cadmium in all positions were lower than the occupational exposure limit (OEL). The levels of blood lead, urine arsenic, and urine cadmium, as well as the prevalence of multiple systems in the exposure group were significantly higher than those in the non-exposure group (P<0.05). The proportions of chronic lead, arsenic, and cadmium poisoning were increasing year by year in the exposure group (P<0.05). The qualitative assessment method mainly indicated low and medium risk, while the EPA and MOM methods mainly indicated medium and high risk, with good agreement between the two methods (Kappa=0.676, P<0.05). Conclusion Although the enterprise meets the CTWA standards, there are still occupational health risks of lead, arsenic, and cadmium. The EPA inhalation risk assessment method is more applicable.
6.Influencing Factors of Depression in Patients with Postoperative Ovarian Cancer
Jialiang YAO ; Long ZHANG ; Jianhui TIAN ; Ze LIU ; Yun YANG ; Yiyang ZHOU ; Minghua LI ; Wang YAO ; Wenfei SHI ; Xinyi LU ; Pan YU ; Enchao CONG
Cancer Research on Prevention and Treatment 2026;53(5):349-359
Objective To explore the prevalence of depressive symptoms in postoperative patients with ovarian cancer and to analyze its influencing factors from multiple dimensions, including clinical characteristics, psychological factors, and laboratory indicators. Methods A cross-sectional study was conducted, which enrolled 235 postoperative patients with ovarian cancer. Depressive status was assessed using the patient health questionnaire, and the demographic, pathological, and medical record data of the patients were collected using the generalized anxiety disorder scale, Pittsburgh sleep quality index, European organization for research and treatment of cancer quality of life questionnaire core 30, and ECOG performance status score. Peripheral blood tumor marker (CA125), routine blood test, lymphocyte subsets, and serum cytokine levels were measured. Univariate and multivariate binary logistic regression analysis were used for statistical analysis. Results The prevalence of depression in postoperative patients with ovarian cancer was 39.15% (92/235). Univariate analysis showed that ECOG score ≥ 2 points, pain, anxiety, poor sleep quality, low quality of life, low life satisfaction, tumor recurrence, six or more cycles of chemotherapy, as well as higher levels of CA125, NLR, and NAR, and lower hemoglobin levels were significantly associated with depression (all P<0.05). Multivariate binary Logistic regression analysis showed that anxiety (OR=1.975, 95%CI: 1.231-3.170), sleep efficiency (OR=4.181, 95%CI: 1.211-14.43), sleep latency (OR=34.806, 95%CI: 4.258-284.542), ECOG performance status score, cognitive function (OR=0.918, 95%CI: 0.868-0.97), and life satisfaction were independent risk factors for depression (all P<0.05). Laboratory indicators were not independent influencing factors in the multivariate Logistic regression model. Conclusion Depression in postoperative patients with ovarian cancer is influenced by physiological, psychological, and social factors. Clinical management should focus on patients with anxiety, sleep disorders, poor physical condition, and low life satisfaction, and a comprehensive prevention and treatment strategy centered on psychological intervention and taking into account symptom management and social support should be implemented.
7.Clinical and epidemiological characteristics of human bocavirus in hospitalized children with acute lower respiratory tract infection at a hospital in Shanghai from 2021 to 2023
Shan ZHANG ; Yujuan HUANG ; Lei SHEN ; Li LIU ; Jie WANG ; Huilin ZHOU ; Leijun MENG ; Tingting CHEN
Shanghai Journal of Preventive Medicine 2026;38(3):193-198
ObjectiveTo investigate the epidemiological and clinical characteristics of human bocavirus (HBoV) in hospitalized children with acute lower respiratory tract infection (ALRTI) at a single-center children’s hospital in Shanghai, thereby providing evidence for the diagnosis, treatment, and prevention of HBoV infection. MethodsA retrospective study was conducted on 19 537 hospitalized children with ALRTI at Shanghai Children’s Hospital from January 2021 to December 2023. Multiplex polymerase chain reaction (PCR) combined with capillary electrophoresis was used to detect HBoV and 12 other common respiratory viruses /atypical pathogens. The positive detection rate, demographic characteristics (sex, age), temporal distribution (year, season) of HBoV, as well as the clinical characteristics of severe and non-severe pneumonia were analyzed. ResultsThe overall HBoV-positive rate was 2.57% (503/19 537), with 59.44% (299/503) being single infections and 40.56% (204/503) being co-infections. The positive detection rate was significantly higher in boys than that in girls (2.78% vs 2.33%, χ²=3.88, P=0.049). The highest infection rate was observed in toddlers, followed by infants (χ²=379.57, P<0.001). The positive rate peaked in 2021 and reached its lowest point in 2023 (χ²=45.49, P<0.001), with epidemics mainly prevalent in summer and autumn. The main clinical symptoms were cough (90.06%, 453/503), fever (75.94%, 382/503), and wheezing (39.96%, 201/503). Children with severe pneumonia showed a higher incidence of wheezing compared with the non-severe group (P<0.001), while underlying diseases and co-infections had no significant association with disease severity (P>0.05). ConclusionHBoV was an important pathogen of ALRTI in children, predominantly affecting infants and toddlers, with higher susceptibility in boys and seasonal peaks in autumn and summer. The main clinical manifestations included cough, fever, and wheezing, with wheezing being more prevalent in children with severe pneumonia.
8.Primary intestinal lymphangiectasia in a 5-month-old boy
Youran LI ; Ting ZHANG ; Ruixue WANG
Clinical Endoscopy 2026;59(1):147-148
9.Zuoguiwan Mitigates Oxidative Stress in Rat Model of Hyperthyroidism Due to Kidney-Yin Deficiency via DRD4/NOX4 Pathway
Ling LIN ; Qianming LIANG ; Changsheng DENG ; Li RU ; Zhiyong XU ; Chao LI ; Mingshun SHEN ; Yueming YUAN ; Muzi LI ; Lei YANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(2):43-51
ObjectiveTo decipher the mechanism by which Zuoguiwan (ZGW) treat hyperthyroidism in rats with kidney-Yin deficiency based on the dopamine receptor D4 (DRD4)/nicotinamide adenine dinucleotide phosphate (NADPH) oxidase 4 (NOX4) signaling pathway. MethodsThe rat model of kidney-Yin deficiency was induced by unilateral intramuscular injection of dexamethasone (0.35 mg·kg-1). After successful modeling, the rats were randomized into model, methimazole (positive control, 5 mg·kg-1), low-, medium-, and high-dose (1.85, 3.70, 7.40 g·kg-1, respectively) ZGW, and normal control groups. After 21 days of continuous gavage, the behavioral indexes and body weight changes of rats were evaluated. The pathological changes of the renal tissue were observed by hematoxylin-eosin staining. The serum levels of thyroid hormones [triiodothyronine (T3), thyroxine (T4), thyroid-stimulating hormone (TSH)], renal function indexes [serum creatine (Scr) and blood urea nitrogen (BUN)], energy metabolism markers [cyclic adenosine monophosphate (cAMP) and cyclic guanosine monophosphate (cGMP)], and oxidative stress-related factors [superoxide dismutase (SOD), malondialdehyde (MDA), and NADPH)] were measured by enzyme-linked immunosorbent assay (ELISA). Western blot was employed to analyze the expression of DRD4, NOX4, mitochondrial respiratory chain complex proteins [NADH:ubiquinone oxidoreductase subunit S4 (NDUFS4) and cytochrome C oxidase subunit 4 (COX4)], and inflammation-related protein [tumor necrosis factor-alpha (TNF-α), interleukin-6 (IL-6), p38 mitogen-activated protein kinase (MAPK)] pathway in the renal tissue. ResultsCompared with the normal group, the model group showed mental malaise, body weight decreases (P<0.01), inflammatory cell infiltration in the renal tissue, a few residual parotid glands in the thyroid, elevations in serum levels of T3, T4, Scr, BUN, cAMP, cAMP/cGMP, MDA, and NADPH (P<0.01), down-regulation in protein levels of TSH, SOD, and DRD4 (P<0.05, P<0.01), and up-regulation in expression of NOX4, p-p38 MAPK/p38 MAPK, and inflammatory factors (P<0.01). Compared with the model group, ZGW increased the body weight (P<0.05, P<0.01), reduced the infiltration of renal interstitial inflammatory cells, restored the thyroid structure and follicle size, lowered the serum levels of T3, T4, Scr, BUN, cAMP, cAMP/cGMP, MDA and NADPH (P<0.05, P<0.01), up-regulated the expression of TSH, SOD and DRD4 (P<0.05, P<0.01), and down-regulated the expression of NOX4, p-p38 MAPK/p38 MAPK, and inflammatory factors (P<0.05, P<0.01). Moreover, high-dose ZGW outperformed methimazole (P<0.05). ConclusionBy activating DRD4, ZGW can inhibit the expression of NOX4 mediated by the p38 MAPK pathway, reduce oxidative stress and inflammatory response, thereby ameliorating the pathological state of hyperthyroidism due to kidney-Yin deficiency. This study provides new molecular mechanism support for the clinical application of ZGW.
10.Mechanisms of Shenqi Wenfei Prescription in Intervening in Chronic Obstructive Pulmonary Disease in Rats Based on ROS/TXNIP/NLRP3 Signaling Pathway
Di WU ; Mengyao SHI ; Lu ZHANG ; Tong LIU ; Jiabing TONG ; Cheng YANG ; Zegeng LI
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(3):78-87
ObjectiveTo investigate the effects and underlying mechanisms of Shenqi Wenfei prescription (SQWF) on chronic obstructive pulmonary disease (COPD). MethodsA rat model of COPD with lung Qi deficiency was established using lipopolysaccharide (LPS) combined with cigarette smoke. Forty-eight SD rats were randomly divided into a blank group, a model group, low-, medium-, and high-dose SQWF groups (2.835, 5.67, 11.34 g·kg-1), and a Yupingfeng group (1.35 g·kg-1). Drug administration began on day 29 after modeling and continued for 2 weeks. The general condition of the rats was observed, and the lung function in each group was assessed. Hematoxylin-eosin (HE) staining was used to observe pathological changes in lung tissue. The proportion of inflammatory cells in bronchoalveolar lavage fluid (BALF) was measured. Apoptosis in lung tissue was examined by terminal deoxynucleotidyl transferase-mediated dUTP nick end-labeling (TUNEL) staining. The release level of lactate dehydrogenase (LDH) in BALF was detected by a microplate assay. Reactive oxygen species (ROS) levels in lung tissue were detected using fluorescent probes. The levels of malondialdehyde (MDA), total superoxide dismutase (SOD), and reduced glutathione (GSH) in BALF were measured by biochemical methods. Ultrastructural changes in lung cells were observed via transmission electron microscopy. Double immunofluorescence staining was performed to detect the expression of thioredoxin-interacting protein (TXNIP) and nucleotide-binding oligomerization domain-like receptor protein 3 (NLRP3) in lung tissue. Western blot analysis was used to detect the protein expression of TXNIP, NLRP3, apoptosis-associated speck-like protein containing a CARD (ASC), cysteinyl aspartate-specific protease-1 (Caspase-1), Caspase-1 p20, gasdermin D (GSDMD), GSDMD N-terminal active fragment (GSDMD-N), interleukin-1β (IL-1β), and IL-18 in lung tissue. Serum IL-1β and IL-18 levels were measured by ELISA. ResultsCompared with the blank group, the model group showed lassitude, fatigue, tachypnea, and audible phlegm sounds, and lung function significantly declined (P0.01). Pulmonary emphysema and inflammatory cell infiltration were obvious. The level of inflammatory cells in BALF increased significantly (P0.05). The number of TUNEL-positive cells increased (P0.01). Levels of LDH, ROS, and MDA in BALF increased significantly (P0.01), while GSH and SOD activities decreased significantly (P0.01). Lung tissue cells showed irregular morphology, swollen mitochondria, disrupted cell membranes, and abundant vesicles, i.e., pyroptotic bodies. Protein levels of TXNIP, NLRP3, ASC, Caspase-1, Caspase-1 p20, GSDMD, GSDMD-N, IL-1β, and IL-18 in lung tissue were significantly elevated (P0.01), and serum IL-1β and IL-18 levels also increased significantly (P0.01). Compared with the model group, each medication group showed alleviation of qi deficiency symptoms and improved lung function (P0.01). Pulmonary emphysema and inflammatory cell infiltration were reduced. Inflammatory cell levels decreased (P0.05). The number of TUNEL-positive cells decreased significantly (P0.01). Levels of LDH, ROS, and MDA decreased significantly (P0.05), while GSH and SOD activities significantly increased (P0.01). Morphological and structural damage in lung tissue was improved to varying degrees. Protein levels of TXNIP, NLRP3, ASC, Caspase-1, Caspase-1 p20, GSDMD, GSDMD-N, IL-1β, and IL-18 in lung tissue significantly decreased (P0.01), and serum IL-1β and IL-18 levels also decreased significantly (P0.05). ConclusionSQWF can improve lung function and alleviate inflammatory responses in COPD rats. Its mechanism may be related to regulating the ROS/TXNIP/NLRP3 pathway and inhibiting pyroptosis.


Result Analysis
Print
Save
E-mail